  • Hunter 81003 | Owner's Manual - Page 1
    Ashbury Bath Ventilator with Light English 41937-01 20101026 ©2010 Hunter Fan Co. Owner's Manual Model 81003 1 41937-01 10/26/2010
  • Hunter 81003 | Owner's Manual - Page 2
    SERVICE PANEL BEFORE SERVICING UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service. Disconnect the power supply and clean the fan to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. COOKING AREA
  • Hunter 81003 | Owner's Manual - Page 3
    Check all the parts. If damaged, call 1-888-830-1326 for replacements. x4 A *B *C 3/8" Cable -214 for model 81001 96397-02-444 for model 81003 M 75184-01-133 N 86812-01-000 O 75733-01-214 for model 81001 75733-01-444 for model 81003 Included. Before Installation 1 Tools Needed. (Not supplied
  • Hunter 81003 | Owner's Manual - Page 4
    3 4 H E Remove the motor/blower from the housing. 5 Remove packing material. 6 Remove the pre-loaded screw tip covers. 7 G Back out the pre-loaded screw tips until flush with the side of the housing. 8 F Remove the wiring cover screw. 4 41937-01 10/26/2010 Remove the wiring cover.
  • Hunter 81003 | Owner's Manual - Page 5
    9 10 E C Pop out the first wiring access slug. Use second if needed. B Insert the strain relief (not included) into the housing and secure with washer. Choose Installation Option For New Construction - go to step A11, page 5 For Existing Construction - go to step B11, page 8 New Construction
  • Hunter 81003 | Owner's Manual - Page 6
    wires through the strain relief. For supply connection, use wires suitable for at least 90º C (194º F). A14 Fan Motor Light 2 Pin Black White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In
  • Hunter 81003 | Owner's Manual - Page 7
    A17 0 A18 0 Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. H Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. A19 A20 I Secure the motor by tightening the 2 screws.
  • Hunter 81003 | Owner's Manual - Page 8
    Existing Construction B11 EXISTING FAN B12 E Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (7 1/4"x 7 3/4"). Move the housing into position above the ceiling. B13
  • Hunter 81003 | Owner's Manual - Page 9
    Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. B17 B18 F G Install the
  • Hunter 81003 | Owner's Manual - Page 10
    B21 Turn on the power source. B23 Go to step C1 on page 10 to attach grille. B22 ON OFF Test the motor. If the motor does not run, check the plug connection. Attaching the Grille C1 C2 L M Remove the thumbscrews. 10 41937-01 10/26/2010 N O Remove glass dome.
  • Hunter 81003 | Owner's Manual - Page 11
    C3 C4 L K Connect wiring harness. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS. Remove the strain relief bracket screw. C5 C6 J Position the strain relief bracket under the motor as shown. C7 Insert the strain relief bracket's dog-leg tab so that it hooks over the lip of the
  • Hunter 81003 | Owner's Manual - Page 12
    C9 C10 Install 2 Max 60 Watt A15 bulbs (Not Included). C11 N Align glass dome and push up. O Screw glass dome into position. 12 41937-01 10/26/2010
  • Hunter 81003 | Owner's Manual - Page 13
    the wiring to make sure it matches the wiring diagram. Problem: Fan is noisy. Solution: • Check and tighten all fasteners. • Check the glass to make sure it is secure. • Check the flapper to make sure it moves freely. If you need parts or service assistance, please call 888-830-1326 or visit us
  • Hunter 81003 | Owner's Manual - Page 14
    performed at our nearest service center or at our Service Department in Memphis, Tennessee. After this one-year period, you will be responsible for all parts and labor costs for repairs on the bath exhaust fan except for motor repairs as provided below. If your Hunter bath exhaust fan motor fails at