    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Revision 2.4 May 2012 Enterprise Platforms and Services Division
  • Intel S1200BT | User Guide - Page 2
    attaching. Added EMI bracket cover information. Multiple corrections to the documentation. Updated half width SKU information Added S2400EP board and system Updated EPSD Platforms Based on Intel® Xeon® Processor E54600/2600/2400/1600/1400 Product Families System Debug Log section. ii Revision 2.4
  • Intel S1200BT | User Guide - Page 3
    for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice. Intel® server boards contain a number of high-density VLSI and power
  • Intel S1200BT | User Guide - Page 4
    RMM4 27 4.1 Configuring your Server Management NIC using BIOS setup on S1200BTL........28 4.2 Configuring your Server Management NIC using BIOS setup on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families 30 4.3 Configuring your Server Management NIC
  • Intel S1200BT | User Guide - Page 5
    Page 67 7.1.5 CPU Information Page on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families 68 7.2 Server Health Tab 69 7.2.1 Sensor Readings Page 69 7.2.2 Event Log Page...71 7.2.3 Power Statistics Page 72 7.3 Configuration Tab 73 7.3.1 Network
  • Intel S1200BT | User Guide - Page 6
    7.3.13 Node Manager Power Polices Page on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families 95 7.4 Remote Control tab 98 7.4.1 Console Redirection Page 98 7.4.2 Server Power Control Page 99 7.4.3 Virtual Front Panel Page on EPSD Platforms Based
  • Intel S1200BT | User Guide - Page 7
    Processor E5-4600/2600/2400/1600/1400 Product Families 31 Figure 21: IDA Configure Server: Communication Options Window 32 Figure 22: IDA Configure Server: Communication Options Window No Dedicated Server Management NIC installed 33 Figure 23: IDA Configure Server: Configure LAN Channel 3 (Intel
  • Intel S1200BT | User Guide - Page 8
    Guide Figure 24: IDA Configure Server: Configure LAN Channel 3 (Intel® RMM4 DMN) Static IP Address window ...35 Figure 25: IDA Configure Server: Set Up Users window 36 Figure 26: IDA Configure Server Platforms Based on Intel® Xeon® Processor E5- 4600/2600/2400/1600/1400 Product Families 61 Figure
  • Intel S1200BT | User Guide - Page 9
    Page on S1200BTL platforms 71 Figure 62: Server Health Event Log Page on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families 72 Figure 63: Server Health Power Statistics Page 72 Figure 64: Configuration Network Settings Page on S1200BTL platforms 73 Figure
  • Intel S1200BT | User Guide - Page 10
    EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families 95 Figure 85: Configuration Node Manager Page with Use Poilicy Suspend Period selected ........97 Figure 86: Remote Control Console Redirection Page 98 Figure 87: Remote Control Server Power Control Page on
  • Intel S1200BT | User Guide - Page 11
    Module 4 and Integrated BMC Web Console User Guide List of Tables List of Tables Table 1: Terminology ...1 Table 2: Intel® Server Boards RMM4 Lite Connector Locations 11 Table 3: Intel® Rack Server Systems - Chassis mounted Intel® Dedicated Server Management NIC Connector Locations...12 Table
  • Intel S1200BT | User Guide - Page 12
    List of Tables Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide xii Revision 2.4
  • Intel S1200BT | User Guide - Page 13
    Definition Address Resolution Protocol Baseboard Management Controller Dynamic Host Configuration Protocol Domain Name System Internet Control Message Protocol Intel® Advanced Server Management Interface Intel® Remote Management Module 4 Intelligent Platform Management Interface Keyboard, Video
  • Intel S1200BT | User Guide - Page 14
    Intel® RMM4 server product - whether you are using this guide or any other resource as a reference - pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide inside the jumper, causing intermittent problems with the function controlled by that jumper
  • Intel S1200BT | User Guide - Page 15
    BMC Web Console User Guide Introduction Safety Cautions Read all caution and safety statements in this document before performing any of the instructions. See also Intel® Server Boards and Server Chassis Safety Information at http://www.intel.com/support/motherboards/server/sb/cs-010770.htm
  • Intel S1200BT | User Guide - Page 16
    Introduction Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Der Mikroprozessor und instruction. Consultez Intel® Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http://www.intel.com/support/motherboards/server
  • Intel S1200BT | User Guide - Page 17
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Introduction INSTRUCCIONES DE SEGURIDAD: Cuando extraiga la tapa del chasis para acceder al interior del sistema, siga las siguientes instrucciones: 1. Apague todos los dispositivos perifé
  • Intel S1200BT | User Guide - Page 18
    technical support information on all Intel Enterprise Server and Storage Platforms. Information available at the support site includes:  Latest BIOS, firmware, drivers and utilities.  Product documentation, installation and Quick Start Guides.  Full product specifications, technical advisories
  • Intel S1200BT | User Guide - Page 19
    NIC RMM4 is comprised of up to two boards - Intel® RMM4 Lite and the optional Intel® Dedicated Server Management NIC (DMN). The Intel® RMM4 Lite is a small board that unlocks advanced management features on the RGMII interface when installed on Intel® server boards. It provides an increased level of
  • Intel S1200BT | User Guide - Page 20
    User Guide Figure 2: Intel® Dedicated Server Management NIC 2.2 Intel® RMM4 Features The Intel® RMM4 configuration in pre-boot POST and BIOS setup. 2.3 Supported Operating Systems and Internet Browsers The Intel® RMM4 enabled features run independent of the host operating system on the server
  • Intel S1200BT | User Guide - Page 21
    ® Remote Management Module 4 and Integrated BMC Web Console User Guide Intel® Remote Management Module 4 Overview 2.3.1 Server System The following operating systems are supported on the managed server:  Windows Server 2008* R2 SP1  Windows Server 2008* SP2  Red Hat* Enterprise Linux 6.2  SUSE
  • Intel S1200BT | User Guide - Page 22
    carrier board to provide a Dedicated RMM4 NIC port and a connector supporting the Intel® I/O modules  Associated mounting hardware (screws, standoff, and brackets) The installation will vary between the chassis configurations. The following sections provide installation instructions. 10 Revision
  • Intel S1200BT | User Guide - Page 23
    see your specific Intel® Server Systems Technical Product Specification and Intel® Server Systems Service Guide Table 2: Intel® Server Boards RMM4 Lite Connector Locations Intel® Server Board RMM4 Lite Connector Reference Designator S1200BTL S2400BB S2400EP S2400GP S2400LP S2400SC S2600CO
  • Intel S1200BT | User Guide - Page 24
    are steps that should be used when installing the Dedicated Server Management NIC module on those server systems. Note: For the next steps see your specific Intel® Server Systems Technical Product Specification and Intel® Server Systems Service Guide for more details. Table 3 lists the section and
  • Intel S1200BT | User Guide - Page 25
    ® Remote Management Module 4 and Integrated BMC Web Console User Guide Hardware Installations and Initial Configuration 3.3.2.1 Installing Dedicated NIC on Intel® Server System R1000BTL Family, R2000IP Family, or R2000SC Family 1. Ensure that AC power has been removed from the system and that
  • Intel S1200BT | User Guide - Page 26
    Hardware Installations and Initial Configuration Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Figure 5: Attaching the cable to Intel® Dedicated Server Management NIC module 5. Attach the cable to the cable connector on the Intel® Dedicated Server Management NIC module.
  • Intel S1200BT | User Guide - Page 27
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Hardware Installations and Initial Configuration Figure 6: Adding the Intel® Dedicated Server Management NIC module in the Intel® Server System R1000BTL Family and R2000SC Family Revision 2.4 15
  • Intel S1200BT | User Guide - Page 28
    Hardware Installations and Initial Configuration Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Figure 7: Adding the Intel® Dedicated Server Management NIC module in the Intel® Server System R2000IP Family 16 Revision 2.4
  • Intel S1200BT | User Guide - Page 29
    Web Console User Guide Hardware Installations and Initial Configuration 3.3.2.2 Installing Dedicated NIC on Intel® Server System R1000BB Intel® Serve system board and secure to the standoffs with two screws. Figure 8: Adding the Intel® Dedicated Server Management NIC module in the Intel® Server
  • Intel S1200BT | User Guide - Page 30
    Hardware Installations and Initial Configuration Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 3.3.2.4 Installing Dedicated NIC on Intel® Server System R1000EP Family 1. Ensure that AC power has been removed from the system and that you have waited at least 30
  • Intel S1200BT | User Guide - Page 31
    on the rIOM carrier modules. See your specific Intel® Server System Technical Product Specification (TPS) and Server Guides for details. These Intel® Half Width Systems are listed in Table 4. Table 4: Intel® Half Width Server Systems Intel® Server System H2000JF H2000LP H2000WP 3.3.5 Installation of
  • Intel S1200BT | User Guide - Page 32
    Hardware Installations and Initial Configuration Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Note: For the next two steps see your specific Intel® Server Systems Technical Product Specification and Intel® Server Systems Service Guide for more details. If appropriate,
  • Intel S1200BT | User Guide - Page 33
    BMC Web Console User Guide Hardware Installations and Initial Configuration Figure 11: Adding the Intel® Dedicated Server Management NIC module in an Intel® Server System P4000BTL Family Figure 12: Adding the Intel® Dedicated Server Management NIC module in an Intel® Server System P4000CP Family
  • Intel S1200BT | User Guide - Page 34
    Hardware Installations and Initial Configuration Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Figure 13: Adding the Intel® Dedicated Server Management NIC module in an Intel® Server System G4000CR Family or G4000IP Family 5. Add the EMI Bracket cover using the 2
  • Intel S1200BT | User Guide - Page 35
    User Guide Hardware Installations and Initial Configuration Figure 14. Installation of P4000S and P4000M chassis EMI Bracket Cover Figure 15. Installation of P4000L chassis EMI Bracket Cover 6. Replace the chassis cover, attach AC power and connect a network cable to the Intel® Dedicated Server
  • Intel S1200BT | User Guide - Page 36
    and Initial Configuration Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 3.3.6 Installation of the Intel® Dedicated Server Management NIC on a Third Party Pedestal Chassis The following are steps should be used when installing the Dedicated Server Management NIC
  • Intel S1200BT | User Guide - Page 37
    4 and Integrated BMC Web Console User Guide Hardware Installations and Initial Configuration Figure 17: Mounting the Intel® Dedicated Server Management NIC module to the PCI Slot bracket 4. Attach the cable to the cable connector on the Intel® Dedicated Server Management NIC module as shown in
  • Intel S1200BT | User Guide - Page 38
    Installations and Initial Configuration Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Figure 18: Adding the Intel® Dedicated Server Management NIC module on a 3rd Party Chassis Table 7: Intel® Server Boards RMM4 NIC Connectors Intel® Server Board RMM4 NIC connector
  • Intel S1200BT | User Guide - Page 39
    RMM4 can be configured in multiple ways:  Using BIOS setup  Using the Intel® Deployment Assistant (IDA),  Using Sysconfig (SYSCFG)  Using IPMI commands. Note: You can download the IDA and SYSCFG software from the following links:  IDA - http://www.intel.com/p/en_US/support/highlights/server/ida
  • Intel S1200BT | User Guide - Page 40
    Integrated BMC Web Console and Intel® RMM4 Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 4.1 Configuring your Server Management NIC using BIOS setup on S1200BTL 1. During POST, press to go to BIOS setup. 2. Navigate to the Server Management tab and then scroll
  • Intel S1200BT | User Guide - Page 41
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel® RMM4 Figure 19: Server Management - BMC LAN Configuration on S1200BTL Revision 2.4 29
  • Intel S1200BT | User Guide - Page 42
    and Integrated BMC Web Console User Guide 4.2 Configuring your Server Management NIC using BIOS setup on EPSD Platforms Based on Intel® Xeon® Processor E54600/2600/2400/1600/1400 Product Families 1. During POST, press to go to BIOS setup. 2. Navigate to the Server Management tab and then scroll
  • Intel S1200BT | User Guide - Page 43
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel® RMM4 Figure 20: Server Management - BMC LAN Configuration on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families Revision 2.4 31
  • Intel S1200BT | User Guide - Page 44
    Integrated BMC Web Console and the Intel® RMM4. The example will show how to configure LAN Channel 3 (Intel® RMM4 NIC). WARNING If you need to configure both LAN Channel 1 and LAN channel 3 (RMM4 Dedicated Server Management NIC), ensure that they are configured with different subnets. Note: When the
  • Intel S1200BT | User Guide - Page 45
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel® RMM4 Figure 22: IDA Configure Server: Communication Options Window No Dedicated Server Management NIC installed. Revision 2.4 33
  • Intel S1200BT | User Guide - Page 46
    23. b. If Static IP Address is selected configure the IP address, Subnet Mask and Gateway as shown in Figure 24. 3. You can also select Enable Serial Over LAN and Configure Alert on these screens. Figure 23: IDA Configure Server: Configure LAN Channel 3 (Intel® RMM4 DMN) IP Address from a DHCP
  • Intel S1200BT | User Guide - Page 47
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel® RMM4 Figure 24: IDA Configure Server: Configure LAN Channel 3 (Intel® RMM4 DMN) Static IP Address window Revision 2.4 35
  • Intel S1200BT | User Guide - Page 48
    BMC Web Console and Intel® RMM4 Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 4. [Optional] Setup the users by selecting the User Name and then clicking on Edit. The Edit User Data window is displayed. Notes: Figure 25: IDA Configure Server: Set Up Users window
  • Intel S1200BT | User Guide - Page 49
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel® RMM4 5. Edit the User information and click OK to apply configuration. Figure 26: IDA Configure Server: Edit User Information window Revision 2.4 37
  • Intel S1200BT | User Guide - Page 50
    Configuring Integrated BMC Web Console and Intel® RMM4 Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 6. Select Apply to save your settings. Figure 27: IDA Configure Server: Apply Configuration window 38 Revision 2.4
  • Intel S1200BT | User Guide - Page 51
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Configuring Integrated BMC Web Console and Intel® RMM4 Figure 28: IDA Configure Server: Applying Configuration progress window Revision 2.4 39
  • Intel S1200BT | User Guide - Page 52
    4 and Integrated BMC Web Console User Guide 7. Keep a record of the DHCP Host Name and assigned IP address. These will be needed later when you are trying to connect to the Integrated BMC Web Console. 8. In order for the configuration settings to take effect the server must be restarted. Select the
  • Intel S1200BT | User Guide - Page 53
    Console User Guide Configuring Integrated BMC Web Console and Intel® RMM4 4.4 Configuring your Server Management NIC using the Intel® System Configuration Utility (SysConfig) This section gives the basic commands needed to configure the RMM4 using SysConfig commands. This utility is supported in EFI
  • Intel S1200BT | User Guide - Page 54
    and Integrated BMC Web Console User Guide 5. Getting Started with Intel® RMM4 Operation The Intel® RMM4 module features remote KVM access and control through LAN or Internet. The Intel® Integrated BMC Web Console is part of the standard BMC firmware/Server Management Software. The Integrated BMC Web
  • Intel S1200BT | User Guide - Page 55
    display slider controls to enable the user to see the full content of each web page. 5.2 Logging In Enter the configured IP address of the Intel® RMM4 or your configured BMC on-board NIC into your web browser. In order to use a secure connection, type https:///. This will take you to the
  • Intel S1200BT | User Guide - Page 56
    tabs. Click these tabs to get specific system information and perform tasks as shown server. The tab automatically opens the 'System Information' page:  System Information  FRU Information  CPU Information (only on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product
  • Intel S1200BT | User Guide - Page 57
    Tab Function Click this tab to configure various settings for the server. The tab automatically opens the 'Network' configuration page.  Network/IPv4 Network  IPv6 Network (only on EPSD Platforms Based on Intel® Xeon® Processor E5- 4600/2600/2400/1600/1400 Product Families)  Users  Login  LDAP
  • Intel S1200BT | User Guide - Page 58
    Getting Started with Intel® RMM4 Operation Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 5.4 Online Help The Web Console user interface gives specific online help for each page. For additional information on a certain topic or group of options, click the button on
  • Intel S1200BT | User Guide - Page 59
    Remote Management Module 4 and Integrated BMC Web Console User Guide Getting Started with Intel® RMM4 Operation Figure 34: Logging Out of Integrated BMC Web Console - Step 1 Figure 35: Logging Out of Integrated BMC Web Console - Step 2 Note: Automatic Timeout -
  • Intel S1200BT | User Guide - Page 60
    keyboard and mouse of the remote host system where the Intel® RMM4 module is installed. To use the Remote Console window of your managed host system, the browser must include a Java Runtime Environment* plug-in. If the browser has no Java* support, such as with a small handheld device, the user can
  • Intel S1200BT | User Guide - Page 61
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Remote Console (KVM) Operation Click the Launch Console button to launch the redirection console and manage the server remotely. When the Launch Console button is clicked, a pop-up window is opened to download the Java
  • Intel S1200BT | User Guide - Page 62
    Operation Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide CDROM configured accordingly. 6.2 Main Window Starting the Remote Console opens an additional window as shown in Figure 38. Figure 38: Remote Console Main Window It displays the screen content of your remote server
  • Intel S1200BT | User Guide - Page 63
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Remote Console (KVM) Operation The Remote pauses redirection of keyboard, video, and mouse. The Remote Console window stops being updated. Keyboard shortcut is ALT+P.  Resume Redirection. Resume redirection after a pause.
  • Intel S1200BT | User Guide - Page 64
    Console (KVM) Operation Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 6.3.2 Remote Console combination to the remote OS. 6.3.2.1 Keyboard Language Layout The Remote Console supports the following keyboard language layouts: English, Dutch, French, German, Italian
  • Intel S1200BT | User Guide - Page 65
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Remote Console (KVM) Operation configured in Control Panel > Regional and Language Options > Languages > Text Services and Input Languages). If you are using one of the supported language keyboards, you don't have to manually
  • Intel S1200BT | User Guide - Page 66
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide On the other hand, with Linux* Java*, there is less reverse translation required by the application than under Windows* and is more likely that a mismatched configuration see the exact layouts supported for the local
  • Intel S1200BT | User Guide - Page 67
    Mouse Mode, selected on the web page Configuration > Mouse Mode. Absolute Mouse Mode does not require calibration. Shortcut is ALT+T.  Mouse Mode. This option is only available on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families. See Figure 46. This allows
  • Intel S1200BT | User Guide - Page 68
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 6. In this step, the mouse acceleration settings on the remote server will be discovered. The local mouse cursor is displayed in RED and timeouts. If you experience performance problems when operating over a slow connection
  • Intel S1200BT | User Guide - Page 69
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide of virtual devices only appears on the remote OS or BIOS setup menus when some media redirection is active. The USB device to allow the loading of custom device drivers during remote OS installation which may require a floppy
  • Intel S1200BT | User Guide - Page 70
    Remote Console (KVM) Operation Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 6.4 Remote Console Status Line The status line at the bottom of the Remote Console screen shows the console state as shown in Figure 50. As
  • Intel S1200BT | User Guide - Page 71
    Management Module 4 and Integrated BMC Web Console User Guide Intel® Integrated BMC Web Console Options 7. Intel® Integrated BMC Web Console Options This chapter gives you This includes the power status and the version of firmware, Figure 52 shows the details for a S1200BTL system. Revision 2.4 59
  • Intel S1200BT | User Guide - Page 72
    of the Sensor Data Record. Major and minor revision of the Management Engine firmware. On an EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families you also get an Overall System Health Indication. See Figure 53 for details. These are a general indication
  • Intel S1200BT | User Guide - Page 73
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Intel® Integrated BMC Web Console Options Figure 53: System Information Page on EPSD Platforms Based on Intel® Xeon® Processor E54600/2600/2400/1600/1400 Product Families Revision 2.4 61
  • Intel S1200BT | User Guide - Page 74
    ® Integrated BMC Web Console Options Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 7.1.2 Field Replaceable Unit (FRU) Information Page The Field Replaceable Unit (FRU) Information page displays information from the FRU repository of the host system. See Figure
  • Intel S1200BT | User Guide - Page 75
    Module 4 and Integrated BMC Web Console User Guide Intel® Integrated BMC Web Console Options 7.1.3 System your client system. The file can then be sent to your system manufacturer or an Intel® support engineer for analysis. Figure 55: System Information System Debug Log Page on S1200BTL platforms
  • Intel S1200BT | User Guide - Page 76
    c. Integrated Memory Controller (iMC) and Integrated I/O (IIO) module registers. BMC configuration data BMC FW debug log (that is, SysLog) - Captures FW debug messages. 7.1.3.2 System Debug Log Page on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families
  • Intel S1200BT | User Guide - Page 77
    Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families A list not include any "event-only" sensors. (All BIOS sensors and some BMC and ME sensors are "event are saved in both hexadecimal and text format. CPU/memory register data useful for diagnosing the cause of the
  • Intel S1200BT | User Guide - Page 78
    table is captured from the last boot. c. PCI configuration data for on-board devices and add-in cards. The first 256 bytes of PCI configuration data is captured for each device for each boot. d. System memory map. The system memory map is provided by BIOS on the current boot. This includes the EFI
  • Intel S1200BT | User Guide - Page 79
    Management Module 4 and Integrated BMC Web Console User Guide Intel® Integrated BMC Web Console Options 7.1.4 DIMM Information Page The DIMM Information page displays information on DIMM modules installed on the host system. See Figure 57
  • Intel S1200BT | User Guide - Page 80
    Management Module 4 and Integrated BMC Web Console User Guide 7.1.5 CPU Information Page on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families The CPU Information page displays information on the processors that are installed on EPSD Platforms Based on
  • Intel S1200BT | User Guide - Page 81
    Console User Guide Intel® Integrated BMC Web Console Options 7.2 Server Health Tab The Server Health tab shows you data related to the server's health, such shown in Figure 59 and Figure 60. By default the sensor readings are updated every 60 seconds but this can be changed by entering a value in
  • Intel S1200BT | User Guide - Page 82
    Integrated BMC Web Console Options Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Figure 60: Server Health Sensor Readings Page (Thresholds displayed) The following table lists the options available in this page: Table 11: Server Health Sensor Readings Options Option
  • Intel S1200BT | User Guide - Page 83
    lists the options available in this page: Table 12: Server Health Event Log Options on S1200BTL platforms Option Task Event Log clear the event logs. On an EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families you also get a Save Event Log button. See Figure
  • Intel S1200BT | User Guide - Page 84
    ® Remote Management Module 4 and Integrated BMC Web Console User Guide Figure 62: Server Health Event Log Page on EPSD Platforms Based on Intel® Xeon® Processor E54600/2600/2400/1600/1400 Product Families 7.2.3 Power Statistics Page The Power Statistics page displays the systems power statistics
  • Intel S1200BT | User Guide - Page 85
    Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families IPv6, VLAN, and Node Manager can also be configured. Click on the Configuration Network or IPv4 settings page is used to configure the IPv4 network settings for the server management LAN interface to the BMC controller. See Figure
  • Intel S1200BT | User Guide - Page 86
    ® Remote Management Module 4 and Integrated BMC Web Console User Guide Figure 65: Configuration IPv4 Network Settings Page on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families WARNING Each network controller should be on a different subnet than all other
  • Intel S1200BT | User Guide - Page 87
    BMC Web Console User Guide Intel® Integrated BMC Web Console Options Option LAN Channel drop-down box MAC Address IP address radio buttons IP Address Subnet Mask Gateway Primary DNS Server Secondary DNS Server Save button Task Used to select the Channel that you would like to configure the network
  • Intel S1200BT | User Guide - Page 88
    Figure 66: Configuration IPv6 Page on EPSD Platforms Based on Intel® Xeon® Processor E54600/2600/2400/1600/1400 Product Families WARNING functionality on the primary network controller channel it will randomly failover to any of the other network controller channels that are connected and seen by
  • Intel S1200BT | User Guide - Page 89
    enable LAN Failover. Used to select the Channel that you would like to configure the network settings. Lists the LAN Channel(s) available for server management. The LAN channels describe the physical NIC connection on the server.  Intel® RMM (BMC LAN Channel 3) is the add-in RMM4 NIC.  Baseboard
  • Intel S1200BT | User Guide - Page 90
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 7.3.3 Users page The User List page lists the configured for details. Figure 67: Configuration User List Page This page allows the operator to configure the IPMI users and privileges for this server:  UserID 1 (anonymous
  • Intel S1200BT | User Guide - Page 91
    ® Remote Management Module 4 and Integrated BMC Web Console User Guide Intel® Integrated BMC Web Console Options Figure 68: Configuration Users Add User Page To modify a user, select a user in the list and click Modify User. This allows you to change the Password, Enable Access,
  • Intel S1200BT | User Guide - Page 92
    for one minute. Press the Save button to save any changes. Figure 70: Configuration Login Security Settings Page on S1200BTL platforms For EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families you can also force the interface to HTTP Secure mode by selecting
  • Intel S1200BT | User Guide - Page 93
    Management Module 4 and Integrated BMC Web Console User Guide Intel® Integrated BMC Web Console Options Figure 71: Configuration Login Security Settings Page on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families 7.3.5 LDAP Settings Page To enable/disable
  • Intel S1200BT | User Guide - Page 94
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide The following table lists the options available in this page: Table 15: Configuration required information to access the LDAP server. Specify the LDAP Port The IP address of LDAP server IP Address made of 4 numbers
  • Intel S1200BT | User Guide - Page 95
    this page is used to enable and configure the VLAN private network settings on the selected server management LAN channels. Figure 73: Configuration VLAN Settings on EPSD Platforms Based on Intel® Xeon® Processor E54600/2600/2400/1600/1400 Product Families The following table lists the options
  • Intel S1200BT | User Guide - Page 96
    User Guide Option VLAN Priority (0 - 7) Save button 7.3.7 SSL Upload Page Used to set the VLAN Priority. Click to save the current settings Task Use this page to upload an SSL certificate and privacy key, which allows the device to be accessed in secured mode. Figure 74: Configuration SSL
  • Intel S1200BT | User Guide - Page 97
    type selection used during a redirection session: Table 17: Configuration Remote Session Options Option Task Enable KVM Encryption Enable Media any changes. On an EPSD Platforms Based on Intel® Xeon® Processor E5 4600/2600/2400/1600/1400 Product Families you can select the Encryption mode and
  • Intel S1200BT | User Guide - Page 98
    Guide Figure 76: Configuration Remote Session Page on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Configuration Remote Session Options Task Disable or select encryption mode on KVM or Media data during a redirection session. Choose any one from the supported
  • Intel S1200BT | User Guide - Page 99
    position displacement sent to the server. Use this mode for Linux* OS. Click Save to use selected mode. Figure 77: Configuration Mouse Mode Setting Page on S1200BTL platforms On an EPSD Platforms Based on Intel® Xeon® Processor E5 4600/2600/2400/1600/1400 Product Families the Redirection Console
  • Intel S1200BT | User Guide - Page 100
    calculated displacement from the local mouse in the center position, sent to the server. Under this mode ALT+C should be used to switch between Host and 78: Configuration Mouse Mode Setting Page on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families 7.3.9.1
  • Intel S1200BT | User Guide - Page 101
    ® Remote Management Module 4 and Integrated BMC Web Console User Guide Intel® Integrated BMC Web Console Options will switch between using the : KVM window with Mouse Other Mode selected on EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families Revision 2.4 89
  • Intel S1200BT | User Guide - Page 102
    Console User Guide 7.3.10 Keyboard Macros Page Macro buttons can be defined on this page that will appear in the upper right corner of the KVM Remote Console application window. Each button is assigned a sequence of keys to execute when the button is clicked. Figure 80: Configuring Keyboard Macros
  • Intel S1200BT | User Guide - Page 103
    Management Module 4 and Integrated BMC Web Console User Guide Intel® Integrated BMC Web Console Options A '+' indicates must also be escaped as '\\'. Note: The key sequences are sent to the target as scan codes that get interpreted by the target OS, so they will be affected by modifiers such as
  • Intel S1200BT | User Guide - Page 104
    BMC Web Console Options Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 7.3.11 Alerts Page Use this page to configure which system events an alert should be sent for and the destination for the alerts. Up to two destinations can be selected for each LAN channel. Figure 81
  • Intel S1200BT | User Guide - Page 105
    to. Up to 2 destinations can be selected for each LAN channel. Click to use selected setup. After configuring select this to send a test alert. On an EPSD Platforms Based on Intel® Xeon® Processor E5 4600/2600/2400/1600/1400 Product Families there is an additional option to Globally Enable Platform
  • Intel S1200BT | User Guide - Page 106
    Web Console Options Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 7.3.12 Alert Email Page Use this page to configure the parameter for Alert Emails. Option LAN Channel SMTP Server IP. Sender Address Local Hostname Save button Figure 83: Configuration Alert Email Page
  • Intel S1200BT | User Guide - Page 107
    Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families On EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families this page is used to view, add, and configure periods, correction timeouts, or aggressive CPU throttling settings. Revision 2.4 95
  • Intel S1200BT | User Guide - Page 108
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide power limit, in watts. If enabled, you may configure policy suspend periods. Each policy may have up to of POST.  Aggressive CPU Power Correction: AUTO - Use of T-states and memory throttling controlled by policy exception
  • Intel S1200BT | User Guide - Page 109
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide Intel® Integrated BMC Web Console Options Figure 85: Configuration Node Manager Page with Use Poilicy Suspend Period selected Revision 2.4 97
  • Intel S1200BT | User Guide - Page 110
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide 7.4 Remote Control tab The Remote Control tab helps you perform the following remote operations on the server:  Console redirection  Server the server remotely. Note: Java Run-Time Environment* (JRE* Version 6 Update 22 or
  • Intel S1200BT | User Guide - Page 111
    Power OFF Server Select option to. immediately power off the host Power ON Server Select option to power on the host Power Cycle Server Select option Based on Intel® Xeon® Processor E5 4600/2600/2400/1600/1400 Product Families you have two additional options, one is to Force-enter BIOS Setup on
  • Intel S1200BT | User Guide - Page 112
    Intel® Remote Management Module 4 and Integrated BMC Web Console User Guide For the Graceful OS Shutdown to function properly the OS must be ACPI aware and be configured Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families Option Task Reset Server Force-Enter BIOS Setup
  • Intel S1200BT | User Guide - Page 113
    on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product Families On EPSD Platforms Based on Intel® Xeon® Processor E5-4600/2600/2400/1600/1400 Product to Power ON or Power Off. Reset Button is used to reset the server while system is ON. When Chassis ID button is pressed then the chassis
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113

Intel
®
Remote Management Module 4
and Integrated BMC Web Console User
Guide
Revision 2.4
May 2012
Enterprise Platforms and Services Division