Error code/symptom FRU/action 165-060-000 (Service Processor: RSA may be busy) 1. Rerun the diagnostic test. 2. Fix other error conditions that might be keeping the Remote Supervisor Adapter II busy. Refer to the error log and diagnostic panel. 3. Disconnect all server and option power cords from the server, wait 30 seconds, reconnect, and retry. 4. System board. . 165-198-000 (Service Processor: Aborted) 1. Rerun the diagnostic test. 2. Fix other error conditions that might be keeping the Remote Supervisor Adapter II busy. Refer to the error log and diagnostic panel. 3. Disconnect all server and option power cords from the server, wait 30 seconds, reconnect, and retry. 4. System board. 165-201-000 (Service Processor: Failed) 1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry. 2. System board. 165-330-000 (Service Processor: Failed) v Update to the latest ROM diagnostic level, and retry. 165-342-000 (Service Processor: Failed) 1. Make sure that the latest firmware levels for Remote Supervisor Adapter II and BIOS are installed. 2. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry. 3. System board. 166-198-000 System Management: Aborted 1. Run the diagnostic test again. (Unable to communicate with RSA. It may be busy. Run the test again.) 2. Correct other error conditions and retry. These include other failed system-management tests and items that are logged in the system-error log of the optional Remote Supervisor Adapter II. 3. Disconnect all server and option power cords from the server, wait 30 seconds, reconnect, and retry. 4. Remote Supervisor Adapter II. 5. System board. 166-201-001 System Management: Failed (I2C bus error(s). See SERVPROC and DIAGS entries in event log.) 1. Reseat the I2C cable between the Remote Supervisor Adapter II and the system board. 2. Reseat DIMMs. 3. DIMMs. 4. System board. 166-250-000 System Management: Failed (I2C cable is disconnected. Reconnect I2C cable between Remote Supervisor Adapter and system board.) 1. Reseat the I2C cable between the Remote Supervisor Adapter II and the system board. 2. Remote Supervisor Adapter II. 3. System board. 166-260-000 System Management: Failed (Restart RSAError. After restarting, RSA communication was lost.) 1. Disconnect all server and option power cords from the server, wait 30 seconds, reconnect, and retry. 2. Reseat the Remote Supervisor Adapter II. 3. Remote Supervisor Adapter II. 106 xSeries 226 Type 8488 and 8648: Hardware Maintenance Manual and Troubleshooting Guide