Intel SR1530HSH User Guide

Intel SR1530HSH - Server System - 0 MB RAM Manual

Intel SR1530HSH manual content summary:

  • Intel SR1530HSH | User Guide - Page 1
    Intel® Server System SR1530SH/ SR1530HSH User's Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number E12554-008
  • Intel SR1530HSH | User Guide - Page 2
    or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2007-2011, Intel Corporation. All Rights Reserved ii Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 3
    documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel® Server Deployment Toolkit CD y/o en http://www.intel.com/ support/motherboards/server/sb/CS-010770.htm. Intel® Server System SR1530SH/SR1530HSH User's Guide iii
  • Intel SR1530HSH | User Guide - Page 4
    http://www.intel.com/support/motherboards/server/sb/CS-010770.htm 上的 Intel Server Boards and Server Chassis Safety Information(《Intel iv Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 5
    inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Server System SR1530SH/SR1530HSH User's Guide v
  • Intel SR1530HSH | User Guide - Page 6
    vi Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 7
    fans, power supply, drives, and other components. At the back of this manual, you will find technical specifications, troubleshooting tips, regulatory information, complete safety information, "getting help" information, and the warranty. Intel® Server System SR1530SH/SR1530HSH User's Guide vii
  • Intel SR1530HSH | User Guide - Page 8
    SR1530SH and the Intel® Server System SR1530HSH. The contents of each server system are listed below. Intel® Server System SR1530SH Contents Your Intel® Server System SR1530SH ships with the following items: • One Intel® Server Board S3200SHL installed in the server system • One 350-W power supply
  • Intel SR1530HSH | User Guide - Page 9
    in a separate box • Cables: - Three SATA cables, installed in the server system - One front panel USB cable, installed in the server system - One front panel cable, installed in the server system • Documentation, drivers, and installation CD Intel® Server System SR1530SH/SR1530HSH User's Guide ix
  • Intel SR1530HSH | User Guide - Page 10
    Technical Product Specification http://www.intel.com/p/en_US/support/highlights/server/s3200sh Intel® Server Board S3200SH/S3210SH Technical Product Specification http://www.intel.com/p/en_US/support/highlights/server/s3200sh Intel® Server System SR1530SH/SR1530HSH Quick Start User's Guide You can
  • Intel SR1530HSH | User Guide - Page 11
    Processor ...14 Memory ...14 Chapter 2: Server Utilities 15 Using the BIOS Setup Utility 15 Starting Setup ...15 If You Cannot Access Setup 15 Setup Menus ...15 Upgrading the BIOS ...17 Preparing for the Upgrade 17 Upgrading the BIOS ...18 Intel® Server System SR1530SH / SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 12
    Replacing a PCIe* Riser Card 57 Removing a PCIe* Riser Card 57 Installing a PCIe* Riser Card 58 Installing and Removing a PCI Add-in Card 59 Installing a PCI Add-in Card 59 Removing a PCI Add-in Card 60 Replacing the Server Board 62 xii Intel® Server System SR1530SH / SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 13
    ...87 Power Cable Routing (SR1530SH 88 Data Cable Routing (SR1530SH 89 Cable Routing (SR1530HSH 90 350-W Single Power Supply Input Voltages 91 350-W Single Power Supply Output Voltages 91 System Environmental Specifications 92 Appendix B: Troubleshooting 93 Resetting the System ...93 Problems
  • Intel SR1530HSH | User Guide - Page 14
    Bootable CD-ROM Disk Is Not Detected 101 LED Information ...102 BIOS POST Beep Codes 102 Appendix C: Installation/Assembly Safety Instructions 103 English ...103 Deutsch ...105 Français 128 Avertissements sur le montage en rack 129 xiv Intel® Server System SR1530SH / SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 15
    Compatibility Notices 147 FCC Verification Statement (USA 147 Industry Canada (ICES-003 148 Europe (CE Declaration of Conformity Intel® Chassis Subassembly Products 151 Appendix G: Getting Help 155 World Wide Web ...155 Telephone ...155 Intel® Server System SR1530SH / SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 16
    xvi Intel® Server System SR1530SH / SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 17
    1. Intel® Server System SR1530SH 1 Figure 2. Intel® Server System SR1530HSH 2 Figure 3. Front Controls and LEDs (SR1530SH 5 Figure 4. Front Controls and LEDs (SR1530HSH 6 Figure 5. Back Panel Connectors 7 Figure 6. System Components (SR1530SH 10 Figure 7. System Components (SR1530HSH 11
  • Intel SR1530HSH | User Guide - Page 18
    Server System (SR1530HSH 84 Figure 78. Installing the Rack Handle 85 Figure 79. Removing the Rack Handle 86 Figure 80. Power Cable Routing (SR1530SH 88 Figure 81. Data Cable Routing (SR1530SH 89 Figure 82. Cable Routing (SR1530HSH 90 xviii Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 19
    6. Power Supply Output Capability 91 Table 7. System Environmental Specifications 92 Table 8. Resetting the System 93 Table 9. LED Information ...102 Table 10. POST Error Beep Codes 102 Table 11. Product Regulatory Compliance Markings 145 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 20
    xx Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 21
    , a list of the server system features, and diagrams showing the location of important components and connections on the server system. Figure 1. Intel® Server System SR1530SH Note: Figure 1 is shown with an optional optical drive installed. Intel® Server System SR1530SH/SR1530HSH User's Guide 1
  • Intel SR1530HSH | User Guide - Page 22
    Figure 2. Intel® Server System SR1530HSH Note: Figure 2 is shown with an optional optical drive installed. 2 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 23
    Table 2 summarizes the features of the server system. Table 2. Intel® Server System SR1530SH / SR1530HSH Feature Summary Feature Dimensions (S1530SH) Dimensions (SR1530HSH) Server Board Processor Memory Chipset Peripheral Interfaces I/O Control Video LAN Description • 1.69 inches high (4.29
  • Intel SR1530HSH | User Guide - Page 24
    button • Status LED • Power LED • Hard drive activity LED • NIC1 activity LED • NIC2 activity LED One 350-watt power supply module • Three non-redundant fans (SR1530SH) • Two non-redundant fans (SR1530HSH) Intel® System Management Software 4 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 25
    system includes the following buttons and LEDs. AB C EG DF AF001000 A. USB Port B. Power Button C. System Status LED D. System Power LED E. Hard Disk Drive Activity LED F. NIC1 LED G. NIC2 LED Figure 3. Front Controls and LEDs (SR1530SH) Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 26
    the server system includes the following buttons and LEDs. B E A CD GF AF001573 A. NIC1 LED B. NIC2 LED C. Power LED D. System Status LED E. HDD Activity LED F. USB Port G. Power Button H. Figure 4. Front Controls and LEDs (SR1530HSH) 6 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 27
    Solid Green Blinking Green Off Solid Green Solid Amber Description No network connection Network connection in place Transmit/receive activity 10 Mbps connection (if left LED is on or blinking) 100 Mbps connection 1000 Mbps connection Intel® Server System SR1530SH/SR1530HSH User's Guide 7
  • Intel SR1530HSH | User Guide - Page 28
    instructions on installing hard drives, see "Installing and Removing a Hard Drive (SR1530SH)" on page 37. Note: Each drive can consume up to 17 W of power. Drives must be specified to run at a maximum ambient temperature of 45 ° C. Note: The Intel® Server System SR1530SH / SR1530HSH does not support
  • Intel SR1530HSH | User Guide - Page 29
    1 on page x for an Internet link to a list of supported hardware. Intel provides accessory kits for these drives. For installation instructions for an optical drive, see "Installing or Removing a Slimline Optical Drive (SR1530SH)" on page 46. Intel® Server System SR1530SH/SR1530HSH User's Guide 9
  • Intel SR1530HSH | User Guide - Page 30
    Air Duct E. PCIe* Riser Assembly F. Processor and Heat Sink G. Power Supply H. System Memory DIMM Sockets I. System Blower Fans (two) J. Hard Drive Bays K. Front Panel L. Slimline Optical Drive Bay Figure 6. System Components (SR1530SH) 10 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 31
    Server Board F. PCIe* Riser Assembly G. Processor and Heat Sink H. Power Supply I. Front Panel Board J. Front Panel K. Hard Drive Carriers (two) L. Slimline Optical Drive Bay M. Hard Drive Carrier (one) Figure 7. System Components (SR1530HSH) Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 32
    F. Back Panel Connectors I. 2X4 Aux Power Connector L. Channel 1 DIMM Sockets O. Battery R. Floppy Connector U. SATA1 X. Front Panel Header AA. SATA 3 DD. CMOS Clear Jumper GG. Serial Port Figure 8. S3200SH Connector and Component Locations 12 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 33
    the CMOS clear operation was successful. This setting enforces default BIOS settings, which you can change by entering setup pressing F2, then exiting setup pressing F10 and saving changes. Figure 9. Configuration Jumper Descriptions Intel® Server System SR1530SH/SR1530HSH User's Guide 13
  • Intel SR1530HSH | User Guide - Page 34
    3000 series and Intel® Xeon® processor 3100 series, and Intel® Xeon® processor 3200 series and Intel® Xeon® processor 3300 series. For a complete list of supported processors, see the links under "Server System References" on page x. Memory The Intel® Server System SR1530SH / SR1530HSH provides four
  • Intel SR1530HSH | User Guide - Page 35
    . A user can change these parameters if they have adequate security rights. If a value cannot be changed for any reason, the feature's value field is inaccessible. Intel® Server System SR1530SH/SR1530HSH User's Guide 15
  • Intel SR1530HSH | User Guide - Page 36
    "Setup Menu Key Use" describes the keyboard commands you can use in the BIOS Setup menus. Table 4. Setup Menu Key Use Key to Press Description where they were before was pressed without affecting any existing field values. 16 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 37
    when you see the following message: Press Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip Step 2. You need these settings to configure your server at the end of the procedure. Intel® Server System SR1530SH/SR1530HSH User's Guide 17
  • Intel SR1530HSH | User Guide - Page 38
    Note: You may encounter a CMOS Checksum error or other problem after reboot. If this happens, shut down the system and boot it again. CMOS checksum errors require that you enter Setup, check your settings, save your settings, and exit Setup. 18 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 39
    the system begins beeping, power it down and disconnect the AC power. 6. Return the CMOS Clear jumper to the CMOS Clear by BMC location, covering pins 1 and 2. 7. Close the server chassis. 8. Reconnect the AC power and power up the system. Intel® Server System SR1530SH/SR1530HSH User's Guide 19
  • Intel SR1530HSH | User Guide - Page 40
    20 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 41
    the AC power cord from the system or wall outlet. Note: Some components in the Intel® Server System SR1530HSH are hot-swappable and are noted as such (where applicable) in the following instructions. Note: Most of the illustrations in this chapter show the Intel® Server System SR1530SH with an
  • Intel SR1530HSH | User Guide - Page 42
    make sure you position your bezel as shown. Removing the Front Bezel If your system includes a front bezel, use the following steps. 1. Unlock the bezel. 2. Pull the bezel from the server system. Figure 11. Removing the Front Bezel AF002316 22 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 43
    the bezel, line up the center notch on the bezel with the center guide on the rack handles. 2. Push the bezel onto the front of the server system until it clicks into place. 3. Lock the bezel. Figure 12. Installing the Front Bezel AF002317 Intel® Server System SR1530SH/SR1530HSH User's Guide 23
  • Intel SR1530HSH | User Guide - Page 44
    rearward on the blue grip point at the front of the server. Slide the cover back until it stops and then lift the cover upward to remove it. See letter "C" in Figure 13. B C A AF000662 Figure 13. Removing the Server System Cover (SR1530SH) 24 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 45
    rearward on the blue grip point at the front of the server. Slide the cover back until it stops and then lift the cover upward to remove it. See letter "B" in Figure 14. B A AF001578 Figure 14. Removing the Server System Cover (SR1530HSH) Intel® Server System SR1530SH/SR1530HSH User's Guide 25
  • Intel SR1530HSH | User Guide - Page 46
    the server system so the side edges of the cover sit just inside the server system sidewalls. Slide the cover forward. See letter "A" in Figure 16. 6. SR1530HSH: Install the four screws at the front of the server. See letter "B" in Figure 16. 26 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 47
    the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover". 4. Lift the processor air duct from its location behind the two system blower fans (see Figure 17 for SR1530SH; see Figure 18 for SR1530HSH). Intel® Server System SR1530SH/SR1530HSH User
  • Intel SR1530HSH | User Guide - Page 48
    AF002318 Figure 17. Removing the Processor Air Duct (SR1530SH) AF002319 Figure 18. Removing the Processor Air Duct (SR1530HSH) 28 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 49
    caution not to pinch or disengage cables that may be near or under the air duct. 5. Install the server system cover. For instructions, see "Installing the Server System Cover". AF002320 Figure 19. Installing the Processor Air Duct (SR1530SH) Intel® Server System SR1530SH/SR1530HSH User's Guide 29
  • Intel SR1530HSH | User Guide - Page 50
    the Processor Air Duct (SR1530HSH) Installing and Removing Memory Caution: The memory is NOT hot-swappable. Before removing or replacing any memory DIMM, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power
  • Intel SR1530HSH | User Guide - Page 51
    power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 24. 4. Locate the DIMM sockets. See Figure 21. C D A B DIMM 1A Socket DIMM 2A Socket Figure 21. Installing the Memory 21. Intel® Server System SR1530SH/SR1530HSH User's Guide 31
  • Intel SR1530HSH | User Guide - Page 52
    lifts from the socket. 6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. 7. Install the server system cover. For instructions, see "Installing the Server System Cover". 32 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 53
    load plate. 9. Remove the processor. 10. If installing a replacement processor, see "Installing the Processor" on page 34. Otherwise, install the protective socket cover over the empty processor socket and then reinstall the chassis cover. Intel® Server System SR1530SH/SR1530HSH User's Guide 33
  • Intel SR1530HSH | User Guide - Page 54
    Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 24. 4. Locate the processor very sensitive and easily damaged. 34 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 55
    the protective socket cover. See Figure 26. A B AF000530 Figure 26. Removing the Protective Socket Cover Note: Retain the protective socket cover for use when removing a processor that will not be replaced. Intel® Server System SR1530SH/SR1530HSH User's Guide 35
  • Intel SR1530HSH | User Guide - Page 56
    Heat Sink Before installing the heat sink, you must install your processor. For instructions, see "Installing the Processor" on page 34. Caution: The heat sink has Thermal Interface FCrohnatssis AF001049 Figure 27. Installing the Heat Sink 36 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 57
    Power down the server. Unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 24. 4. Locate the drive position you want to use. See Figure 28. Intel® Server System SR1530SH/SR1530HSH User's Guide 37
  • Intel SR1530HSH | User Guide - Page 58
    1 AF002322 Figure 28. Locating Drive Positions (SR1530SH) 5. HDD1 location only: Slide the power cables from the cable clip located on the top A B ChFarsosnist AF001050 Figure 29. Removing Drive Carrier from the Server System (SR1530SH) 38 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 59
    as shown by the letter "A" in the figure. The data and power connectors must be positioned so they are accessible through the cut-out as system. C A HDD 0 B HDD 1 AF002323 Figure 31. Install Drive Assembly into the Server System (SR1530SH) Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 60
    in the HDD0 carrier, attach the middle connector on the daisy chain power cable to the HDD0 power connector. See letter "D" in Figure 32. A B CD CD F E E AF002324 Figure 32. Connecting Hard Drive Power and Data Cables (SR1530SH) 40 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 61
    drive, skip the rest of these steps and instead see "Installing a Hard Disk Drive (SR1530SH)" on page 37, beginning with step 8. 10. Insert the screws that held the drive in the carrier into the screw locations on the carrier for future use. Intel® Server System SR1530SH/SR1530HSH User's Guide 41
  • Intel SR1530HSH | User Guide - Page 62
    the screw that you removed in Step 6. Note: You must install the assembly that contains the optical drive bracket at the left side of the system. 13. Install the server system cover. For instructions, see "Installing the Server System Cover". 42 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 63
    SR1530HSH) 1. If it is installed, remove the front bezel. For instructions, see "Removing the Front Bezel". 2. Locate the drive position you want to use. See Figure 34. HDD 0 HDD 1 HDD 2 AF002325 Figure 34. Locating Drive Positions (SR1530HSH) Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 64
    . 7. Set any jumpers and/or switches on the drive according to the drive manufacturer's instructions. 8. With the drive circuit-side down, position the connector end of the drive so it Figure 36. Installing Drive into Drive Carrier (SR1530HSH) 44 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 65
    on the carrier for future use. 7. With the black lever in the fully open position, slide the drive carrier into the server system. The green latch must be to the right. Do not push on the black lever until the lever begins to close by itself. Intel® Server System SR1530SH/SR1530HSH User's Guide 45
  • Intel SR1530HSH | User Guide - Page 66
    on page iii. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 24. pegs (see letter "B" in Figure 38). 46 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 67
    B A AF002326 Figure 38. Lifting PCI Cooling Fan from Mounting Pegs (SR1530SH) 6. First time installation only: Remove the knock-out by rocking it back and forth. See optical drive to the brackets, using the four screws as shown in Figure 40. Intel® Server System SR1530SH/SR1530HSH User's Guide 47
  • Intel SR1530HSH | User Guide - Page 68
    10. Connect the mini SATA power connector on the optical drive. 11. Connect the data cable to the optical drive and to the SATA connector on the server board. B C C A D D AF003095 Figure 41. Installing the Optical Drive into the System 48 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 69
    " on page 22. 5. SR1530SH: Note the orientation of the PCI cooling fan located behind the optical drive bay, then disconnect the fan cable (see letter "A" in Figure 43) and lift the fan from the mounting pegs (see letter "B" in Figure 43). Intel® Server System SR1530SH/SR1530HSH User's Guide 49
  • Intel SR1530HSH | User Guide - Page 70
    letter "C" in Figure 44. Save this screw. You will reinstall it later. 8. Slide the optical drive out through the front of the system. See letter "D" in Figure 44. C D B A AF000670 Figure 44. Removing the Optical Drive from the Server System 50 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 71
    bay (see letter "A" in Figure 46). The fan label should face the rear of the system. Connect the fan cable to the connector on the server board (see letter "B" in Figure 46). A B AF002328 Figure 46. Installing the PCI Cooling Fan (SR1530SH) Intel® Server System SR1530SH/SR1530HSH User's Guide 51
  • Intel SR1530HSH | User Guide - Page 72
    it is installed. For instructions, see "Removing the Front Bezel" on page 22. 5. First time installation only: Remove the peripheral knock-out by rocking it back and forth. 6. Attach the optical drive attachment bracket as shown in Figure 47. 52 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 73
    ". Removing a Slimline Optical Drive (SR1530HSH) 1. Observe the safety and ESD precautions at the beginning of this book. See "Safety Information" on page iii. 2. Power down the server and unplug all peripheral devices and the AC power cable. Intel® Server System SR1530SH/SR1530HSH User's Guide 53
  • Intel SR1530HSH | User Guide - Page 74
    Optical Drive from the Attachment Bracket 7. (Optional) Install the front bezel. For instructions, see "Installing the Front Bezel" on page 23. 8. Install the server system cover. For instructions, see "Installing the Server System Cover". 54 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 75
    Lift riser assembly up to remove it. Use caution to gently ease the riser card from the add-in card slot so you do not damage the slot or the riser card. See Figure 51. AF002329 Figure 51. Removing PCIe* Riser Assembly from the Server System Intel® Server System SR1530SH/SR1530HSH User's Guide 55
  • Intel SR1530HSH | User Guide - Page 76
    server system back panel slots. The riser cards will seat into the matching sockets on the server board. 4. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. 56 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 77
    instructions, see "Removing a PCI Add-in Card" on page 60. 7. Remove the two screws that attach the riser card to the riser assembly. See Figure 53. Save these screws to be used later. AF001061 Figure 53. Removing Riser Card from Riser Assembly Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 78
    8. Install an PCI add-in card if desired. For instructions, see "Installing a PCI Add-in Card" on page 59. 9. Install the PCIe* Riser assembly into the server system. For instructions, see "Installing the PCIe* Riser Assembly" on page 56. 58 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 79
    devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 24. 4. Remove the PCIe* Riser assembly. For instructions, see "Removing the PCIe* Riser Assembly" on page 55. Intel® Server System SR1530SH/SR1530HSH User's Guide 59
  • Intel SR1530HSH | User Guide - Page 80
    devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 24. 4. Remove the PCIe* Riser assembly. For instructions, see "Removing the PCIe* Riser Assembly" on page 55. 60 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 81
    . For instructions, see "Installing the Processor Air Duct" on page 29. 11. Install the server system cover. For instructions, see "Installing the Server System Cover". 12. Plug all peripheral devices and the AC power cable into the server. Intel® Server System SR1530SH/SR1530HSH User's Guide 61
  • Intel SR1530HSH | User Guide - Page 82
    . 6. Detach all cables connected to the server board. 7. Remove the heat sink and the processor. For instructions, see "Removing the Heat Sink and Processor" on page 33. 8. Remove the DIMMs. For instructions, see "Removing DIMMs" on page 32. 62 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 83
    diagram, see Figure 80 on page 88. 15. Install the processor air duct. For instructions, see "Installing the Processor Air Duct" on page 29. 16. Install the server system cover. For instructions, see "Installing the Server System Cover". Intel® Server System SR1530SH/SR1530HSH User's Guide 63
  • Intel SR1530HSH | User Guide - Page 84
    Riser Assembly" on page 55. 6. Place the server board into the server system as shown by letter "A" in Figure 58. 7. Attach the server board with nine screws. See letter "B" in Figure 58. B A Figure 58. Installing the Server Board AF002332 64 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 85
    the PCIe* Riser Assembly" on page 56. 13. Install the processor air duct. For instructions, see "Installing the Processor Air Duct" on page 29. 14. Install the server system cover. For instructions, see "Installing the Server System Cover". 15. Plug all peripheral devices and the AC power cable into
  • Intel SR1530HSH | User Guide - Page 86
    lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run the BIOS Setup utility to restore the configuration settings. 66 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 87
    - B: 2x12 main power connector - C: Daisy-chain cable to: ✧ Optical drive power connector, if an optical drive is installed ✧ HDD0 power connector, if a hard drive is installed here ✧ HDD1 power connector, if a hard drive is installed here Intel® Server System SR1530SH/SR1530HSH User's Guide 67
  • Intel SR1530HSH | User Guide - Page 88
    . A B C D E AF002473 Figure 60. Disconnecting Power Cables (SR1530SH) 68 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 89
    the foot at the bottom of the chassis. See letter "B" in Figure 61. 7. Slide the power supply forward (see letter "C") and then lift it from the chassis. A B C B AF002474 Figure 61. Removing Power Supply from the Server System (SR1530SH) Intel® Server System SR1530SH/SR1530HSH User's Guide 69
  • Intel SR1530HSH | User Guide - Page 90
    letter "B" in Figure 62. 10. Insert the screw you removed in Step 5 to attach the power supply to the server system. See letter "C" in Figure 62. C B A B AF002475 Figure 62. Installing Power Supply Module into the Server System (SR1530SH) 70 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 91
    supply. . A B C D E AF002476 Figure 63. Connecting Power Cables (SR1530SH) 12. Install the server system cover. For instructions, see "Installing the Server System Cover". 13. Plug all peripheral devices and the AC power cable into the server. Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 92
    bottom of the chassis (see letter "B" in Figure 64). 6. Slide the power supply forward (see letter "C" in Figure 64) and then lift it from the chassis. A B C B AF002477 Figure 64. Removing Power Supply from the Server System (SR1530HSH) 72 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 93
    the power supply cables to the server board and peripherals. 10. Install the server system cover. For instructions, see "Installing the Server System Cover". 11. Plug all peripheral devices and the AC power cable into the server (see letter "C" in Figure 65). Intel® Server System SR1530SH/SR1530HSH
  • Intel SR1530HSH | User Guide - Page 94
    "D" in Figure 66. Save these screws. You will re-install them later. 7. Lift the front panel board from the system. See letter "E" in Figure 66. A B C D E AF002479 Figure 66. Removing Front Panel Board from the Server System (SR1530SH) 74 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 95
    Figure 67. Installing Front Panel Board into the Server System (SR1530SH) 13. Install the server system cover. For instructions, see "Installing the Server System Cover". 14. Plug all peripheral devices and the AC power cable into the server. Intel® Server System SR1530SH/SR1530HSH User's Guide 75
  • Intel SR1530HSH | User Guide - Page 96
    it later. 6. Slide the front panel board back (see letter "B" in Figure 68) and lift the front panel board from the system (see letter "C" in Figure 68). A B C AF001589 Figure 68. Removing Front Panel Board from the Server System (SR1530HSH) 76 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 97
    (see letter "B" in Figure 70). 9. Use the screw you removed in Step 5 to attach the front panel board to the system (see letter "C" in Figure 70). C B A AF001590 Figure 70. Installing Front Panel Board into the Server System (SR1530HSH) Intel® Server System SR1530SH/SR1530HSH User's Guide 77
  • Intel SR1530HSH | User Guide - Page 98
    cable if you removed it in Step 4. 12. Connect the front panel cable. 13. Install the server system cover. For instructions, see "Installing the Server System Cover". 14. Plug all peripheral devices and the AC power cable into the server. 78 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 99
    the Processor Air Duct" on page 27. 5. Disconnect the two fan cables from the server board (see letter "B" in Figure 72) and untie the cable tie (see letter "C" in Figure 72). A B C AF002481 Figure 72. Disconnecting System Blower Fans (SR1530SH) Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 100
    from the server. Lift the bracket at an angle, front of the bracket first, to clear the hard disk drive brackets. See letter "C" in Figure 73. A C B AF002482 Figure 73. Removing Bracket and System Blower Fans from Server System (SR1530SH) 80 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 101
    bracket. See letter "B" in Figure 74. B A AF000963 Figure 74. Removing Fan from Fan Bracket (SR1530SH) 11. Install the replacement fan onto the bracket, using the two screws you removed in Step 9. 12. Set at the front of the fan bracket. Intel® Server System SR1530SH/SR1530HSH User's Guide 81
  • Intel SR1530HSH | User Guide - Page 102
    the fans to the server board. See letters "A" and "B" in Figure 75. B A AF002483 Figure 75. Connecting System Blower Fans (SR1530SH) 15. Install the processor air duct. For instructions. see "Installing the Processor Air Duct" on page 29. 82 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 103
    For instructions, see "Removing the Processor Air Duct" on page 27. 5. Remove the two screws that hold the fan in place. Save these screws. You will re- install them later. 6. Disconnect the fan cable from the server board (see letter "B" in Figure 76). Intel® Server System SR1530SH/SR1530HSH User
  • Intel SR1530HSH | User Guide - Page 104
    A AF001634 Figure 77. Installing Fan into the Server System (SR1530HSH) 11. Install the server system cover. For instructions, see "Installing the Server System Cover". 12. Plug all peripheral devices and the AC power cable into the server. 84 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 105
    5. Repeat Step 4 on the opposite side of the server. 6. (Optional) Install the front bezel, if desired. For instructions, see "Installing the Front Bezel" on page 23. 7. Plug all peripheral devices and the AC power cable into the server. Intel® Server System SR1530SH/SR1530HSH User's Guide 85
  • Intel SR1530HSH | User Guide - Page 106
    5. Repeat Step 4 on the opposite side of the system. 6. (Optional) Install the front bezel, if desired. For instructions, see "Installing the Front Bezel" on page 23. 7. Plug all peripheral devices and the AC power cable into the server. 86 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 107
    routing. For readability, separate figures for power cable routing and data cable routing are included. Make sure all necessary power and data cables are connected and where it connects to the server board and at the PCI cooling fan itself. Intel® Server System SR1530SH/SR1530HSH User's Guide 87
  • Intel SR1530HSH | User Guide - Page 108
    . To make Figure 80 more clear, where the connectors attach to the components, the labels "F1", "F2", and "F3" are used. The end at the power supply itself is labeled "F". 88 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 109
    Data Cable Routing (SR1530SH) A C D B E AF002485 A. Front panel USB B. Front panel C. SATA 1 to HDD1 D. SATA 0 to HDD0 E. Optical drive Figure 81. Data Cable Routing (SR1530SH) Intel® Server System SR1530SH/SR1530HSH User's Guide 89
  • Intel SR1530HSH | User Guide - Page 110
    USB E Front Panel F Blower Fan #1 Power G Blower Fan #2 Power H HDD 0 to Server Board SATA 2 I HDD 1 to Server Board SATA 3 J HDD 2 to Server Board SATA 4 K Optical Drive to Server Board SATA 0 Figure 82. Cable Routing (SR1530HSH) AF002486 90 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 111
    2 A 24 A 0.3 A Maximum Current Warning: Do not exceed a combined power output of 90 W for the +5 V and +3.3 V outputs. Exceeding a combined 90 W will overload the power subsystem and may cause the power supplies to overheat and malfunction. Intel® Server System SR1530SH/SR1530HSH User's Guide 91
  • Intel SR1530HSH | User Guide - Page 112
    msec, 1/2 sine Operational after an 24-inch free fall. 7 Bels in sound power for a typical office ambient temperature (65 to 75 °F). Your selection of peripherals may change the noise level. Tested to 15 kilovolts (kV); no component damage. 92 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 113
    system memory, restarts POST, reloads the operating system, and halts power to all peripherals Reset the BMC and get it back to a stable state Press Reset button Power off/on button Remove AC power from the server for one minute Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 114
    integrated components from the tested components lists? Check the tested memory and chassis lists, as well as the supported hardware and operating system list. See "Server System References" on page x for links to the tested component lists. 94 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 115
    not display, see "No Characters Appear on Screen" on page 96. Specific Problems and Corrective Actions This section provides possible solutions for these specific problems: • Power light does not light. • No characters appear on screen. Intel® Server System SR1530SH/SR1530HSH User's Guide 95
  • Intel SR1530HSH | User Guide - Page 116
    pins on the bottom of the server board and cause a short. No Characters Appear on Screen Check the following: • Is the keyboard functioning? Test it by turning the "Num Lock" function on and off to make sure the Num Lock light is functioning. 96 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 117
    ? • Does this video monitor work correctly if plugged into a different system? System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, it is an indication of possible system component failure. Intel® Server System SR1530SH/SR1530HSH User's Guide 97
  • Intel SR1530HSH | User Guide - Page 118
    securely attached to the correct connector at the system back panel. • Try a different network cable. • Make sure you are using the correct and the current drivers. See "Server System References" on page x for a link to the current drivers. 98 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 119
    supports shared interrupts. • Try reseating the add-in adapter. The add-in adapter stopped working without apparent cause • Reseat the adapter. • The network driver files may be corrupt or deleted. Delete and then reinstall the drivers. • Run diagnostics. Intel® Server System SR1530SH/SR1530HSH
  • Intel SR1530HSH | User Guide - Page 120
    is incorrect), a marginal power supply, or other random component failures. • If you suspect a transient voltage spike, power outage, or brownout might have occurred, reload the software and try running it again. Symptoms of voltage spikes 100 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 121
    a RAID configuration with SCSI or SATA drives, make sure the RAID card is installed correctly. Bootable CD-ROM Disk Is Not Detected Check the following: • Make sure the BIOS is configured to allow the CD-ROM to be the first bootable device. Intel® Server System SR1530SH/SR1530HSH User's Guide 101
  • Intel SR1530HSH | User Guide - Page 122
    one at a time, booting the system between each card addition, until the beeps again occur to reveal the malfunctioning card. Replace or reseat the system video add-in card. If on-board video is being used, the server board may be faulty. 102 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 123
    some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. Intel® Server System SR1530SH/SR1530HSH User's Guide 103
  • Intel SR1530HSH | User Guide - Page 124
    equipment manufacturer. Dispose of used batteries according to manufacturer's instructions. The system is designed to operate in a typical office environment. power supply cord(s), because they serve as the product's main power disconnect. 104 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 125
    . 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Server System SR1530SH/SR1530HSH User's Guide 105
  • Intel SR1530HSH | User Guide - Page 126
    anzubringen: 1. Vergewissern Sie sich, daß Sie keine Werkzeuge oder Teile im Innern des Systems zurückgelassen haben. 2. Überprüfen Sie alle Kabel, Zusatzkarten und andere Komponenten Batterien den Anweisungen des Herstellers entsprechend. 106 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 127
    Français Das System wurde für den Betrieb in einer normalen Büroumgebung entwickelt. Der Standort sollte: • "sauber und staubfrei sein (Hausstaub mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. Intel® Server System SR1530SH/SR1530HSH User's Guide 107
  • Intel SR1530HSH | User Guide - Page 128
    a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. 108 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 129
    type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. ón de corriente alterna que tenga el producto Intel® Server System SR1530SH/SR1530HSH User's Guide 109
  • Intel SR1530HSH | User Guide - Page 130
    sistema y bloquéelo para impedir que pueda accederse al mismo sin autorización. 5. Conecte todos los cables externos y los cables de alimentación CA al sistema. 110 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 131
    tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Server System SR1530SH/SR1530HSH User's Guide 111
  • Intel SR1530HSH | User Guide - Page 132
    lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 133
    di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Server System SR1530SH/SR1530HSH User's Guide 113
  • Intel SR1530HSH | User Guide - Page 134
    114 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 135
    if the WARNING is ignored. Indicates potential hazard if indicated information is ignored. Indicates shock hazards that result in serious injury or death if safety instructions are not followed. Indicates hot components or surfaces. Intel® Server System SR1530SH/SR1530HSH User's Guide 115
  • Intel SR1530HSH | User Guide - Page 136
    . • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Equipment Handling Practices Reduce the risk of for easier handling, remove any easily detachable components. 116 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 137
    disconnect device to AC power. The socket outlet(s) must be near the equipment and readily accessible for disconnection. - The power supply cord(s) must be plugged into socket-outlet(s) that is /are provided with a suitable earth ground. Intel® Server System SR1530SH/SR1530HSH User's Guide 117
  • Intel SR1530HSH | User Guide - Page 138
    , and it must be labeled as controlling power to the entire unit, not just to the server(s). To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it. 118 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 139
    system. • Check that cables, add-in boards, and other components are properly installed. • Attach the covers to the chassis according to the product instructions. devices have are not user serviceable. • Return to manufacturer for servicing. Intel® Server System SR1530SH/SR1530HSH User's Guide 119
  • Intel SR1530HSH | User Guide - Page 140
    hin, der bei Nichtbeachtung der Sicherheitshinweise zu schweren oder tödlichen Verletzungen führen kann. Weist auf Verbrennungsgefahr an heißen Bauteilen bzw. Oberflächen hin. 120 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 141
    äte erzeugt werden. • In gewittergefährdeten Gebieten sollten Sie das System an einen Überspannungsschutz anschließen und bei einem Gewitter die Telekommunikationskabel lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Server System SR1530SH/SR1530HSH User's Guide 121
  • Intel SR1530HSH | User Guide - Page 142
    vom Stromnetz. Die Steckdose muß in der Nähe der Anlage angebracht und gut erreichbar sein. • Netzkabel müssen an eine ordnungsgemäß geerdete Steckdose angeschlossen sein. 122 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 143
    vor, und bauen Sie das schwerste Gerät an der untersten Position im Rack ein. Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus. Intel® Server System SR1530SH/SR1530HSH User's Guide 123
  • Intel SR1530HSH | User Guide - Page 144
    . Die Inbetriebnahme des Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen Sie die Abdeckung wieder an: • Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben. 124 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 145
    uniquement par des techniciens qualifiés. Vous devez suivre les informations de ce guide et les instructions d'assemblage des manuels de serveur pour vérifier et maintenir la conformité et peuvent figurer sur le produit ou sur son emballage. Intel® Server System SR1530SH/SR1530HSH User's Guide 125
  • Intel SR1530HSH | User Guide - Page 146
    soleil et les radiateurs. • À l'écart des sources de vibration ou des chocs physiques. • Isolé des champs électromagnétiques importants produits par des appareils électriques. 126 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 147
    ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage alimentation. L'intérieur de celui-ci est soumis à des Intel® Server System SR1530SH/SR1530HSH User's Guide 127
  • Intel SR1530HSH | User Guide - Page 148
    Les cordons d'alimentation doivent répondre aux critères suivants : - Le cordon d'alimentation doit supporter une intensité supérieure à celle indiquée sur le produit. - Le cordon d'alimentation communication qui sont connectés au système. 128 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 149
    montage en rack Le rack doit être fixé à un support inamovible pour éviter qu'il ne bascule lors de l'extension quipement. Le rack doit être installé conformément aux instructions du fabricant. Installez les équipements dans le rack en partant Intel® Server System SR1530SH/SR1530HSH User's Guide 129
  • Intel SR1530HSH | User Guide - Page 150
    système. • Vérifiez que les câbles, les cartes d'extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. 130 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 151
    irse a las directrices de esta guía y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con las certificaciones y homologaciones existentes de graves si no se tiene en cuenta la ADVERTENCIA. Intel® Server System SR1530SH/SR1530HSH User's Guide 131
  • Intel SR1530HSH | User Guide - Page 152
    conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. 132 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 153
    conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use adquiera alguno cuyo uso esté aprobado en su país. Intel® Server System SR1530SH/SR1530HSH User's Guide 133
  • Intel SR1530HSH | User Guide - Page 154
    para repararla. • Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que no es de conexión en funcionamiento. 134 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 155
    los componentes que estén calientes cuando esté realizando una instalación de conexión en funcionamiento, tenga cuidado al extraer o instalar los componentes de conexión en funcionamiento. Intel® Server System SR1530SH/SR1530HSH User's Guide 135
  • Intel SR1530HSH | User Guide - Page 156
    servidor, colóquela con el lado de los componentes hacia arriba sobre una superficie con toma de tierra y sin carga estática. Utilice una 136 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 157
    caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare Intel® Server System SR1530SH/SR1530HSH User's Guide 137
  • Intel SR1530HSH | User Guide - Page 158
    简体中文 Intel Intel Intel Web UL 138 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 159
    ITE ITE 场地选择 5V Intel® Server System SR1530SH/SR1530HSH User's Guide 139
  • Intel SR1530HSH | User Guide - Page 160
    140 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 161
    ESD) ESD ESD ESD ESD Intel® Server System SR1530SH/SR1530HSH User's Guide 141
  • Intel SR1530HSH | User Guide - Page 162
    其他危险 替换电池 142 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 163
    the server system, power supply, and other modules have passed EMC testing using a server board server system complies with the following product safety requirements: • UL60950 - CSA 60950 (USA/Canada) • EN60950 (Europe) • IEC60950 (International) Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 164
    Intel® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative. • FCC /ICES-003 - Emissions (USA/Canada MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) (Korea) 144 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 165
    regulatory marks. Table 10. Product Regulatory Compliance Markings Regulatory Compliance Region cULus Listing Marks USA/Canada Marking GS Mark Germany CE Mark Europe FCC Marking (Class A) USA EMC Marking (Class A) Canada Intel® Server System SR1530SH/SR1530HSH User's Guide 145
  • Intel SR1530HSH | User Guide - Page 166
    Region C-Tick Mark Australia/New Zealand Marking VCCI Marking (Class A) Japan BSMI Certification Number & Class A Warning Taiwan GOST R Marking RRL MIC Mark Russia Korea 146 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 167
    to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Intel® Server System SR1530SH/SR1530HSH User's Guide 147
  • Intel SR1530HSH | User Guide - Page 168
    Industry Canada (ICES-003) Cet appareil numérique respecte les limites bruits radioé according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. 148 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 169
    Storage Devices: must be a UL recognized or UL listed accessory and TUV or VDE licensed. Maximum power rating of any one device is 19 watts. Total server configuration is not to exceed the maximum loading conditions of the power supply. Intel® Server System SR1530SH/SR1530HSH User's Guide 149
  • Intel SR1530HSH | User Guide - Page 170
    for: - Cadmium End-of-Life/Product Recycling Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and/or take-back. 150 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 171
    substantially conform to Intel's publicly available specifications for a period of three (3) years after the date the Product was purchased from an Intel authorized distributor. Software characterized errata are available upon request. Intel® Server System SR1530SH/SR1530HSH User's Guide 151
  • Intel SR1530HSH | User Guide - Page 172
    due to external causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper Limited Warranty, the English language version shall control. 152 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 173
    www.intel.com/), call your local distributor or an Intel Customer Support representative. See "Getting Help" for telephone numbers. Returning a Defective Product Before returning any product, call your authorized dealer/distribution authority. Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 174
    154 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 175
    support.intel.com/support/motherboards/server/S3200SH. For the fastest service, please submit your form via the Internet. For an updated support contact list, see http://www.intel.com/support/9089.htm/ U.S. and Canada 1251 UK 870 6072439 Intel® Server System SR1530SH/SR1530HSH User's Guide 155
  • Intel SR1530HSH | User Guide - Page 176
    8 621 33104691 (not toll-free) Hong Kong 852 2 844 4456 India........... 0006517 2 68303634 (manual toll-free. You need an IDD-equipped telephone) Indonesia ... 803 65 7249 Korea ......... 822 767 225 288. Once connected, dial 800 843 4481 156 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • Intel SR1530HSH | User Guide - Page 177
    0114 Peru 001 916 377 0114 Uruguay..... 001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Server System SR1530SH/SR1530HSH User's Guide 157
  • Intel SR1530HSH | User Guide - Page 178
    158 Intel® Server System SR1530SH/SR1530HSH User's Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Intel
®
Server System SR1530SH/
SR1530HSH User’s Guide
A Guide for Technically Qualified Assemblers of Intel
®
Identified Subassemblies/
Products