    Installation Guide ENGLISH See page 2 Español Vea la página 19 Energy Star Bath Fan Models 82030, 82031, & 82032 READ and SAVE THESE INSTRUCTIONS  42935-01 06/04/2007
  • Hunter 82032 | Owner's Manual - Page 2
    manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. SAVE THESE INSTRUCTIONS. 2) Before installing, servicing Figure A. NOTE: This illustration is not to scale Bath Fan 3 ft. min. (0.91 m) Tub or Shower area 42935-01 06/04/2007 Figure A
  • Hunter 82032 | Owner's Manual - Page 3
    to a 12/12 pitch (45 degrees). Ductwork must point upward. 10) Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight drywall spray, construction dust, etc. off power unit. 13) Read specification label on product for further information and requirements. 14) Do not
  • Hunter 82032 | Owner's Manual - Page 4
    97118-05-000 x2 M 74508-03-133 N 97934-01-262 Wiring Cover Wiring Cover Screw Strain Relief Bracket Strain Relief Bracket Screw Fan Assembly Fan Mounting Screws Bezel Included. Before Installation A Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes B Turn off the power
  • Hunter 82032 | Owner's Manual - Page 5
    C D Remove the fan assembly from the housing. E Loosen the wiring cover screw. Remove the wiring cover. Choose Installation Option For New Construction - attaching to joist, go to step
  • Hunter 82032 | Owner's Manual - Page 6
    Section A - New Construction - attaching to joist A1 OR Pop out a wiring access slug. A2 A3 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the joist based upon the the thickness of your sheetrock. Drive mounting screws (supplied) into joist or framing. A4 A5 3" Run
  • Hunter 82032 | Owner's Manual - Page 7
    A6 Go to Section E Final Installation on page 14. Connect 4" duct and vent to the outside. Use duct tape to secure joints. If ducting does not fit securely, an adapter may need to be purchased. Section B - New Construction - suspended between joists B1 OR Pop out a wiring access slug. B2 B3 5/8
  • Hunter 82032 | Owner's Manual - Page 8
    B4 B5 1/16" bit Mark position of screws by using holes as a template. Drill a pilot hole at the TOP of each outline. B6 B7 Insert mounting screws, leaving space between the screw head and the joist. (Screws are supplied.) Attach the rails onto the screws. B8 B9 3" Tighten screws. 42935-
  • Hunter 82032 | Owner's Manual - Page 9
    Final Installation on page 14. Section C - Existing Construction - accessible from above C1 NO EXISTING FAN 11" 9 �⁄�" OR Remove an existing fan and check to make sure the opening is large enough to accommodate the new fan housing. The opening needs to be 11" x 9 5/8".  42935-01 06/04/2007
  • Hunter 82032 | Owner's Manual - Page 10
    C2 OR Pop out a wiring access slug. C3 C4 Slide the mounting rails into brackets. C5 5/8 5/8 1/2 1/2 Using the depth markings on the housing, position the bottom edge of the housing so that it will be flush with the sheetrock. C6 Mark position of screws by using holes as a template. Drill
  • Hunter 82032 | Owner's Manual - Page 11
    C7 C8 Insert mounting screws, leaving space between the screw head and the joist. (Screws are supplied.) Attach the rails onto the screws. C9 C10 3" Tighten screws. C11 Run the power supply wire through the strain relief, leaving 3" between the end of the wire and the strain relief. Tighten
  • Hunter 82032 | Owner's Manual - Page 12
    access plug if needed. Remove the mounting rail brackets. D3 EXISTING FAN D4 3" Remove an existing fan and check to make sure the opening is large enough to accommodate the new fan housing. If there is no existing fan choose an appropriate location to make an 11" x 9 5/8" opening. 42935-01
  • Hunter 82032 | Owner's Manual - Page 13
    D5 D6 Install the wiring and the strain relief into the wiring access hole you made earlier. D7 Connect 4" duct and vent to the outside. Use duct tape to secure joints. If ducting does not fit securely, an adapter may need to be purchased. D8 Move the housing into the ceiling. D9 5/8 5/8 1/2
  • Hunter 82032 | Owner's Manual - Page 14
    is mounted to a joist or suspended between joists. E3 E4 Connect fan wiring harness. DO NOT ALLOW THE FAN TO HANG FROM THE WIRING HARNESS. E5 Install the fan assembly by inserting the tabs as shown and pushing the fan assembly into the housing. Make certain the wiring is not pinched between
  • Hunter 82032 | Owner's Manual - Page 15
    E7 E8 Install the bezel by inserting the wire clips into the tabs on the inside of the housing. E9 Complete. Restore power at the source. 15 42935-01 06/04/2007
  • Hunter 82032 | Owner's Manual - Page 16
    Preventative Maintenance A clean fan provides better service. Disconnect the power supply and clean the fan as listed below. TO CLEAN THE or unusual noises, contact Hunter Technical Support (see Troubleshooting section) to order a new fan assembly. Trouble Shooting Problem: Fan does not come on.
  • Hunter 82032 | Owner's Manual - Page 17
    . To obtain servicing, contact Hunter Fan Company Technical Support at 1-888-830-1326. Please contact us before shipping your Bath Fan to us. If WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. Hunter Fan Company 2500 Frisco Avenue
  • Hunter 82032 | Owner's Manual - Page 18
    42935-01 06/04/2007 18
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

42935-0±
06/04/2007
I
n
s
t
a
l
l
a
t
i
o
n
G
u
i
d
e
Energy Star Bath Fan Models 82030, 8203±, & 82032
READ and SAVE THESE INSTRUCTIONS
ENGLISH
See page 2
ESPAñOL
Vea la página ±9