Hotpoint RB787DPWW Quick Specs

Hotpoint RB787DPWW - Electric Range Manual

Hotpoint RB787DPWW manual content summary:

  • Hotpoint RB787DPWW | Quick Specs - Page 1
    if the range side trims extend beyond the cabinet fronts at least 1/4". Self-Clean models only connection to an electric range. Note: 30" Electric Ranges conform to Self-clean models only. Dimension from wall to door handle is 28-1/2". th2e6fr-o3n/t8o*f closed oven All Hotpoint ranges are
  • Hotpoint RB787DPWW | Quick Specs - Page 2
    RB787DP- Hotpoint 30" Free-Standing Electric Range OFF LO HI OFF LO HI OFF LO viewing area to check the progress of food • Frameless Glass Oven Door - Offers an easy-to-clean and stylish design that blends seamlessly into existing cabinetry • Model RB787DPWW - White • Model RB787DPBB - Black
  • 1
  • 2

Dimensions (in inches)
Listed by
Underwriters
Laboratories
Note:
Check local codes for required breaker size.
Effective January 1, 1996, the National Electrical Code requires
that new construction (not existing) utilize a 4-conductor
connection to an electric range.
Note:
30" Electric Ranges conform to U.L. requirements for
0" spacing from walls below countertops. Allow 1-1/2" spacing
from the side of the range to adjacent vertical walls above the
cooktop surface.
Receptacle Locations:
Locally approved flexible service cord
or conduit must be used because terminals are not accessible
after range installation. See shaded area in drawing for location
of electrical outlet box. Recommended outlet locations allow
range to be installed directly against rear wall.
Installation Information:
Before installing, consult installation
instructions packed with product for current dimensional data.
*Dimension from wall to front of closed oven door.
Dimension from wall to the front of closed oven
door handle is 28-1/2".
The range may be placed with
0" clearance (flush) at the back
wall and side walls if the range
side trims extend beyond the
cabinet fronts at least 1/4".
Self-Clean models only
Amp Rating
240V
10.5
208V
7.9
Breaker Size
40 Amps
All Hotpoint ranges are equipped
with an Anti-Tip device. The
installation of this device is an
important, required step in the
installation of the range.
CENTER LINE
2-1/4
7-1/2
7-1/2
7
5
2-1/4
3-1/2
REAR
WALL
RB787DP– Hotpoint 30" Free-Standing Electric Range
26-3/8*
46-3/8
29-7/8
46-7/8
1/4
Specification Revised 4/09
420411