Hotpoint HTX26GASWWW Quick Specs

Hotpoint HTX26GASWWW Manual

Hotpoint HTX26GASWWW manual content summary:

  • Hotpoint HTX26GASWWW | Quick Specs - Page 1
    for LP gas. LP gas supply requires an optional conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conversion at geappliances.com or call GE Answer Center® Service, 800.626.2000. Listed by Underwriters Laboratories Specification Revised 2/24
  • Hotpoint HTX26GASWWW | Quick Specs - Page 2
    HTX26GASWWW Hotpoint® 6.2 Cu. Ft. Capacity Gas Dryer with up to 120 Ft. Venting and Shallow Depth For complete information, see installation instructions packed with your dryer. DUCTING MATERIALS: For best performance, this dryer should be vented with 4" diameter all-rigid metal exhaust duct. If
  • Hotpoint HTX26GASWWW | Quick Specs - Page 3
    HTX26GASWWW Hotpoint® 6.2 Cu. Ft. Capacity Gas Dryer with up to 120 Ft. Venting and Shallow Depth FEATURES AND BENEFITS AutoDry - AutoDry monitors the internal air temperature to determine the ideal drying time, protecting your garments from overdrying. Powerful Venting & Flexible Installtion -
  • 1
  • 2
  • 3

HTX26GASWWW
Hotpoint® 6.2 Cu. Ft. Capacity Gas Dryer with up to 120 Ft. Venting and Shallow Depth
DRYER DIMENSIONS (IN INCHES)
Specification Revised 2/24
EXHAUST OPTIONS:
3-way via rear, left and bottom. Dryer is shipped
exhausted to the rear. Alternate exhausting knockouts are supplied.
CIRCUIT REQUIREMENTS:
An individual properly-grounded branch
circuit, with a three-prong grounding-type receptacle, protected by
a 15- or 20-amp circuit breaker or a time-delay fuse, is required.
GAS DRYER ELECTRIC RATING:
120V, 60Hz, 6 Amp
GAS (BTU/HR):
22,000. Factory-equipped for natural gas.
Tested for LP gas. LP gas supply requires an optional conversion
kit. Check installation instructions for correct kit and have a qualified
gas technician install a conversion kit. See dryer ducting information
for proper installation.
INSTALLATION INFORMATION:
For complete information, see
installation instructions packed with product for current dimensional data.
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be
stated on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other
surfaces are: 0" either side, 1" front, top and rear
- Closet doors must be louvered or otherwise ventilated and must contain
a minimum of 60 sq. in. of open area equally distributed. If this closet
contains both a washer and a dryer, doors must contain a minimum of
120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with
a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes,
with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
Minimum clearances to combustible surfaces 0" both sides, 1" rear.
22 3/8"
26 5/8"
3 7/8"
5"
37 1/2"
44"
SIDE VIEW
1 7/8"
3 1/8"
44"
27"
4 7/8"
POWER CORD 4 3/4"
11 3/4"
REAR VIEW
*Order online at GEApplianceparts.com, 24 hours a day or by phone at 877.959.8688 during normal business hours.
For answers to your Monogram, Café™, GE Profile™ or GE Appliances product questions, visit our website
at geappliances.com or call GE Answer Center® Service, 800.626.2000.
POWER CORDS:
GE Appliances strongly recommends
the use of factory specified parts. Select the power cord
to fit your installaton requirements.*
NOTE:
If the dryer circuit is on a circuit protected by a
GFCI breaker, then 3-wire installation is not permitted.
Hose wiring and dryer must be configured for 4-wire.
Part Number
WX9X2
WX9X3
WX9X4
WX9X18
WX9X19
WX9X20
Type
3-Prong
3-Prong
3-Prong
4-Prong
4-Prong
4-Prong
Length
4 Feet
5 Feet
6 Feet
4 Feet
5 Feet
6 Feet
Amperage
30
30
30
30
30
30
Listed by
Underwriters
Laboratories