Honeywell MS9535-5 Configuration Guide

Honeywell MS9535-5 Manual

Honeywell MS9535-5 manual content summary:

  • Honeywell MS9535-5 | Configuration Guide - Page 1
    MetroSelect® Single-Line Scanner Configuration Guide
  • Honeywell MS9535-5 | Configuration Guide - Page 2
    manual. VoyagerBT and Focus are trademarks or registered trademarks of Metrologic Instruments, Inc. or Honeywell International Inc. Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation. IBM is a trademark of International Business Machines Corporation. The Bluetooth
  • Honeywell MS9535-5 | Configuration Guide - Page 3
    1-1 Single-Code Method 1-1 Multi-Code Method 1-1 Need to Start Over 1-2 Code Types and Decode Rules UPC/EAN 2-1 Code 128 2-2 Code 39 ...2-2 2 of 5 Codes 2-4 Codabar ...2-6 Code 93 ...2-6 Code 11 ...2-6 Telepen...2-7 Plessey Codes 2-7 Additional Decode Features 2-8 Configurable Code Lengths
  • Honeywell MS9535-5 | Configuration Guide - Page 4
    Scanner Commands 7-8 Test Modes 7-10 Prefixes/Suffixes User Configurable Prefixes, All Data 8-1 User Configurable ID Characters, Code Specific 8-2 Standard Prefix Characters 8-4 Standard Suffix Characters 8-6 Longitudinal Redundancy Check 8-7 Block Check Character 8-7 Character Replacements
  • Honeywell MS9535-5 | Configuration Guide - Page 5
    Enable Keyboard Emulation 11-1 Country/Scan Code Table Selects 11-1 Keyboard/System Type 11-2 'Dumb' Terminal Selections 11-3 Special Keyboard Features 11-4 InterScan Code Delays 11-6 Control Sets 11-7 OCIA 12-1 Light Pen Parameters 13-1 Set Narrow Element Width 13-2 RS485 Configuration
  • Honeywell MS9535-5 | Configuration Guide - Page 6
    -1 MS9535-5M VoyagerBT 20-1 Inventory Quantity Bar Codes 20-3 IS4125 and IS4225 Scan Engines 21-1 IS4823 and IS4825 Scan Engines 22-1 Operating Modes 22-1 Miscellaneous Features Custom Defaults 23-1 Serial Program Mode 23-2 Customer Support 24-1 Technical Assistance 24-1 Product Service and
  • Honeywell MS9535-5 | Configuration Guide - Page 7
    The scanner will emit a multi-toned beep to indicate the configuration has been saved to NOVRAM. Multi-Code Method All features can be enabled or disabled using the Multi-Code Method. A feature marked with a tilde ( ~ ) requires the Multi-Code Method. 1. Power-up the scanner. 2. Scan the enter/exit
  • Honeywell MS9535-5 | Configuration Guide - Page 8
    Need To Start Over? Scan the Recall Defaults bar code to erase all previous settings and return the scanner to its factory default communication protocol. Keyboard Wedge interface scanners will load keyboard wedge defaults. All other scanners load RS232 defaults. Note: Honeywell manufactures several
  • Honeywell MS9535-5 | Configuration Guide - Page 9
    ( ~ ) require the Multi-Code configuration method. UPC/EAN ³ 100116 ³ 100106 ³ 100216 ³ 100206 ³ 100210 ³ 100200 ³ 100211 ³ 100201 ³ 100214 ³ 100204 * Enable UPC/EAN Disable UPC/EAN * Enable UPC-A Disable UPC-A * Enable UPC-E Disable UPC-E * Enable EAN-13 Disable EAN-13 * Enable EAN-8 Disable EAN
  • Honeywell MS9535-5 | Configuration Guide - Page 10
    ³ 100101 ³ 100213 ³ 100203 ³ 100217 ³ 100207 * Enable Code 39 Disable Code 39 Enable MOD 43 Check Digit on Code 39 - The scanner only scans Code 39 bar codes that have a valid Modulo 43 check digit. * Disable MOD 43 Check Digit on Code 39 Enable Full ASCII Code 39 * Disable Full ASCII Code 39 2-2
  • Honeywell MS9535-5 | Configuration Guide - Page 11
    . * Disable PARAF Support * Allow PARAF Codes Only Allow Non-PARAF Codes Enable TRI-OPTIC Code * Disable TRI-OPTIC Code * Use Standard Code 39 Framing Try Code 39 Codes Without 5 Bar Multiples Enable ITF/Code 39 Filters * Disable ITF/Code 39 Filters Enable Self-Service Library Code 39 * Disable Self
  • Honeywell MS9535-5 | Configuration Guide - Page 12
    Interleaved 2 of 5 (ITF) ³ 100105 Disable Interleaved 2 of 5 (ITF) ³ 100310 ³ 100300 Enable MOD 10 Check on ITF - The scanner will only scan Interleaved 2 of 5 (ITF) bar codes that have a Modulo 10 check digit. * Disable MOD 10 Check on ITF ³ 107817 Allow ITF Null Characters ³ 107807 ³ 901600
  • Honeywell MS9535-5 | Configuration Guide - Page 13
    Standard 2 of 5 Symbol Length - To specify the number of characters to be decoded, scan this bar code and the appropriate code byte sequence located on page 16-1. Enable Matrix 2 of 5 * Disable Matrix 2 of 5 * Enable Matrix 2 of 5 Check Digit Requirement Disable Matrix 2 of 5 Check Digit Requirement
  • Honeywell MS9535-5 | Configuration Guide - Page 14
    Disable Hong Kong 2 of 5 Enable Follett ITF * Disable Follett ITF Codabar ³ 100114 ³ 100104 ³ 100012 ³ 100002 * Enable Codabar Disable Codabar Enable Dual Field Codabar * Disable Dual Field Codabar Code 93 ³ 100112 ³ 100102 * Enable Code 93 Disable Code 93 Code 11 ³ 100013 Enable Code 11 2-6
  • Honeywell MS9535-5 | Configuration Guide - Page 15
    108004 ³ 108014 * Disable Code 11 * Check for 1 Code 11 Check Digit Check for 2 Code 11 Check Digits * Do Not Check for 2 Code 11 Check Digits Check for 2 Code 11 Check Digits if Code Length is Greater Than 10 Characters Telepen ³ 100017 ³ 100007 ³ 100016 ³ 100006 Enable Telepen * Disable Telepen
  • Honeywell MS9535-5 | Configuration Guide - Page 16
    MOD 10/10 Check Digit - Test MSI Plessey bar codes for a 2 digit Modulo 10 check digit. * Enable MSI Plessey MOD 10 Check Digit - Test MSI Plessey bar codes for a 1 digit Modulo 10 check digit. Enable UK Plessey * Disable UK Plessey Enabled UK Plessey A to X Conversion * Disabled UK Plessey A to
  • Honeywell MS9535-5 | Configuration Guide - Page 17
    to a lock length. While in configuration mode: 1. Scan the code length lock #1 bar code (below). 2. Scan the three code bytes that represent the code length (on page 16-1). 3. Scan the matching code type lock #1 bar code (below). 4. Scan the three code bytes that represent the code type (on page 16
  • Honeywell MS9535-5 | Configuration Guide - Page 18
    ~ Code Length Lock #2 ~ Code Type Lock #2 ~ Code Length Lock #3 ~ Code Type Lock #3 ~ Code Length Lock #4 ~ Code Type Lock #4 ~ Code Length Lock #5 ~ Code Type Lock #5 ~ Code Length Lock #6 ~ Code Type Lock #6 ~ Code Length Lock #7. ~ Code Type Lock #7. ³ 124713 ³ 124703 2-10 Enable Japanese
  • Honeywell MS9535-5 | Configuration Guide - Page 19
    Two Digit Redundancies - The scanner will scan the bar code plus the 2 digit add on twice before accepting data. Disable Two Digit Redundancies Enable Five Digit Supplements * Disable Five Digit Supplements Enable Five Digit Redundancies - The scanner will scan the bar code plus the 5 digit add
  • Honeywell MS9535-5 | Configuration Guide - Page 20
    Required * Disable Bookland (978) Supplement Required Enable 977 (2 Digit) Supplement Required - The scanner will require a 2 digit supplement to be scanned when an EAN-13 code begins with 977. * Disable 977 (2 Digit) Supplement Required Enable 378/379 French Supplement Required * Disable 378
  • Honeywell MS9535-5 | Configuration Guide - Page 21
    Extended Code Format. * Enable Code 128 Group Separators - A "GS" (1DH) character will be transmitted with coupon Code 128 codes. Disable Code 128 Group Separators 400 msec to Find Supplemental - The scanner will allot 400 milliseconds to find an add on after a main UPC/EAN bar code has been scanned
  • Honeywell MS9535-5 | Configuration Guide - Page 22
    ³ 101315 ³ 101305 ³ 101317 ³ 101307 ³ 101316 ³ 101306 ³ 125115 ³ 125105 ³ 125106 ³ 125116 Enable Code ID's with Supplements * Disable Code ID's with Supplements * Beep Once on Supplements Beep Twice on Supplements Enable ISBN Check Digit Transmission - Not available with all models. Disable ISBN
  • Honeywell MS9535-5 | Configuration Guide - Page 23
    CodeGate Button is Pressed - Available for MS9540 scanners only. Requires standard Code Gate be inactive in and out of stand. * CodeGate Does Not Affect Supplemental Scanning - Available for MS9540 scanners only. No Supplement Checking if EAN-13 Code is just scanned * Normal Supplement Checking 3-5
  • Honeywell MS9535-5 | Configuration Guide - Page 24
    3-6
  • Honeywell MS9535-5 | Configuration Guide - Page 25
    MS9520 Voyager® and MS9540 VoyagerCG® scanners with software #14810 and higher can be configured to scan GS1 DataBar type bar codes. ³ 100011 Double Border Required - Due to the large spaces commonly found in GS1 DataBar symbologies, Honeywell recommends double border requirements be enabled when
  • Honeywell MS9535-5 | Configuration Guide - Page 26
    GS1 DataBar Limited ³ 100414 Enable GS1 DataBar Limited * Disable GS1 DataBar Limited ³ 100404 * Transmit 114915 Do Not Transmit GS1 DataBar Limited Symbology ID GS1 DataBar Expanded ³ 100415 Enable GS1 DataBar Expanded * Disable GS1 DataBar Expanded ³ 100405 * Transmit GS1 DataBar
  • Honeywell MS9535-5 | Configuration Guide - Page 27
    Code 128 Implementation Configuration Mode ³ 138417 Enable ISBT Code 128 ³ 138407 Disable ISBT Code 128 The bar codes below enable or disable a special transmit mode as outlined in section 3.5.2 of the ISBT-128 Specification. This output method allows the user Identification number will be the
  • Honeywell MS9535-5 | Configuration Guide - Page 28
    Sequence ³ 301370 700 msec to Find Concatenation Sequence Pre-Defined Concatenation Configuration Mode† The first two bar codes below enable or disable pre-defined concatenation sequences. The remaining bar codes enable the specific pre-defined concatenation sequence shown, but are not needed to
  • Honeywell MS9535-5 | Configuration Guide - Page 29
    . The remaining bar codes are used to enter the user-defined identifiers used in the concatenation sequence. First enter configuration mode then scan the one of the identifier codes, followed by the code byte sequence or the desired identifiers. ³ 138414 Enable User-Defined Sequences ³ 138404
  • Honeywell MS9535-5 | Configuration Guide - Page 30
    bar Code. 11. Scan the Enable ISBT bar code. 12. Scan the ENTER/EXIT configuration mode bar code. The scanner is now configured with the appropriate identifiers. Since both ISBT and User-defined Concatenation are enabled, ISBT 128 bar codes scanned successively that contain these identifiers will be
  • Honeywell MS9535-5 | Configuration Guide - Page 31
    Pen/Wand Communication - Use this option if scanner should be used in place of a light pen. * Enable RS232 - The scanner will work with RS232 +/- 12V serial output. ³ 999994 ³ 5155153 ³ 5155143 ³ 999993 Load Keyboard Wedge Defaults - Scan this code before selecting Normal or Stand Alone Wedge Mode
  • Honeywell MS9535-5 | Configuration Guide - Page 32
    6-2
  • Honeywell MS9535-5 | Configuration Guide - Page 33
    Up - The scanner can only enter MetroSet mode before any bar codes are scanned. ³ 118107 * Allow Configuration Mode Anytime - Allow MetroSet configuration at any time. ³ 118116 ³ 118106 Allow configuration Codes on Power Up - Once a product bar code is scanned after powerup, the scanner will not
  • Honeywell MS9535-5 | Configuration Guide - Page 34
    decodes of the same bar code data for a good scan. 2 Redundant Scans - Requires 3 consecutive decodes of the same bar code data for a good scan. 3 Redundant Scans - Requires 4 consecutive decodes of the same bar code data for a good scan. 4 Redundant Scans - Requires 5 consecutive decodes of the
  • Honeywell MS9535-5 | Configuration Guide - Page 35
    ³ 818900 ³ 118917 Infinite Same Symbol Time Out - The scanner will not repetitively scan the same bar code. This option overrides the symbol rescan time-outs. ³ 119414 ³ 119404 Enable 2 Second Time Out - after 2 seconds of inactivity the laser will turn off and stay off until the CodeGate button
  • Honeywell MS9535-5 | Configuration Guide - Page 36
    Tone 6 ³ 318505 No Beep ³ 118406 * Beep Once on Supplements ³ 118416 Beep Twice on Supplements ³ 118414 Enable Fast Beep ³ 118404 * Disable Fast Beep ³ 118512 ³ 118502 Enable Fun Tones - scan this bar code then scan one of the Optional Tone bar codes above. * Disable Fun Tones 7-4
  • Honeywell MS9535-5 | Configuration Guide - Page 37
    from the host. If a number is sent within 200 msecs before the BEL character, the scanner will beep that number of times. * Ignore BEL Command Enable Light Pen Toggle During Beep - The scanner beeps and toggles the light pen data line on a successful decode. This drives a good read indicator
  • Honeywell MS9535-5 | Configuration Guide - Page 38
    This helps prevent the scanner from overflowing host-input buffers. ³ 818810 * 1 msec Intercharacter Delay ³ 8188100 10 msec Intercharacter Delay ³ 8188250 25 msec Intercharacter Delay ³ 918800 ~ Variable msec Intercharacter Delay - Scan this bar code and a sequence of code bytes on page 16
  • Honeywell MS9535-5 | Configuration Guide - Page 39
    Communication Time Out Options ³ 118412 Enable Communications Time Out ³ 118402 * Disable Communications Time Out ³ 118413 * Beep Before Transmit ³ 118403 Beep After Transmit ³ 919100 ~ Variable Communications Time Out * Default Communications Time Out (2
  • Honeywell MS9535-5 | Configuration Guide - Page 40
    ASCII "D" from the host device. It will enable scanning when it receives an ASCII "E". * Disable D/E Disable. ³ 118211 ³ 118201 Enable Z/R Type D/E Simulation - The scanner will disable scanning after it receives an ASCII "Z" from the host device. It will enable scanning when it receives an ASCII
  • Honeywell MS9535-5 | Configuration Guide - Page 41
    - The ID byte is transmitted as 3 bytes (i.e. 0, 0, 1). * Don't Transmit Scanner ID byte with receipt of an "i" (69H) via RS232 Transmit NO READ if DC2 Activated READ Transmit Transmit Serial Number Enable Motor On/Off Commands * Disable Motor On/Off Commands Disable RS232 Receive Normal RS232
  • Honeywell MS9535-5 | Configuration Guide - Page 42
    ON - The scanner will enter scan count test mode and the scanner's firmware number will transmit to the host. Do not enable unless instructed by a Honeywell representative. * Scan Count Mode OFF Power-Up with Saved Interface - Do not enable unless instructed by a Honeywell representative. * Power-Up
  • Honeywell MS9535-5 | Configuration Guide - Page 43
    8 Prefixes/Suffixes Scan the Enter Configuration Mode bar code before trying to set these features (see the Multi-Code Method on page 1-1). User Configurable Prefixes, All Data ³ 903500 ³ 903600 ³ 903700 ³ 903800 ³ 903900 ³ 904000 ³ 904100 ³ 904200 ~ Configurable Prefix Character #1 - A prefix
  • Honeywell MS9535-5 | Configuration Guide - Page 44
    used. ³ 105517 Use Configurable Code ID Bytes as Suffixes - User configured, code specific ID bytes are transmitted after the data. If using suffixes, user configured prefixes cannot be used. ‡ Enter configuration mode then scan this bar code followed by the three code byte bar codes (on page 16
  • Honeywell MS9535-5 | Configuration Guide - Page 45
    ‡ Enter configuration mode then scan this bar code followed by the three code byte bar codes (on page 16-1) that represent a unique ID character to be associated with this bar code type. ³ 907200 ~ Configurable TRI-OPTIC ID ‡ ³ 907100 ~ Configurable Standard 2 of 5 ID ‡ ³ 906700 ~ Configurable
  • Honeywell MS9535-5 | Configuration Guide - Page 46
    Standard Prefix Characters ³ 116615 Enable STX Prefix - The scanner will transmit a Start of TeXt (ASCII 02H) before each bar code. ³ 116605 * Disable STX Prefix ³ 105513 Enable Rochford-Thomson Mode ³ 105503 * Disable Rochford-Thomson Mode ³ 107915 Enable AIM ID Characters ³ 107905 *
  • Honeywell MS9535-5 | Configuration Guide - Page 47
    ID Prefix * Disable Manufacturer ID Prefix Enable "C" Prefix * Disable "C" Prefix Enable "$" Prefix ID for UPC/EAN * Disable "$" Prefix ID for UPC/EAN Enable Tab Prefix - The scanner will transmit a TAB (ASCII 09H) before each bar code. * Disable Tab Prefix Enable SNI Beetle Mode * Disable SNI
  • Honeywell MS9535-5 | Configuration Guide - Page 48
    scanner transmits a carriage return after each bar code. ³ 116603 Disable CR Suffix. ³ 116612 ³ 116602 * Enable LF Suffix - The scanner transmits a line feed after each bar code. Disabled when keyboard wedge defaults are loaded. Disable LF Suffix. ³ 116610 Enable Tab Suffix - The scanner will
  • Honeywell MS9535-5 | Configuration Guide - Page 49
    on the first byte transmitted. ³ 107811 ³ 107801 ³ 107800 ³ 107810 Enable Transmit of LRC Calculation - The scanner outputs on LRC check character after the bar code. * Disable Transmit of LRC Calculation. * Start LRC on First Byte - The scanner will calculate the LRC check digit starting with the
  • Honeywell MS9535-5 | Configuration Guide - Page 50
    you wish to replace. Refer to the ASCII Reference Table in the Code Byte Usage section of this manual. 4. Scan the replacement character bar code (shown below). 5. Scan the ASCII code byte value of the replacement character. 6. Scan the enter/exit configuration mode bar code (on page 1-1). ³ 938600
  • Honeywell MS9535-5 | Configuration Guide - Page 51
    User Configurable Suffixes, All Data Note: Scan the Enter/Exit Configuration mode code before trying to set this feature. Refer to Multi-Code Method on page 1-1. ³ 904500 ³ 904600 ~ Configurable Suffix Character #1 - A suffix ID can be added and assigned for data transmission. Use this code with
  • Honeywell MS9535-5 | Configuration Guide - Page 52
    SINEKO Mode ³ 107904 * Disable SINEKO Mode ³ 116711 Enable Newcode Formatting Mode A ³ 116701 * Disable Newcode Formatting Mode A ³ 116710 Enable Newcode Formatting Mode B ³ 116700 * Disable Newcode Formatting Mode B ³ 108017 Remove All Leading Zero's ³ 108007 * Do Not Remove Leading
  • Honeywell MS9535-5 | Configuration Guide - Page 53
    E ³ 107612 Do Not Send Number System on Expanded UPC E ³ 107510 Enable GTIN Formatting ³ 107500 * Disable GTIN Formatting ³ 107514 ³ 107504 Convert UPC-A to EAN-13 - The scanner converts UPC-A to EAN-13 by transmitting a leading zero before the bar code. * Do Not Convert UPC-A to EAN-13 9-1
  • Honeywell MS9535-5 | Configuration Guide - Page 54
    ³ 107910 ³ 107900 ³ 107912 ³ 107902 Transmit Lead Zero on UPC-E - This option will transmit a zero before each UPC-E bar code. Do Not Transmit Lead Zero on UPC-E Convert EAN-8 to EAN-13 - The scanner will transmit five zeros before the bar code to convert EAN-8 to EAN-13. * Do Not Convert EAN-8 to
  • Honeywell MS9535-5 | Configuration Guide - Page 55
    code. ³ 107707 * Do Not Transmit Codabar Start/Stop ³ 115100 * Normal Codabar Start/Stop Characters ³ 115110 Enable Transmit Codabar Start/Stop Characters as Lower Case Characters ³ 107716 ³ 107706 Enable CLSI Editing - Works only with 14 digit Codabar type lengths. This option will
  • Honeywell MS9535-5 | Configuration Guide - Page 56
    ) Prefix if Italian Pharmaceutical Code 11 Formatting ³ 107713 Transmit Code 11 Check Digit - This bar code will transmit Code 11 check characters when used with Enabled Code 11 on page 2-6. ³ 107703 * Do Not Transmit Code 11 Check Digit Telepen ³ 107814 ³ 107804 Enable Convert Telepen ^L to
  • Honeywell MS9535-5 | Configuration Guide - Page 57
    option works in conjunction with one or both of the Enabled MSI Plessey Mod options on page 2-7. * Do Not Transmit MSI Plessey Check Digit 2 of 5 Code Formatting ³ 107714 Transmit Mod 10 Check Digit on ITF - The scanner transmits interleaved 2 of 5 (ITF) Mod 10 check character. ³ 107704 * Do
  • Honeywell MS9535-5 | Configuration Guide - Page 58
    9-6
  • Honeywell MS9535-5 | Configuration Guide - Page 59
    Enable RS232 Mode - The scanner will work with RS232 +/-12V serial output. Parity Features A parity bit is an extra data bit used to help catch data transmission errors. The scanner Not available with Voyager) 57600 BAUD Rate (Not available with Voyager) 38400 BAUD Rate 19200 BAUD Rate 14400 BAUD Rate
  • Honeywell MS9535-5 | Configuration Guide - Page 60
    - The number of data bits transmitted for each character. ³ 116003 * 7 Data Bits ³ 116014 1 Stop Bit ³ 116004 * 2 Stop Bits Hardware Handshaking ³ 115816 Enable RTS/CTS Handshaking - Output a Request to Send (RTS) signal and wait for a Clear to Send (CTS) signal before transmitting data
  • Honeywell MS9535-5 | Configuration Guide - Page 61
    Not Present Before RTS (RSV4) - Do not activate RTS if CTS is already present. ³ 124503 * Do Not Test for CTS Present Before RTS ³ 115817 ³ 115807 Enable DTR Support - The scanner will stop scanning when the Data Terminal Ready (DTR) signal goes inactive. * Disable DTR
  • Honeywell MS9535-5 | Configuration Guide - Page 62
    Toggle ³ 115914 ³ 115904 Enable XON/XOFF Handshaking - The scanner will stop transmission whenever on XOFF (ASCII 13H) is received. Transmission will resume after an XON (ASCII 11H) is received. * Disable XON/XOFF Handshaking. Software Handshaking ³ 115913 Enable ACK/NAK - After transmitting
  • Honeywell MS9535-5 | Configuration Guide - Page 63
    . ACK will no longer be accepted but NAK and any additional ACK/NAK protocol characters enabled are still accepted. * Disable GLS Handshaking Miscellaneous ³ 116110 Enable French PC Term - The scanner transmits PC type make/break scan codes instead of ASCII data characters. The scan codes match
  • Honeywell MS9535-5 | Configuration Guide - Page 64
    10-6
  • Honeywell MS9535-5 | Configuration Guide - Page 65
    that are not cabled for an external keyboard. Scan this bar code to enable the Stand-Alone Mode. The scanner will send keyboard "power on" information and configure hardware to simulate a constant keyboard connection. * Enable Keyboard Wedge Emulation - Use this ³ 5 1 5 5 1 4 3 with an external
  • Honeywell MS9535-5 | Configuration Guide - Page 66
    Special firmware in Voyager. ³ 216225 PS/2 Keyboard - Includes IBM PC and compatible models 30, 70, 8556. ³ 216235 ³ 116307 ³ 116317 Enable Terminal Keyboard Emulation. Enable XT Keyboard for Mode 1 - Special firmware in Voyager. Enable XT Keyboard for Mode 2 - Special firmware in Voyager. 11-2
  • Honeywell MS9535-5 | Configuration Guide - Page 67
    #8 ³ 116714 ³ 116704 Lower Case Lock On - transmit all data as lower case. * Lower Case Lock Off ³ 116715 ³ 116705 Spanish Keyboard Ñ Substitution - the following two characters will translate as follows: # to Ñ and ^ to ñ. * No Spanish Keyboard Ñ Substitution
  • Honeywell MS9535-5 | Configuration Guide - Page 68
    * Transmit FOH Break Code - The scanner will transmit the FOH in the break-code sequence. ³ 116300 ³ 116315 Do Not Transmit FOH Break Code Transmit Cleanup Bit - Use for certain NEC computers. ³ 116305 * Do Not Transmit Cleanup Bit ³ 116217 Enable Alt-Mode - See Enable ALT-Mode (Normal) for
  • Honeywell MS9535-5 | Configuration Guide - Page 69
    data is sent as if it has been entered on a keypad. ³ 116306 * Send Numbers as Normal Data ³ 116410 Enable Reserved Feature ³ 116400 * Disable Reserved Feature ³ 116303 ³ 116313 ³ 116304 * Use Extended ASCII To Send Extended Key Codes - Use extended ASCII characters to send PC keyboard keys
  • Honeywell MS9535-5 | Configuration Guide - Page 70
    116413 Enable LaCaixa Special Keyboard Prefix & Suffix Scan Codes ³ 116403 * Disable LaCaixa Special Keyboard Prefix & Suffix Scan Codes InterScan Code Delays ³ 816580 * InterScan Code Delay 800 msec - The time specified represents the amount of time between individual 11-bit scan codes. This
  • Honeywell MS9535-5 | Configuration Guide - Page 71
    'bar coding' the extended keys is to substitute the extended key codes when a specific ASCII control character is found in the bar code stream. The Control Sets are specific translations of the ASCII (HEX) set. Control Set #1 ³ 416484 Enable Control Set #1 ³ 416404 * Disable Control Set #1 11-7
  • Honeywell MS9535-5 | Configuration Guide - Page 72
    10H 11H 12H 13H 14H 15H 16H 17H 18H 19H 1AH 1BH 1CH 1DH 1EH 1FH 11-8 ASCII Control Null SOH STX ETX EOT ENQ ACK BEL BS TAB LF VT FF CR System Request  (Right Arrow)  (Left Arrow) Tab Caps Lock Shift Tab Left Alt Enter Left Control Up Arrow F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Home Esc Page Up Page
  • Honeywell MS9535-5 | Configuration Guide - Page 73
    The host clocks this serial interface. Load OCIA Defaults ³ 217706 Enable DTS/Siemens ³ 217716 * Enable DTS/Nixdorf ³ 217736 Enable NCR-S ³ 217726 Enable NCR-F ³ 117705 * Transmit character count with non-UPC codes while transmitting in OCIA NCR-S mode ³ 117715 Do not Transmit character
  • Honeywell MS9535-5 | Configuration Guide - Page 74
    12-2
  • Honeywell MS9535-5 | Configuration Guide - Page 75
    415524 ³ 116917 Enable Light Pen Mode - Select this option if the scanner will be used in place of a light pen. It provides light pen emulation of each bar code scanned. * Bars High ³ 116907 Spaces High ³ 116916 Transmit as Code 39 - All bar codes will be decoded then transmitted as Code 39 bar
  • Honeywell MS9535-5 | Configuration Guide - Page 76
    60 µs Narrow Element Width ³ 8168160 100 µs Narrow Element Width ³ 8168820 500 µs Narrow Element Width ³ 916800 ~ Variable Narrow Element Width - Sets the minimum x-dimension in 6 µs increments. Scan this code followed by a 3-digit code byte sequence (on page 16-1). 13-2
  • Honeywell MS9535-5 | Configuration Guide - Page 77
    14 IBM® 46xx Configuration IBM Port ³ 415504 Enable RS485 Communication - For RS485 communications. Not all scanners support this interface. CTS select of RS485 vs RS232 Enable RS485 transmit when CTS = -12 Volt & RS232 transmit when CTS = +12 Volt IBM Reserved Codes IBM Reserved #1 ³ 317200 ³
  • Honeywell MS9535-5 | Configuration Guide - Page 78
    14-2
  • Honeywell MS9535-5 | Configuration Guide - Page 79
    - Full Speed USB Only ³ 3164010 IBM OEM Scanner 4A00h Flat-Bed - Full Speed USB Only ³ 316400 * Enable USB Keyboard Emulation Mode Note: USB Keyboard Emulation Mode is a factory default. If the Recall Defaults bar code is scanned while reconfiguring the scanner, the scanner configuration will
  • Honeywell MS9535-5 | Configuration Guide - Page 80
    Supported in Honeywell MS9500, MS5100 and IS4125 laser-class products. Note: This configuration code is not supported for Focus/Imager class products (see note above). Enable Bar Code ID Disable Bar Code ID Enable USB Reserve Code #1 Disable USB Reserve Code #1 Enable USB Reserve Code #2 Disable USB
  • Honeywell MS9535-5 | Configuration Guide - Page 81
    the features requiring code bytes for configuration. The Enter/Exit Configuration Mode bar code must be scanned before starting the configuration cycle. User configurable prefix/suffix characters can then be saved by scanning the 3 digit decimal equivalent of the ASCII character into the appropriate
  • Honeywell MS9535-5 | Configuration Guide - Page 82
    ³ 8 Code Byte 8 ³ 9 Code Byte 9 Reserved Codes ³ 999988 ~ Enable Reserved Code - Contact Honeywell for information about this feature. ³ 999987 ~ Disable Reserved Code Code Type Table Code Byte 004 002 003 005 080 081 082 083 084 091 092 093 094 095 096 099 098 097 Code Types UPC-A UPC-E
  • Honeywell MS9535-5 | Configuration Guide - Page 83
    ASCII Reference Table HEX Value 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C Decimal Value/ Code Byte Value 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014
  • Honeywell MS9535-5 | Configuration Guide - Page 84
    26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 16-4 Decimal Value/ Code Byte Value 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051
  • Honeywell MS9535-5 | Configuration Guide - Page 85
    43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 Decimal Value/ Code Byte Value 060 061 062 063 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082
  • Honeywell MS9535-5 | Configuration Guide - Page 86
    62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 Decimal Value/ Code Byte Value 090 091 092 093 094 095 096 097 098 099 100 101 102 103 104 105 106 107 108 109 110 111 112
  • Honeywell MS9535-5 | Configuration Guide - Page 87
    Control Keyboard Eqv vertical slash alt mode (alt mode) delete, rubout Extended Key Code Reference Table Key At Scan PS2 Scan Code Code Insert Delete Home End Page Up Page Down Right Alt Right Ctrl Reserved Reserved Numeric Keypad Enter Numeric Keypad/ F1 F2 F3 F4 F5 F6 F7 75H 72H 74H 6BH 70H
  • Honeywell MS9535-5 | Configuration Guide - Page 88
    Scan PS2 Scan Code Code Screen Multiple 00H Tab ODH OFH Shift Tab 8DH 8FH Enter 5AH 1CH ESC 76H 01H Left ALT Make 11H 36H C4H = 196 C5H = 197 * Example: 1st Configurable Prefix = 174 2nd Configurable Prefix = 065 Scanner will transmit "A" 16-8
  • Honeywell MS9535-5 | Configuration Guide - Page 89
    Stand Scan Modes ³ 120117 Short Scan In Stand - While scanning in the stand, the unit will only accept bar codes within the short IR range. ³ 120107 * Normal Scan In Stand CodeGate Status Use the following bar codes to control button functions. Note: The following functions are not supported by
  • Honeywell MS9535-5 | Configuration Guide - Page 90
    laser will blink on/off for approximately 60 seconds. ³ 418334 ³ 418344 Continuous Blinky Scan - The laser blinks continuously and the IR is inactive. This feature is not available for the VoyagerPDF series. Custom (One Shot) Scan - The laser turns off after a good decode. ³ 418354 Enable Manual
  • Honeywell MS9535-5 | Configuration Guide - Page 91
    Same Symbol Time Outs If using an MS5145 Eclipse, the MS9524 or MS9544 VoyagerPDF, go to page 7-3. No Same Symbol Time Out ³ 818900 ³ 818910 1000 msec Same Symbol Time Out ³ 818920 * 875 msec Same Symbol Time Out ³ 818930 750 msec Same Symbol Time Out ³ 818940 625 msec Same Symbol Time Out
  • Honeywell MS9535-5 | Configuration Guide - Page 92
    with Laser Emulation interface enabled. If you recall defaults while re-configuring your scanner, scan the following bar code to re-enable the Laser Emulation interface. The scanner you are using must be labeled as an MS9520-00 or MS9540-00 to support this feature. Enable HH Laser Emulation ³ 999979
  • Honeywell MS9535-5 | Configuration Guide - Page 93
    ³ 118716 Enable PDF CodeGate in Stand ³ 118706 * Disable PDF CodeGate in Stand ³ 118714 Enable PDF CodeGate Out of Stand ³ 118704 * Disable PDF CodeGate Out of Stand MicroPDF and Composite Code Handling ³ 100417 ³ 100407 Enable MicroPDF - Allows composite symbologies to be scanned (PDF 417
  • Honeywell MS9535-5 | Configuration Guide - Page 94
    UPC/EAN Linkage * Enable Code 128 Linkage - Transmit the 1D Code 128 without scanning the 2D portion. ³ 115015 ³ 115004 ³ 115014 Disable Code 128 Linkage * Enable PDF 1D Linkage - Transmit the 2D portion of the PDF-417 without scanning the 1D portion. Disable PDF 1D Linkage ³ 115003 ³ 115013
  • Honeywell MS9535-5 | Configuration Guide - Page 95
    Scan the Provide BT Service bar code (below) to place the MS9535 into service mode. In this mode, other Bluetooth wireless technology enabled devices can initiate a connection to the scanner. Provide BT Service ³ 0 0 0CA7 0 0 0 0 0 0 ³ 124316 ³ 124306 BT PIN Required - The MS9535 will require
  • Honeywell MS9535-5 | Configuration Guide - Page 96
    - Store scanned bar codes into RAM if the wireless connection has been interrupted. * Disable Range Gate Enable BT Test - The cradle will display certain connection information (KO, OK, etc.). Note: Do not enable this feature unless instructed to by a Honeywell representative. * Disable BT Test 19
  • Honeywell MS9535-5 | Configuration Guide - Page 97
    MS9535-5M VoyagerBT ³ 123910 ³ 123900 ³ 123903 ³ 123913 ³ 123901 Enable Inventory Mode - Bar code data that is scanned is stored in the scanner's expanded memory base. The data will be transmitted when the scanner is placed back into its BT cradle. Note: A special beep will sound when a bar code
  • Honeywell MS9535-5 | Configuration Guide - Page 98
    Record Counters - Will transmit the number of records and the number of bar codes currently stored as a 5-digit number separated by a space. Transmit Quantity Field - Adds an additional quantity field for the last item (bar code) scanned. Once enabled the user is able to enter a numerical quantity
  • Honeywell MS9535-5 | Configuration Guide - Page 99
    quantity bar codes will enable the user to enter a quantity from 1 to 9999 for the last item (bar code) scanned. The item's bar code data will be retransmitted as many times as the quantity indicates. Example: 1. Scan the item's bar code (ie. ABCD) 2. Scan the Quantity 1 bar code 3. Scan the
  • Honeywell MS9535-5 | Configuration Guide - Page 100
    20-4
  • Honeywell MS9535-5 | Configuration Guide - Page 101
    120315 ³ 120305 Disable Old Serial Program Enable Old Serial Program ³ 120311 Enable TTL UART ³ 120312 Enable Non Buffered TTL UART ³ 120313 Enable Detect and Notify Mode ³ 84660110 Cunningham Defaults - Scan this code followed by Recall Defaults code to enable and load Cunningham defaults
  • Honeywell MS9535-5 | Configuration Guide - Page 102
    21-2
  • Honeywell MS9535-5 | Configuration Guide - Page 103
    laser timeout selected, or receipt of a 'D' or when a bar code is scanned and transmitted. ³ 117415 Activate Scanning with Address - A configurable address character is used to initiate scanning. The scanning cycle is terminated based on the default period of time (2 seconds), variable laser
  • Honeywell MS9535-5 | Configuration Guide - Page 104
    configurable time increment (1-second increments) selected is the scanning laser-on time. ³ 120314 Allow Full Laser-On Cycle - The laser stays on for a full cycle even when a bar code is scanned ³ 119917 ³ 120303 Enable RTS No Read Pulse - A configurable RTS pulse width transmitted after
  • Honeywell MS9535-5 | Configuration Guide - Page 105
    is maintained throughout the cycle preventing additional scans of the same bar code when the scanner is in default mode. Sleep Mode ³ 919500 ~ Sleep Mode - A power saving mode that can be configured to occur in 1-second increments. Use this code with a code byte sequence (on page 16-1) that
  • Honeywell MS9535-5 | Configuration Guide - Page 106
    22-4
  • Honeywell MS9535-5 | Configuration Guide - Page 107
    . These scanners may use a different set of defaults than Honeywell factory defaults. Scanning the bar code will reset the default table to Honeywell defaults. ³ 846600 ³ 999998 Enable Factory Defaults - Scan this code followed by Recall Defaults code to enable and load Honeywell factory defaults
  • Honeywell MS9535-5 | Configuration Guide - Page 108
    the Serial Port. This will put the scanner in serial program mode. Scanning will be suspended and the scanner will respond with an ACK (06 Hex). 2. Transmit 999998 through the Serial Port. This is the Recall Defaults bar code in the MetroSelect guide. The scanner will respond with an ACK
  • Honeywell MS9535-5 | Configuration Guide - Page 109
    Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: [email protected] Latin America Telephone: (803) 835-8000 Telephone: (800
  • Honeywell MS9535-5 | Configuration Guide - Page 110
    Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the
  • Honeywell MS9535-5 | Configuration Guide - Page 111
    Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.honeywellaidc.com 24-3
  • Honeywell MS9535-5 | Configuration Guide - Page 112
  • Honeywell MS9535-5 | Configuration Guide - Page 113
  • Honeywell MS9535-5 | Configuration Guide - Page 114
  • Honeywell MS9535-5 | Configuration Guide - Page 115
  • Honeywell MS9535-5 | Configuration Guide - Page 116
    Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02544 Rev K 2/11
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

MetroSelect
®
Single-Line Scanner
Configuration Guide