Intel S1200BT Specification update

Intel S1200BT Manual

Intel S1200BT manual content summary:

  • Intel S1200BT | Specification update - Page 1
    Server Board S1200BTS Intel® Server System R1304BTLSFAN Intel® Server System R1304BTSSFAN Intel® Server System R1304BTLSHBN Intel® Server System P4304BTLSFCN Intel® Server System P4304BTSSFCN Intel® Server System P4304BTLSHCN Intel Order Number G31821-008 July, 2012 Enterprise Platforms and Services
  • Intel S1200BT | Specification update - Page 2
    Specification Update Enterprise Platforms and Services Marketing Revision History Date April 2011 May 2011 June 2011 July 2011 Sep. 2011 Oct. 2011 Nov.2011 Dec.2011 April. 2012 May. 2012 June. 2012 July. 2012 Modifications Initial release. Updated Errata 1-4. Add Errata 16-19; Updated Errata
  • Intel S1200BT | Specification update - Page 3
    Update Enterprise Platforms and Services Marketing Disclaimers The Intel® products specified may contain design defects or errors known as errata that may cause the products to deviate from the published specifications. Current characterized errata are documented in this Specification Update
  • Intel S1200BT | Specification update - Page 4
    enabled in BIOS Setup ...9 20. When using Hardware RAID controller, pressing "Ctrl+G" can not enter RAID configuration utility...9 21. The RPM of three fans on Intel® Server System R1304BTLSHBN may drop to 0 sometimes after AC cycle ...9 22. PCT reports "Processor Does Not Support Brand ID
  • Intel S1200BT | Specification update - Page 5
    2. The AXXVRAIL is not included in the Intel® Server System R1304BTLSFAN, R1304BTLSHBN, and R1304BTSSFAN 13 3. Add Expected Post Code diagnostics LEDs status after system booting into the operating system ...14 4. Add BIOS new feature "Power on Password" and "Show CPU Core Ratio 14 v
  • Intel S1200BT | Specification update - Page 6
    Monthly Specification Update Enterprise Platforms and Services Marketing vi
  • Intel S1200BT | Specification update - Page 7
    Update Enterprise Platforms and Services Marketing Preface This document communicates product Errata and Documentation Changes and Corrections for the following Intel® Server Products:  Intel® Server Board S1200BTL/S1200BTS  Intel® Server System R1304BTLSFAN/R1304BTSSFAN/R1304BTLSHBN  Intel
  • Intel S1200BT | Specification update - Page 8
    when enabled TXT in BIOS 20 Fixed When using Hardware RAID controller, pressing "Ctrl+G" can not enter RAID configuration utility 21 Fixed The RPM of three fans on Intel® Server System R1304BTLSHBN drops to 0 sometimes after AC cycle 22 Fixed PCT reports "Processor Does Not Support Brand ID" 23
  • Intel S1200BT | Specification update - Page 9
    AXXVRAIL is not included in the Intel® Server System R1304BTLSFAN, R1304BTLSHBN, and R1304BTSSFAN package. Add Expected Post Code diagnostics LEDs status after system booting into operating system Add BIOS new feature "Power on Password" and "Show CPU Core Ratio" The following sections provide in
  • Intel S1200BT | Specification update - Page 10
    Specification Update Enterprise Platforms and Services Marketing Errata 1. Bios setting is locked after running 'syscfg/bldfs' to load Bios default setting Problem The user uses "syscfg/bldfs" to load BIOS default setting, the BIOS setting is locked. Implication The user can't change the BIOS
  • Intel S1200BT | Specification update - Page 11
    a driver for Intel® 82579 network cards. Status The issue is under investigation. Workaround N/A. 6. Node Manager does not work with Intel® Core™ Processor i3-2100 series or Intel® Pentium® Processor Problem On Intel® Server Board S1200BTL, node manager is supported with Intel® Xeon® Processor
  • Intel S1200BT | Specification update - Page 12
    33. Workaround N/A. 9. Windows 2008* R2 can't be installed properly or the OS will reset with NIC ROM disabled in BIOS Problem On Intel® Server Board S1200BTL and S1200BTS, the installation of Windows 2008* R2 will hang up or the system will reset after entering into OS if NIC ROM is disabled in
  • Intel S1200BT | Specification update - Page 13
    Monthly Specification Update Enterprise Platforms and Services Marketing 11. When EuLOT 6 is enabled, the system can't boot up by pressing the power button one time Problem When the user enables EuLOT6 in BIOS Setup, the system can't be powered up by pressing the power button one time.
  • Intel S1200BT | Specification update - Page 14
    Monthly Specification Update Enterprise Platforms and Services Marketing Workaround To use SOL, the user needs to enable the console redirection in BIOS. 15. The 4th HDD cage interferes with the right side rack handle screws on the Intel® Server System R1304BTLSHBN Problem The screws used to
  • Intel S1200BT | Specification update - Page 15
    . Status This issue has been fixed in BIOS Rev.28. After updating to BIOS Rev.28, the user needs to load BIOS default setting. Workaround None 21. The RPM of three fans on Intel® Server System R1304BTLSHBN may drop to 0 sometimes after AC cycle Problem After AC power off and power on, the
  • Intel S1200BT | Specification update - Page 16
    Update Enterprise Platforms and Services Marketing Problem Implication Status Workaround When running PCT(platform confidence test utility) on Intel® Server Board S1200BTL, PCT reports "Processor Does Not Support Brand ID". This is actually not an error message, it indicates that this Processor
  • Intel S1200BT | Specification update - Page 17
    Utility doesn't impact normal usage under operating system environment. 28. There is no driver for Intel® 82579 network card on VMWare ESXi* 5.0, VMWare ESXi* 4.1 Update 1 and VMWare* ESX 4.1 Update 1 Problem There is no driver for Intel® 82579 network card on VMWare ESXi* 5.0, VMWare
  • Intel S1200BT | Specification update - Page 18
    Monthly Specification Update Enterprise Platforms and Services Marketing Implication Status Workaround The boot up time is too long. Fixed in BIOS Rev. 35. None. 30. Unable to get Server Management variables on BTP using SysCfg Problem Implication Server Management Settings cannot be
  • Intel S1200BT | Specification update - Page 19
    2.0. Workaround N/A. 2. The AXXVRAIL is not included in the Intel® Server System R1304BTLSFAN, R1304BTLSHBN, and R1304BTSSFAN Problem The information in Intel® Server System R1304BTLSFAN, R1304BTLSHBN, and R1304BTSSFAN Technical Product Specification 1.0 indidcates the AXXVRAIL is included in
  • Intel S1200BT | Specification update - Page 20
    Update Workaround N/A. Enterprise Platforms and Services Marketing 3. Add Expected Post Code diagnostics LEDs status after system booting into the operating system Problem In Intel® Server Board S1200BT Technical Specification 1.0, there is no information for the Post Code after system
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Monthly Specification Update
Intel
®
Server Board S1200BTL
Intel
®
Server Board S1200BTS
Intel
®
Server System R1304BTLSFAN
Intel
®
Server System R1304BTSSFAN
Intel
®
Server System R1304BTLSHBN
Intel
®
Server System P4304BTLSFCN
Intel
®
Server System P4304BTSSFCN
Intel
®
Server System P4304BTLSHCN
Intel Order Number G31821-008
July, 2012
Enterprise Platforms and Services Marketing