Humax BLU-FOXS User Manual - Page 76

Installer Menu, Motor Limit, Enable, Disable, Limit Position, Set Limit

Page 76 highlights

10. Installation Installer Menu You can set default setting and operation limit for motor antenna. 1. Select Installer Menu from Motor Antenna Setting and press the OK button. 2. To save the present location, change the Motor Limit to Enable. ** Note: When Motor Limit is set to Enable, Limit Position and Set Limits are set to Disabled. ** • Motor Limit You can set the maximum motor limit both East and West to prevent damage to the antenna. 1. Select Motor Limit using the button. 2. Select Enable/Disable using the OK or button. Enable Disable Motor limit is set. motor does not exceed the limit. Setting is released. Note: When setting new motor limit, set to Disable. ** • Limit Position You can set the maximum motor limit both East and West to prevent damage to the antenna. 1. Select Limit Position using the button and press the OK button. 2. Select from East/West using the OK or button. East Sets East limit. West Sets West limit. ** • Set Limit 1. Select Set Limit using the button and press the OK button. 2. Move the antenna to the Limit Position to set using the OK or button. Note: When limit is set, Motor Limit is automatically set to Enable. 75