    Intel® Server System SC5400RA User's Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number D36227-002
  • Intel SC5400RA | User Guide - Page 2
    be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits. Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States
  • Intel SC5400RA | User Guide - Page 3
    documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel® Server Deployment Toolkit 2.0 CD y/o en http:// support.intel.com/support/motherboards/server/sb/cs-010770.htm. Intel® Server System SC5400RA User's Guide iii
  • Intel SC5400RA | User Guide - Page 4
    open the chassis, add, board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. iv Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 5
    the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Server System SC5400RA User's Guide v
  • Intel SC5400RA | User Guide - Page 6
    vi Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 7
    components you may need, troubleshooting information, and instructions on how to add and replace components on the Intel® Server System SC5400RA. For the latest version of this manual, see http:// support.intel.com/support/motherboards/server/SC5400RA/. Manual Organization Chapter 1 provides a brief
  • Intel SC5400RA | User Guide - Page 8
    about which accessories, memory, processors, and third-party hardware have been tested and can be used with your board, and for ordering information for Intel products, see http://support.intel.com/support/motherboards/server/SC5400RA/ compat.htm. viii Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 9
    Intel® Server System SC5400RA Technical Product Specification Intel® Server System SC5400RA Quick Start User's Guide in the product box A link to the SMaRT Tool is available under "Other Resources" at the right side of the screen at: http://support.intel.com/support/motherboards/server/SC5400RA
  • Intel SC5400RA | User Guide - Page 10
    x Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 11
    Tools and Supplies Needed 23 System References 23 Removing and Installing the Chassis Cover 24 Removing the Chassis Cover 24 Installing the Chassis Cover 25 Removing and Installing the Front Bezel 26 Removing the Bezel Assembly (Pedestal Only 26 Intel® Server System SC5400RA User's Guide xi
  • Intel SC5400RA | User Guide - Page 12
    Power Supply 86 Replacing the Power Distribution Board 88 Replacing the CMOS Battery 97 Replacing the Server Board 99 Removing the Server Board 99 Installing a Server Board 102 Chapter 3: System Utilities 105 Using the BIOS Setup Utility 105 xii Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 13
    Server 134 Sicherheitshinweise und Vorsichtsmaßnahmen 134 Zielbenutzer der Anwendung 135 Standortauswahl 135 Handhabung von Geräten 135 Warnungen zu Netzspannung und Elektrizität 136 Warnhinweise für den Systemzugang 137 Warnhinweise für Racks 138 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 14
    163 Other Markings ...166 Regulated Specified Components 167 End-of-Life / Product Recycling 168 Appendix D: Getting Help 169 World Wide Web ...169 Telephone ...169 xiv Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 15
    for Intel® Server System Subassembly Products 173 Extent of Limited Warranty 174 Warranty Limitations and Exclusions 174 Limitations of Liability 174 How to Obtain Warranty Service 175 Telephone Support 175 Returning a Defective Product 175 Intel® Server System SC5400RA User's Guide xv
  • Intel SC5400RA | User Guide - Page 16
    xvi Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 17
    1. Intel® Server System SC5400RA 1 Figure 2. Component Locations 4 Figure 3. Front Control Panel ...5 Figure 4. Intel® Local Control Panel Features 7 Figure 5. Server System Back 8 Figure 6. Back Panel Connectors and LEDs 9 Figure 7. Optional Peripherals 10 Figure 8. Server Board Connector
  • Intel SC5400RA | User Guide - Page 18
    76 Figure 84. Installing a Heatsink 77 Figure 85. Preparing System for Addition of Intel® RMM NIC 79 Figure 86. Installing Intel® RMM NIC 80 Figure 87. Installing the Intel® Remote Management Module 81 Figure 88. Removing the Intel® RMM NIC 82 xviii Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 19
    Board 91 Figure 99. Removing Power Distribution Board 92 Figure 100. Inserting Power Distribution Board 93 Figure 101. Securing Power Distribution Board Installing Memory Riser Cage 102 Figure 110. BIOS Bank Select Jumper in Force Lower Bank Position Intel® Server System SC5400RA User's Guide xix
  • Intel SC5400RA | User Guide - Page 20
    xx Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 21
    List of Tables Table 1. Server System Features 2 Table 2. Front Control Panel LED Descriptions 6 Table 3. NIC LEDs ...9 Table 4. Setup Compliance Markings 158 Table 8. Product Ecology Compliance Markings 164 Table 9. Other Markings ...166 Intel® Server System SC5400RA User's Guide xxi
  • Intel SC5400RA | User Guide - Page 22
    xxii Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 23
    of the Intel® Server System SC5400RA. This chapter provides a list of the server system features, and diagrams that show the location of important components and connections in the server system. AF001483 Figure 1. Intel® Server System SC5400RA Intel® Server System SC5400RA User's Guide 1
  • Intel SC5400RA | User Guide - Page 24
    -Core Intel® Xeon® processors with a 1066-, or 1333MHz front side bus • DDR2-533 and DDR2-667 FBDIMM sockets that support a total of 64 MB memory • Quad-channel memory architecture • Intel® 6321ESB I/O Controller Hub • Intel® 5000P Memory Controller Hub 2 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 25
    the Intel® Local Control Panel (optional component sold separately) • Support for the Intel® Remote Management Module (optional component sold separately) • Support for Intel® System Management software • Intel® Light-Guided Diagnostics on field replaceable units Intel® Server System SC5400RA User
  • Intel SC5400RA | User Guide - Page 26
    6. Processor air duct 7. Fixed fan - large 8. Fixed fan - small 9. Hard drive cage release mechanism 10. Front panel controls 11. 5.25-inch device bays (three) 12. Front panel USB / Serial B connectors 13. Six-drive fixed drive cage Figure 2. Component Locations 4 Intel® Server System SC5400RA
  • Intel SC5400RA | User Guide - Page 27
    Front Control Panel The following figure shows the features available on the front control panel. The Intel® Local Control Panel is optional. A B C F G D E H I TP00701 A. ID H. Status LED (bi-color) I. NMI Button Figure 3. Front Control Panel Intel® Server System SC5400RA User's Guide 5
  • Intel SC5400RA | User Guide - Page 28
    Power on Power off System ready System ready, but degraded: some CPU fault, DIMM killed Condition during BMC reset. On Blink Off Blink Server identification; toggled by ID button or software Server identification; toggled by ID button or software 6 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 29
    A B C D E AF000955 Callout Function A. LCD display (variable content) B. LCD up navigation button C. LCD down navigation button D. LCD backup level navigation button E. LCD command enter button Figure 4. Intel® Local Control Panel Features Intel® Server System SC5400RA User's Guide 7
  • Intel SC5400RA | User Guide - Page 30
    Figure 6 on page 9 D. PCI card area E. Rear Serial B Connector (optional) Figure 5. Server System Back The diagram and table show the back panel connectors and LEDs. For information about the LEDs, see "Intel® Light-Guided Diagnostics" on page 15. 8 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 31
    connection is in place Transmit / receive activity is occurring 10 Mbps connection (if left LED is on or blinking) 100 Mbps connection 1000 Mbps connection Intel® Server System SC5400RA User's Guide 9
  • Intel SC5400RA | User Guide - Page 32
    Peripheral Devices The server system provides locations and hardware for installing hard drives, a floppy drive, a CD-ROM drive, or a DVD-ROM with 6-drive hot-swap drive cage. E. Release mechanism for hard drive cage Figure 7. Optional Peripherals 10 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 33
    Server Board Connector and Header Locations GI A B CDE F H J KL OO M NN MM P. DIMM riser sockets (see Figure 11 on page 20) Q. Processor 1 socket R. Processor 2 socket S. System fan 4 header T. System fan 3 header 4 JJ. SATA 5 KK. USB port Intel® Server System SC5400RA User's Guide 11
  • Intel SC5400RA | User Guide - Page 34
    header BB. Intel® Local Control Panel header LL. Front control panel header MM. SATA_Key: SATA RAID 5 key connector NN. Serial B / emergency management port header OO. Chassis intrusion header Figure 8. Server Board Connector and Component Locations 12 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 35
    next server reset. These pins should not be jumpered for normal operation. To clear the CMOS: Power down the server, leaving AC power connected. Place the jumper on pins 2 - 3 for 5 to 10 seconds. Move the jumper back to pins 1 - 2. Power on the server. Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 36
    . Power down the server. Move the jumper back to pins 1 - 2. Power on the server. Disable force update: These pins should be jumpered for normal operation. Enable force update: Jumpering these pins forces a BMC update. Figure 9. Configuration Jumpers 14 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 37
    LED. The sequence of lit POST LEDs is used to identify specific errors that might occur during the boot process. See the appendix of the Technical Product Specification for a description of how to read these LEDs. Intel® Server System SC5400RA User's Guide 15
  • Intel SC5400RA | User Guide - Page 38
    Processor 1 fault LED J. DIMM riser card 1 fault LEDs K. DIMM riser card 2 fault LEDs Function POST LED. The sequence of lit POST LEDs is used to identify specific errors that might occur during the boot process. See the appendix of the Technical 16 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 39
    the tool-less rail kit, ARIGRACK) Storage Device Options The Intel® Server System SC5400RA supports the following drive options: • Optical hard disk drives • Six SATA ports at 3 GB/s • Parallel ATA (IDE): The server board includes one IDE connector. Intel® Server System SC5400RA User's Guide 17
  • Intel SC5400RA | User Guide - Page 40
    links under "Additional Information and Software" on page ix. Processor One or two Multi-Core Intel®Xeon® processors 5000, 5100, or 5300 sequence. For a list of supported processors, see the links under "Additional Information and Software" on page ix. 18 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 41
    minimum configuration) - DIMM_C2 - DIMM_C3 - DIMM_C4 • Channel D is in the right riser card, nearest to the right side of the server board. This channel consists of - DIMM_D1 (must be populated for minimum configuration) - DIMM_D2 - DIMM_D3 - DIMM_D4 Intel® Server System SC5400RA User's Guide 19
  • Intel SC5400RA | User Guide - Page 42
    the right C1 DIMM_C1 C2 DIMM_C2 C3 DIMM_C3 C4 DIMM_C4 D1 DIMM_D1 D2 DIMM_D2 D3 DIMM_D3 D4 DIMM_D4 G Channel D H Channel C Figure 11. DIMM Sockets 20 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 43
    DIMM heat spreader (FDHS) FBDIMMs are required. During the boot process, FBDIMMs that do not meet the population requirements are disabled. For a complete list of supported FBDIMMs, see the links under "Additional Information and Software" on page ix. Intel® Server System SC5400RA User's Guide 21
  • Intel SC5400RA | User Guide - Page 44
    FBDIMMs are used for mirroring. Memory mirroring and memory sparing are mutually exclusive. Only one can be active at a time. See the Intel® Server Board Technical Product Specification for additional information regarding the memory sub-system. 22 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 45
    , pay close attention to the "Safety Information" on page iii. This document provides instructions for adding and replacing server system components. Tools and Supplies Needed • Phillips* (cross head) screwdriver (#1 bit and #2 bit) • Needle nosed pliers • Antistatic wrist strap and conductive
  • Intel SC5400RA | User Guide - Page 46
    "A" in the following figure. 5. While holding in the blue button at the top of the chassis (see letter "B"), slide the top cover back until it stops. 6. Lift the cover outward to remove it. B A B A Figure 12. Removing the Chassis Cover AF000555 24 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 47
    the chassis. 2. Latch the cover securely to the chassis. 3. If the chassis will be re-shipped, secure the cover to the chassis with the access cover screw. See letter "A" in the following figure. A A Figure 13. Installing the Chassis Cover AF000572 Intel® Server System SC5400RA User's Guide 25
  • Intel SC5400RA | User Guide - Page 48
    letter "C". If the bezel assembly does not immediately disconnect from the chassis, tap the left-hand side of the bezel assembly to disengage the bezel hooks on the righthand side of the chassis. A C A B AF000557 Figure 14. Removing the Front Bezel 26 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 49
    Bezel (Pedestal Only) Caution: This step applies to a pedestal configuration system only. For instructions on installing a bezel in a rack-mount configuration, see the Rack Conversion kit Installation Guide: Intel® Server Chassis SC5400. 1. Open the outer bezel door of the bezel assembly (see letter
  • Intel SC5400RA | User Guide - Page 50
    this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see "Removing the Chassis Cover" on page 24. 4. Remove B TP001490 Figure 16. Removing Six-drive Fixed Drive Cage 28 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 51
    Figure 17. Unlocking and Opening Upper Door of Fixed Drive Cage 8. Open the lower door. AF000580 Figure 18. Opening Lower Door of Fixed Drive Cage Intel® Server System SC5400RA User's Guide 29
  • Intel SC5400RA | User Guide - Page 52
    front of the hard drive and facing towards each other, as shown in the figure. AF000582 Figure 20. Attaching Device Slides to Hard Drive 30 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 53
    additional hard drives into the drive cage. 13. Close the lower door of drive cage. . AF000584 Figure 22. Closing Lower Door of Fixed Drive Cage Intel® Server System SC5400RA User's Guide 31
  • Intel SC5400RA | User Guide - Page 54
    , see "Removing and Installing the Front Bezel" on page 26. 19. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 20. Plug all peripheral devices and the AC power cable into the server. 21. Power up the server. 32 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 55
    this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see "Removing the Chassis Cover" on page 24. 4. Remove Open the upper door of the drive cage. See letter "B". Intel® Server System SC5400RA User's Guide 33
  • Intel SC5400RA | User Guide - Page 56
    of Fixed Drive Cage 10. Remove the drive/slide assembly from the drive cage. AF000588 Figure 28. Removing Drive/Slide Assembly from Drive Cage 34 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 57
    Drive Cage 12. Close the lower door of drive cage. AF000948 Figure 30. Closing Lower Door of Fixed Drive Cage 13. Close the upper door. Intel® Server System SC5400RA User's Guide 35
  • Intel SC5400RA | User Guide - Page 58
    AF000949 Figure 31. Closing Upper Door of Fixed Drive Cage 36 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 59
    , see "Removing and Installing the Front Bezel" on page 26. 18. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 19. Plug all peripheral devices and the AC power cable into the server. 20. Power up the server. Intel® Server System SC5400RA User's Guide 37
  • Intel SC5400RA | User Guide - Page 60
    system will have either hot-swap or fixed drives. If your server system has fixed drives, see "Installing and Removing Fixed Hard Drive(s)" on page 28 for drive carrier. Remove the plastic air baffle. AF000590 Figure 34. Removing Plastic Air Baffle 38 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 61
    cage. Once inserted, rotate the black lever upwards to latch the drive carrier into position. AF000592 Figure 36. Inserting Drive Carrier into Hot Swap Cage Intel® Server System SC5400RA User's Guide 39
  • Intel SC5400RA | User Guide - Page 62
    the hard drive to the drive carrier. Remove the hard drive from the drive carrier. AF000595 Figure 38. Removing Hard Drive from Drive Carrier 40 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 63
    Plastic air baffles are necessary in all empty drive carriers to ensure proper airflow within the server system. AF000950 Figure 39. Installing Plastic Air Baffle in Drive Carrier 4. With the black Figure 40. Inserting Drive Carrier into Hot Swap Cage Intel® Server System SC5400RA User's Guide 41
  • Intel SC5400RA | User Guide - Page 64
    server system and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see "Removing the Chassis Cover" on page 24. 4. Remove the front bezel. For instructions Figure 41. Removing Drive Cage from Drive Bay 42 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 65
    slimline floppy drive into the bottom tray of the drive cage. See the figure below. AF000494 Figure 43. Inserting Slimline Floppy Drive into Drive Cage Intel® Server System SC5400RA User's Guide 43
  • Intel SC5400RA | User Guide - Page 66
    slimline CD-ROM / DVD-ROM drive. See letter "B" in the figure below. A AF000490 B Figure 45. Attaching Backplane to Slimline CD-ROM / DVD-ROM Drive 44 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 67
    cage top downward at the left side to engage the left tabs. See letter "C". C A C B AF001519 Figure 47. Installing the Cage Top to the Drive Cage Intel® Server System SC5400RA User's Guide 45
  • Intel SC5400RA | User Guide - Page 68
    Cage to Drive Bay . 28. Press in on the side latches to remove the EMI shield/slide assembly from the upper device bay of the server system. See letter "A" in the following figure. 46 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 69
    Rails to Slimline Drive Assembly 30. Slide the slimline drive assembly into the server chassis. See the following figure. Make sure that the drive rails are in the correct slots in the chassis. A AF000633 Figure 52. Inserting Slimline Drive Assembly Intel® Server System SC5400RA User's Guide 47
  • Intel SC5400RA | User Guide - Page 70
    , see "Removing and Installing the Front Bezel" on page 26. 35. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 36. Plug all peripheral devices and the AC power cable into the server. 37. Power up the server. 48 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 71
    this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see "Removing the Chassis Cover" on page 24. 4. Remove DVD-ROM / CD-ROM Drive Assembly from Upper Device Bay Intel® Server System SC5400RA User's Guide 49
  • Intel SC5400RA | User Guide - Page 72
    , see "Removing and Installing the Front Bezel" on page 26. 10. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 11. Plug all peripheral devices and the AC power cable into the server. 12. Power up the server. 50 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 73
    beginning of this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see "Removing the Chassis Cover" on page 24. 4. Remove the dimples on the DVD-ROM or CD-ROM drive. Intel® Server System SC5400RA User's Guide 51
  • Intel SC5400RA | User Guide - Page 74
    , see "Removing and Installing the Front Bezel" on page 26. 11. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 12. Plug all peripheral devices and the AC power cable into the server. 13. Power up the server. 52 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 75
    If not replacing with another drive, re-attach pair of slides to an EMI shield and reinsert EMI shield/slide assembly into the server system for proper airflow. See the following figure. AF000605 Figure 59. Reinserting Empty EMI Shield/Slide Assembly Intel® Server System SC5400RA User's Guide 53
  • Intel SC5400RA | User Guide - Page 76
    card from the card guide. 1. Observe the safety and ESD precautions in "Safety Information" on page 129. 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord from the server. 4. Remove the chassis cover. For instructions, see "Removing the
  • Intel SC5400RA | User Guide - Page 77
    connectors. Place the add-in board on an anti-static surface while you record the type and serial number of the add-in board in your equipment log. 10. Set the jumpers or switches on the board according to the add-in card manufacturer's instructions. Intel® Server System SC5400RA User's Guide 55
  • Intel SC5400RA | User Guide - Page 78
    slot on the server board. See letter "A" in the following figure. 12. Close the back panel PCI add-in card retention device. See letter "B". A B AF000599 Figure 61. Installing Add-in Card 13. Repeat steps 6 through 12 to install any other add-in cards. 56 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 79
    , see "Removing and Installing the Front Bezel" on page 26. 17. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 18. Plug all peripheral devices and the AC power cable into the server. 19. Power up the server. Intel® Server System SC5400RA User's Guide 57
  • Intel SC5400RA | User Guide - Page 80
    card from the card guide. 1. Observe the safety and ESD precautions in "Safety Information" on page 129. 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord from the server. 4. Remove the chassis cover. For instructions, see "Removing the
  • Intel SC5400RA | User Guide - Page 81
    slot on the server board. Place the removed PCI add-in board in an antistatic chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 15. Plug all peripheral devices and the AC power cable into the server. 16. Power up the server. Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 82
    from the server. 4. Remove the chassis cover. For instructions, see "Removing the Chassis Cover" on page 24. 5. Loosen the thumbscrew on the DIMM cage. See letter "A" in the following figure. 6. Lift the DIMM cage cover. See letter "B" in the figure. 60 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 83
    B A Figure 64. Opening DIMM Cage AF001406 Intel® Server System SC5400RA User's Guide 61
  • Intel SC5400RA | User Guide - Page 84
    figure. DIMMs must be installed in sockets DIMM_A1 and DIMM_B1 on memory riser card 1, and in sockets DIMM_C1 and DIMM_D1 on memory riser card 2. 62 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 85
    2, at the right C1 DIMM_C1 C2 DIMM_C2 C3 DIMM_C3 C4 DIMM_C4 D1 DIMM_D1 D2 DIMM_D2 D3 DIMM_D3 D4 DIMM_D4 G Channel D H Channel C Figure 66. DIMM Sockets Intel® Server System SC5400RA User's Guide 63
  • Intel SC5400RA | User Guide - Page 86
    . See letter "C" in Figure 67. 14. Make sure the clips latch firmly in place. See letter "D" in Figure 67. C D B A TP000425 Figure 67. Installing FBDIMMs 64 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 87
    cards to seat them into the sockets on the server board. 17. Close the door on the memory cage and tighten the thumbscrew. 18. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 19. Reconnect the AC power cord. Intel® Server System SC5400RA User's Guide 65
  • Intel SC5400RA | User Guide - Page 88
    the server. 3. Remove the AC power cord from the server. 4. Remove the chassis cover. For instructions, see "Removing the Chassis Cover" on page 24. 5. Loosen the thumbscrew to open the memory riser cage. B A Figure 69. Opening DIMM Cage AF001406 66 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 89
    memory board into the socket on the server board. 10. Close the door on the memory cage and tighten the thumbscrew on the cage. 11. Replace the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25 12. Reconnect the AC power cord. Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 90
    the touch points on the processor air duct to disengage it from the server system. See letter "A" in the following figure. 5. Lift the processor air duct from the server system. See letter "B". B A AF001506 Figure 71. Removing the Processor Air Duct 68 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 91
    Processor Air Duct 1. Set the processor air duct into place, making sure the tabs on the processor air duct engage their matching slots and hooks in the chassis. See letters "A" and "B" in the figure below. A B AF001507 Figure 72. Installing the Air Duct Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 92
    server. 3. Disconnect the AC power cord from the server. 4. Remove the chassis cover. For instructions, see "Removing the Chassis Cover" on page 24. 5. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct" on page 68. 70 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 93
    heatsinks. Locate the heatsinks / processor sockets. See Figure 73. A B AF001416 Callout Processor Socket Callout Processor Socket A. Heatsink and CPU_2 B. Heatsink and CPU_1 socket socket Figure 73. Locating Processor Sockets / Heatsinks Intel® Server System SC5400RA User's Guide 71
  • Intel SC5400RA | User Guide - Page 94
    lever. See Figure 75. AF000095 Figure 75. Opening Processor Socket Lever 9. Push down on the rear tab of the load plate to swing the front of the load plate up slightly. Fully open the load plate. See Figure 76. Figure 76. Opening Load Plate AF000096 72 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 95
    the socket lever. Push downward on the socket lever while pushing it toward the center of the processor socket to engage it under the hook on the processor socket. 15. Install the heatsink(s). See "Installing a Heatsink" on page 76 for instructions. Intel® Server System SC5400RA User's Guide 73
  • Intel SC5400RA | User Guide - Page 96
    lever. See Figure 79. AF000095 Figure 79. Opening Processor Socket Lever 8. Push down on the rear tab of the load plate to swing the front of the load plate up slightly. Fully open the load plate. See Figure 80. Figure 80. Opening Load Plate AF000415 74 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 97
    from Socket 10. Store the processor in the packaging materials in which it came. 11. Install the protective cover over the load plate if a replacement processor will not be installed. AF000417 Figure 82. Installing Protective Cover onto Load Plate Intel® Server System SC5400RA User's Guide 75
  • Intel SC5400RA | User Guide - Page 98
    1. Use the syringe to apply thermal grease to the top of the processor. AF001487 Figure 83. Applying Thermal Grease 2. Set the heatsink over the processor socket, lining up the four captive screws with the four posts surrounding the processor socket. 76 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 99
    installed over each installed processor. Doing so will cause your server to overheat and may cause permanent damage. • The server system must be operated with both heat sinks installed, regardless of whether one or two processors are installed. Intel® Server System SC5400RA User's Guide 77
  • Intel SC5400RA | User Guide - Page 100
    system. If it does not pull up easily, make sure the screws are fully loosened and twist the heat sink slighly again if a processor is installed beneath the heatsink. Do not force the heatsink from the processor. Doing so could damage the processor. 78 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 101
    . See letter "B" in the figure below. 9. Attach the RMM NIC cable between the RMM NIC connector on the server board and the connector on the RMM NIC. The server board connector is located between PCI Express slots 3 and 4. See letter "C" in the figure. Intel® Server System SC5400RA User's Guide 79
  • Intel SC5400RA | User Guide - Page 102
    "A" in the figure below. The standoff installs on the under side of the Intel® RMM board. 11. Attach the Intel® RMM board to the server board connector and snap the standoff into the matching hole on the server board. See letter "B" in the figure. 80 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 103
    the Chassis Cover" on page 24. 5. Disconnect the Intel® RMM NIC cable from the server board and from the RMM NIC. See letter "A" in the following figure. 6. Lift the bracket containing the RMM NIC from the server system. See letter "B" in the figure. Intel® Server System SC5400RA User's Guide 81
  • Intel SC5400RA | User Guide - Page 104
    A B Figure 88. Removing the Intel® RMM NIC AF001526 7. Lift the Intel® RMM board from the server system. See the figure below. AF001511 Figure 89. Removing the Intel® Remote Managemrnt Module 82 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 105
    you must first take the server out of service, turn off all peripheral devices chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 13. Plug all peripheral devices and the AC power cable into the server. 14. Power up the server. Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 106
    place. 8. Connect the fan power cable to the server board. 9. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 10. Plug all peripheral devices and the AC power cable into the server. 11. Power up the server. 84 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 107
    the Chassis Cover" on page 24. 1. Remove the screws from the filler panel. See letter "A" in the following figure. 2. Lift the power supply filler panel from the system. See letter "B". A A B AF000602 Figure 91. Removing the Power Supply Filler Panel Intel® Server System SC5400RA User's Guide 85
  • Intel SC5400RA | User Guide - Page 108
    supply to the server system. See letter "A" in the following figure. 3. Press on green latch while pulling on handle to remove power supply from the server system. See letter "B" in the figure. A B AF000956 Figure 93. Removing a Hot-swap Power Supply 86 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 109
    to another location. See letter "A" in the following figure. A AF000603 Figure 94. Installing Hot Swap Power Supply 6. Connect the power cable to the power supply. Intel® Server System SC5400RA User's Guide 87
  • Intel SC5400RA | User Guide - Page 110
    7 for the second hot swap power supply if one is installed. A B AF000956 Figure 95. Removing Hot Swap Power Supply 9. Disconnect all internal power cables from server system components and from the server board. 88 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 111
    the center divider to the power supply cage. See letter "A" in the following figure. 11. Push the center divider straight back to release tabs from chassis slots. See letter "B". A B TP001400 Figure 96. Detaching Center Divider Intel® Server System SC5400RA User's Guide 89
  • Intel SC5400RA | User Guide - Page 112
    disengage the tabs from chassis wall by pushing center divider up and sideways. See letter "A" in the figure below. 13. Remove the center divider from the power supply cage. See letter "B" in the figure. A B TP001401 Figure 97. Removing Center Divider 90 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 113
    Loosen thumb screw securing the power distribution board to the server system. See letter "A" in the following figure. 15. Lift the power distribution board from the standoffs. See letter "B". B A AF001402 Figure 98. Detaching Power Distribution Board Intel® Server System SC5400RA User's Guide 91
  • Intel SC5400RA | User Guide - Page 114
    below. You may need to feed the power cables through the power supply cage while removing the power distribution board. A AF001403 Figure 99. Removing Power Distribution Board Note: The cables on the back of the power distribution board are not shown. 92 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 115
    replacement power distribution board in through the power supply cage. See letter "A" in the following figure. As you insert the board, route the power cables to the appropriate connection area. A AF001404 Figure 100. Inserting Power Distribution Board Intel® Server System SC5400RA User's Guide 93
  • Intel SC5400RA | User Guide - Page 116
    Board to Power Supply Cage Note: The cables on the back of the power distribution board are not shown. 20. Connect the P1, P14, and P16 cables to the server board. 21. Reconnect power cables to other server system components as appropriate. 94 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 117
    the chassis through the power supply cage. See letter "A" in the figure below. 23. Straighten the center divider and engage it in the clips in the power supply cage. See letter "B" in the figure below. B A TP001429 Figure 102. Re-installing Center Divider Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 118
    Figure 103. Securing Center Divider 25. Insert hot swap power supply(s) into chassis. Replace shipping screw(s) if shipping the system to another location. See letter "A" in the following figure. A AF000603 Figure 104. Installing Hot Swap Power Supply 96 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 119
    Information" on page 129. 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord from the server. 4. Remove the chassis cover. For instructions, see "Removing the Chassis Cover" on page 24. Intel® Server System SC5400RA User's Guide 97
  • Intel SC5400RA | User Guide - Page 120
    lever side of the socketbattery socket, toward the add-in card slots. 10. Install the chassis cover 11. Reconnect the AC power cord and power up the system. 12. Run the BIOS Setup utility to restore the configuration settings to the real-time clock. 98 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 121
    the processor air duct. For instructions, see "Removing the Processor Air Duct" on page 68. 6. Loosen the thumbscrew on the memory riser cage to open the door on the cage. See the figure below. B A Figure 106. Opening Memory Riser Cage AF001406 Intel® Server System SC5400RA User's Guide 99
  • Intel SC5400RA | User Guide - Page 122
    7. Pull the memory riser cards from the memory riser cage. See the figure below. AF001407 Figure 107. Removing Memory Riser Cards 100 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 123
    instructions, see "Removing the Intel® RMM and the Intel® RMM NIC" on page 81. 15. Disconnect all remaining power and data cables from the server board. 16. Remove the eight screws that secure the server board to the chassis. 17. Lift the server board from the chassis. Intel® Server System SC5400RA
  • Intel SC5400RA | User Guide - Page 124
    chassis standoff line up correctly and use caution to make sure you do not pinch any cables. 2. Attach the server board to the system with the eight screws you removed earlier. 3. Install the processor(s). For instructions, see "Installing a Processor 102 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 125
    69. Use caution to make sure you do not pinch any cables. 15. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 16. Plug all peripheral devices and the AC power cable into the server. 17. Power up the server. Intel® Server System SC5400RA User's Guide 103
  • Intel SC5400RA | User Guide - Page 126
    104 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 127
    , the BIOS will load default values for CMOS and attempt to boot. If You Cannot Access Setup If you are not able to access BIOS Setup, you might need to clear the CMOS memory. For instructions on clearing the CMOS, see "Clearing the CMOS" on page 112. Intel® Server System SC5400RA User's Guide 105
  • Intel SC5400RA | User Guide - Page 128
    , the feature's value field is inaccessible. The following table describes the keyboard commands you can use in the BIOS Setup menus. Table 4. Setup Menu Key Use Key to Press Left and right arrows Up arrow whether changes can be discarded. 106 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 129
    system reverts to the BIOS that was in place before the upgrade was performed. This provides a safeguard against problems that might happen during the upgrade, such as a power outage during the upgrade process. This is called the rolling BIOS feature. Intel® Server System SC5400RA User's Guide 107
  • Intel SC5400RA | User Guide - Page 130
    BIOS update process! Note: You may encounter a CMOS Checksum error or other problem after reboot. If this happens, shut down the system and boot it again. CMOS checksum errors require that you enter Setup, check your settings, save your settings, and exit Setup. 108 Intel® Server System SC5400RA
  • Intel SC5400RA | User Guide - Page 131
    , covering pins 2 and 3, to the Bank_0 position, covering pins 1 and 2, as shown by the diagram. BIOS Bank Select 2 3 J1C3 Force Lower Bank Normal Operation (default) AF001426 Figure 110. BIOS Bank Select Jumper in Force Lower Bank Position Intel® Server System SC5400RA User's Guide 109
  • Intel SC5400RA | User Guide - Page 132
    5. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 6. Reconnect the AC power and power up the server system. The BIOS will boot to the previous BIOS until you either move the jumper again or until you perform another BIOS update. Clearing the Password If
  • Intel SC5400RA | User Guide - Page 133
    . 6. Power down the server system. 7. Move the Passwrd Clear jumper back to the original position, covering pins 1 and 2. 8. Install the chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 9. Power up the server system. Intel® Server System SC5400RA User's Guide 111
  • Intel SC5400RA | User Guide - Page 134
    the chassis cover. For instrucstions, see "Removing the Chassis Cover" on page 24. 3. Locate the CMOS Clr jumper block at board position chassis cover. For instructions, see "Installing the Chassis Cover" on page 25. 8. Power up the server system. 112 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 135
    4 Technical Reference Power Cable Routing to Fixed Drives Power Cable Routing Chassis Primary Side View P2 To Upper Device Bay To Server Board To 6-Drive Cage Cable Slot PCI Add-in card retainer detail AF001509 Figure 113. Routing Power Cables to Fixed Drives Power Cable Routing
  • Intel SC5400RA | User Guide - Page 136
    fixed drive and to the appropriate connector on the server board. SATA Cable Routing Chassis Primary Side View SATA Cable SATA Connection to Server Board Chassis Primary Side View To 6-Drive Cage AF001508 Figure 114. Routing SATA Data Cables 114 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 137
    overload the power subsystem and may cause the power supplies to overheat and malfunction. The expansion slots on the server board are rated for no more than 25 Watts for any one slot. The average current usage per slot should not exceed 13 Watts. Intel® Server System SC5400RA User's Guide 115
  • Intel SC5400RA | User Guide - Page 138
    : Operational after an 18" free fall. 5.5 BA LWA idle; 6.3 BA LWA typical operating Electrostatic discharge Tested to 15 kilovolts (kV); no component damage. (ESD) 116 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 139
    Installation/Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only to equipment and shall be easily accessible. SAFETY STEPS: Whenever you remove the chassis covers to access the inside of the system, follow these steps: 1.
  • Intel SC5400RA | User Guide - Page 140
    Also, there may be sharp pins and edges on some board and chassis parts. Contact should be made with care. Consider wearing protective manufacturer. Dispose of used batteries according to manufacturer's instructions. The system is designed to operate in a Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 141
    , um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Server System SC5400RA User's Guide 119
  • Intel SC5400RA | User Guide - Page 142
    . Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. 120 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 143
    ; • "über ausreichend Platz verfügen, um Zugang zu den Netzkabeln zu gewährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Server System SC5400RA User's Guide 121
  • Intel SC5400RA | User Guide - Page 144
    à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 145
    type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. étant le seul moyen de mettre le système hors tension). Intel® Server System SC5400RA User's Guide 123
  • Intel SC5400RA | User Guide - Page 146
    bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 147
    tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Server System SC5400RA User's Guide 125
  • Intel SC5400RA | User Guide - Page 148
    lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 149
    di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Server System SC5400RA User's Guide 127
  • Intel SC5400RA | User Guide - Page 150
    128 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 151
    English Server Safety Information This document applies to Intel® server boards, Intel® server chassis (pedestal server should be integrated and serviced only by technically qualified persons. You must adhere to the guidelines in this guide and the assembly instructions in your server manuals
  • Intel SC5400RA | User Guide - Page 152
    to local occupational health and safety requirements when moving and lifting equipment. • Use mechanical assistance or other suitable assistance when moving and lifting equipment. 130 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 153
    (s) is/are unplugged before you open the chassis, or add or remove any non hot-plug serviceable parts. Do not open the power supply. Hazardous voltage, current and energy levels are present inside the power supply. Return to manufacturer for servicing Intel® Server System SC5400RA User's Guide 131
  • Intel SC5400RA | User Guide - Page 154
    accessible, and it must be labeled as controlling power to the entire unit, not just to the server(s). To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it. 132 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 155
    that cables, add-in boards, and other components are properly installed. • Attach the covers to the chassis according to the product instructions. Laser Peripherals or Devices devices have are not user serviceable • Return to manufacturer for servicing Intel® Server System SC5400RA User's Guide 133
  • Intel SC5400RA | User Guide - Page 156
    hin, der bei Nichtbeachtung der Sicherheitshinweise zu schweren oder tödlichen Verletzungen führen kann. Weist auf Verbrennungsgefahr an heißen Bauteilen bzw. Oberflächen hin. 134 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 157
    und Anheben von Geräten die örtlichen Gesundheits und Sicherheitsvorschriften ein. • Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. Intel® Server System SC5400RA User's Guide 135
  • Intel SC5400RA | User Guide - Page 158
    ab, bevor Sie es aus dem Server ausbauen. Zur Vermeidung von Stromschlägen schalten Sie den Server aus, und trennen Sie vor dem Öffnen des Geräts das Netzkabel sowie alle an den Server angeschlossene Telekommunikationssysteme, Netzwerke und Modems. 136 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 159
    : War Ihr Server in Betrieb, können die installierten Prozessoren und Kühlkörper heiß sein. Sofern Sie keine Hot-Plug-Komponenten ein- oder ausbauen, warten Sie mit dem Abnehmen der Abdeckungen, bis das System abgekühlt ist. Gehen Sie beim Aus- oder Intel® Server System SC5400RA User's Guide 137
  • Intel SC5400RA | User Guide - Page 160
    Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. 138 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 161
    oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Server System SC5400RA User's Guide 139
  • Intel SC5400RA | User Guide - Page 162
    uniquement par des techniciens qualifiés. Vous devez suivre les informations de ce guide et les instructions d'assemblage des manuels de serveur pour vérifier et maintenir la conformité avec pales de ventilateur, car cela peut entraîner des blessures. 140 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 163
    autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. Intel® Server System SC5400RA User's Guide 141
  • Intel SC5400RA | User Guide - Page 164
    Les cordons d'alimentation doivent répondre aux critères suivants : • Le cordon d'alimentation doit supporter une intensité supérieure à celle indiquée sur le produit. • Le cordon d'alimentation des prises électriques correctement reliées à la terre. 142 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 165
    le montage en rack Le rack doit être fixé à un support inamovible pour éviter qu'il ne bascule lors de l'extension d' l'équipement. Le rack doit être installé conformément aux instructions du fabricant. Installez les équipements dans le rack en partant Intel® Server System SC5400RA User's Guide 143
  • Intel SC5400RA | User Guide - Page 166
    système. • Vérifiez que les câbles, les cartes d'extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. 144 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 167
    irse a las directrices de esta guía y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con las certificaciones y homologaciones existentes de los graves si no se tiene en cuenta la ADVERTENCIA. Intel® Server System SC5400RA User's Guide 145
  • Intel SC5400RA | User Guide - Page 168
    conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. 146 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 169
    conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precaució , adquiera alguno cuyo uso esté aprobado en su país. Intel® Server System SC5400RA User's Guide 147
  • Intel SC5400RA | User Guide - Page 170
    el sistema se enfríe antes de abrir las cubiertas. Para que no llegue a tocar los componentes que estén calientes cuando esté realizando una instalación 148 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 171
    se reemplaza correctamente. Al reemplazar la batería, utilice sólo la batería recomendada por el fabricante del equipo. Deseche las baterías respetando la normativa local. Intel® Server System SC5400RA User's Guide 149
  • Intel SC5400RA | User Guide - Page 172
    de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. 150 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 173
    简体中文 Intel Intel Intel Web 注意 警告 Intel® Server System SC5400RA User's Guide 151
  • Intel SC5400RA | User Guide - Page 174
    ITE ITE 场地选择 5V 152 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 175
    Intel® Server System SC5400RA User's Guide 153
  • Intel SC5400RA | User Guide - Page 176
    ESD) ESD ESD ESD ESD 154 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 177
    其他危险 替换电池 Intel® Server System SC5400RA User's Guide 155
  • Intel SC5400RA | User Guide - Page 178
    156 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 179
    adhere to the assembly instructions in this guide to ensure and maintain Intel representative. This is an FCC Class A device. Integration of it into a Class B system does not result in a Class B device. Product Safety Compliance This server chassis product, when correctly integrated per this guide
  • Intel SC5400RA | User Guide - Page 180
    Product Regulatory Compliance References The following table references Server Chassis Compliance and markings that may appear on the product. Markings below ) GB 9254 (Emissions) GB17625 (Harmonics) CANADA ICES-003 CLASS A CANADA NMB-003 CLASSE A 158 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 181
    International CB Certification IEC60950 CISPR 22 / CISPR 24 None Required Japan VCCI Certification Korea RRL Certification MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) Intel® Server System SC5400RA User's Guide 159
  • Intel SC5400RA | User Guide - Page 182
    Russia Ukraine Compliance Reference GOST-R Certification GOST R 2921691 (Emissions) GOST R 5062895 (Immunity) Ukraine Certification Compliance Reference Marking Example None Required Taiwan BSMI CNS13438 R33025 160 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 183
    to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However Intel® Server System SC5400RA User's Guide 161
  • Intel SC5400RA | User Guide - Page 184
    receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. 162 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 185
    area of the product. Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. The following is Intel's product ecology compliance criteria. Intel® Server System SC5400RA User's Guide 163
  • Intel SC5400RA | User Guide - Page 186
    of Regulations, Title 22, Division 4.5; Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material. None Required 164 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 187
    Green Dot Applied to Retail Packaging Only for Boxed Boards Compliance Reference Marking Example None Required. Intel Internal Specification International All materials, parts and subassemblies Applied to Retail Packaging Only for Boxed Boards Intel® Server System SC5400RA User's Guide 165
  • Intel SC5400RA | User Guide - Page 188
    supply cords before servicing. Simplified Chinese 2 Traditional Chinese 2 German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung 166 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 189
    Web address, please contact your local Intel representative. • Server Chassis: (base chassis is provided with power supply and fans) - UL listed. • Server board: you must use an Intel server board - UL recognized. • Add-in boards: must have a printed wiring board flammability rating of minimum UL94V
  • Intel SC5400RA | User Guide - Page 190
    End-of-Life / Product Recycling Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back. 168 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 191
    Wide Web http://support.intel.com/support/motherboards/server/SC5400RA/. Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any
  • Intel SC5400RA | User Guide - Page 192
    8 621 33104691 (not toll-free) Hong Kong 852 2 844 4456 India........... 0006517 2 68303634 (manual toll-free. You need an IDD-equipped telephone) Indonesia ... 803 65 7249 Korea ......... 822 767 2595 800 225 288. Once connected, dial 800 843 4481 170 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 193
    0114 Peru 001 916 377 0114 Uruguay..... 001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Server System SC5400RA User's Guide 171
  • Intel SC5400RA | User Guide - Page 194
    172 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 195
    Warranty for Intel® Server System Subassembly Products Intel warrants that the Products (defined herein as the Intel® chassis subassembly and of any product soldered or otherwise permanently affixed to any printed circuit board. This Limited Warranty, and any implied warranties that may exist under
  • Intel SC5400RA | User Guide - Page 196
    damages due to external causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper installation the applicable law shall be that of the United Kingdom. 174 Intel® Server System SC5400RA User's Guide
  • Intel SC5400RA | User Guide - Page 197
    for the product, please go to the following Web site to obtain instructions: http://support.intel.com/support/ motherboards/draform.htm • In Europe and in Asia Contact your original authorized distributor for warranty service. Any replacement Product is warranted under this written warranty and is
  • Intel SC5400RA | User Guide - Page 198
    176 Intel® Server System SC5400RA User's Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198

Intel
®
Server System SC5400RA User’s
Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/
Products
Intel Order Number D36227-002