    INSTRUCTION MANUAL VHF MOBILE TRANSCEIVERS iF5020 Series UHF MOBILE TRANSCEIVERS iF6020 Series
  • Icom IC-F6021 | Instruction Manual - Page 2
    trouble-free operation. IMPORTANT READ ALL INSTRUCTIONS carefully and completely before using the transceiver. SAVE THIS INSTRUCTION MANUAL - This instruction manual contains important oper­ating instructions for the IC-F5021, IC-F5023, IC-F5023H, IC-F5026, ICF5026H, IC approved by Icom Inc., could
  • Icom IC-F6021 | Instruction Manual - Page 3
    could cause a fire or damage the transceiver. RWARNING! NEVER cut the DC power cable between the DC plug and fuse holder. If an incorrect connection is made after and may damage the transceiver. Icom is not responsible for the destruction or damage to the Icom transceiver, if the malfunction is
  • Icom IC-F6021 | Instruction Manual - Page 4
    TABLE OF CONTENTS IMPORTANT i EXPLICIT DEFINITIONS i FCC INFORMATION i PRECAUTIONS ii 1 PANEL DESCRIPTION 1 ■ Front panel 1 ■ Function display 2 ■ Programmable function keys 3 2 BASIC OPERATION 7 ■ Turning ON the transceiver 7 ■ Channel selection 7 ■ Call procedure 8 ■ Receiving and
  • Icom IC-F6021 | Instruction Manual - Page 5
    Scan is cancelled when it is off hook. r DEALER-PROGRAMMABLE KEYS - Scan is paused when it is off hook. Desired functions can be programmed independently by - A utomatic priority channel can be selected when it is off hook. your dealer. (p. 3) - Sets to 'Inaudible' condition (mute condition
  • Icom IC-F6021 | Instruction Manual - Page 6
    scrambler function is activated. u BELL INDICATOR Displayed/blinks when the specific 2/5-Tone/MDC* code is received, according to the pre-programming. i SCAN INDICATOR Blinks during scan. o ALPHANUMERIC DISPLAY Displays an operating channel number, channel name, Set mode contents, DTMF code
  • Icom IC-F6021 | Instruction Manual - Page 7
    ], [P1], [P2] and [P3] programmable function keys. ➥ Push to start and cancel scanning operation. 3 Consult your Icom dealer or system operator for details concerning your transceivers programming. • When Power ON Scan function is activated, push to pause the scanning operation. And the paused
  • Icom IC-F6021 | Instruction Manual - Page 8
    : The un-mute condition ('Audible' condition) may automatically return to the mute condition ('Inaudible' condition) after a specified period depending on programming. LOCK KEY Hold down to electronically lock all programmable keys except the following: [Moni(Audi)], [Lock], [Call] (incl. Call A and
  • Icom IC-F6021 | Instruction Manual - Page 9
    wide, mid* and narrow. • T he wide passband width can be selected from 20.0 or 25.0 kHz using the CS-F3020/F5010/F5020 cloning software. (PMR operation only) Ask your dealer for details. *D epending on the presetting, the mid width cannot be selected. Ask your dealer for details. EMERGENCY
  • Icom IC-F6021 | Instruction Manual - Page 10
    selected with external input operation. • This function can be used when the external unit, such as a dimmer control connected to the transceiver with an optional cable, OPC1939. (p. 14) • Ask your dealer for details of external input operation. 6
  • Icom IC-F6021 | Instruction Manual - Page 11
    transceiver ■ Channel selection 1 2 q Push [ ] to turn ON the transceiver. Several types of channels can be selected. Methods may w If the transceiver is programmed for a start up password, differ depending on your system set up. 3 input the digit codes as directed by your dealer. • The
  • Icom IC-F6021 | Instruction Manual - Page 12
    to a comfortable listening level. q S elect the desired TX code channel, 2/5-Tone code according to your System Operator's instructions. • This may not be necessary depending on programming. • Refer to pages 9-10 for selection. w P ush [Call] (assigned to one of the dealer programmable keys
  • Icom IC-F6021 | Instruction Manual - Page 13
    is displayed. w P ush [CH Up] or [CH Down] to select the desired TX code 7 • Time-out timer channel. 8 A fter continuous transmission for the pre-programmed period of time, the time-out timer is activated, causing the e After selecting, push [TX Code CH Select] to set. • Return to the stand
  • Icom IC-F6021 | Instruction Manual - Page 14
    2 BASIC OPERATION D TX code number edit (PMR operation only) If the transceiver has [TX Code CH Select] or [TX Code Enter] assigned to it, TX code contents can be edited within the allowable digits. USING [TX CODE CH SELECT] KEY: q P ush [TX Code CH Select] to enter the TX code channel selection
  • Icom IC-F6021 | Instruction Manual - Page 15
    BASIC OPERATION 2 ■ User Set mode ■ Scrambler function 2 If the transceiver has [User Set Mode] assigned to it, you The voice scrambler function provides private communication can "customize" the transceiver operation to suit your between stations. preferences and operating style. The
  • Icom IC-F6021 | Instruction Manual - Page 16
    2 BASIC OPERATION ■ Stun function When the specified ID, set as a stun ID or kill ID, is received, the stun function is activated. When the stun ID is received, the transceiver becomes unusable. Entering of the password (p. 7) or receiving a specified ID, set as a revive ID, is necessary to operate
  • Icom IC-F6021 | Instruction Manual - Page 17
    transceivers on the system. send an Emergency MDC 1200 system command once An additional feature of MDC 1200 system found in Icom or repeatedly for a programmed number of times until it 5 transceivers is called aliasing. Each transceiver on the system has a unique ID number. Aliasing allows the
  • Icom IC-F6021 | Instruction Manual - Page 18
    . (Depending on version, the fuse holder may not be attached to the black cable.) Red t Black 12V Battery 14 NOTE: Use the terminals as shown below for the cable connections. Crimp Solder r r OPTIONAL CABLE (OPC-1939) Connect an external modem, dimmer control, and so on. t DC POWER RECEPTACLE
  • Icom IC-F6021 | Instruction Manual - Page 19
    Microphone hanger Microphone and screw set hanger cable DC power cable Function name stickers* Mounting bracket Flat washers Mount the transceiver securely with the 4 supplied screws to a thick surface which can support more than 1.5 kg 4 (3.3 lb). 5 6 Flat washer 7 8 9 10
  • Icom IC-F6021 | Instruction Manual - Page 20
    to connect to an external terminal. A fuse is installed in each fuse holder of the supplied DC power cable*. If a fuse blows or the transceiver stops functioning, track down the source of the problem if possible, and then replace the damaged fuse with a new rated one. *Depending on version, only
  • Icom IC-F6021 | Instruction Manual - Page 21
    A6730-1EX-5 Printed in Japan © 2009-2019 Icom Inc. Apr. 2019 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan