Icom IC-7100 Instruction Manual - Page 51

Squelch and receive (RF) sensitivity, Adjusting RF gain, Adjusting squelch - lighting control

Page 51 highlights

3 BASIC OPERATION Squelch and receive (RF) sensitivity Adjusts the RF gain and squelch threshold level. The squelch removes noise output to the speaker when no signal is received (closed squelch). • T he squelch is particularly effective for AM and FM, but also works in other modes. • T he 12 to 1 o'clock position is recommended for the most effective use of the [RF/SQL] (L) control. • T he [RF/SQL] (L) control operates as only an RF gain control (Squelch is fixed open), or a squelch control (RF gain is fixed at maximum sensitivity) depending on the "RF/ SQL Control" option in the "Function" Set mode. (p. 6-5) SET > Function > RF/SQL Control The L, R, C or D in the instructions indicate the part of the controller. L: Left side, R: Right side, C: Center bottom D: Display (Touch screen) [RF/SQL] SET MODE OPERATING SETTING MODE [RF/SQL] OPERATION AUTO Operates as only a squelch A M / F M / W F M / control. DV • R F gain is fixed at maxi- mum sensitivity. Operates as only an RF SSB/CW/RTTY gain control. • Squelch is fixed open. SQL ALL Operates as only a squelch control. • R F gain is fixed at maxi- mum sensitivity. RF+SQL (default) FM/DV Operates as an RF gain control, and a noise squelch or S-meter squelch. SSB/CW/RTTY/ AM Operates as an RF gain control, and an S-meter squelch. • When used as an RF gain/squelch control Squelch is open. Noise squelch (FM/DV modes) Recommended level Maximum RF gain RF gain adjustable range S-meter squelch • When used as an RF gain control (Squelch is fixed open; SSB, CW, RTTY only) ❍ Adjusting RF gain (Receive sensitivity) Normally, [RF/SQL] (L) is set to the 12 o'clock position. Rotate [RF/SQL] (L) to the 11 o'clock position for maximum sensitivity. • Rotating counterclockwise from the maximum position re- duces sensitivity. • The S-meter indicates receive sensitivity. While rotating the RF gain control, a faint noise may be heard. This comes from the DSP unit and does not indicate an equipment malfunction. ❍ Adjusting squelch (Removing non-signal noise) Rotate [RF/SQL] (L) clockwise when no signal is received, until the noise just disappears. • The TX/RX LED light goes out. • Rotating [RF/SQL] (L) past the threshold point activates the S-meter squelch- this allows you to set a minimum signal level needed to open the squelch. Adjustable range Minimum RF gain Maximum RF gain • When used as a squelch control (RF gain is fixed at maximum.) Noise squelch (FM/DV modes) Noise squelch threshold (FM/DV modes) S-meter squelch threshold Squelch is open. S-meter squelch Shallow Deep 3-19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

3
BASIC OPERATION
3-19
Squelch and receive (RF) sensitivity
Adjusts the RF gain and squelch threshold level. The
squelch removes noise output to the speaker when no
signal is received (closed squelch).
• The squelch is particularly effective for AM and FM, but also
works in other modes.
• The 12 to 1 o’clock position is recommended for the most
effective use of the [RF/SQL]
(
L
) control.
• The [RF/SQL]
(
L
) control operates as only an RF gain
control (Squelch is fixed open), or a squelch control (RF
gain is fixed at maximum sensitivity) depending on the
“RF/
SQL Control” option in
the “Function” Set mode. (p. 6-5)
SET
> Function >
RF/SQL Control
SET MODE
SETTING
OPERATING
MODE
[RF/SQL]
OPERATION
AUTO
AM/FM/WFM/
DV
Operates as only a squelch
control.
• RF gain is fixed at maxi
-
mum sensitivity.
SSB/CW/RTTY
Operates as only an RF
gain control.
• Squelch is fixed open.
SQL
ALL
Operates as only a squelch
control.
• RF gain is fixed at maxi
-
mum sensitivity.
RF+SQL
(default)
FM/DV
Operates as an RF gain
control, and a noise squelch
or S-meter squelch.
SSB/CW/RTTY/
AM
Operates as an RF gain
control, and an S-meter
squelch.
Adjusting RF gain
(Receive sensitivity)
Normally, [RF/SQL]
(
L
) is set to the 12 o’clock posi-
tion.
Rotate [RF/SQL]
(
L
) to the 11 o’clock position for
maximum sensitivity.
• Rotating counterclockwise from the maximum position re
-
duces sensitivity.
• The S-meter indicates receive sensitivity.
While rotating the RF gain control, a faint noise may
be heard. This comes from the DSP unit and does
not indicate an equipment malfunction.
Adjusting squelch
(Removing non-signal noise)
Rotate [RF/SQL]
(
L
) clockwise when no signal is re-
ceived, until the noise just disappears.
• The TX/RX LED light goes out.
• Rotating [RF/SQL]
(
L
)
past the threshold point activates
the S-meter squelch— this allows you to set a minimum sig-
nal level needed to open the squelch.
[RF/SQL]
• When used as an RF gain/squelch control
• When used as an RF gain control
(Squelch is fixed open; SSB, CW, RTTY only)
• When used as a squelch control
(RF gain is fixed at maximum.)
Maximum
RF gain
S-meter
squelch
Noise squelch (FM/DV modes)
Squelch is
open.
RF gain
adjustable
range
Recommended level
Minimum RF gain
Adjustable
range
Maximum
RF gain
Squelch is
open.
S-meter
squelch
S-meter squelch
threshold
Noise squelch
threshold
(FM/DV modes)
Shallow
Deep
Noise squelch (FM/DV modes)
The
L
,
R
,
C
or
D
in the instructions indicate the
part of the controller.
L
: Left side,
R
: Right side,
C
: Center bottom
D