Hunter 81030 Owner's Manual
Hunter 81030 Manual
View all Hunter 81030 manuals
Add to My Manuals
Save this manual to your list of manuals |
Hunter 81030 manual content summary:
- Hunter 81030 | Owner's Manual - Page 1
Halcyon Bath Ventilator with Light English Español Página 22 43034-01 20110908 ©2011 Hunter Fan Co. Owner's Manual Model 81030 1 43041-01 09/12/2011 - Hunter 81030 | Owner's Manual - Page 2
and Air 9. Install fan at least 5 feet (1.52 m) above the floor. 10. This unit must be grounded. 11. Unit must not be installed in a ceiling thermally insulated to a value greater than R40. ! CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials - Hunter 81030 | Owner's Manual - Page 3
Check all the parts. If damaged, call 1-888-830-1326 for replacements. x4 A *B *C 3/8" Cable Connector x2 I Extra Screws * NOTE: Strain relief cable connector must be installed. Not Included. D 95044- - Hunter 81030 | Owner's Manual - Page 4
3 4 H E Remove the motor/blower from the housing. 5 Remove packing material. 6 Remove the pre-loaded screw tip covers. 7 G Back out the pre-loaded screw tips until flush with the side of the housing. 8 F Remove the wiring cover screw. 4 43034-01 09/12/2011 Remove the wiring cover. - Hunter 81030 | Owner's Manual - Page 5
9 10 E C Pop out the first wiring access slug. Use second if needed. B Insert the strain relief into the housing and secure with the washer. Choose Installation Option For New Construction - attaching to joist go to step A11, page 5 For New Construction - suspended between joists go to step - Hunter 81030 | Owner's Manual - Page 6
Motor Light 2 Pin Black White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. A15 A16 E F G Install the - Hunter 81030 | Owner's Manual - Page 7
A17 0 A18 0 Connect wiring from the motor to the wiring cover plate. A19 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. A20 I Secure the motor by tightening the 2 screws. Turn on the power source. - Hunter 81030 | Owner's Manual - Page 8
New Construction - suspended between joists B11 B12 E D Slide the mounting rails into brackets. 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. B13 B14 1/8" Bit E Mark position of screws by using holes as a - Hunter 81030 | Owner's Manual - Page 9
B17 B18 Tighten screws. Pull wires through the strain relief. B19 Fan Motor Light 2 Pin Black White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. B20 B21 - Hunter 81030 | Owner's Manual - Page 10
B22 B23 H H Connect wiring from the motor to the wiring cover plate. B24 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. B25 I Secure the motor by tightening the 2 screws. Turn on the power source. - Hunter 81030 | Owner's Manual - Page 11
Existing Construction - accessible from above C11 EXISTING FAN NO EXISTING FAN OR Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8"x 8.5"). Use the motor housing as a template to mark position. - Hunter 81030 | Owner's Manual - Page 12
C15 C16 1/8" Bit Drill a hole in the center of each outline. C17 Insert screws, leaving space between the screw head and the joist. Screws are not provided. C18 Attach the rails onto the screws. C19 Tighten screws. C20 Connect 4" duct and vent to the outside. Tape joints. If ducting does not - Hunter 81030 | Owner's Manual - Page 13
Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. C23 C24 F H G Install the - Hunter 81030 | Owner's Manual - Page 14
C25 C26 H Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. I Secure the motor by tightening the 2 screws. C27 C28 ON OFF Turn on the power source. C29 Test the motor. If the motor does not run, - Hunter 81030 | Owner's Manual - Page 15
Existing Construction - accessible only from below D11 EXISTING FAN D12 E Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8"x 8.5"). Move the housing into position above the ceiling. D13 D14 2 1 Pull wires through strain relief - Hunter 81030 | Owner's Manual - Page 16
Motor Light 2 Pin Black White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. D17 D18 F G Install the - Hunter 81030 | Owner's Manual - Page 17
D21 Turn on the power source. D23 Go to step E1 on page 17 to attach grille. D22 ON OFF Test the motor. If the motor does not run, check the plug connection. Attaching the Dome Assembly E1 E2 K L Remove the thumbscrews. 17 43034-01 09/12/2011 Connect wiring harness. - Hunter 81030 | Owner's Manual - Page 18
E3 E4 J K Remove the strain relief bracket screw. E5 Position the strain relief bracket under the motor as shown. E6 Insert the strain relief bracket's dog-leg tab so that it hooks over the lip of the motor. Reinstall the strain relief bracket screw. Align posts A, B, C and D (stamped into - Hunter 81030 | Owner's Manual - Page 19
E9 E10 Assemble the grille, glass dome, washer, and barrel nut as shown. Tighten the barrel nut "finger-tight." NOTE: The washer must be oriented as shown. L Screw the dome assembly dome into position. Complete. 19 43034-01 09/12/2011 - Hunter 81030 | Owner's Manual - Page 20
Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug connections - Hunter 81030 | Owner's Manual - Page 21
performed at our nearest service center or at our Service Department in Memphis, Tennessee. After this one-year period, you will be responsible for all parts and labor costs for repairs on the bath exhaust fan except for motor repairs as provided below. If your Hunter bath exhaust fan motor fails at - Hunter 81030 | Owner's Manual - Page 22
Halcyon Ventilador para baño con luz Español 43034-02 20110909 ©2011 Hunter Fan Co. Manual del Propietario Modelo 81030 22 43034-02 09-12-2011 - Hunter 81030 | Owner's Manual - Page 23
EL VENTILADOR, EL MOTOR/SOPLADOR Y EL INTERIOR DEL ALOJAMIENTO. ÁREA DE LA COCINA No instale sobre o dentro de esta área 45° 45° LAS PARTES METÁLICAS ELÉCTRICAS NUNCA DEBEN SUMERGIRSE EN AGUA. MANTENIMIENTO EL MOTOR/SOPLADOR ESTÁ LUBRICADO PERMANENTEMENTE Y NO NECESITA SER ENGRASADO. SI LOS - Hunter 81030 | Owner's Manual - Page 24
VVeerriiffiiqquuee ttooddooss llooss ccoommppoonneenntteess.. SSii eessttáánn ddaaññaa-ddooss,, llllaammee aall 11--886666--440055--33881144 ppaarraa oobbtteenneerr uunn rreeeemmppllaazzoo.. D 95044-01-000 E 95029-01-000 F 77481-01-000 x4 A *B *C Conector de cable de 3/8" x2 I Tornillos - Hunter 81030 | Owner's Manual - Page 25
3 4 I F Retire el motor/soplador/soplador del alojamiento. Retire el material de embalaje. 5 6 Retire las cubiertas de las puntas de tornillo precargadas. 7 Retire las puntas de tornillo precargadas hasta que estén a nivel con el lado del alojamiento. 8 F G Retire el tornillo de la - Hunter 81030 | Owner's Manual - Page 26
9 10 E C Retire el primer tapón metálico de acceso del cableado. Utilice el segundo si es necesario. B Inserte el manguito de alivio de tensión (no se incluye) en la caja y sujételo firmemente con una arandela. Escoja la opción de instalación Para construcción nueva - fijación a la viga, vaya - Hunter 81030 | Owner's Manual - Page 27
A13 Tienda los cables a través del manguito de alivio de tension. A14 Negro 2 2 pascaladvoijraess Blanco Motor del ventilador Blanco 3 3 Luz pascaladvoijraess Negro Luz *Opción *Opción Ventilador y luz principal juntos Tierra Verde A Cobre desnudo Negro Interruptor principal 1 (CA) - Hunter 81030 | Owner's Manual - Page 28
A17 0 A18 0 Conecte el mazo de cables. NO PERMITA QUE EL MOTOR/SOPLADOR CUELGUE DEL MAZO DE CABLES. A19 Vuelva a instalar el motor/soplador introduciendo las pestañas y levantando a su posición. Asegúrese que los alambres no se pellizquen entre el motor/soplador y el alojamiento. A20 I Asegure - Hunter 81030 | Owner's Manual - Page 29
Construcción nueva - suspendido entre vigas B11 B12 E D Deslice los rieles de montaje en los soportes. B13 5/8 5/8 1/2 1/2 Ubique la correcta marca de profundidad en el borde inferior de la viga, según el espesor de su plancha de yeso. B14 1/8" Bit E Marque la posición de los tornillos - Hunter 81030 | Owner's Manual - Page 30
B17 B18 Apriete los tornillos. Tienda los cables a través del manguito de alivio de tension. B19 Negro 2 2 pascaladvoijraess Blanco Motor del ventilador Blanco 3 3 Luz pascaladvoijraess Negro Luz *Opción *Opción Ventilador y luz principal juntos Tierra Verde A Cobre desnudo Negro - Hunter 81030 | Owner's Manual - Page 31
B22 B23 H H Conecte el mazo de cables. NO PERMITA QUE EL MOTOR/SOPLADOR CUELGUE DEL MAZO DE CABLES. B24 Vuelva a instalar el motor/soplador introduciendo las pestañas y levantando a su posición. Asegúrese que los alambres no se pellizquen entre el motor/soplador y el alojamiento. B25 I Asegure - Hunter 81030 | Owner's Manual - Page 32
Construcción existente - accesible desde arriba C11 VENTILADOR EXISTENTE SIN VENTILADOR EXISTENTE O Retire el ventilador existente y asegúrese que la abertura sea suficientemente grande para acomodar el alojamiento del motor/soplador nuevo (8 pulg. x 8 1/2 pulg.). Utilice el alojamiento del - Hunter 81030 | Owner's Manual - Page 33
C15 C16 broca de 1/8 de pulg. Taladre un agujero en el centro de cada perfil. C17 Introduzca los tornillos, dejando espacio entre la cabeza del tornillo y la viga. No se proporcionan los tornillos. C18 Fije los rieles con los tornillos. C19 Apriete los tornillos. C20 Conecte un ducto de 4" y - Hunter 81030 | Owner's Manual - Page 34
C21 Apriete los tornillos del aliviador de tensiones. C22 Negro 2 2 pascaladvoijraess Blanco Motor del ventilador Blanco 3 3 Luz pascaladvoijraess Negro Luz *Opción *Opción Ventilador y luz principal juntos Tierra Verde A Cobre desnudo Negro Interruptor principal 1 (CA) Blanco Negro - Hunter 81030 | Owner's Manual - Page 35
C25 C26 H I Vuelva a instalar el motor/soplador introduciendo las pestañas y levantando a su posición. Asegúrese que los alambres no se pellizquen entre el motor/soplador y el alojamiento. Asegure el motor/soplador apretando los 2 tornillos. C27 C28 ENCENDIDO APAGADO Encienda la fuente de - Hunter 81030 | Owner's Manual - Page 36
Construcción existente - accesible sólo desde abajo D11 VENTILADOR EXISTENTE D12 E Retire el ventilador existente y asegúrese que la abertura sea suficientemente grande para acomodar el alojamiento del motor/soplador nuevo (8 pulg. x 8 1/2 pulg.). D13 Mueva el alojamiento a su posición encima - Hunter 81030 | Owner's Manual - Page 37
D16 Negro 2 2 pascaladvoijraess Blanco Motor del ventilador Blanco 3 3 Luz pascaladvoijraess Negro Luz *Opción *Opción Ventilador y luz principal juntos Tierra Verde A Cobre desnudo Negro Interruptor principal 1 (CA) Blanco Negro Interruptor 2 (CA) Conecte los alambres como se muestra. - Hunter 81030 | Owner's Manual - Page 38
D21 Encienda la fuente de alimentación. D23 Vaya al paso E1 en la página 37 para jar la rejilla. D22 ENCENDIDO APAGADO Pruebe el motor/soplador. Si el motor/soplador no funciona, verifique la conexión del enchufe. Fijación de la rejilla E1 E2 K L Retire los tornillos de mano. Conecte el - Hunter 81030 | Owner's Manual - Page 39
Retire el tornillo del soporte del aliviador de tensiones. Coloque el soporte del aliviador de tensiones (3) debajo del motor como se muestra. E5 E6 Introduzca la pestaña en ángulo del soporte del aliviador de tensiones para que se enganche en el borde del motor. Reinstale el tornillo del - Hunter 81030 | Owner's Manual - Page 40
E9 E10 Ensamble la rejilla, domo de vidrio, arandela y manguito de tuerca como se muestra. Apriete el manguito de tuerca "a mano." NOTA: Las arandelas deben estar orientadas como se muestra. L Atornille el conjunto del domo en su posición. Completo. 40 43034-02 09-12-2011 - Hunter 81030 | Owner's Manual - Page 41
Solución de problemas Problema: El ventilador no está operando. Solución: • Los ventiladores de baño Hunter son muy silenciosos. Para confirmar que el ventilador esté funcionando, coloque su mano cerca de los conductos de ventilación para sentir el movimiento del aire. • - Hunter 81030 | Owner's Manual - Page 42
odo de cinco años, usted será responsable de todos los costos de partes y mano de obra para reparaciones de cualquier componente del Extractor de aire que establezca la prueba de su compra. EN NINGÚN CASO HUNTER FAN COMPANY SERÁ RESPONSABLE DE DAÑOS PERJUDICIALES O ACCESORIOS. ALGUNOS ESTADOS
43041-01
09/12/2011
1
Bath Ventilator with Light
Owner’s Manual
Halcyon
43034-01
20110908
©2011 Hunter Fan Co.
Model
81030
English
Español
Página 22