Intel SR1530HAHLX User Guide

Intel SR1530HAHLX - Server System - 0 MB RAM Manual

Intel SR1530HAHLX manual content summary:

  • Intel SR1530HAHLX | User Guide - Page 1
    Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX User's Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number D59196-002
  • Intel SR1530HAHLX | User Guide - Page 2
    trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2006, Intel Corporation. All Rights Reserved ii Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX User's Guide
  • Intel SR1530HAHLX | User Guide - Page 3
    in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie
  • Intel SR1530HAHLX | User Guide - Page 4
    http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的 Intel Server Boards and Server Chassis Safety Information(《Intel iv Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX User's Guide
  • Intel SR1530HAHLX | User Guide - Page 5
    jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX User's Guide v
  • Intel SR1530HAHLX | User Guide - Page 6
    vi Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX User's Guide
  • Intel SR1530HAHLX | User Guide - Page 7
    using the Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system. This document provides reference information, feature information, and step by step instructions on
  • Intel SR1530HAHLX | User Guide - Page 8
    with the Intel® Server Board S3000AH. The Intel® Server Systems SR1530AHLX / SR1530HAHLX ship with the Intel® Server Board S3000AHLX. There are three versions of this server system: the Intel® Server System SR1530AHLX, the Intel® Server System SR1530AH, and the Intel® Server System SR1530HAHLX. The
  • Intel SR1530HAHLX | User Guide - Page 9
    the server system - One slimline IDE cable, in the server system product box - One front panel USB cable, installed in the server system - One front panel cable, installed in the server system • Documentation, drivers, and installation CD Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX ix
  • Intel SR1530HAHLX | User Guide - Page 10
    Found at: http://support.intel.com/support/motherboards/server/ S3000AH/ Intel® Server Board S3000AH Technical Product Specification Found at: http://support.intel.com/support/motherboards/server/ S3000AH/ Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX Quick Start User's Guide Found in the
  • Intel SR1530HAHLX | User Guide - Page 11
    9 Internal Components (SR1530AH / SR1530AHLX 11 Internal Components (SR1530HAHLX 12 Server Board Connectors / Components 13 Configuration Jumpers ...15 RAID Support ...16 Hardware Requirements ...16 Processor ...16 Memory ...17 Chapter 2: Server Utilities 19 Using the BIOS Setup Utility 19
  • Intel SR1530HAHLX | User Guide - Page 12
    Processor 37 Installing the Processor 38 Installing the Heat Sink 40 Installing and Removing a Hard Drive (SR1530AH / SR1530AHLX 41 Installing a Hard Disk Drive (SR1530AH/SR1530AHLX 41 Removing a Hard Disk Drive (SR1530AH/SR1530AHLX 45 Installing and Removing a Hot-Swap SATA Drive (SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 13
    Problems with Newly Installed Application Software 108 Problems with Application Software that Ran Correctly Earlier 108 Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System) ...109 Hard Drive(s) are not Recognized 109 Intel® Server System SR1530AH / SR1530AHLX
  • Intel SR1530HAHLX | User Guide - Page 14
    BIOS POST Beep Codes 110 Appendix C: Installation/Assembly Safety Instructions 111 English ...111 Deutsch ...113 Français ...115 Español ...117 Italiano ...120 Appendix D: Safety Information 123 English ...123 Server électrostatiques (ESD 138 xiv Intel® Server System SR1530AH / SR1530AHLX
  • Intel SR1530HAHLX | User Guide - Page 15
    Restriction of Hazardous Substances (RoHS) Compliance 154 End-of-Life / Product Recycling 154 Appendix F: Warranty 155 Limited Warranty for Intel® Chassis Subassembly Products 155 Appendix G: Getting Help 159 World Wide Web ...159 Telephone ...159 Intel® Server System SR1530AH / SR1530AHLX xv
  • Intel SR1530HAHLX | User Guide - Page 16
    xvi Intel® Server System SR1530AH / SR1530AHLX
  • Intel SR1530HAHLX | User Guide - Page 17
    List of Tables Table 1. Server System References x Table 2. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX Feature Summary 2 Table 3. NIC LED Descriptions 7 Table 4. Setup Menu Key Use 20 Table 5. Power Supply Output Capability 99 Table 6. System Environmental Specifications 100 Table
  • Intel SR1530HAHLX | User Guide - Page 18
    xviii Intel® Server System SR1530AH / SR1530AHLX
  • Intel SR1530HAHLX | User Guide - Page 19
    the Drive Carrier (SR1530HAHLX 48 Figure 40. Installing Drive into Drive Carrier (SR1530HAHLX 48 Figure 41. Install Drive Assemby into the Server System (SR1530HAHLX 49 Figure 42. Lifting PCI Cooling Fan from Mounting Pegs (SR1530AH/SR1530AHLX 51 Intel® Server System SR1530AH / SR1530AHLX xix
  • Intel SR1530HAHLX | User Guide - Page 20
    /SR1530AHLX 89 Figure 83. Removing the PCI Cooling Fan (SR1530AH/SR1530AHLX 90 Figure 84. Removing Fan from the Server System (SR1530HAHLX 91 Figure 85. Installing Fan into the Server System (SR1530HAHLX 92 Figure 86. Installing the Rack Handle 93 xx Intel® Server System SR1530AH / SR1530AHLX
  • Intel SR1530HAHLX | User Guide - Page 21
    Figure 87. Removing the Rack Handle 94 Figure 88. Power Cable Routing (SR1530AH / SR1530AHLX 96 Figure 89. Data Cable Routing (SR1530AH / SR1530AHLX 97 Figure 90. Cable Routing (SR1530HAHLX 98 Intel® Server System SR1530AH / SR1530AHLX xxi
  • Intel SR1530HAHLX | User Guide - Page 22
    xxii Intel® Server System SR1530AH / SR1530AHLX
  • Intel SR1530HAHLX | User Guide - Page 23
    showing the location of important components and connections on the server system. Figure 1. Intel® Server System SR1530AH/SR1530AHLX Note: The figure above is shown with an optional optical drive installed. Figure 2. Intel® Server System SR1530HAHLX Note: The figure above is shown with an optional
  • Intel SR1530HAHLX | User Guide - Page 24
    Server System SR1530AH: Intel® Server Board S3000AH • Intel® Server Systems SR1530AHLX / SR1530HAHLX: Intel® Server Board S3000AHLX Support for one: • Dual-Core Intel®Xeon® processor 3000 sequence • Intel® Pentium® processor Extreme Edition • Intel® Pentium® 4 processor • Intel® Pentium® D processor
  • Intel SR1530HAHLX | User Guide - Page 25
    • Power / sleep button • Status LED • Power LED • Hard drive activity LED • NIC1 activity LED • NIC2 activity LED One 350-watt power supply module • Three non-redundant fans (SR1530AH / SR1530AHLX) • Two non-redundant fans (SR1530HAHLX) Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 3
  • Intel SR1530HAHLX | User Guide - Page 26
    Table 2. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX Feature Summary USB Feature System Management Description • One front panel USB port • One internal USB header providing two USB ports Intel® System Management Software 4 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 27
    the following buttons and LEDs. AB C EG DF AF001000 A. USB Port B. Power Button C. Not used D. System Power LED E. Hard Disk Drive Activity LED F. NIC1 LED G. NIC2 LED Figure 3. Front Controls and LEDs (SR1530AH / SR1530AHLX) Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 5
  • Intel SR1530HAHLX | User Guide - Page 28
    Panel (SR1530HAHLX) The front of the server system includes the following buttons and LEDs. B D AC FE AF001573 A. NIC1 LED B. NIC2 LED C. Power LED D. HDD Activity LED E. USB Port F. Power Button Figure 4. Front Controls and LEDs (SR1530HAHLX) 6 Intel® Server System SR1530AH / SR1530AHLX
  • Intel SR1530HAHLX | User Guide - Page 29
    System Rear A B C D E I H GF AF000999 A. AC Power Connector B. Mouse C. Serial Port A D. NIC 1 (10/100/1000 Mb) E. PCI Add-in Card Slot F. Mbps connection (if left LED is on or blinking) 100 Mbps connection 1000 Mbps connection Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 7
  • Intel SR1530HAHLX | User Guide - Page 30
    shows the available options. A B C . AF001074 A. Slimline Optical Drive Bay B. Hard Disk Drive Bay HDD0 (located under the slimline optical drive bay) C. Hard Disk Drive Bay HDD1 Figure 6. Optional Peripherals (SR1530AH / SR1530AHLX) 8 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 31
    ambient temperature of 45C. Note: The Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX do not support all Serial ATA (SATA) hard drives. See "Server System References" on page x for an Internet link to a list of supported hardware. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 9
  • Intel SR1530HAHLX | User Guide - Page 32
    code AXXDVDCDR. Note: The Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX does not support all slimline optical drives. See Table 1 on page x for an Internet link to a list of supported hardware. Intel provides accessory kits for these drives. For installation instructions for an optical
  • Intel SR1530HAHLX | User Guide - Page 33
    in Card Bracket E. Processor and Heat Sink F. Power Supply G. System Memory DIMM Sockets H. System Blower Fans (two) I. Front Panel Board J. Control Panel K. Slimline Optical Drive Bay Figure 8. System Components (SR1530AH / SR1530AHLX) Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 11
  • Intel SR1530HAHLX | User Guide - Page 34
    Blower Fans (two) E. Processor Air Duct F. Server Board G. PCI Add-in Card Bracket H. Processor and Heat Sink I. Power Supply J. Front Panel Board K. Control Panel L. Hard Drive Carriers (three) Figure 9. System Components (SR1530HAHLX) 12 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 35
    LEDs M. Rear System Fan Z. Floppy Connector AA. PATA IDE Connector NN. HSBP Header OO. Intel® 6702 PXH-V Controller N. 2x4 Power Connector BB. SATA Port 3 PP. PCI 32/33 Slot 1 Figure 10. S3000AHLX Connector and Component Locations Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 13
  • Intel SR1530HAHLX | User Guide - Page 36
    . SCSI HDD LED Header GG. SATA Port 1 HH. Clear CMOS Jumper II. SATA Port 0 JJ. BIOS SPI Flash KK. External USB Connector LL. SPI/FWH Select Header MM. HSBP Header NN. PCI 32/33 Slot 1 Figure 11. S3000AH Connector and Component Locations 14 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 37
    be jumpered on 1-2 for normal operation. If pins 2-3 are jumpered, the BIOS in the lower bank will be selected on the next reset. These pins should be jumpered on 1-2 for normal operation. Figure 12. Configuration Jumper Descriptions Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 15
  • Intel SR1530HAHLX | User Guide - Page 38
    RAID Support The Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX provides SATA (3.0 Gb/s) support.The SATA controller embedded in the Intel® Server Board S3000AH / S3000AHLX supports both 1.5 and 3.0 Gbps data transfer rates. The BIOS Setup utility provides multiple drive configuration
  • Intel SR1530HAHLX | User Guide - Page 39
    stacked DIMM modules. In determining your memory requirements, the need for memory sparing or memory mirroring must be considered. For a complete list of supported memory DIMMs, see the links under "Server System References" on page x. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 17
  • Intel SR1530HAHLX | User Guide - Page 40
    18 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 41
    Utility options, which is used to change server configuration defaults. You can run BIOS Setup with or without an operating system being present. See the links under "Server System References" on page x for a link to the Intel® Server Board S3000AH Technical Product Specification where you will find
  • Intel SR1530HAHLX | User Guide - Page 42
    "Setup Menu Key Use" describes the keyboard commands you can use in the BIOS Setup menus. Table 4. Setup Menu Key Use Key to Press Description Pressing they were before was pressed without affecting any existing field values. 20 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 43
    > when you see the message: Press Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip step 2. You will need these settings to configure your server at the end of the procedure. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 21
  • Intel SR1530HAHLX | User Guide - Page 44
    : You may encounter a CMOS Checksum error or other problem after reboot. If this happens, shut down the system and boot it again. CMOS checksum errors require that you enter Setup, check your settings, save your settings, and exit Setup. 22 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 45
    the system begins beeping, power it down and disconnect the AC power. 6. Return the CMOS Clear jumper to the CMOS Clear by BMC location, covering pins 1 and 2. 7. Close the server chassis. 8. Reconnect the AC power and power up the system. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 46
    24 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 47
    in the Intel® Server System SR1530HAHLX are hot swappable and will be noted as such in the instructions that follow where applicable. Note: Most of the illustrations in this chapter show the Intel® Server System SR1530AH / SR1530AHLX with an optional optical drive installed. The instructions for
  • Intel SR1530HAHLX | User Guide - Page 48
    Removing and Installing the Front Bezel The front bezel is available as an optional accessories for the Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX. Note the orientation in the figures below and make sure you position your bezel as shown. Removing the Front Bezel Use the steps below if
  • Intel SR1530HAHLX | User Guide - Page 49
    bezel, line up the center notch on the bezel with the center guide on the rack handles. 2. Push the bezel onto the front of the server system until it clicks into place. 3. Lock the bezel. Figure 15. Installing the Front Bezel AF001058 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 27
  • Intel SR1530HAHLX | User Guide - Page 50
    rearward on the blue grip point at the front of the server. Slide the cover back until it stops and then lift the cover upward to remove it. See letter "C". B C A AF000662 Figure 16. Removing the Server System Cover (SR1530AH/SR1530AHLX) 28 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 51
    : Push rearward on the blue grip point at the front of the server. Slide the cover back until it stops and then lift the cover upward to remove it. See letter "B". B A AF001578 Figure 17. Removing the Server System Cover (SR1530HAHLX) Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 29
  • Intel SR1530HAHLX | User Guide - Page 52
    over the server system so that the side edges of the cover sit just inside the server system sidewalls. Slide the cover forward. See letter "A" in the figure below. 6. SR1530HAHLX: Install the four screws at the front of the server. See letter "B". 30 Intel® Server System SR1530AH / SR1530AHLX
  • Intel SR1530HAHLX | User Guide - Page 53
    3. Remove the server system cover. For instructions, see "Removing the Server System Cover". 4. Lift the processor air duct from its location behind the two system blower fans (see Figure 20 for SR1530AH/SR1530AHLX; see for SR1530HAHLX). Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 31
  • Intel SR1530HAHLX | User Guide - Page 54
    AF000664 Figure 20. Removing the Processor Air Duct (SR1530AH/SR1530AHLX) AF001580 Figure 21. Removing the Processor Air Duct (SR1530HAHLX) 32 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 55
    pinch or disengage cables that may be near or under the air duct. 5. Install the server system cover. For instructions, see "Installing the Server System Cover". AF000665 Figure 22. Installing the Processor Air Duct (SR1530AH/SR1530AHLX) Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 33
  • Intel SR1530HAHLX | User Guide - Page 56
    Figure 23. Installing the Processor Air Duct (SR1530HAHLX) Installing and Removing Memory Caution: The memory is NOT hot swappable. Before removing or replacing any memory DIMM, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the
  • Intel SR1530HAHLX | User Guide - Page 57
    A B DIMM 1A Socket DIMM 2A Socket Figure 24. Installing the Memory DIMM 2B Socket DIMM 1B Socket AF000534 5. Make sure the clips at . 11. Install the server system cover. For instructions, see "Installing the Server System Cover". Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 35
  • Intel SR1530HAHLX | User Guide - Page 58
    lifts from the socket. 6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. 7. Install the server system cover. For instructions, see "Installing the Server System Cover". 36 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 59
    plate. 9. Remove the processor. 10. If installing a replacement processor, see "Installing the Processor" on page 38. Otherwise, install the protective socket cover over the empty processor socket and then reinstall the chassis cover. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 37
  • Intel SR1530HAHLX | User Guide - Page 60
    the front of the load plate. Raise the load plate completely. Raise the CPU load plate (see Figure 26). A B Figure 26. Opening the Load Plate AF000529 Caution: Do not touch the socket pins; they are very sensitive and easily damaged. 38 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 61
    the protective socket cover. See Figure 29. A B AF000530 Figure 29. Removing the Protective Socket Cover Note: Retain the protective socket cover for use when removing a processor that will not be replaced. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 39
  • Intel SR1530HAHLX | User Guide - Page 62
    and equally tighten each captive screw in the same order until each is firmly tightened. AIRFLOW 3 2 1 4 FCrohnatssis AF001049 Figure 30. Installing the Heat Sink 40 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 63
    reconnect any parts you removed or disconnected to reach the processor sockets. 7. Install the server system cover. For instructions, see "Installing the Server System Cover". Installing and Removing a Hard Drive (SR1530AH / SR1530AHLX) Caution: The hard drives are NOT hot swappable. Before removing
  • Intel SR1530HAHLX | User Guide - Page 64
    You will use it to reinstall the drive assembly later. 7. Lift the drive carrier from the chassis. See letter "B" in the figure. A B ChFarsosnist AF001050 Figure 32. Removing Drive Carrier from the Server System (SR1530AH/ SR1530AHLX) 42 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 65
    in the figure below. Note: The assembly that contains the optical drive bracket must be installed at the left side of the system. B A HDD 0 HDD 1 AF000667 Figure 34. Install Drive Assembly into the Server System (SR1530AH/ SR1530AHLX) Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 43
  • Intel SR1530HAHLX | User Guide - Page 66
    "D" in Figure 35. BC 1 0 HDD 0 B D CE A HDD 1 AF001173 Figure 35. Connecting Hard Drive Power and Data Cables (SR1530AH/ SR1530AHLX) 16. Install the server system cover. For instructions, see "Installing the Server System Cover". 44 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 67
    rest of these steps and instead see "Installing a Hard Disk Drive (SR1530AH/SR1530AHLX)" on page 41, beginning with step 8. 10. Insert the screws that held the drive in the carrier into the screw locations on the carrier for future use. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 45
  • Intel SR1530HAHLX | User Guide - Page 68
    at the left side of the system. B A HDD 0 HDD 1 AF000667 Figure 37. Install Drive Carrier into the Server System (SR1530AH/ SR1530AHLX) 13. Install the server system cover. For instructions, see "Installing the Server System Cover". 46 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 69
    Drive (SR1530HAHLX) 1. Remove the front bezel if it is installed. For instructions, see "Removing the Front Bezel". 2. Locate the drive position you want to use. See Figure 38. HDD 0 HDD 1 HDD 2 AF001582 Figure 38. Locating Drive Positions (SR1530HAHLX) Intel® Server System SR1530AH / SR1530AHLX
  • Intel SR1530HAHLX | User Guide - Page 70
    to the holes in the drive carrier and attach it to the carrier with the screws that were attached to the plastic retention device. See letter "B" in Figure 40. A B AF001584 Figure 40. Installing Drive into Drive Carrier (SR1530HAHLX) 48 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 71
    carrier for future use. 7. With the black lever in the fully open position, slide the drive carrier into the server system. The green latch must be to the right. Do not push on the black lever until the lever begins to close by itself. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 49
  • Intel SR1530HAHLX | User Guide - Page 72
    or Removing a Slimline Optical Drive (SR1530AH / SR1530AHLX) Caution: The optical drive is NOT hot swappable. Before removing or replacing the optical drive, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the
  • Intel SR1530HAHLX | User Guide - Page 73
    Figure 42. Lifting PCI Cooling Fan from Mounting Pegs (SR1530AH/ SR1530AHLX) 6. First time installation only: Remove the knock-out by rocking rear of the CD-ROM or DVD-ROM drive, using two screws, as shown by the following figure. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 51
  • Intel SR1530HAHLX | User Guide - Page 74
    you removed in step 6. 11. A daisy chain cable is used for the hard disk drives and the optical drive. Connect the end connector on the daisy chain cable to the power connector on the optical drive. See letter "C" in the figure below. 52 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 75
    bezel. For instructions, see "Installing the Front Bezel" on page 27. 15. Install the server system cover. For instructions, see "Installing the Server System Cover". 16. Plug all peripheral devices and the AC power cable into the server. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 53
  • Intel SR1530HAHLX | User Guide - Page 76
    that holds the optical drive bracket to the server chassis. See letter "C" in the figure below. Save this screw. You will reinstall it later. 8. Slide the optical drive out through the front of the system. See letter "D" in the figure. 54 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 77
    -ROM or DVD-ROM drive to detach the interposer board. See letter "A" in the figure below. 11. Carefully pull the interposer board from the drive, detaching the interposer board connector from the drive. See letter "B" in the figure below. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 55
  • Intel SR1530HAHLX | User Guide - Page 78
    PCI Cooling Fan (SR1530AH/SR1530AHLX) 15. Optional: Install the front bezel. For instructions, see "Installing the Front Bezel" on page 27. 16. Install the server system cover. For instructions, see "Installing the Server System Cover". 56 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 79
    or Removing a Slimline Optical Drive (SR1530HAHLX) Caution: The optical drive is NOT hot swappable. Before removing or replacing the optical drive, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button
  • Intel SR1530HAHLX | User Guide - Page 80
    the Front Bezel" on page 26. 5. Remove the screws holding the drive in place (see letters "A" and "B" in the figure below) and slide the optical drive assembly out through the front of the chassis (see letter "C" in the figure below). 58 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 81
    Optical Drive from the Attachment Bracket 7. 8. Optional: Install the front bezel. For instructions, see "Installing the Front Bezel" on page 27. 9. Install the server system cover. For instructions, see "Installing the Server System Cover". Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 82
    damage the slot or the riser card. See Figure 57. AF000673 Figure 57. Removing PCI Riser Assembly from the Server System 6. If you need to add or replace a PCI riser connector, see "Installing or Replacing a PCI Riser Card" on page 62. 60 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 83
    . 4. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. 5. Install the server system cover. For instructions, see "Installing the Server System Cover". Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 61
  • Intel SR1530HAHLX | User Guide - Page 84
    is NOT hot swappable. Before removing or replacing the PCI riser card, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by Removing Riser Card from Riser Assembly 62 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 85
    into the server system. For instructions, see "Installing the PCI Riser Assembly" on page 61. 10. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 63
  • Intel SR1530HAHLX | User Guide - Page 86
    devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 28. 4. Remove the PCI riser assembly. For instructions, see "Removing the PCI Riser Assembly" on page 60. 64 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 87
    devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 28. 4. Remove the PCI riser assembly. For instructions, see "Removing the PCI Riser Assembly" on page 60. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 65
  • Intel SR1530HAHLX | User Guide - Page 88
    For instructions, see "Installing the Processor Air Duct" on page 33. 11. Install the server system cover. For instructions, see "Installing the Server System Cover". 12. Plug all peripheral devices and the AC power cable into the server. 66 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 89
    Detach all cables connected to the server board. 7. Remove the heat sink and the processor. For instructions, see "Removing the Heat Sink and Processor" on page 37. 8. Remove the DIMMs. For instructions, see "Removing DIMMs" on page 36. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 67
  • Intel SR1530HAHLX | User Guide - Page 90
    For instructions, see "Installing the Processor Air Duct" on page 33. 16. Install the server system cover. For instructions, see "Installing the Server System Cover". 17. Plug all peripheral devices and the AC power cable into the server. 68 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 91
    " on page 60. 6. Place the server board into the server system as shown by letter "A" in the figure below. 7. Attach the server board with nine screws. See letter "B" in the figure. B A Figure 64. Installing the Server Board AF000678 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 69
  • Intel SR1530HAHLX | User Guide - Page 92
    "Installing the Processor Air Duct" on page 33. 14. Install the server system cover. For instructions, see "Installing the Server System Cover". 15. Plug all peripheral devices and the AC power cable into the server. Replacing the CMOS Battery Caution: The CMOS battery is NOT hot swappable. Before
  • Intel SR1530HAHLX | User Guide - Page 93
    lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run the BIOS Setup utility to restore the configuration settings. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 71
  • Intel SR1530HAHLX | User Guide - Page 94
    B: 2x12 main power connector - C: Daisy-chain cable to: ✧ Optical drive power connector, if an optical drive is installed ✧ HDD0 power connector, if a hard drive is installed here ✧ HDD1 power connector, if a hard drive is installed here 72 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 95
    . A B C AF000969 Figure 66. Disconnecting Power Cables (SR1530AH / SR1530AHLX) Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 73
  • Intel SR1530HAHLX | User Guide - Page 96
    5. Remove the screw at the back of the server system, next to the AC power input. Save this screw. You will re- then lift it from the chassis. A B C B AF000965 Figure 67. Removing Power Supply from the Server System (SR1530AH / SR1530AHLX) 74 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 97
    "B" in the figure. 10. Insert the screw you removed in step 5 to attach the power supply to the server system. See letter "C". C B A B AF000966 Figure 68. Installing Power Supply Module into the Server System (SR1530AH / SR1530AHLX) Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 75
  • Intel SR1530HAHLX | User Guide - Page 98
    AF000969 Figure 69. Connecting Power Cables (SR1530AH / SR1530AHLX) 12. Install the server system cover. For instructions, see "Installing the Server System Cover". 13. Plug all peripheral devices and the AC power cable into the server. 76 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 99
    Replacing the Power Supply (SR1530HAHLX) Caution: The power supply is NOT hot swappable. Before removing or replacing the power supply, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug
  • Intel SR1530HAHLX | User Guide - Page 100
    server board and peripherals. 10. Install the server system cover. For instructions, see "Installing the Server System Cover". 11. Plug all peripheral devices and the AC power cable into the server (see letter "C" in the figure above). 78 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 101
    the Front Panel Board (SR1530AH/ SR1530AHLX) Caution: The control panel is NOT hot swappable. Before removing or replacing the control panel, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and
  • Intel SR1530HAHLX | User Guide - Page 102
    Front Panel Board into the Server System (SR1530AH/ SR1530AHLX) 13. Install the server system cover. For instructions, see "Installing the Server System Cover". 14. Plug all peripheral devices and the AC power cable into the server. 80 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 103
    Replacing the Front Panel Board (SR1530HAHLX) Caution: The control panel is NOT hot swappable. Before removing or replacing the control panel, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and
  • Intel SR1530HAHLX | User Guide - Page 104
    in the figure below). 9. Use the screw you removed in step 5 to attach the front panel board to the system (see letter "C" in the figure below). C B A AF001590 Figure 76. Installing Front Panel Board into the Server System (SR1530HAHLX) 82 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 105
    cable if you removed it in step 4. 12. Connect the front panel cable. 13. Install the server system cover. For instructions, see "Installing the Server System Cover". 14. Plug all peripheral devices and the AC power cable into the server. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 83
  • Intel SR1530HAHLX | User Guide - Page 106
    "Removing the Server System Cover". 4. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct" on page 31 5. Disconnect the two fan cables from the server board. See letters "A" and "B" in the figure below. 84 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 107
    beneath the clip at the front of the fan bracket. See letter "B" from the figure. 8. Lift the fan bracket from the server. Lift the bracket at an angle, front of the bracket first, to clear the hard disk drive brackets. See letter "C". Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 85
  • Intel SR1530HAHLX | User Guide - Page 108
    A B C AF000961 Figure 79. Removing Bracket and System Blower Fans from Server System (SR1530AH / SR1530AHLX) 86 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 109
    Set the fan assembly into the system. Insert the rear edge first and push the assembly slightly rearward to clear the hard disk drive brackets. Use caution to make sure to the server board. See letters "A" and "B" in the following figure. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 87
  • Intel SR1530HAHLX | User Guide - Page 110
    AB A B AF001175 Figure 81. Connecting System Blower Fans (SR1530AH / SR1530AHLX) 15. Install the processor air duct. For instructions. see "Installing the Processor Air Duct" on page 33. 88 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 111
    the PCI Cooling Fan (SR1530AH/SR1530AHLX) Caution: The PCI cooling fan is NOT hot swappable. Before removing or replacing the PCI cooling fan, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button
  • Intel SR1530HAHLX | User Guide - Page 112
    Connect the fan cable to the server board. See letter "A" in Figure 82. 8. Install the server system cover. For instructions, see "Installing the Server System Cover". 9. Plug all peripheral devices and the AC power cable into the server. 90 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 113
    Fan (SR1530HAHLX) Caution: The fans are NOT hot swappable. Before removing or replacing a fan, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or
  • Intel SR1530HAHLX | User Guide - Page 114
    Figure 85. Installing Fan into the Server System (SR1530HAHLX) 12. Install the server system cover. For instructions, see "Installing the Server System Cover". 13. Plug all peripheral devices and the AC power cable into the server. 92 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 115
    5. Repeat step 4 on the opposite side of the server. 6. Optional: Install the front bezel, if desired. For instructions, see "Installing the Front Bezel" on page 27. 7. Plug all peripheral devices and the AC power cable into the server. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 93
  • Intel SR1530HAHLX | User Guide - Page 116
    5. Repeat step 4 on the opposite side of the system. 6. Optional: Install the front bezel, if desired. For instructions, see "Installing the Front Bezel" on page 27. 7. Plug all peripheral devices and the AC power cable into the server. 94 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 117
    Appendix A: Technical Reference Cable Routing When you add or remove components from your server system, make sure your cables are routed correctly before reinstalling the server system cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked.
  • Intel SR1530HAHLX | User Guide - Page 118
    hard drives and the optical drive is a single daisy chain cable. To make the diagram above more clear, where the connectors attach to components, the labels "F1", "F2", and "F3" are used. The end at the power supply itself is labeled "F" 96 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 119
    Routing (SR1530AH / SR1530AHLX) A B C D E E Optical Device HDD 0 C AD B HDD 1 AF001206 A. Front panel USB B. SATA 0 to HDD0 C. SATA 1 to HDD1 D. Front panel E. Optical drive Figure 89. Data Cable Routing (SR1530AH / SR1530AHLX) Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 97
  • Intel SR1530HAHLX | User Guide - Page 120
    F Optical Device Data Cable G Optical Device Power H Blower Fan #1 Power I Blower Fan #2 Power J HDD 0 to Server Board SATA 0 K HDD 1 to Server Board SATA 1 L HDD 2 to Server Board SATA 2 Figure 90. Cable Routing (SR1530HAHLX) AF001632 98 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 121
    90 Watts for the +5 V and +3.3 V outputs. Exceeding a combined 90 Watts will overload the power subsystem and may cause the power supplies to overheat and malfunction. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 99
  • Intel SR1530HAHLX | User Guide - Page 122
    Environmental Specifications Table 6. System Environmental Specifications Temperature Non-operating Operating Humidity Non-operating Shock Operating Packaged Acoustic noise noise level. Tested to 15 kilovolts (kV); no component damage. 100 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 123
    , such as video drivers, network drivers, and SATA drivers. Intel provides a package called the "Platform Confidence Test" that may help with your diagnostics. See "Server System References" on page x for a link to this software. If you are unable to resolve your server problems on your own, see
  • Intel SR1530HAHLX | User Guide - Page 124
    components from the tested components lists? Check the tested memory, and chassis lists, as well as the supported hardware and operating system list. See "Server System References" on page x for links to the tested component lists. 102 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 125
    appear, see "No Characters Appear on Screen" on page 104. Specific Problems and Corrective Actions This section provides possible solutions for these specific problems: • Power light does not light. • No characters appear on screen. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 103
  • Intel SR1530HAHLX | User Guide - Page 126
    on the bottom of the server board and cause a short. No Characters Appear on Screen Check the following: • Is the keyboard functioning? Test it by turning the "Num Lock" function on and off to make sure the Num Lock light is functioning. 104 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 127
    ? • Does this video monitor work correctly if plugged into a different system? System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, it is an indication of possible system component failure. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 105
  • Intel SR1530HAHLX | User Guide - Page 128
    attached to the correct connector at the system back panel. • Try a different network cable. • Make sure you are using the correct and the current drivers. See "Server System References" on page x for a link to the current drivers. 106 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 129
    . • Try reseating the add-in adapter. The add-in adapter stopped working without apparent cause • Reseat the adater. • The network driver files may be corrupt or deleted. Delete and then reinstall the drivers. • Run diagnostics. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 107
  • Intel SR1530HAHLX | User Guide - Page 130
    drivers installed. If the problems persist, contact the software vendor's customer service representative. Problems with Application Software that Ran Correctly Earlier Problems that occur after the system . Symptoms of voltage spikes 108 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 131
    configuration with SCSI or SATA drives, make sure the RAID card is installed correctly. Bootable CD-ROM Disk Is Not Detected Check the following: • Make sure the BIOS is configured to allow the CD-ROM to be the first bootable device. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 109
  • Intel SR1530HAHLX | User Guide - Page 132
    LED Information The Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX includes LEDs that can aid in troubleshooting your system. A table of these LEDs with a description of their use is listed below. Table 8. LED Information LED Name Power Function Location Indicates system power Front
  • Intel SR1530HAHLX | User Guide - Page 133
    Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 134
    system. A microprocessor and heat sink may be hot if the system has been running. Also, there may be sharp pins and edges on some board and chassis parts batteries according to manufacturer's instructions. The system is designed to operate in Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 135
    Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 113
  • Intel SR1530HAHLX | User Guide - Page 136
    : 1. Vergewissern Sie sich, daß Sie keine Werkzeuge oder Teile im Innern des Systems zurückgelassen haben. 2. Überprüfen Sie alle Kabel, Zusatzkarten und andere Komponenten Batterien den Anweisungen des Herstellers entsprechend. 114 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 137
    Français Das System wurde für den Betrieb in einer normalen Büroumgebung entwickelt. Der Standort sollte: • "sauber und staubfrei sein ( mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 115
  • Intel SR1530HAHLX | User Guide - Page 138
    a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. 116 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 139
    type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. ón de corriente alterna que tenga el producto Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 117
  • Intel SR1530HAHLX | User Guide - Page 140
    las tapas del sistema. Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos externos y los cables de alimentación CA al sistema. 118 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 141
    para funcionar en un entorno de trabajo normal. Escoja un lugar: • "Limpio y libre de partículas en suspensión (salvo el polvo normal). • "Bien ventilado y alejado de fuentes de calor hacen de medio principal de desconexión del sistema. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 119
  • Intel SR1530HAHLX | User Guide - Page 142
    lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 143
    Scegliere una postazione che sia: • "Pulita e libera da particelle in sospensione (a parte la normale polvere presente nell'ambiente). • "Ben ventilata e lontana da fonti di calore il mezzo principale di scollegamento del sistema. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 121
  • Intel SR1530HAHLX | User Guide - Page 144
    122 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 145
    if the WARNING is ignored. Indicates potential hazard if indicated information is ignored. Indicates shock hazards that result in serious injury or death if safety instructions are not followed. Indicates hot components or surfaces. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 123
  • Intel SR1530HAHLX | User Guide - Page 146
    regions that are susceptible to electrical storms, we recommend you plug your system into a surge suppresser and disconnect telecommunication lines to your modem during an for easier handling, remove any easily detachable components. 124 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 147
    serviceable parts. Do not open the power supply. Hazardous voltage, current and energy levels are present inside the power supply. Return to manufacturer for servicing. When replacing a hot is /are provided with a suitable earth ground. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 125
  • Intel SR1530HAHLX | User Guide - Page 148
    , and it must be labeled as controlling power to the entire unit, not just to the server(s). To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it. 126 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 149
    parts inside the system. • Check that cables, add-in boards, and other components are properly installed. • Attach the covers to the chassis according to the product instructions not user serviceable • Return to manufacturer for servicing Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 127
  • Intel SR1530HAHLX | User Guide - Page 150
    hin, der bei Nichtbeachtung der Sicherheitshinweise zu schweren oder tödlichen Verletzungen führen kann. Weist auf Verbrennungsgefahr an heißen Bauteilen bzw. Oberflächen hin. 128 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 151
    äte erzeugt werden. • In gewittergefährdeten Gebieten sollten Sie das System an einen Überspannungsschutz anschließen und bei einem Gewitter die Telekommunikationskabel , um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 129
  • Intel SR1530HAHLX | User Guide - Page 152
    Sie ein hot-plug-fähiges Netzteil austauschen, ziehen Sie dessen Netzkabel ab, bevor Sie es aus dem Server ausbauen. Zur Vermeidung von Stromschlägen schalten Sie den Server aus, und ordnungsgemäß geerdete Steckdose angeschlossen sein. 130 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 153
    . • Schalten Sie den Server aus, und ziehen Sie alle Netzkabel ab, bevor Sie Komponenten ein- oder ausbauen, die nicht hot-plug-fähig sind. • Wenn Sie ein hot-plug-fähiges Netzteil austauschen, immer nur ein Gerät aus dem Rack heraus. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 131
  • Intel SR1530HAHLX | User Guide - Page 154
    . Die Inbetriebnahme des Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen Sie die Abdeckung wieder an: • Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben. 132 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 155
    uniquement par des techniciens qualifiés. Vous devez suivre les informations de ce guide et les instructions d'assemblage des manuels de serveur pour vérifier et maintenir la conformit peuvent figurer sur le produit ou sur son emballage. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 133
  • Intel SR1530HAHLX | User Guide - Page 156
    soleil et les radiateurs. • À l'écart des sources de vibration ou des chocs physiques. • Isolé des champs électromagnétiques importants produits par des appareils électriques. 134 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 157
    ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage . L'intérieur de celui-ci est soumis à des Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 135
  • Intel SR1530HAHLX | User Guide - Page 158
    Les cordons d'alimentation doivent répondre aux critères suivants : - Le cordon d'alimentation doit supporter une intensité supérieure à celle indiquée sur le produit. - Le cordon d'alimentation qui sont connectés au système. 136 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 159
    montage en rack Le rack doit être fixé à un support inamovible pour éviter qu'il ne bascule lors de l'extension quipement. Le rack doit être installé conformément aux instructions du fabricant. Installez les équipements dans le rack en Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 137
  • Intel SR1530HAHLX | User Guide - Page 160
    système. • Vérifiez que les câbles, les cartes d'extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. 138 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 161
    irse a las directrices de esta guía y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con las certificaciones y homologaciones existentes de si no se tiene en cuenta la ADVERTENCIA. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 139
  • Intel SR1530HAHLX | User Guide - Page 162
    conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. 140 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 163
    conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use alguno cuyo uso esté aprobado en su país. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 141
  • Intel SR1530HAHLX | User Guide - Page 164
    para repararla. • Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que no es de conexión en funcionamiento. 142 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 165
    los componentes que estén calientes cuando esté realizando una instalación de conexión en funcionamiento, tenga cuidado al extraer o instalar los componentes de conexión en funcionamiento. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 143
  • Intel SR1530HAHLX | User Guide - Page 166
    del bastidor. Instale el equipo en el bastidor comenzando desde la parte de abajo, con el equipo más pesado en la parte inferior del bastidor. Extraiga las piezas del equipo del bastidor de de tierra y sin carga estática. Utilice una 144 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 167
    caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 145
  • Intel SR1530HAHLX | User Guide - Page 168
    146 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 169
    adhere to the assembly instructions in this guide to ensure and maintain Intel representative. This is an FCC Class A device. Integration of it into a Class B system does not result in a Class B device. Product Safety Compliance This server system product, when correctly integrated per this guide
  • Intel SR1530HAHLX | User Guide - Page 170
    License (Ukraine) • RRL MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) (Korea) • GB 9254 - CNCA Certification (China) • GB 17625 - (Harmonics) CNCA Certification (China) 148 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 171
    ) • Ecology Declaration (International) Product Regulatory Compliance Markings This Intel® server system product is provided with the following regulatory marks. Table 10. Europe FCC Marking (Class A) USA EMC Marking (Class A) Canada Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 149
  • Intel SR1530HAHLX | User Guide - Page 172
    Zealand Marking VCCI Marking (Class A) Japan BSMI Certification Number & Class A Warning Taiwan GOST R Marking RRL MIC Mark Russia Korea China Compulsory Certification Mark China 150 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 173
    performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Class A digital device, pursuant to Part 15 of the FCC Rules. These limits used in accordance with the instructions, may cause harmful interference Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 151
  • Intel SR1530HAHLX | User Guide - Page 174
    a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. 152 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 175
    have access to Intel's Web address, please contact your local Intel representative. • Server Chassis: (base chassis is provided with power supply and fans) - UL listed. • Server board: you must use an Intel server board - UL recognized. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 153
  • Intel SR1530HAHLX | User Guide - Page 176
    Cadmium End-of-Life / Product Recycling Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back. 154 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 177
    publicly available specifications for a period of three (3) years after the date the Product was purchased from an Intel authorized distributor. Software of any kind delivered with or as part of products is expressly provided "as is" unless specifically provided for otherwise in any software license
  • Intel SR1530HAHLX | User Guide - Page 178
    due to external causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper Limited Warranty, the English language version shall control. 156 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 179
    .intel.com/), call your local distributor or an Intel Customer Support representative. See "Getting Help" for telephone numbers. Returning a Defective Product Before returning any product, call your authorized dealer/distribution authority. Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 180
    158 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 181
    reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out an Intel® Server Issue Report Form. A sample form can be found at http://support.intel.com/support/motherboards/server/s3000ah. For the fastest service, please submit your form via
  • Intel SR1530HAHLX | User Guide - Page 182
    621 33104691 (not toll-free) Hong Kong 852 2 844 4456 India........... 0006517 2 68303634 (manual toll-free. You need an IDD-equipped telephone) Indonesia ... 803 65 7249 Korea ......... 822 767 225 288. Once connected, dial 800 843 4481 160 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • Intel SR1530HAHLX | User Guide - Page 183
    0114 Peru 001 916 377 0114 Uruguay..... 001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX 161
  • Intel SR1530HAHLX | User Guide - Page 184
    162 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184

Intel
®
Server System SR1530AH /
SR1530AHLX / SR1530HAHLX
User’s Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/