Hunter 42999 Owner's Manual

Hunter 42999 Manual

Hunter 42999 manual content summary:

  • Hunter 42999 | Owner's Manual - Page 1
    SINCE ® 1 8 8 6 42999/44050 OwnerÕs Manual
  • Hunter 42999 | Owner's Manual - Page 2
    Other Quality Products from Hunter Fans Air Purifiers Humidifiers
  • Hunter 42999 | Owner's Manual - Page 3
    Mounting Thermostat 14 System Selector Switches 14 Operation Start-Up 16 Reviewing Current Temperature Setting 16 Setting New Temperature 17 Filter Monitor 18 Resetting Filter Counter To Zero 19 Temperature Span 19 Backlighting 19 Trouble Shooting 20 Typical Wiring Diagrams 22
  • Hunter 42999 | Owner's Manual - Page 4
    following the instructions on page 14. This can be done while you relax in your favorite chair and is a very good way to familiarize yourself with all the functions of your Hunter Thermostat. OPERATION 4 Your Hunter Thermostat is designed to operate with most gas, oil, electric or 2-wire hot water
  • Hunter 42999 | Owner's Manual - Page 5
    programs and current time. BATTERY WARNING 8When the batteries are low the "LOW BATT" indicator on the display will flash. When this happens, install new batteries immediately. Once the "LOW BATT" indicator appears, the thermostat will continue to operate for approximately 30 days. (Only alkaline
  • Hunter 42999 | Owner's Manual - Page 6
    Features (Model 42999) 6-7 69 TEMP SET TEMP C FILTER LO BAT HOLD HEAT COOL s Easy-To-Read Digital Display Liquid crystal display shows room temperature, set temperature, filter indicator, low battery indicator, heat and cool system indicator. s Unique Filter Monitor Automatically reminds
  • Hunter 42999 | Owner's Manual - Page 7
    Model 44050) 69 TEMP SET TEMP C FILTER LO BAT HOLD HEAT COOL s Easy-To-Read Digital Display Liquid crystal display shows room temperature, set temperature, filter indicator, low and cooling system. s Fan ON and AUTO Selector Switch. s Reset Button For resetting thermostat. s To reset filter
  • Hunter 42999 | Owner's Manual - Page 8
    To install your unit, you should have the following tools and materials. s Slotted screwdriver s Hammer s Electric drill and 3/16" bit s Two 1.5V (AA) Size Alkaline batteries Remove Old Thermostat CAUTION: Do not remove any wiring from existing thermostat before reading the instructions carefully
  • Hunter 42999 | Owner's Manual - Page 9
    TYPICAL HOME THERMOSTATS FIGURE 1 Wall Mounting Plate Thermostat Cover Wall Mounting Plate Thermostat Cover
  • Hunter 42999 | Owner's Manual - Page 10
    Installation 10-11 Label Wires s Each wire coming from the wall to the existing thermostat is connected to a terminal point on that thermostat. Each of these terminal points is usually marked with a code letter as shown in Table A on page 9. s The number of wires in your system can be as few as
  • Hunter 42999 | Owner's Manual - Page 11
    you can attach them to your Hunter Thermostat. If the code letter on your existing thermostat is RH, R, VR or 4 24 Volt RC, VC 24 Volt Cool NOTE: Follow the labels when connecting wires since many installations do not follow color coding of wires. G or F Fan Y, C or M (See Note) Air Conditioning
  • Hunter 42999 | Owner's Manual - Page 12
    Installation 12-13 Wire Labeling (Continued) NOTE: If your thermostat has one wire marked R or RH (4-wire system), then leave the jumper wire between the RH and RC terminals. Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC
  • Hunter 42999 | Owner's Manual - Page 13
    for plastic anchors provided if existing holes do not line up with Hunter Thermostat holes. Drill holes with 3/16" bit and gently tap anchors into the holes until flush with wall. Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws provided into wall anchor and
  • Hunter 42999 | Owner's Manual - Page 14
    gas and most other systems. "HE" position is for certain electric systems having a fan relay. s F°/C° selector (Fahrenheit/Centigrade) Your thermostat is set the thermostat will not change the mode. Connect Wires and Mount Thermostat Cover to Wall Plate s Match and connect the labeled wires to
  • Hunter 42999 | Owner's Manual - Page 15
    room temperature of your house. If it shows random numbers or partial HEAT OFF COOL AUTO FAN RESET digits, press the reset button once again. s The installation is now complete. Continue reading Owner's Manual for complete operating instructions. RH RH RC RH G W Y FIGURE 3 FIGURE 4 FIGURE
  • Hunter 42999 | Owner's Manual - Page 16
    the installation instructions, press the Reset Button. s The thermostat is preset at the factory to 68°F (20°C) for heat and 78°F (25°C) for cool. s Room temperature is displayed. s Your thermostat batteries will prevent memory loss and avoid reprogramming. Replace batteries as soon as low battery
  • Hunter 42999 | Owner's Manual - Page 17
    s Press arrow to display current temperature setting. 68°F is the current temperature setting. TEMP 68 SET TEMP F FILTER LO BAT HOLD HEAT COOL s After 3 seconds, "SET" starts flashing and temperature digits will increase. s Release at 72°F. TEMP 7 2 SET TEMP F FILTER LO BAT HOLD HEAT
  • Hunter 42999 | Owner's Manual - Page 18
    Filter Monitor The Hunter Digital Thermostat measures and stores the amount of time the heating or air conditioning system operated. After 500 hours of usage, the word "FILTER" will appear and flash on the display, reminding you to check or replace your system filter. 69 TEMP SET TEMP c FILTER
  • Hunter 42999 | Owner's Manual - Page 19
    counter will not reset. Temperature Span Your thermostat is pre-programmed at the factory to cycle when the temperature rises 1° above or 1° below the temperature setting. It cannot be changed. Backlighting (Model 44050 only) Press LIGHT Your thermostat comes with an electroluminescent lamp for
  • Hunter 42999 | Owner's Manual - Page 20
    Troubleshooting Problem SCRAMBLED OR DOUBLE DISPLAY (numbers over numbers NO DISPLAY ENTIRE DISPLAY DIMS AUTO/FAN DOES NOT COME ON HEATING OR COOLING DOES NOT GO ON door is closed properly. 6. If your system only uses 4-wires, be sure the jumper wire is installed between the RC and RH terminals.
  • Hunter 42999 | Owner's Manual - Page 21
    a small pin and hold in for two seconds. Then reprogram. IF UNIT CONTINUES TO OPERATE IN OFF 1. Replace unit. POSITION THERMOSTAT READS , HI, LO PERMANENTLY 1. Replace unit. If you experience any other problems, call 1-901-745-9222 from 8AM to 5PM Central Standard time for technical assistance.
  • Hunter 42999 | Owner's Manual - Page 22
    Wiring Diagrams 22-23 4-wire Heat/Cool System THERMOSTAT Jumper RC RH G W Y Heat/Cool Transformer Fan Heat Relay Cool Relay or Valve Contactor 5-wire Heat/Cool System THERMOSTAT RC RH G W Y Cool Heat Fan Heat Relay Cool Transformer Transformer Relay or Valve Contactor
  • Hunter 42999 | Owner's Manual - Page 23
    2-wire Heat Only THERMOSTAT RC RH G W Y 3-wire Heat Only Heat Transformer Heat Relay or Valve THERMOSTAT RC RH G W Y 3-wire Cool Only Heat Fan Transformer Relay Heat Relay or Valve THERMOSTAT RC RH G W Y Cool Fan Transformer Relay Cool Contactor
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

Owner°s Manual
42999/44050
SINCE
1 8 8 6
®