IBM 84885BU User Manual - Page 112

code/symptom

Page 112 highlights

Note: See "System replaceable units" on page 131 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 1800 (No more hardware interrupt available for PCI adapter.) 1. Run the Configuration/Setup Utility program. 2. Remove adapter. 1801 (No more ROM space available for PCI adapter.) 1. Run the Configuration/Setup Utility program. 2. Remove adapter. 3. Disable the adapter BIOS and run the Configuration/Setup Utility program. 1802 (Unavailable I/O address for PCI adapter) 1. Start the Configuration/Setup Utility program and make sure that I/O addresses for all adapters are set correctly. 2. Adapter. 3. System board. 1803 (Unavailable memory address for PCI adapter) 1. Start the Configuration/Setup Utility program and make sure that memory addresses for all other adapters are set correctly. 2. Adapter. 3. System board. 1804 (Unavailable memory address for PCI adapter) 1. Remove an adapter to make memory address space available. 2. Disable adapter BIOS on adapter. 3. Adapter. 4. System board. 1805 (PCI ROM error occurred) 1. Remove all adapters and reinstall one at a time, restarting the server each time, until the failing adapter is determined; then, replace that adapter. 2. System board. 1806 (PCI-to-PCI bridge error occurred) 1. Remove all adapters and reinstall one at a time, restarting the server each time, until the failing adapter is determined; then, replace that adapter. 2. System board. 1807 (xxxxyyyy PCI device unresponsive or disabled by user, where xxxx=PCI vendor ID and yyyy=PCI device ID) 1. Run the Configuration/Setup Utility program and make sure the device is enabled. 2. Adapter. 3. System board. 1808 (Unsupported PCI device is installed) 1. Remove all adapters and reinstall one at a time, restarting the server each time, until the failing adapter is determined; then, replace that adapter. 2. System board. 1962 (Drive does not contain a valid boot sector) 1. Verify that a startable operating system is installed. 2. Run diagnostics. 3. Hard disk drive. 4. SCSI backplane. 5. Cable. 6. System board. 2400 (Video controller test failure) 1. Video adapter (if installed) 2. System board. 102 xSeries 226 Type 8488 and 8648: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200

Note:
See
“System
replaceable
units”
on
page
131
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
1800
(No
more
hardware
interrupt
available
for
PCI
adapter.)
1.
Run
the
Configuration/Setup
Utility
program.
2.
Remove
adapter.
1801
(No
more
ROM
space
available
for
PCI
adapter.)
1.
Run
the
Configuration/Setup
Utility
program.
2.
Remove
adapter.
3.
Disable
the
adapter
BIOS
and
run
the
Configuration/Setup
Utility
program.
1802
(Unavailable
I/O
address
for
PCI
adapter)
1.
Start
the
Configuration/Setup
Utility
program
and
make
sure
that
I/O
addresses
for
all
adapters
are
set
correctly.
2.
Adapter.
3.
System
board.
1803
(Unavailable
memory
address
for
PCI
adapter)
1.
Start
the
Configuration/Setup
Utility
program
and
make
sure
that
memory
addresses
for
all
other
adapters
are
set
correctly.
2.
Adapter.
3.
System
board.
1804
(Unavailable
memory
address
for
PCI
adapter)
1.
Remove
an
adapter
to
make
memory
address
space
available.
2.
Disable
adapter
BIOS
on
adapter.
3.
Adapter.
4.
System
board.
1805
(PCI
ROM
error
occurred)
1.
Remove
all
adapters
and
reinstall
one
at
a
time,
restarting
the
server
each
time,
until
the
failing
adapter
is
determined;
then,
replace
that
adapter.
2.
System
board.
1806
(PCI-to-PCI
bridge
error
occurred)
1.
Remove
all
adapters
and
reinstall
one
at
a
time,
restarting
the
server
each
time,
until
the
failing
adapter
is
determined;
then,
replace
that
adapter.
2.
System
board.
1807
(xxxxyyyy
PCI
device
unresponsive
or
disabled
by
user,
where
xxxx=PCI
vendor
ID
and
yyyy=PCI
device
ID)
1.
Run
the
Configuration/Setup
Utility
program
and
make
sure
the
device
is
enabled.
2.
Adapter.
3.
System
board.
1808
(Unsupported
PCI
device
is
installed)
1.
Remove
all
adapters
and
reinstall
one
at
a
time,
restarting
the
server
each
time,
until
the
failing
adapter
is
determined;
then,
replace
that
adapter.
2.
System
board.
1962
(Drive
does
not
contain
a
valid
boot
sector)
1.
Verify
that
a
startable
operating
system
is
installed.
2.
Run
diagnostics.
3.
Hard
disk
drive.
4.
SCSI
backplane.
5.
Cable.
6.
System
board.
2400
(Video
controller
test
failure)
1.
Video
adapter
(if
installed)
2.
System
board.
102
xSeries
226
Type
8488
and
8648:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide