IBM 8837 User Manual

IBM 8837 - eServer xSeries 336 Manual

IBM 8837 manual content summary:

  • IBM 8837 | User Manual - Page 1
    • Memory xSeries 336 Type 8837 Installation Guide Welcome. . . Thank you for buying an IBM xSeries server. Your server is based IBM systems management software and IBM ServeRAID programs Go to the Web for instructions, http://www.ibm.com/pc/support System is ready to use. Go to the Server Support
  • IBM 8837 | User Manual - Page 2
    Yes solved? No Use the troubleshooting information provided with your server to determine the cause of the problem and the action to take. Register your computer. Go to http://www.ibm.com/pc/register/ View information about IBM support line at http://www.ibm.com/services/sl/products/ or view
  • IBM 8837 | User Manual - Page 3
    ERserver IBM xSeries 336 Type 8837 Installation Guide
  • IBM 8837 | User Manual - Page 4
    Note: Before using this information and the product it supports, read the general information in Appendix B, "IBM Statement of Limited Warranty Z125-4753-08 04/2004," on page 71, and Appendix C, Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
  • IBM 8837 | User Manual - Page 5
    Contents Safety v Chapter 1. Introduction 1 The IBM xSeries Documentation CD 2 Hardware and software requirements 2 Using the Documentation Browser 2 Notices and statements used in this document 3 Features and specifications 4 Major components of the
  • IBM 8837 | User Manual - Page 6
    you call 69 Using the documentation 69 Getting help and information from the World Wide Web 70 Software service and support 70 Hardware service and support 70 Appendix B. IBM Statement of Limited Warranty Z125-4753-08 04/2004 71 Part 1 - General Terms 71 Part 2 - Country-unique Terms
  • IBM 8837 | User Manual - Page 7
    , leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright IBM Corp. 2004 v
  • IBM 8837 | User Manual - Page 8
    book under statement 1. Be sure to read all caution and danger statements in this documentation before performing the instructions. Read any additional safety information that comes with the server or optional device before you install the device. vi IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 9
    damage. v Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures. v Connect and disconnect cables as described in the following table when installing, moving
  • IBM 8837 | User Manual - Page 10
    of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device. v Use of controls or adjustments or performance of procedures other instruments, and avoid direct exposure to the beam. viii IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 11
    Statement 4: ≥ 18 kg (39.7 lb.) ≥ 32 kg (70.5 lb.) CAUTION: Use safe practices when lifting. Statement 5: ≥ 55 kg (121.2 lb.) CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also
  • IBM 8837 | User Manual - Page 12
    this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. WARNING: Handling the cord riesgos reproductivos. Lávese las manos después de usar el producto. x IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 13
    instructions for installing some options. More detailed instructions for installing options are in the IBM xSeries 336 Type 8837 Option Installation Guide on the IBM documentation and technical updates: 1. Go to http://www.ibm.com/pc/support/. 2. In the Learn section, click Online publications.
  • IBM 8837 | User Manual - Page 14
    # For a list of supported options for the server, go to the ServerProven® Web site at http://www.ibm.com/pc/compat/. See the Rack Installation Instructions document for complete rack installation and removal instructions. The IBM xSeries Documentation CD The IBM xSeries Documentation CD contains
  • IBM 8837 | User Manual - Page 15
    in the multilingual Safety Information document, which is on the IBM xSeries Documentation CD. Each statement is numbered for reference to problem situations. v Attention: These notices indicate potential damage to programs, devices, or data. An attention notice is placed just before the instruction
  • IBM 8837 | User Manual - Page 16
    GHz or higher depending on server model v Support for up to two microprocessors with Intel Hyper- controllers with Wake on LAN® feature and Alert Standard Format support v Three Universal Serial Bus (USB) ports v One below which a large number of computers will operate. Power supply: v 585 watt
  • IBM 8837 | User Manual - Page 17
    can be hot-swapped, which means that if the server and operating system support hot-swap capability, you can remove or install the component while the server can also indicate touch points on hot-swap components.) See the instructions for removing or installing a specific hot-swap component for any
  • IBM 8837 | User Manual - Page 18
    6 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 19
    instructions are intended for users who are experienced with setting up IBM server hardware. If you need more detailed instructions, see the Option Installation Guide on the IBM Hot-swap means that if the server and operating system support hot-swap capability, you can remove or install the component
  • IBM 8837 | User Manual - Page 20
    inside the server with the power on The server supports hot-swap devices and is designed to operate safely removing the server cover. For detailed instructions, go to the Option Installation Guide. Complete the following steps to remove the server cover. 8 IBM xSeries 336 Type 8837: Installation
  • IBM 8837 | User Manual - Page 21
    MB, 512 MB, 1 GB, and 2 GB DIMMs. See the ServerProven list at http://www.ibm.com/pc/compat/ for a list of memory modules that the server supports. v The server comes with one pair of DIMMs installed in DIMM slots 1 and 2 on the system board. The server comes with a minimum of 512 MB
  • IBM 8837 | User Manual - Page 22
    : 3 and 4 3 Slot: 5 and 6 4 Slot: 7 and 8 v The server also supports memory sparing; however, the sparing feature is mutually exclusive with mirroring. The sparing feature disables the failed of DIMMs to replace the failed active DIMM pair. 10 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 23
    configuration has changed. This section provides an overview of the procedure for installing memory modules. For detailed instructions, see the Option Installation Guide. Complete the following steps to install a DIMM: 1. Read the safety information beginning on page v and "Installation guidelines
  • IBM 8837 | User Manual - Page 24
    Both SCSI configuration models of the server come with a hot-swap SCSI backplane. v The SCSI server models support low voltage differential (LVD) hot-swap drives. Each hot-swap drive is in a tray, which has v and "Installation guidelines" on page 7. 12 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 25
    disk drive This section provides an overview of the procedure for installing a 2.5-inch hot-swap hard disk drive. For detailed instructions, see the Option Installation Guide. Drive-tray assembly Drive handle Filler panel Complete the following steps to install a 2.5-inch hot-swap SCSI hard disk
  • IBM 8837 | User Manual - Page 26
    a microprocessor: v The server supports up to two microprocessors (two-way support); the IBM xSeries 336 server comes with one Xeon microprocessor installed. With two microprocessors, the server can operate as a symmetric multiprocessing (SMP) server. 14 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 27
    With SMP, application programs can distribute the processing load between the microprocessors. This enhances performance for database and point-of-sale applications, integrated manufacturing solutions, and other applications. v The following illustration shows the microprocessor sockets and the
  • IBM 8837 | User Manual - Page 28
    the ServerProven list at http://www.ibm.com/pc/compat/ for a list of microprocessors that the server supports. This section provides an overview of the procedure for installing an additional microprocessor. For detailed instructions, see the Option Installation Guide. Complete the following steps to
  • IBM 8837 | User Manual - Page 29
    Attention: v Do not use excessive force when pressing the microprocessor into the socket. v Center the microprocessor over the microprocessor socket. Align the triangle on the corner of the microprocessor with the triangle on the corner of the socket and carefully press the microprocessor into the
  • IBM 8837 | User Manual - Page 30
    the documentation that comes with the adapter and follow those instructions in addition to the instructions in this section. If you must change the switch setting or jumper settings on the adapter, follow the instructions that come with the adapter. 18 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 31
    1 - PCI-X or PCI-Express slot 2 This section provides an overview of the procedure for installing an adapter. For detailed instructions, see the Option Installation Guide. Complete the following steps to install an adapter: 1. Read the safety information beginning on page v and the "Installation
  • IBM 8837 | User Manual - Page 32
    riser card. 5. Snap the low-profile adapter into place on the low-profile adapter support. 6. Make sure that the retention latches for the low-profile riser card are still an adapter in slot 2. For detailed instructions, see the Option Installation Guide. 20 IBM xSeries 336 Type 8837: Installation
  • IBM 8837 | User Manual - Page 33
    Complete the following steps to install an adapter into slot 2: 1. Open the retaining clips on both sides of the slot 2 riser card. Note: Insert your finger into the access hole on the slot 2 adapter cover to open the retention latch at the rear of the server. The following illustration shows the
  • IBM 8837 | User Manual - Page 34
    between the upper and lower guides of the PCI-adapter retainer cables to the adapter. See the instructions that come with the adapter for details from the fans. See the Option Installation Guide for cable routing information. 10. If Guide for more information on routing cables in the server. 22
  • IBM 8837 | User Manual - Page 35
    on the server. Cover release latch Fan door Fan door 4. Close the fan doors. 5. Install the server in the rack. See the Rack Installation Instructions that come with the server for details. Notes: a. After cabling the server, you might need to run the Configuration/Setup Utility program to update
  • IBM 8837 | User Manual - Page 36
    , see the section about configuring the server in the User's Guide on the IBM xSeries Documentation CD. Some options have device drivers that you must system to support SMP. For more information, see the section about using the ServerGuide Setup and Installation CD in the User's Guide and the
  • IBM 8837 | User Manual - Page 37
    For information about configuring the integrated Gigabit Ethernet controller, see the Broadcom NetXtreme Gigabit Ethernet Software CD. Chapter 2. Installing options 25
  • IBM 8837 | User Manual - Page 38
    26 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 39
    drive v 3.5-inch SATA non-hot-swap (simple swap) hard disk drive Note: Both 3.5-inch configurations support an optional DVD-ROM drive. The following illustration shows the front view of an IBM xSeries 336 server with a 2.5-inch SCSI hot-swap hard disk drive configuration. Hard disk drive activity
  • IBM 8837 | User Manual - Page 40
    electrical outlet. v Power-control button: Press this button to turn the server on and off manually. A power-control-button shield comes with the server. You can install this disk-shaped shield to indicates that one of the hard disk drives is in use. 28 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 41
    the server if it is in a location with numerous other servers. You can use IBM Director to light this LED remotely. This LED is controlled by the BMC. v of the last failure but will not take immediate action to correct the problem. The remind function is handled by the BMC. v Reset button: Press
  • IBM 8837 | User Manual - Page 42
    lists the LEDs and the problems that they indicate. LED None OVER SPEC PS1 PS2 CPU VRM CNFG microprocessor and memory configuration Memory Nonmaskable interrupt Soft error Service processor Hard disk drive Fan (TEMP LED might PCI-E type adapter. 30 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 43
    operating system does not run, and all core logic except for the BMC is shut down; however, the server can respond to requests from the service processor, such as a remote request to turn on the server. The power-on LED flashes to indicate that the server is connected to ac power
  • IBM 8837 | User Manual - Page 44
    software can turn on the server. v If your operating system supports the Wake on LAN feature, the Wake on LAN feature can continue to run and the server can respond to requests from the service processor, such as a remote request to turn on the server. IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 45
    management controller can turn off the server as an automatic response to a critical system failure. v You can turn off the server through a request from the service processor. Chapter 3. Server controls, LEDs, connectors, and power 33
  • IBM 8837 | User Manual - Page 46
    34 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 47
    Guide on the IBM supported operating-system versions, see the label on the CD. Complete the following steps to start the ServerGuide Setup and Installation CD: 1. Insert the CD, and restart the server. If the CD does not start, see "ServerGuide problems" on page 58. 2. Follow the instructions
  • IBM 8837 | User Manual - Page 48
    to access the full Configuration/Setup Utility menu. 3. Follow the instructions on the screen. Configuring the Gigabit Ethernet controller The Ethernet about configuring the controllers, go to http://www.ibm.com/pc/support/. Using the baseboard management controller The baseboard management
  • IBM 8837 | User Manual - Page 49
    code to enable SOL: 1. Update the BIOS code: a. Download the latest version of the BIOS code from http://www.ibm.com/pc/support/. b. Update the BIOS code, following the instructions that come with the update file that you downloaded. 2. Configure the BIOS settings: a. Restart the server and press F1
  • IBM 8837 | User Manual - Page 50
    serial console. See the documentation for your specific Linux operating-system type for information and instructions. Use one of the following procedures to enable SOL sessions for your Linux operating system. of the first label=linux line: -Monitor 38 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 51
    f. Add the following line to the first image= section. This enables SOL. append="console=ttyS0,19200n8 console=tty1" g. Add the following lines between the two image= sections: # This will allow you to Interact with the OS boot via SOL image=/boot/vmlinuz-2.4.9-e.12smp label=linux-Interact initrd=/
  • IBM 8837 | User Manual - Page 52
    two title= sections: # This will allow you to Interact with the OS boot via SOL title Red Hat Linux (2.4.9-e.12smp) SOL Interactive root (hd0,0) 40 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 53
    kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 console=tty1 console=ttyS0,19200 initrd /initrd-2.4.9-e.12smp.img Note: The entry that begins with kernel /vmlinuz is shown with a line break after console=tty1. In your file, the entire entry must all be on one line. The following examples show the
  • IBM 8837 | User Manual - Page 54
    to log in as the root user through the SOL console: ttyS1 3. Complete the following steps to modify the /boot/grub/menu.lst file: 42 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 55
    a. Comment out the gfxmenu line by adding a # in front of the word gfxmenu. b. Add the following line before the first title line: # This will allow you to only Monitor the OS boot via SOL c. Append the following text to the first title line: SOL Monitor d. Append the following text to the kernel
  • IBM 8837 | User Manual - Page 56
    Options: line has /redirect appended to the end of it. The following examples show the original bootcfg program output and the output after modification. 44 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 57
    the following steps to install the OSA SMBridge management utility program on a server running a Windows operating system: 1. Go to http://www.ibm.com/pc/support/ and download the utility program and create the OSA BMC Management Utility CD. 2. Insert the OSA BMC Management Utility CD into the
  • IBM 8837 | User Manual - Page 58
    must be logged in as a root user to perform these procedures. 1. Go to http://www.ibm.com/pc/support/ and download the utility program and create the OSA BMC Management Utility CD. 2. Insert the OSA /sbin/smbconfig /usr/bin/smbconfig /usr/sbin/ipmish 46 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 59
    data only and does not affect any device drivers. Go to http://www.ibm.com/pc/support/ to download the utility program; then, copy the Flash.exe file to Web and you have obtained the applicable update package, follow the instructions that come with the update package. Using the OSA SMBridge
  • IBM 8837 | User Manual - Page 60
    Display system information that is related to the server and the globally unique identifier (GUID). Using the RAID configuration programs Use the LSI Logic setup utility program and associated devices - Monitor operation of your RAID controllers 48 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 61
    optional ServeRAID controller, you must use the IBM ServeRAID Support CD that comes with the controller. v of adapters; then, press Enter. 4. Follow the instructions on the screen to change the settings of the displayed. See the User's Guide on the IBM xSeries Documentation CD for more information
  • IBM 8837 | User Manual - Page 62
    devices. See the ServeRAID documentation on the IBM ServeRAID Support CD for additional information about RAID technology and instructions for using ServeRAID Manager to configure your remove the CD from the DVD-ROM drive. 7. Restart the server. 50 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 63
    the ServeRAID controller. For information about these programs, see the documentation that comes with the ServeRAID adapter and the User's Guide on the IBM xSeries Documentation CD. If the server comes with an operating system installed, such as Microsoft Windows 2000 Datacenter Server, see
  • IBM 8837 | User Manual - Page 64
    52 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 65
    drop-down list, follow the instructions on the Web page to download the latest version. 2. Install the IBM Director program. 3. Download and install any applicable updates or interim fixes for the server: a. Go to http://www.ibm.com. b. At the top of the page, click Support & downloads. c. Under the
  • IBM 8837 | User Manual - Page 66
    54 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 67
    you cannot locate and correct the problem using the information in this chapter, see Appendix A, "Getting help and technical assistance," on page 69, the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD, and the "Server Support" flowchart in the front of this
  • IBM 8837 | User Manual - Page 68
    Note: See the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD for more information about the POST beep codes. One beep of day clock failed Beep 3-2-1 Serial port failed Beep 3-2-2 Parallel port failed 56 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 69
    Troubleshooting Guide on the IBM xSeries Documentation CD for more information about the POST error messages. Table 6. Abbreviated list of POST error messages POST message Failing device or problem found Suggested action 161 The real-time clock battery Replace the battery or call for service
  • IBM 8837 | User Manual - Page 70
    installed; the option is not system is supported, either there is no logical drive defined (SCSI RAID systems) available. or the ServerGuide System Partition is not present. Run the ServerGuide program and make sure that setup is complete. 58 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 71
    Manual and Troubleshooting Guide on the IBM xSeries Documentation CD for more detailed troubleshooting charts. If you cannot find the problem in these charts, run the diagnostic programs. If you have run the diagnostic programs, or if running the tests does not reveal the problem, call for service
  • IBM 8837 | User Manual - Page 72
    and the monitor are turned on. v Try using another keyboard. If the problem remains, call for service. v Make sure that the mouse or pointing-device cable is securely connected to mouse or pointing device. If the problem remains, call for service. 60 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 73
    when it detected a problem, or a memory pair might have been manually disabled. Check the problem remains, call for service. Monitor problems Some IBM monitors have their own self-tests. If you suspect a problem with your monitor, see the information that comes with the monitor for instructions
  • IBM 8837 | User Manual - Page 74
    remains, call for service. Option problems Symptom An IBM option that was just installed does not work. Suggested action Make sure that: v The option is designed for the server. See the "Server Support" flowchart for information about obtaining ServerProven compatibility information from the
  • IBM 8837 | User Manual - Page 75
    might have installed more options than the power supply supports. If the problem remains, call for service. Determine whether you are using an Advanced Configuration for service. Serial port problems For more information about the serial port, see the Option Installation Guide on the IBM xSeries
  • IBM 8837 | User Manual - Page 76
    problem problem. If the problem remains, contact your place of purchase of the software. Universal Serial Bus device problems operating system supports USB devices. If the problem remains, call for service. Light Path board, which enables you to isolate a problem that causes the server to shut down.
  • IBM 8837 | User Manual - Page 77
    error. 5. Install the server cover; then, slide the server into the rack cabinet and connect all external cables. See the Rack Installation Instructions for information about how to install the server into rack cabinet. The following illustration shows the LEDs on the Light Path diagnostics panel
  • IBM 8837 | User Manual - Page 78
    in three locations on the server are available to help you diagnose problems that might occur either during or after installation. Use them in beside the defective microprocessor. 6. Follow the instructions in the Option Installation Guide on the IBM xSeries Documentation CD to remove and replace the
  • IBM 8837 | User Manual - Page 79
    LED None OVER SPEC PS 1 PS 2 CPU VRM CNFG MEM NMI S ERR SP DASD Note: When there is correctly. See the Option Installation Guide on the IBM xSeries Documentation CD for information about installing a microprocessor. If the problem remains, call for service. If a configuration error has occurred
  • IBM 8837 | User Manual - Page 80
    has occurred on PCI bus B An error has occurred on PCI bus C If the problem remains, call for service. v Check the LEDs on the system board to identify the component that is causing controllers or check for a general system board malfunction. 68 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 81
    tools is in the Hardware Maintenance Manual and Troubleshooting Guide on the IBM xSeries Documentation CD or in the IntelliStation Hardware Maintenance Manual at the IBM Support Web site. v Go to the IBM Support Web site at http://www.ibm.com/pc/support/ to check for technical information, hints
  • IBM 8837 | User Manual - Page 82
    /. You can find service information for your IBM products, including supported options, at http://www.ibm.com/pc/support/. Software service and support Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with xSeries servers
  • IBM 8837 | User Manual - Page 83
    . Many features, conversions, or upgrades involve the removal of parts and their return to IBM. A part that replaces a removed part will assume the warranty service status of the removed part. Unless IBM specifies otherwise, these warranties apply only in the country or region in which you purchased
  • IBM 8837 | User Manual - Page 84
    of purchase as evidence of your entitlement to warranty service. What IBM Will Do to Correct Problems When you contact IBM for service, you must follow the problem determination and resolution procedures that IBM specifies. An initial diagnosis of your problem can be made either by a technician over
  • IBM 8837 | User Manual - Page 85
    to fulfill its obligations under this Statement of Limited Warranty (which may include shipping the Machine for such processing to other IBM service locations around the world), and (c) ensure that such processing complies with any laws applicable to such Personal Data. Limitation of Liability
  • IBM 8837 | User Manual - Page 86
    IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. Governing Law Both you and IBM consent to the application of the laws of the country in which you acquired the Machine to govern by the Civil Courts of Justice of Santiago. 74 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 87
    Metropolitan Area Of the City of Caracas. NORTH AMERICA How to Obtain Warranty Service: The following is added to this Section: To obtain warranty service from IBM in Canada or the United States, call 1-800-IBM-SERV (426-7378). Appendix B. IBM Statement of Limited Warranty Z125-4753-08 04/2004 75
  • IBM 8837 | User Manual - Page 88
    injury (including death) or physical harm to real property and tangible personal property caused by IBM's negligence; and Governing Law: The following replaces "laws of the country in which you acquired as chairman of the proceedings. Vacancies in the 76 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 89
    death) or damage to real property and tangible personal property will be limited to that caused by IBM's negligence; and 2. as to any other actual damage arising in any situation involving nonperformance by IBM pursuant to, or in any way related to the subject of this Statement of Limited Warranty
  • IBM 8837 | User Manual - Page 90
    not apply in respect of any goods which IBM provides, if you require the goods for when local law requires otherwise). PHILIPPINES Limitation of Liability: Item 3 Manila, Philippines in accordance with the laws of the Philippines then by the president of the Philippine Dispute Resolution Center, Inc.
  • IBM 8837 | User Manual - Page 91
    any of those countries from either (1) an IBM reseller approved to perform warranty service or (2) from IBM, provided the Machine has been announced and made available by IBM in the country in which you wish to obtain service. If you purchased a Personal Computer Machine in Albania, Armenia, Belarus
  • IBM 8837 | User Manual - Page 92
    before, and settled exclusively by, the competent court of a) Athens for Greece, b) Tel Aviv-Jaffa for Israel, c) Milan for Italy, d) Lisbon for Portugal, and e) 80 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 93
    in all EU countries provided the Machines have been announced and made available in such countries. How to Obtain Warranty Service: The following is added to this section: To obtain warranty service from IBM in EU countries, see the telephone listing in Part 3 - Warranty Information. You may contact
  • IBM 8837 | User Manual - Page 94
    actually arising as an immediate and direct consequence of the non-fulfillment of such obligations (if IBM is at fault), for a maximum amount equal to the charges you paid for the Machine THE FOLLOWING TERMS APPLY TO THE COUNTRY SPECIFIED: AUSTRIA 82 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 95
    agreement for such Machine and get your money refunded. The second paragraph does not apply. What IBM Will Do to Correct Problems: The following is added to this section: During the warranty period, IBM will reimburse you for the transportation charges for the delivery of the failing Machine to
  • IBM 8837 | User Manual - Page 96
    IBM or your reseller is unable to repair an IBM IBM Will Do to Correct Problems : The following is added to this section: During the warranty period, transportation for delivery of the failing Machine to IBM will be at IBM IBM with fraud or gross IBM of Services Act IBM in connection with, or
  • IBM 8837 | User Manual - Page 97
    this Statement of Warranty will be limited to the charge paid by you for the individual Machine that is the subject of your claim from IBM. UNITED KINGDOM Limitation of Liability: The following replaces the terms of this section in its entirety: For the purposes of this section, a "Default" means
  • IBM 8837 | User Manual - Page 98
    parts and 1 year on labor means that IBM provides warranty service without charge for: 1. parts and labor IBM will charge you for any labor provided in performance of the repair or replacement(s) in the second and third year of the warranty period. 86 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 99
    for country and location specific information. 1. Customer Replaceable Unit ("CRU") Service IBM provides replacement CRUs to you for you to install. CRU information and replacement instructions are shipped with your Machine and are available from IBM at any time on your request. Installation of Tier
  • IBM 8837 | User Manual - Page 100
    service is called ThinkPad® EasyServ or EasyServ in some countries. The IBM Machine Warranty World Wide Web site at http://www.ibm.com/servers/support/machine_warranties/ provides a worldwide overview of IBM -4420 United Kingdom -- +44-1475-555-055 88 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 101
    right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not
  • IBM 8837 | User Manual - Page 102
    IBM IBM (logo) IntelliStation NetBAY Netfinity NetView OS/2 WARP Predictive Failure Analysis PS/2 ServeRAID ServerGuide ServerProven ThinkPad and other countries. Other company, product, or service names may be trademarks or service marks of others. Important notes Processor speeds indicate
  • IBM 8837 | User Manual - Page 103
    no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software may differ from its retail version (if available), and may not include user manuals or all program functionality. Product recycling and
  • IBM 8837 | User Manual - Page 104
    radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in ICES-003. Avis de conformité à la réglementation d'Industrie Canada 92 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 105
    responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product, including the fitting of non-IBM option cards. This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to
  • IBM 8837 | User Manual - Page 106
    power cords for a specific country or region are usually available only in that country or region. IBM power cord part number 02K0546 13F9940 Used in these countries and regions China Australia, Fiji, Kiribati, Nauru, New Zealand, Papua New Guinea 94 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 107
    IBM power cord part number 13F9979 13F9997 14F0015 14F0033 14F0051 14F0069 14F0087 Jamaica, Japan, Mexico, Micronesia (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Taiwan, United States of America, Venezuela Korea (Democratic People's Republic of), Korea (Republic
  • IBM 8837 | User Manual - Page 108
    IBM power cord part number 6952300 Used in these countries and regions Antigua and Barbuda, (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Thailand, Taiwan, United States of America, Venezuela 96 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 109
    hard disk drive configurations 12 installation 12 installing a hot-swap (SCSI) 13 Installing a simple swap 14 problems 60 heat output 4 help, getting 70 humidity 4 I IBM Director 53 important notices 3 Information LED 29 installing cover 22 integrated baseboard management controller utility programs
  • IBM 8837 | User Manual - Page 110
    power-control-button shield 28 power-on LED 31 problems 63 requirement 4 supply 4 98 IBM xSeries 336 Type 8837: Installation Guide problems DVD-ROM drive 59 expansion enclosure 59 general 50 ServerGuide CD 1 error symptoms 58 Setup and Installation CD 35 service and support hardware 70 software 70
  • IBM 8837 | User Manual - Page 111
    States FCC Class A notice 92 Universal Serial Bus (USB) problems 64 updating the firmware code 47 USB connector 28, 31 using baseboard management controller utility programs 47 V video connector 31 W Wake on LAN feature web site, IBM support weight, server 4 4, 32, 33 1, 7, 9, 16, 53, 69, 70
  • IBM 8837 | User Manual - Page 112
    100 IBM xSeries 336 Type 8837: Installation Guide
  • IBM 8837 | User Manual - Page 113
  • IBM 8837 | User Manual - Page 114
    Part Number: 25R4613 Printed in USA (1P) P/N: 25R4613
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Welcome. . .
Thank you for buying an
IBM xSeries server.
This server
contains information for setting
up and configuring your server.
For detailed information about
your server, view the publications
on the
You can also find the most
current information about your
server on the IBM Web site at:
Your server
is based on the X-Architecture
technology, and it features
superior performance, availability,
and scalability.
Documentation CD.
Installation Guide
Go to the Server Support
flow chart
Cable the server
and options
Start the server
Install options:
• Drives
• Microprocessors
• Adapters
• Memory
Did the server
start correctly?
Yes
No
Use ServerGuide™
to set up and
configure hardware
Did configuration
complete?
Use
ServerGuide to
install operating
system?
Install applications,
such as IBM systems
management software
and IBM ServeRAID
programs
System is ready to use.
Go to the Server Support
flow chart to register
and profile your server.
Go to the Web for instructions,
No
Yes
Yes
No
Installation Guide
Install the server in
the rack, if required
xSeries 336
Type 8837