    Limited functions only OPERATING GUIDE OPERATING GUIDE FOR IC-F5120D/F6120D SERIES MDC 1200 SYSTEM/ IDAS™ OPERATION Limited functions only
  • Icom IC-F6121D | Operating Guide - Page 2
    GUIDE - This operating guide contains important oper­ating instructions for: • IC-F5121D, IC-F5122D, IC-F5123D and IC-F5128D VHF MOBILE TRANSCEIVERS • IC-F6121D, IC-F6122D, IC-F6123D and IC #6,912,495 B2. Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in
  • Icom IC-F6121D | Operating Guide - Page 3
    TABLE OF CONTENTS IMPORTANT i VOICE CODING TECHNOLOGY i TABLE OF CONTENTS ii 1 PREPARATION 1 ■ Programmable function keys 1 2 MDC 1200 OPERATION 2-3 ■ MDC 1200 system operation 2 ■ Receiving a call 2 ■ Transmitting a call 3 3 IDAS OPERATION 4-16 ■ IDAS operation 4 ■ IDAS Trunk operation
  • Icom IC-F6121D | Operating Guide - Page 4
    [P0], [P1], [P2] and [P3] programmable function keys. Consult your Icom dealer or system operator for details concerning your transceivers preprogramming. D For only push to cancel the automatic scroll and manually scroll the message. ➥ When an SDM that contains more than 8 characters is displayed,
  • Icom IC-F6121D | Operating Guide - Page 5
    . • The calling station ID (or alias) and "EMG EMG" are alternately 4 displayed. 5 An additional feature of the MDC 1200 system in Icom trans- ceivers is called aliasing. Each transceiver on the system has 6 a unique ID number. Aliasing allows substituting an alphanu- 7 meric name for the
  • Icom IC-F6121D | Operating Guide - Page 6
    .) D Transmitting an Emergency Call When [Emergency] (described in the instruction manual) is held down for a specified time period,* the emergency signal period again before transmitting the call. If your transceiver is programmed for Silent operation, you can transmit emergency calls without the
  • Icom IC-F6121D | Operating Guide - Page 7
    3 IDAS OPERATION ■ IDAS operation ■ Receiving a call 1 The IC-F5120D and IC-F6120D series use the Icom Digital D Receiving a Voice Call 2 Advanced System (IDAS) that meets the 6.25 kHz emission q When a Voice call is received: 3 mask requirements for narrow banding. IDAS increases
  • Icom IC-F6121D | Operating Guide - Page 8
    3 IDAS OPERATION ■ Receiving a call (continued) D Receiving a Call Alert q When a Call Alert signal is received: • Beeps sound. • " " blinks. • The calling station or Talkgroup ID name (or code) and "CALLALRT" alternately appear. Blinks D Receiving a Status Message q When a Status Message is
  • Icom IC-F6121D | Operating Guide - Page 9
    : • The transceiver cannot be operated until data cloning is per- 10 the message automatically scrolls. • Push [Status Up] or [Status Down] to manually scroll the mes- sage. formed. Ask your dealer for details. 11 NOTE: Depending on the preprogramming, the transceiver 12 can ignore the Stun
  • Icom IC-F6121D | Operating Guide - Page 10
    3 IDAS OPERATION ■ Receiving a call (continued) D Receiving a Remote Monitor, Radio Check or Status Polling Call If an Individual call with a Remote monitor, Radio Check or Status polling command is received, the transceiver will automatically transmit. (RAN code matching may not be necessary,
  • Icom IC-F6121D | Operating Guide - Page 11
    IDAS OPERATION 3 D Displaying the received call log 1 If activated, the log stores received calls into the transceiver's memory. e P ush [Digital Button] again to display the call log information. 2 Up to 10 calls can be stored, and the oldest call record is When log information is displayed
  • Icom IC-F6121D | Operating Guide - Page 12
    3 IDAS OPERATION ■ Receiving a call (continued) D Talk Back function The talk back function allows you to select the same call mode (Analog or Digital) and/or call type (Individual or Talkgroup) as the received call. When the talk back timer is set to 0 seconds, this function is not activated. Ask
  • Icom IC-F6121D | Operating Guide - Page 13
    match their Individual or Talkgroup ID and/or RAN (Radio Access Number) code. • The preprogrammed ID name is displayed. • When an ID name is not programmed, ID code is displayed. 4 • The primary ID can be preset to display first. • When you want to make a voice call to all transceivers within
  • Icom IC-F6121D | Operating Guide - Page 14
    [Digital Button] again to enter the Individual or Talk- group ID selection mode. • The preprogrammed ID name is displayed. • When an ID name is not programmed, the ID code is displayed. • The primary ID can be preset to display first. r P ush [CH Up] or [CH Down] to select the desired ID
  • Icom IC-F6121D | Operating Guide - Page 15
    mode. 2 There are up to 100 status messages that can be sent. • The preprogrammed ID name is displayed. 3 • When an ID name is not programmed, the ID code is displayed. q P ush [Digital Button] to enter the application selection • The primary ID can be preset to display first. 4 mode
  • Icom IC-F6121D | Operating Guide - Page 16
    t P ush [Digital Button] again to enter the Individual or Talkgroup ID selection mode. • The preprogrammed ID name is displayed. • When an ID name is not programmed, the ID code is displayed. • The primarily ID can be preset to display first. y P ush [CH Up] or [CH Down] to select the desired ID
  • Icom IC-F6121D | Operating Guide - Page 17
    an Emergency Call When [Emergency] (described in the instruction manual) is held down for the specified time period, the display, depending on the preprogramming. (Silent operation) The transceiver can also be programmed to keep the microphone open during an emergency call, allowing other stations to
  • Icom IC-F6121D | Operating Guide - Page 18
    has being received. This function is convenient when the operator is away from the transceiver. Ask your dealer or system operator, or refer to the IC-F5120D/ F6120D series service manual for connection and setting details. 15
  • Icom IC-F6121D | Operating Guide - Page 19
    ■ Connecting a Printer When the printer is connected to the transceiver through the OPC-2078, the received SDM content and the called station ID can be printed out. Ask your dealer or system operator for connection details. ■ Using Voice Encryption The encryption function enables voice encrypting,
  • Icom IC-F6121D | Operating Guide - Page 20
    A6903-2EX-0b © 2011-2018 Icom Inc. 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan