Hunter 40170 Owner's Manual

Hunter 40170 Manual

Hunter 40170 manual content summary:

  • Hunter 40170 | Owner's Manual - Page 1
    Electronic/Mechanical Thermostat installation and operation manual Model 40170 42998-01 01-19-2007
  • Hunter 40170 | Owner's Manual - Page 2
    
  • Hunter 40170 | Owner's Manual - Page 3
    Table of Contents Important Information 5 Tools 6 Uninstalling the Existing Unit 9 Installing the Thermostat 13 installing the wall plate 15 connecting the wires 17 attaching the thermostat 19 Operation 23 Indicators & Adjustments 25 Troubleshooting 28 Wiring Diagrams 30 
  • Hunter 40170 | Owner's Manual - Page 4
    Thermostat Model 40170 Congratulations! Thank you for choosing a Hunter thermostat. Your new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for complete operation instructions
  • Hunter 40170 | Owner's Manual - Page 5
    Fired Boilers Gas - Millivolt Systems Oil - Fired Boilers Oil - Fired Furnace Electric Furnace Electric Air Conditioning Single-stage Heat Pump Systems This thermostat is not designed for Multi-stage heat pump systems or 110/220 V baseboard heating systems. If you are unsure what kind of heating and
  • Hunter 40170 | Owner's Manual - Page 6
    Tools This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your new thermostat, you will need the following supplies: Flat-head screwdriver Small Phillips-head screwdriver Hammer Electric drill and 3/16" bit Two fresh 1.5 Volt (AA) size alkaline
  • Hunter 40170 | Owner's Manual - Page 7
    NOTICE! Do not disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper reconnection. 
  • Hunter 40170 | Owner's Manual - Page 8
    RC Y G W RC Y G W 
  • Hunter 40170 | Owner's Manual - Page 9
    to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices that must be removed or disengaged.) 3. Locate, but do not disconnect the wires. (If wires are not visible, they may be connected to the back of the wall plate. Some models may have doors
  • Hunter 40170 | Owner's Manual - Page 10
    if your existing thermostat is marked... label the wire with this sticker: B O G W Y RC RH RH / R / VR / 4 24 Volt RH RC / VC 24 Volt cool RC Y / C* / M air conditioning compressor Y W / H heating W G / F fan G O reversing valve cool O B reversing valve heat B 10
  • Hunter 40170 | Owner's Manual - Page 11
    and should not be used. If you have a wire marked C, do not connect it to any terminal. This wire is used only for non-battery powered thermostats. 5. Do not let the wires slip back into the wall during disconnection. You may want to secure the wires to the wall as you disconnect them. After all
  • Hunter 40170 | Owner's Manual - Page 12
    Top Cover Thermostat 12
  • Hunter 40170 | Owner's Manual - Page 13
    installing the thermostat INSTALLING THE THERMOSTAT 1. Remove the top cover from the new thermostat by pulling the two halves apart. 13
  • Hunter 40170 | Owner's Manual - Page 14
    G 14 Y RC W
  • Hunter 40170 | Owner's Manual - Page 15
    installing the thermostat, cont. INSTALLING THE WALL PLATE 2. Position the new thermostat on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no existing holes, level the thermostat and mark the wall for
  • Hunter 40170 | Owner's Manual - Page 16
    BOY B O Y G W RC RH G W RC RH 16
  • Hunter 40170 | Owner's Manual - Page 17
    installing the thermostat, cont. CONNECTING THE WIRES 1. Loosen, but do not remove, the terminal screws. Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper. If you do
  • Hunter 40170 | Owner's Manual - Page 18
    HE HG HE/HG Switch HP STD HP/STD Switch 18
  • Hunter 40170 | Owner's Manual - Page 19
    installing the thermostat, cont. ATTACHING THE THERMOSTAT 1. Locate the HE/HG switch on the wall plate. Set the switch to HG for a gas furnace or oil burner. Set the switch to HE
  • Hunter 40170 | Owner's Manual - Page 20
    20
  • Hunter 40170 | Owner's Manual - Page 21
    installing the thermostat, cont. 3. Insert two fresh AA alkaline batteries. 4. Align the top cover with the the wall plate, and snap the two halves together. 5. Restore power at the electrical panel or furnace. 21
  • Hunter 40170 | Owner's Manual - Page 22
    90 Set Temperature Slider 80 70 60 50 Fan Switch AUTO ON System Switch COOL OFF HEAT SYSTEM 22
  • Hunter 40170 | Owner's Manual - Page 23
    The System Switch determines the operating mode of the thermostat. Select Cool, Off, or Heat. 3. The Fan Switch should normally be located in the Auto position. To run the fan continuously, slide the Fan Switch to the On position. Note: In Auto , The fan will be turned on along with normal operation
  • Hunter 40170 | Owner's Manual - Page 24
    Thermometer 90 80 70 60 50 Battery Indicator 24
  • Hunter 40170 | Owner's Manual - Page 25
    3. The second warning is the Shut-down Indicator, indicated by the Battery Indicator flashing approximately twice every second. When this warning appears, the thermostat is shut down and will turn your system OFF. Your system will remain shut-off until you install two fresh AA alkaline batteries. 25
  • Hunter 40170 | Owner's Manual - Page 26
    Span Adjust SPAN SPAN 26
  • Hunter 40170 | Owner's Manual - Page 27
    run LONGER, turn the Span Adjust clockwise. 3. To make your system run SHORTER, turn the Span Adjust counter clockwise. 4. Reattach the top cover to the thermostat. Note: The Span range is 0.6oF - 3oF. The Span setting remains the same in both the Heat and Cool modes and can be changed regardless
  • Hunter 40170 | Owner's Manual - Page 28
    AA alkaline batteries. 1 e. If applicable, make sure the furnace blower door is closed properly. 1 f. If your system has 4 wires, ensure the jumper wire is installed between the RC and RH terminals. 2. My system continues to operate when the thermostat is in the off position. 2 a. Replace unit. 28
  • Hunter 40170 | Owner's Manual - Page 29
    troubleshooting Is there help on the web? Yes. Visit http://www.hunterfan.com for more information. Can't I just call someone? Sure. Our Technical Support Group is available from 8 am to 5 pm CST. They may be reached toll-free at 1-888-830-1326. 29
  • Hunter 40170 | Owner's Manual - Page 30
    4-wire Heat/Cool System Jumper G Fan Relay Rc Rh Y W X Heat/Cool Cool Heat Relay 24V Supply Contactor or Valve 5-wire Heat/Cool System G Rc Rh Y W Fan Relay Cool Heat Cool Heat Relay 24V Supply 24V Supply Contactor or Valve 30
  • Hunter 40170 | Owner's Manual - Page 31
    wiring diagrams Single-stage Heat Pump System Jumper G Fan Relay Rc Rh O B W Y X Heat/Cool 24V Supply Cool Mode OR Heat X Mode Reversing Valve Compressor Contactor 2-wire Heat Only System Jumper Rc Rh W X Heat 24V or Millivolt Supply Heat Relay or Valve 31
  • Hunter 40170 | Owner's Manual - Page 32
    wiring diagrams, cont. 3-wire Heat Only System Jumper G Rc Rh W Fan Relay X Heat 24V Supply Heat Relay or Valve 3-wire Cool Only System Jumper G Rc Rh Y Fan Relay X Cool 24V Supply Cool Contacter 32
  • Hunter 40170 | Owner's Manual - Page 33
    33 © 2007 Hunter Fan Company
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

Electronic/Mechanical
°ermostat
Model 40170
installation and
operation manual
42998-01
01-19-2007