Honeywell RTH111 Owner's Manual

Honeywell RTH111 Manual

Honeywell RTH111 manual content summary:

  • Honeywell RTH111 | Owner's Manual - Page 1
    the fan operation. • Auto: The fan runs only when heating or cooling is actually taking place (commonly used setting). • On: The fan runs continuously. Use this setting for improved air circulation or for more efficient air cleaning. RTH111 User Guide Non-programmable Thermostat 1.5 Temperature
  • Honeywell RTH111 | Owner's Manual - Page 2
    55 °C) Operating Relative Humidity • 5% to 90% (non-condensing) Physical Dimensions (H x W x D) • 4.7" x 2.9" x 1.1" (120 mm x 74 mm x 28 mm) 4. ; Warranty 5. Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service
  • Honeywell RTH111 | Owner's Manual - Page 3
    • Off : Le système est arrêté. • Heat : Le système est en mode Chauffage. MISE EN Utiliser le bouton-sélecteur Fan pour choisir le mode d'air. RTH111 Guide de l'utilisateur Thermostat non programmable 1.5 Réglage si les piles ont été enlevées. Installer deux piles AAA neuves lorsque l'icô
  • Honeywell RTH111 | Owner's Manual - Page 4
    le site http://yourhome.honeywell.com ou vous adresser aux Services à la clientèle de Honeywell en composant le 1 800 468-1502. Pour gagner du temps, veuillez prendre en note le numéro de modèle et le numéro de code de date du thermostat avant d'appeler. RTH111 Imprimé aux É.-U. 69-2061EFS
  • Honeywell RTH111 | Owner's Manual - Page 5
    á en modo Enfriamiento. • Off: el sistema está apagado. • Heat: el sistema está en modo Calefacción. ADVERTENCIA: PELIGRO DE DAÑAR 1.4 Botón selector del ventilador Utilizar el botón selector Fan para elegir el modo de funcionamiento del ventilador. • RTH111 69-2061EFS-01 69-2061EFS-01 11/09 5/8
  • Honeywell RTH111 | Owner's Manual - Page 6
    ; Garantía 5. Honeywell garantiza por un período de un Honeywell, al 1-800- 468-1502. dirección: Honeywell Return Honeywell será la de reparar o reemplazar el producto de acuerdo con los términos aquí establecidos. HONEYWELL HONEYWELL Honeywell Honeywell Limited/Honeywell honeywell
  • Honeywell RTH111 | Owner's Manual - Page 7
    RTH111 p Menu de configuration 3. 69-2061EFS-01 11/09 7/8
  • Honeywell RTH111 | Owner's Manual - Page 8
    RTH111 p Menu de configuration 3. 69-2061EFS-01 11/09 8/8
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

RTH111
69-2061EFS
-01
11/09
1/
8
1.1
Controls
1.2
Display screen
1.3
System switch
Use the
System
switch to place the system in one of the following
modes.
Cool
: System is in Cooling mode.
Off
: System is off.
Heat
: System is in Heating mode.
CAUTION: EQUIPMENT DAMAGE HAZARD
Do not use Cooling mode when the outdoor temperature
is below 50 °F (10 °C).
1.4
Fan switch
Use the
Fan
switch to select the fan operation.
Auto
: The fan runs only when heating or cooling is actually taking
place (commonly used setting).
On
: The fan runs continuously. Use this setting for improved air
circulation or for more efficient air cleaning.
1.5
Temperature adjustment
Press the
or
button once to display the setpoint temperature.
Press either button more than once to change the setpoint.
The ambient (measured) temperature is normally displayed. To view
the setpoint temperature, press either of the temperature adjustment
buttons once. The setpoint temperature will appear for five seconds.
1.6
Built-in compressor protection
Your thermostat has a feature that helps prevent damage to the
compressor of your air conditioning system. Because damage can
occur if the compressor is restarted too soon after shutdown, this
feature forces the compressor to wait five minutes before restarting.
During the wait time, the message
Cool On
flashes on the screen.
When the safe wait time has elapsed, the message stops flashing
and the compressor turns on.
Set the
System
switch to
Off
before removing the
batteries. Otherwise, the heating/cooling system could
remain activated even when batteries are removed.
Install two fresh AAA batteries when the low-battery icon flashes on
the screen. The icon appears for 60 days before the batteries are
depleted. Replace batteries once a year, or when you will be away for
more than a month.
The settings are stored in non-volatile (permanent) memory and are
thus saved when the thermostat is without batteries.
Operation
System switch
Fan switch
Temperature
adjustment buttons
1
When
Cool On
is flashing, this means the compressor protection is engaged (see
section 1.6).
Temperature
System status
Cool On
: Cooling is
activated.
1
Heat On
: Heating is
activated.
Low-battery warning
Setpoint indicator
Appears when the
setpoint temperature
is displayed.
Battery replacement
In case of difficulty
Screen is blank.
Ensure two fresh AAA alkaline batteries are
correctly installed.
Temperature settings
cannot be changed.
• The
System
switch is off.
You are setting the temperatures outside
their allowable ranges:
Heat: 40 °F to 90 °F (4.5 °C to 32 °C).
Cool: 50 °F to 99 °F (10 °C to 37 °C).
Cool On
is flashing.
The compressor protection delay has been
activated. Cooling will not be activated until
the delay ends (maximum of five minutes).
HI
appears on the
screen.
The ambient (measured) temperature is
above 122 °F (50 °C).
LO
appears on the
screen.
The ambient (measured) temperature is
below 32 °F (0 °C).
E1
appears on the
screen.
The temperature sensor circuit is opened.
Replace the thermostat.
E2
appears on the
screen.
The temperature sensor circuit is shorted.
Replace the thermostat.
RTH111
User Guide
Non-programmable Thermostat