Intel R2000LH2/LT2 Service Guide

Intel R2000LH2/LT2 Manual

Intel R2000LH2/LT2 manual content summary:

  • Intel R2000LH2/LT2 | Service Guide - Page 1
    Intel® Server System R2000LH2/LT2 Family Service Guide A Guide for Technically Qualified Assemblers of Intel® identified Subassemblies/Products Order Number: G42282-004
  • Intel R2000LH2/LT2 | Service Guide - Page 2
    trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2012 Intel Corporation. All Rights Reserved. ii Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 3
    ® Server Deployment Toolkit 3.0 CD y/o en http://www.intel.com/support/motherboards/server/sb/cs-010770.htm. http://www.intel.com/support/motherboards/server/sb/cs-010770.htm 上的 Intel® Server Boards and Server Chassis Safety Information(《Intel Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 4
    contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. iv Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 5
    board/chassis, a list of accessories or other components you may need, troubleshooting information, and instructions on how to add and replace components on the Intel® Server System R2000LH2/LT2 family products. For the latest revision of this manual, go to http://www.intel.com/p/en_US/support
  • Intel R2000LH2/LT2 | Service Guide - Page 6
    Regulatory document Use this Document or Software Intel® Server System R2000LH2/LT2 Family Technical Product Specification See the section on the web page titled, "Architecture/Specifications". Intel® Server System R2000LH2/LT2 Family Quick Installation User's Guide See the section on the web page
  • Intel R2000LH2/LT2 | Service Guide - Page 7
    Drive Bay and Front Panel Options 4 Front Panel ...5 Back Panel ...5 Server Board Components...6 System Recovery Jumpers...8 Peripheral Devices...9 2 Hardware Installations and Upgrades 13 PCI Add-in Card ...24 Removing a PCI Add-in Card...25 Intel® Server System R2000LH2/LT2 Service Guide vii
  • Intel R2000LH2/LT2 | Service Guide - Page 8
    Intel® RAID Smart Battery 45 Installing the Intel® RAID Smart Battery 45 Removing the Intel® RAID Smart Battery 46 Installing and Removing the Server Board 46 Removing the Server Board...47 Installing the Server Board into Rack (Optional 57 viii Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 9
    for Intel® Chassis Subassembly Products 73 Extent of Limited Warranty...73 Warranty Limitations and Exclusions 73 Limitations of Liability...74 How to Obtain Warranty Service ...74 Telephone Support...74 Returning a Defective Product...74 Intel® Server System R2000LH2/LT2 Service Guide ix
  • Intel R2000LH2/LT2 | Service Guide - Page 10
    15 Figure 17. System Fan Order ...16 Figure 18. Connecting the Fan Power Cables to the Fan Board and PDB 16 Figure 19. Removing the Front Bezel ...17 Figure 20. Installing the Front Bezel ...17 Locking Lever 31 Figure 47. Installing Memory ...32 x Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 11
    68. Installing the Intel® RAID Smart Battery 45 Figure 69. Removing the Intel® RAID Smart Battery 46 Figure 70. Removing the Server Board ...47 Figure 71. Installing the Server Board ...47 Figure Figure 87. Remove Inner Member from Chassis 60 Intel® Server System R2000LH2/LT2 Service Guide xi
  • Intel R2000LH2/LT2 | Service Guide - Page 12
    Tables Table 1. Intel® Server System R2000LH2/LT2 family product list v Table 2. Server System References...vi Table 3. Intel® Server System R2000LH2/ Disk Drive Options ...9 Table 7. BIOS Setup: Keyboard Command Bar 61 Table 8. Screen Map ...63 xii Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 13
    . Table 3. Intel® Server System R2000LH2/LT2 Feature Summary Server System Intel® Server System R2000LH2 product family Integrated Server Board Intel® Server Board S4600LH2 Intel® Server System R2000LT2 product family Intel® Server Board S4600LT2 Feature Dimensions Processor Support Memory
  • Intel R2000LH2/LT2 | Service Guide - Page 14
    AXXELVRAIL)  Premium rack mount rail kit (AXXPRAIL), will be available at post launch CAUTION: THE MAXIMUM RECOMMENDED SERVER WEIGHT FOR THE RACK RAILS CAN BE FOUND at http://www.intel.com/support/motherboards/server/sb/CS-033655.htm. EXCEEDING THE MAXIMUM RECOMMENDED WEIGHT OR MISALIGNMENT OF THE
  • Intel R2000LH2/LT2 | Service Guide - Page 15
    Server System Features Wattage Limitation of the PCI Loading Table 4 summarizes the wattage limitation of the PCI loading. Table 4. Power Supply 260W 450W VIN 100~127VAC (AC low-Line) 200~240VAC (AC high-line) Total Available Power 1120W 1600W Intel® Server System R2000LH2/LT2 Service Guide 3
  • Intel R2000LH2/LT2 | Service Guide - Page 16
    you can also use the Quick Reference Label provided on the inside of the chassis cover to assist in identifying components. Figure 2. Intel® Server System R2000LH2/LT2 Components Hot Swap Hard Drive Bay and Front Panel Options Figure 3. 3.5" Hot Swap Hard Drive Bay - 4 Drive Configuration Figure
  • Intel R2000LH2/LT2 | Service Guide - Page 17
    Front Panel Server System Features Label A B C D  E Description System ID Button w/Integrated LED Label Description F System Status LED NMI Supply Module #1 Add-in adapter slots from Riser Card Figure 6. Back Panel Feature Identification Intel® Server System R2000LH2/LT2 Service Guide 5
  • Intel R2000LH2/LT2 | Service Guide - Page 18
    Components This section helps you identify the components and connectors on the server board. Description A Manufacturing Mode jumper B Serial 'A' Port (RJ45) C NIC 2 D NIC 1 E (Option Power Slot #1 AR CPU #3 DIMM slots - Memory Banks J and K 6 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 19
    jumper BI Serial A jumper AC BIOS Default jumper BJ BMC force update AD ME Force Update jumper AE CPU #1 DIMM slots - Memory Banks C and D AF CPU #1 socket AG CPLD programming header Figure 7. Server Board Connector and Component Locations Intel® Server System R2000LH2/LT2 Service Guide 7
  • Intel R2000LH2/LT2 | Service Guide - Page 20
    , the system can only boot from EFI-bootable recovery media with the recovery BIOS image. The main system BIOS will not boot. These pins should be selected on 1-2 for normal system 1-2 for normal system operation. Figure 8. Configuration Jumpers 8 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 21
    to run at a maximum ambient temperature of 45°C. Note: The Intel® Server System R2000LH2/LT2 does not support all SAS or Serial ATA (SATA) hard drives. For a web link to a list of supported hard drives, see Additional Information and Software. Intel® Server System R2000LH2/LT2 Service Guide 9
  • Intel R2000LH2/LT2 | Service Guide - Page 22
    board and the system drives. The following diagrams show the location for each connector found on the backplane. 4 x 3.5" Hard Drive Backplane A SAS/SATA Hot-swap Connectors Figure 11. 4 x 3.5-inch Hard Drive Backplane Components (Front View) 10 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 23
    Server System Features A Power Connector B SGPIO Connector C I2C Connector D SATA Connectors Figure 12. 4 x 3.5-inch Hard Drive Connectors B Mini-SAS Connectors C I2C Connector Figure 14. 8 x 2.5-inch Hard Drive Backplane Components (Rear View) Intel® Server System R2000LH2/LT2 Service Guide 11
  • Intel R2000LH2/LT2 | Service Guide - Page 24
    and USB Media Redirection allowing USB devices attached to the remote system to be used on the managed server. For instructions on installing the Intel® Remote Management Module 4, see Installing and Removing the Intel® Remote Management Module 4. 12 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 25
    To activate the port SCU1 (4-7) on the server board, a proper Intel® RAID C600 Upgrade Key must be installed. For instructions, see Intel® RAID C600 Upgrade Key Installation Guide. 2. A second SSD is supported when the optical drive is NOT in use. Intel® Server System R2000LH2/LT2 Service Guide 13
  • Intel R2000LH2/LT2 | Service Guide - Page 26
    Hardware Installations and Upgrades Figure 15. Cable Routing - 4 x 3.5" Hot Swap HDD 14 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 27
    board, a proper Intel® RAID C600 Upgrade Key must be installed. For instructions, see Intel® RAID C600 Upgrade Key Installation Guide. 2. A second SSD is supported when the optical drive is NOT in use. Figure 16. Cable Routing - 8 x 2.5" Hot Swap HDD Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 28
    Hardware Installations and Upgrades Fan Connections Use the figures below to determine the proper fan connections. Figure 17. System Fan Order Figure 18. Connecting the Fan Power Cables to the Fan Board and PDB 16 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 29
    A). 2. Rotate the front bezel clockwise till the left end clicks into place (see letter B). 3. Lock the bezel if needed. Figure 20. Installing the Front Bezel Intel® Server System R2000LH2/LT2 Service Guide 17
  • Intel R2000LH2/LT2 | Service Guide - Page 30
    bezel to the chassis with the two screws on left and right end as shown (see letter B). Figure 22. Installing the Front Fan Bezel 18 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 31
    23. Removing the Rack Handle Installing the Rack Handles Align the rack handle with the two holes on the side of the server system and attach the rack handle to the server system with two screws as shown. Figure 24. Installing the Rack Handle Intel® Server System R2000LH2/LT2 Service Guide 19
  • Intel R2000LH2/LT2 | Service Guide - Page 32
    system cover in place to ensure proper cooling. You will need to remove the top cover to add or replace components inside of the server. Before removing the top cover, power down the server and unplug all peripheral devices and the power cable(s). 20 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 33
    at the beginning of this book. 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the power cord. 4. Remove the screws (see letter A). 5. Depress (see letter B). Figure 28. Installing the System Cover Intel® Server System R2000LH2/LT2 Service Guide 21
  • Intel R2000LH2/LT2 | Service Guide - Page 34
    the system. 2. Remove the rack handles. For instructions, see Removing the Rack Handles. 3. Remove the system cover. For instructions, see Removing the System Cover. Removing the Front Connect any required cables, please refer to Cable Routing. 22 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 35
    disconnected from the system. 2. Remove the system cover. For instructions, see Removing the System Cover. Removing the PCI Riser Assembly board edge above the connector to ensure the connector is seated. Figure 32. Installing the PCI Riser Assembly Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 36
    the system. 2. Remove the system cover. For instructions, see Removing the System Cover. 3. Remove the PCI riser assemblies. For instructions, see Removing the PCI Riser Assembly. Installing a Figure 33. Installing a Half-Length PCI Add-In Card 24 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 37
    (see letter B). Figure 35. Removing a Half-Length PCI Add-In Card Note: Make sure that all empty add-in card slots have filler panels installed. Intel® Server System R2000LH2/LT2 Service Guide 25
  • Intel R2000LH2/LT2 | Service Guide - Page 38
    cover. For instructions, see Removing the System Cover. 3. Remove the PCI riser assemblies. For instructions, see Removing the PCI Riser Assembly. 4. Remove the power supply modules. For instructions, see Removing the Power Supply Module(s). 26 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 39
    air duct (see letter A). 2. Install air duct into the chassis (see letter B). 3. Flip down the power supply (see letter C). Figure 38. Installing the Air Duct Intel® Server System R2000LH2/LT2 Service Guide 27
  • Intel R2000LH2/LT2 | Service Guide - Page 40
    Remove the air duct. For instructions, see Removing the Air Duct. Removing Processor Heatsink(s) The heatsink is attached to the server board/processor socket with captive fasteners. tightened in a diagonal manner using the following procedure: 28 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 41
    doing the following:  Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate . 2. Remove the system cover. For instructions, see Removing the System Cover. Intel® Server System R2000LH2/LT2 Service Guide 29
  • Intel R2000LH2/LT2 | Service Guide - Page 42
    Assembly. 5. Remove the air duct. For instructions, see Removing the Air Duct. 6. Remove the processor heatsink(s). For instructions, see Removing Processor Heatsink(s). Installing the Processor gold key at corner of processor (see letter C). 30 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 43
    the power supply modules. For instructions, see Removing the Power Supply Module(s). 4. Remove the PCI riser assemblies. For instructions, see Removing the PCI Riser Assembly. 5. Remove the air duct. For instructions, see Removing the Air Duct. Intel® Server System R2000LH2/LT2 Service Guide 31
  • Intel R2000LH2/LT2 | Service Guide - Page 44
    you do not install all drives, empty drive bays must be occupied by carriers with plastic drive blank provided to maintain proper system cooling. 32 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 45
    bracket (see letter d1). Install the HDD interface bracket from top. Secure the bracket with three screws as shown (see letter d2). Slide the 2.5" HDD Intel® Server System R2000LH2/LT2 Service Guide 33
  • Intel R2000LH2/LT2 | Service Guide - Page 46
    the chassis (see letter E). Push in the lever to lock it into place (see letter F). Figure 52. Installing Hard Disk Drive - Inserting 3.5" HDD Assembly 34 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 47
    screws as shown. Make Sure the connector end of the drive matches the backplane connector (see letter E). Figure 55. Installing Hard Disk Drive - Installing 2.5" HDD Intel® Server System R2000LH2/LT2 Service Guide 35
  • Intel R2000LH2/LT2 | Service Guide - Page 48
    For instructions, see Removing the System Cover. Installing a Slimline Optical Drive 1. Install the plastic guide onto the back of the drive and attach with two screws as shown (see letter A). Figure 57. Installing the Plastic Guide to the Optical Drive 36 Intel® Server System R2000LH2/LT2 Service
  • Intel R2000LH2/LT2 | Service Guide - Page 49
    installing or removing the Intel® I/O expansion module, please make sure following steps are performed. 1. Ensure the AC power cord(s) are disconnected from the system. 2. Remove the system cover. For instructions, see Removing the System Cover. Intel® Server System R2000LH2/LT2 Service Guide 37
  • Intel R2000LH2/LT2 | Service Guide - Page 50
    Remove the air duct. For instructions, see Removing the Air Duct. Before Installing Intel® I/O Expansion Module at the Left Edge of the Board (Optional) 1. Install the converter (see letter C). Figure 60. Installing Intel® I/O Expansion Module 38 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 51
    front of the module into the back panel slot (see letter B). 3. Attach the module to the server board connector (see letter C). 4. Secure the module with the two screws as shown (see letter D). Figure 61. Installing Intel® I/O Expansion Module Intel® Server System R2000LH2/LT2 Service Guide 39
  • Intel R2000LH2/LT2 | Service Guide - Page 52
    the module out of the server system (see letter B and C). 3. Install the I/O expansion module filler panel into the system back panel and secure it to the chassis with the screw (see letter D). Figure 62. Removing Intel® I/O Expansion Module 40 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 53
    Lite Locate the RMM4 Lite connector next to onboard NIC port, carefully pick up the Intel® RMM4 Lite module, and match the alignment pin of the module and the connector on server board. Press to install. Figure 63. Installing the Intel® RMM4 Lite Intel® Server System R2000LH2/LT2 Service Guide 41
  • Intel R2000LH2/LT2 | Service Guide - Page 54
    NIC 1. Remove the cable to the module (see letter A). 2. Remove the two screws as shown and remove the module out of the server system (see letter B). 3. Remove the cable to the server board (see letter C). Figure 65. Removing the Intel® RMM4 NIC 42 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 55
    the system. 2. Remove the system cover. For instructions, see Removing the System Cover. 3. Remove the rack handles. For instructions, see Removing the Rack Handles. 4. Slide the E). 6. Connect cables (see letter F). Figure 66. Installing a SSD Intel® Server System R2000LH2/LT2 Service Guide 43
  • Intel R2000LH2/LT2 | Service Guide - Page 56
    up to remove from the carrier (see letter E). 6. Secure the Solid State Drive carrier to chassis with the two screws. Figure 67. Removing a SSD 44 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 57
    instructions, see Removing the System Cover. Installing the Intel® RAID Smart Battery 1. Connect the cable between the BBU and the RAID card. For details, see Intel® RAID Smart Battery User's Guide 68. Installing the Intel® RAID Smart Battery Intel® Server System R2000LH2/LT2 Service Guide 45
  • Intel R2000LH2/LT2 | Service Guide - Page 58
    . 9. Remove all the Intel® I/O expansion module(s). For instructions, see Removing Intel® I/O Expansion Module. 10. Remove Intel® Remote Management Module 4. For instructions, see Installing and Removing the Intel® Remote Management Module 4. 46 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 59
    Board Installing the Server Board 1. Place the server board into the server system (see letter A). 2. Secure the server board with thirteen screws (see letter B). Figure 71. Installing the Server Board 3. Connect all power cables to the server board. Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 60
    board. 7. Gently press the metal clip as shown to release the battery (see letter A). 8. Remove the battery from the plastic socket (see letter B). Figure 72. Replacing the Backup Battery 9. Dispose of the battery according to local ordinance. 48 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 61
    . For instructions, see Removing the System Cover. 2. Pull system fan straight up to remove it from the fan holder. 3. Replace the system fan by guiding it into the slot and firmly pressing down to ensure that it is properly seated. Figure 73. Replacing a system fan Intel® Server System R2000LH2
  • Intel R2000LH2/LT2 | Service Guide - Page 62
    system cover. For instructions, see Removing server system guides (see letter B). 3. Secure the backplane with the screw as shown (see letter C). Figure 75. Installing the backplane 4. Connect cables to backplane, please refer to Cable Routing. 50 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 63
    Front End Module. Removing the Lower Fan Board 1. Disconnect all cables from the lower fan board. 2. Remove the screws (see letter A). 3. Remove the lower fan board from the server chassis (see letter B). Figure 76. Removing the Lower Fan Board Intel® Server System R2000LH2/LT2 Service Guide 51
  • Intel R2000LH2/LT2 | Service Guide - Page 64
    the power supply modules. For instructions, see Removing the Power Supply Module(s). 4. Remove the PCI riser assemblies. For instructions, see Removing the PCI Riser Assembly. 5. Remove the air duct. For instructions, see Removing the Air Duct. 52 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 65
    server board (see letter A). 2. Remove the two screws as shown (see letter B). 3. Slide the module out (see letter C). 4. Remove the two screws as shown, slide the front USB header out (see letter D). Figure 78. Removing the front video and USB Module Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 66
    to the server board as shown instructions, see Removing the Power Supply Module(s). 4. Remove the PCI riser assemblies. For instructions, see Removing the PCI Riser Assembly. 5. Remove the air duct. For instructions, see Removing the Air Duct. 54 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 67
    the LCP Module 1. Remove the front video and USB module. For instructions, see Removing the Front Video and USB Module. 2. Secure the Install the LCP and USB cables to the server board as shown (see letter D). Figure 80. Installing the LCP Module Intel® Server System R2000LH2/LT2 Service Guide 55
  • Intel R2000LH2/LT2 | Service Guide - Page 68
    out (see letter C). 4. Remove the two screws as shown, slide the front USB header out (see letter D). 5. Install the front video and USB module. For instructions, see Installing the Front Video and USB Module. Figure 81. Removing the LCP Module 56 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 69
    Optional) Caution: The maximum recommended server weight for the rack rails can be found at http://www.intel.com/support/motherboards/server/sb/CS-033655.htm. Exceeding Inner Member Safety Locking Pin Release Button Figure 82. Slides Component Intel® Server System R2000LH2/LT2 Service Guide 57
  • Intel R2000LH2/LT2 | Service Guide - Page 70
    to Rack 4. Align inner member key holes to standoffs on chassis, move inner member as shown below. Figure 84. Install Inner Member to Chassis 58 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 71
    slides until it is in the locked position, pull the release button to release lock and disconnect inner member from slides. Figure 86. Extend Slides Intel® Server System R2000LH2/LT2 Service Guide 59
  • Intel R2000LH2/LT2 | Service Guide - Page 72
    Hardware Installations and Upgrades 2. Press safety locking pin to release inner member from chassis. Figure 87. Remove Inner Member from Chassis 60 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 73
    settings. If "Yes" is selected and the key is pressed, the setup is exited and the BIOS returns to the main System Options Menu screen. The up arrow is used to select the previous value in a effect if a sub-menu or pick list is displayed. Intel® Server System R2000LH2/LT2 Service Guide 61
  • Intel R2000LH2/LT2 | Service Guide - Page 74
    .  The text shown in the Option Values and Help Text entries in each Field Description are the actual text and values are displayed on the BIOS Setup screens. 62 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 75
    provides additional information where it may be helpful. This information does not appear on the BIOS Setup screens.  Information enclosed in angular brackets (< >) in the screen shots Configuration Realtime Temperature and Voltage Status Intel® Server System R2000LH2/LT2 Service Guide 63
  • Intel R2000LH2/LT2 | Service Guide - Page 76
    Utilities Categories (Top Tabs) Server Management Screen (Tab With BMC Only] Boot Options Screen (Tab Boot Manager Screen (Tab) Error Manager Screen (Tab) Add EFI Boot Option Delete EFI Boot Option View Event Log Screen 3rd Level Screens 64 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 77
    A: Regulatory and Compliance Information Please refer to the Server Products Regulatory and Safety document for the product regulatory compliance reference. The document can be downloaded from http://www.intel.com/support/motherboards/server/. Intel® Server System R2000LH2/LT2 Service Guide 65
  • Intel R2000LH2/LT2 | Service Guide - Page 78
    Appendix B: Safety Information Appendix B: Safety Information Please refer to the Server Products Regulatory and Safety document for the Safety Information. The document can be downloaded from http://www.intel.com/support/motherboards/server/. 66 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 79
    Installation/Assembly Safety Instructions Please refer to the Server Products Regulatory and Safety document for the Installation/Assembly Safety Instructions. The document can be downloaded from http://www.intel.com/support/motherboards/server/. Intel® Server System R2000LH2/LT2 Service Guide 67
  • Intel R2000LH2/LT2 | Service Guide - Page 80
    ® Server Management. Note: You must login in to the reseller site to obtain the 24x7 number. Warranty Information To obtain warranty information, visit the following Intel® website: http://www.intel.com/support/motherboards/server/sb/cs-010807.htm 68 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 81
    Information: Customer Support Case#: Intel® Server Board or System: (Example: S2400BB, R2000BB) Server Chassis: (Example P4000M. If third-party chassis used, indicate make and model.) Base Board Information: (Some information maybe found by accessing BIOS & going through the Server Management menu
  • Intel R2000LH2/LT2 | Service Guide - Page 82
    /Use Manufacturer Model Firmware Storage Devices (Example: SCSI, SATA, SAS, USB, Tape, and so on): Manufacturer Model Type Size Firmware In Hot Swap Bay? 70 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 83
    (disks & RAID level): RAID volume use (Boot device/Data Volume): Is BBU (Battery Backup Unit) installed? (Yes/No): BBU part number: Detailed description of issue: Intel® Server System R2000LH2/LT2 Service Guide 71
  • Intel R2000LH2/LT2 | Service Guide - Page 84
    Appendix E: Intel® Server Issue Report Form Troubleshooting tried: Steps to replicate the issue: Issue impact statements: Do you have any potential Intel system, or component purchases that this and names are property of their respective owners. 72 Intel® Server System R2000LH2/LT2 Service Guide
  • Intel R2000LH2/LT2 | Service Guide - Page 85
    and fitness for a particular purpose. Intel® makes no expressed warranties beyond those stated here. Intel® disclaims all other warranties, expressed or implied including, without limitation, implied warranties of merchantability and fitness for a Intel® Server System R2000LH2/LT2 Service Guide 73
  • Intel R2000LH2/LT2 | Service Guide - Page 86
    for the product, please go to the following website to obtain instructions: http://www.intel.com/support/motherboards/warrantysupport.htm  In Europe and in Asia: Contact your original authorized distributor for warranty service. Any replacement Product is warranted under this written warranty and
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

Intel
®
Server System R2000LH2/LT2
Family Service Guide
A Guide for Technically Qualified Assemblers of Intel
®
identified Subassemblies/Products
Order Number: G42282-004