Previous view 12 SCAN OPERATION Scan edge programming Memory channels 1A-3A and 1B-3B are the Program Scan Edge channels. They are used to program the upper and lower frequency edges for programmed scans. (See Section 11) Factory default frequency and operating modes are programmed into the Scan Edge channels: 1A/1B are for HF, 2A/2B are for the 144 MHz, and 3A/3B are for the 430 MHz frequency bands, and you can reprogram it as desired. If both upper and lower band edges are programmed with the same frequency, a programmed scan cannot start. EXAMPLE: Programming 14.000.00 MHz into 2A and 14.360.00 MHz into 2B. qqTouch the Memory channel number indication once or twice to select the VFO mode. (p. 3-4) wwRotate [M-CH] (L) to select scan edge 2A. eeSet 14.000.00 MHz as the lower frequency. rrPush MENU (C) one or more times to select the "M- 1" (Menu 1) screen. ttTouch [MW](D) for 1 second to program 14.000.00 MHz into scan edge 2A. • T hree beeps sound when the programming is complete. yyRotate [M-CH] (L) to select scan edge 2B. uuSet 14.360.00 MHz as the upper frequency. iiTouch [MW] for 1 second to program 14.360.00 MHz into scan edge 2B. • T hree beeps sound when the programming is complete. Left Display Center Right The L, R, C or D in the instructions indicate the part of the controller. L: Left side R: Right side C: Center bottom D: Display (Touch screen) [M-CH] MENU Touch [MW] for 1 second Programming 14.000.00 MHz/USB into 2A. Programming 14.360.00 MHz/USB into 2B. 12-7