Hunter 82029 Installation Manual

Hunter 82029 Manual

Hunter 82029 manual content summary:

  • Hunter 82029 | Installation Manual - Page 1
    Spa Select •ned Bath Ventilation Fan Installation Manual rn ta (z.71-- Model 82029 •SOU ,S1Vt ti 1886
  • Hunter 82029 | Installation Manual - Page 2
    information and requirements. AWARNING DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service. Disconnect the power supply and dean the fan as listed below. TO CLEAN GRILLE: Use a mild detergent, such as
  • Hunter 82029 | Installation Manual - Page 3
    Check all the parts. If damaged, call 1-888430-1326 for replacements. • n'Cab:o Coln:it:cc * OPP. x3 1:* x2 l>• c7 Exba SUC'AS * NOTE: Strain relief cable connector must be installed. Not Included. ro* 95047-01-000 1100, 03242-07-133 D O p 95374.01-000 74508-03-133 x2 Ito. 94998-01/02-000
  • Hunter 82029 | Installation Manual - Page 4
    New Construction Installation A2 A3 Remove tape. Remove the motorIblower from the housing. A Remove packing material. A5 Remove the pre-loaded screw tip covers. Lfr ) Back out the pre4oaded screw tips until flush with the side of the housing. 4 48084-01 07/07/09 Remove the wiring cover screw.
  • Hunter 82029 | Installation Manual - Page 5
    A • • Remove the wiring cover. Pop out the first wiring access slug. Use second if needed. I re Insert the strain relief into the housing and secure with the washer. All - _518 - 1/2 -5/8 112 Position the correct depth mark at the bottom edge of the joist-based on the thickness of your sheet
  • Hunter 82029 | Installation Manual - Page 6
    r t% Pull the wires through the strain relief. Ground Green Bare Copper Black White Connect wires as shown. Tighten the strain relief screws. a Dry D Install the wiring cover plate. Make sure all wiring connec• Lions are inside the box or under the wiring cover plate. 6 Connect a 4" duct and
  • Hunter 82029 | Installation Manual - Page 7
    . Turn on the power source. t Opp Test the motor. If the motor does not run, check the plug connection. Insert one spring clip of the fan cover into the slot on the motor housing. 7 48084-01 07/07/09
  • Hunter 82029 | Installation Manual - Page 8
    . Existing Construction Installation "ss Use the motor housing as a template to mark position. Cut out an opening for the housing. B1 Remove the existing fan and check to make sure the opening is large enough to accommodate the new motor housing (7.25" x 7.75"). 8 48084-01 07/07/09 Remove
  • Hunter 82029 | Installation Manual - Page 9
    B2 B3 Remove the motor/blower from the housing. a a Remove packing material. Remove the pre-loaded screw tip covers. a Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover screw. 9 48084-01 07/07/09 Remove the wiring cover.
  • Hunter 82029 | Installation Manual - Page 10
    • S • V • Pop out the first wiring access slug. Use second if needed. B10 Insert the strain relief into the housing and secure with the washer. Move the housing into position above the ceiling. B12 Pull the wires through the strain relief and tighten the strain relief screws. a I Attach
  • Hunter 82029 | Installation Manual - Page 11
    B14 4 Connect the wiring. • Ground Green Bare Copper Black White Connect wires as shown. a Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. • • Connect wiring from the motor to the wiring cover plate. • qr. 8 a O
  • Hunter 82029 | Installation Manual - Page 12
    B2O B21 y Turn on the power source. OFF Test the motor. If the motor does not run, check the plug connection. B23 cc, \* Insert one spring clip of the fan cover into the slot on the motor housing. Push the cover into place. 12 48084-01 07/07/09
  • Hunter 82029 | Installation Manual - Page 13
    Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand flapper to make sure it moves freely. If you need parts or service assistance, please call 888-830-1326 or visit us at our WEB site at http
  • Hunter 82029 | Installation Manual - Page 14
    at our nearest service center or at our Service Department in Memphis, Tennessee. After this one-year period, you will be responsible for all parts and labor costs for repairs on the bath exhaust fan except for motor repairs as provided below. •If your Hunter bath exhaust fan motor fails at
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

Spa
Select
•ne
d
Bath
Ventilation
Fan
Installation
Manual
rn
ta
(.71
-
z-
Model
82029
,S1Vt
ti
1886
•SOU