    Intel® Server System SR1680MV Service Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Intel Order Number E74835-005
  • Intel SR1680MV | Service Guide - Page 2
    Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2010, Intel Corporation. All Rights Reserved ii Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 3
    SATA RAID options and how to configure RAID sets. Chapter 7 provides instructions for installing rail kit to racks. At the back of this book, you will find an issue report form, troubleshooting information, regulatory information, and safety information. Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 4
    product are available on the Intel Resource CD-ROM that shipped with your Intel server product. You can obtain software updates and additional information at the following Intel website: http://support.intel.com/support/motherboards/server/SR1680MV/ iv Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 5
    Configuration Guide Tested Hardware Operating Systems List Supported Processors List Supported Memory List Driver (for an extensive list of drivers available) Operating System Driver (for operating system drivers) Firmware Update Package Power Budget Tool Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 6
    vi Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 7
    ón de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel® Server Resource CD y/o en http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Intel® Server System SR1680MV Service Guide vii
  • Intel SR1680MV | Service Guide - Page 8
    http://support.intel.com/support/motherboards/server/sb/CS-010770.htmϞⱘ,QWHO 6HUYHU%RDUGVDQG6HUYHU&KDVVLV6DIHW\,QIRUPDWLRQ˄lj,QWHO viii Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 9
    the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Server System SR1680MV Service Guide ix
  • Intel SR1680MV | Service Guide - Page 10
    x Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 11
    the Processor 15 Removing the Heatsink 16 Installing the Heatsink 17 System Memory ...17 System Memory Channel Population Requirements for Memory RAS Modes 19 Independent Channel Mode 19 Mirrored Channel Mode 19 Lockstep Channel Mode 19 Intel® Server System SR1680MV Service Guide xi
  • Intel SR1680MV | Service Guide - Page 12
    Power Supply Module ...27 Removing the Power Supply Module 27 Installing the Power Supply Module 28 Power Distribution Board ...28 Removing the Power Distribution Board 29 Installing the Power 54 Connectors and Component Locations of PDB 55 xii Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 13
    SATA RAID 99 Enabling RAID in the BIOS Setup 99 Chapter 7: Installing the Rackmount Rail Kits 101 Procedure to install the rail kit 102 Appendix A: Intel® Server Issue Report Form 105 Appendix B: Troubleshooting 111 Resetting the System ...111 Problems following Initial System Installation
  • Intel SR1680MV | Service Guide - Page 14
    BIOS POST Beep Codes 116 Appendix C: Installation/Assembly Safety Instructions 119 English ...119 Deutsch ...121 Français ...123 Español ...125 Italiano ...127 Appendix D: Safety Information 131 English ...131 Server Selección de la ubicación 146 xiv Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 15
    159 Product Regulatory Compliance Markings 160 Rack Mount Installation Guidelines 165 Power Cord Usage Guidelines 166 Electromagnetic Compatibility 170 Regulated Specified Components 170 Appendix F: Warranty 173 Appendix G: Getting Help 175 Intel® Server System SR1680MV Service Guide xv
  • Intel SR1680MV | Service Guide - Page 16
    xvi Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 17
    Backplane Location 32 Figure 38. Remove the Screws and Lift the Backplane Up 33 Figure 39. System Fans Location 34 Figure 40. Lift a System Fan Up from I/O Board Cage Module 34 Figure 41. Lift Air Duct Up ...35 Figure 42. PCI-E Cage Location 36 Intel® Server System SR1680MV Service Guide xvii
  • Intel SR1680MV | Service Guide - Page 18
    Holes 102 Figure 66. Secure screw into the rail hole 103 Figure 67. Secure the Rail to Racks 103 Figure 68. Slide The Server Into Racks 103 Figure 69. Push The Server To The End Of Racks 104 Figure 70. Secure The Server Ears To Racks 104 xviii Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 19
    37. CD/DVD Drives Submenu 90 Table 38. Security Menu of BIOS Setup Utility 91 Table 39. Security Menu Fields 92 Table 40. Trusted Computing Submenu 93 Table 41. Trusted Computing Submenu Fields 94 Table 42. Exit Menu of BIOS Setup Utility 95 Intel® Server System SR1680MV Service Guide xix
  • Intel SR1680MV | Service Guide - Page 20
    Depth for Racks 102 Table 46. Resetting the System 111 Table 47. LED Information ...116 Table 48. POST Error Beep Codes 116 Table 49. Error Beep Codes Generated by Intel® Management Module 117 Table 50. Product Regulatory Compliance Markings 160 xx Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 21
    1. Intel® Server System SR1680MV with 2.5-inch Pluggable HDDs The sever supports two identical motherboards, left and right I/O boards. Two I/O boards have the same function with different placement. Based on the Intel® 5500 chipset platform, each server board uses high-performance, dual processors
  • Intel SR1680MV | Service Guide - Page 22
    Intel® Server System SR1680MV Feature Summary Feature Dimensions Processor Memory On-board LAN On-board VGA Integrated Super I/O Riser and Expansion Card Description • 43.2 mm height • 448 mm width • 714.2 mm depth • Minimum weight: 11.7 kg • Maximum weight: 17.16 kg • Support for up to four Intel
  • Intel SR1680MV | Service Guide - Page 23
    3. PCI-E Cage 4. System Fans 5. Power Distribution Board 6. Server boards 7. Pluggable HDD Backplane 8. Pluggable HDD Bays 9. NIC Card 10. GB I/O Card or InfiniBand* Card (optional) Figure 2. Layout of Server Chassis with 2.5-inch Pluggable HDDs Intel® Server System SR1680MV Service Guide 3
  • Intel SR1680MV | Service Guide - Page 24
    . Front Panel USB Port 11. HDD LED 12. 2.5-inch Pluggable HDDs Figure 3. Front View of Server with 2.5-inch Pluggable HDDs Back View Components The server back view includes connectors, buttons, and system LEDs of both internal and external devices. 4 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 25
    link, system health, UID (unique identifier), and power. The following figures shows the front panel: 1. NIC LED 2. System Health LED 3. Power Button 4. UID Button 5. UID LED 6. Power LED 7. HDD LED Figure 5. Front Panel Buttons and LEDs of Server Intel® Server System SR1680MV Service Guide 5
  • Intel SR1680MV | Service Guide - Page 26
    LED information. LED Information Feature Power LED Table 2. LED Information Color Description Amber Green - Front View LEDs On: System has AC power but in standby mode. On: System has AC power and is turned on. Off: No AC power to the system. 6 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 27
    Green - Blinking: Linked and activity on the network. Off: No connection On: Linked to the network. Off: No connection Blinking: System is being remotely managed On: Identification Off: Disabled On: +12V is output Off: No AC on or no main power on Intel® Server System SR1680MV Service Guide 7
  • Intel SR1680MV | Service Guide - Page 28
    8 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 29
    server product, pay close attention to "Safety Information". This document provides instructions for adding and replacing system components. For instructions on replacing components on the server board, such as the processor and memory pad (recommended) Intel® Server System SR1680MV Service Guide 9
  • Intel SR1680MV | Service Guide - Page 30
    Disconnect all power cords from the server to completely remove power from the system. Pressing the Power Button Press the power button ("1") to toggle the serve to hibernation. The power LED ("2") in TBD turns off. Figure 7. Pressing the Power Button 10 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 31
    the rear top cover, follow this step: 1. Make sure the server is not turned on or connected to the AC power. To power off the server, see "Power Off". Removing the Mid-Top Cover 1. Release the screw on using the traction pad, and then lift it up. Intel® Server System SR1680MV Service Guide 11
  • Intel SR1680MV | Service Guide - Page 32
    ® Xeon® Processor 5600 series. One server node can be configured to either a single- or dual-processor system. The following figure shows the location of processors on the motherboard: Figure 10. Location of Processors 1. Processor 1 2. Processor 2 12 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 33
    see "Power Off" 2. Remove the chassis cover. To remove the cover, see "Mid-Top Cover". Removing the Processor 1. Unlock the load lever and lift it up. 2. Open the load plate. Figure 11. Opening the Load Plate 3. Lift the processor out of the socket. Intel® Server System SR1680MV Service Guide 13
  • Intel SR1680MV | Service Guide - Page 34
    Figure 12. Lifting the Processor Out of the Socket 4. Place the PnP cap onto the load plate. Figure 13. Placing on the PnP Cap 14 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 35
    . Closing the Load Plate Installing the Processor Reverse the steps in "Removing the Processor" to install the processor. However, when inserting the processor into the socket, make sure the golden corner on the processor is pointed toward the socket. Intel® Server System SR1680MV Service Guide 15
  • Intel SR1680MV | Service Guide - Page 36
    to avoid bending the pins and damaging the processor. If the processor does not fit completely, check its orientation or check for bent pins Removing the Heatsink 1. Loosen the two securing screws. 2. Lift the heatsink up from the installed processor. 16 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 37
    up to 72GB memory when 8GB DIMM is available. Mixed memory is neither tested nor supported. Non-ECC memory is not tested and is not recommended for use in a server environment. The location of DIMM sockets on the motherboard is shown in Figure 17: Intel® Server System SR1680MV Service Guide 17
  • Intel SR1680MV | Service Guide - Page 38
    Figure 17. Location of System Memories There are 18 DIMMs on the motherboard to support processor 1 and processor 2. The DIMM sequence of 18 DIMM sockets is respectively shown in Figure 18. Figure 18. DIMM Socket Location 18 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 39
    each memory access is a 128-bit data access that spans Channel 0 and Channel 1. Lockstep Channel mode is the only RAS mode that supports x8 processor 1 and 2. The last column in tables marks DIMM installation under Mirrored Channel Mode for your reference. Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 40
    Channels of Processor 2 DIMM part number be used within one motherboard. For Unbuffered DIMMs or Quad-rank Registered DIMMs, only configuration 1~6 could be supported. Optional Note: For other Registered DIMMs, configuration 1~9 could be supported. 20 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 41
    DIMMs, complete the following steps: 1. Make sure the server is not turned on or connected to the AC power. To power off the server, see "Power Off". 2. Remove the chassis cover. To remove the a DIMM socket by pressing the retaining clips outward. Intel® Server System SR1680MV Service Guide 21
  • Intel SR1680MV | Service Guide - Page 42
    Figure 20. Pressing the Retaining Clips Outward 2. Align the notch on the DIMM to the break on the socket. Carefully insert the DIMM into the socket until the retaining clips snap back in place. Figure 21. Inserting the DIMM into the Socket 22 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 43
    cage module, avoid touching any metal leads or connectors. Removing the Server Board Cage Module 1. Slide the locking latch along the direction of the arrow. 2. The cage locking lever springs open by itself. Figure 23. Releasing the Locking Latch Intel® Server System SR1680MV Service Guide 23
  • Intel SR1680MV | Service Guide - Page 44
    of the arrow to remove the module. Figure 24. Pull the Locking Lever to Remove the Server Board Cage Module Installing the Server Board Cage Module Reverse the "Removing the Server Board Cage Module" steps to install the server board cage module. 24 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 45
    to the AC power. To power off the server, see "Power Off". 2. Disconnect all necessary cable connections. 3. When removing and installing I/O board cage module, keep the handle of the power supply in the horizontal direction to avoid damage on it. Intel® Server System SR1680MV Service Guide 25
  • Intel SR1680MV | Service Guide - Page 46
    to Remove the Left I/O Board Cage Module Installing the Left I/O Board Cage Module Reverse the above steps to install the left I/O board cage module. 26 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 47
    in the horizontal direction. 2. Press the retaining clip on the left side of the power supply along the direction of the arrow. 3. Simultaneously pull out the power supply by using its handle. (The power supply takes considerable force to remove.) Intel® Server System SR1680MV Service Guide 27
  • Intel SR1680MV | Service Guide - Page 48
    . Figure 31. Power Distribution Board Note: Before you remove or install the power distribution board, complete the following steps: 1. Make sure the server is not turned on or connected to the AC power. To power off the server, see "Power Off". 28 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 49
    Board 1. Lift the power distribution board from the chassis. Figure 32. Removing the Power Distribution Board Installing the Power Distribution Board Reverse the "Removing the Power Distribution Board" steps to install the power distribution board. Intel® Server System SR1680MV Service Guide 29
  • Intel SR1680MV | Service Guide - Page 50
    SATA HDD The sever supports up to four 2.5-inch pluggable SATA HDDs, two on each server board module. Four HDDs : 1. Make sure the server is not turned on or connected to the AC power. To power off the server, see "Power Off". 2. Disconnect all . 30 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 51
    35. Pull the Locking Lever to Remove the HDD Carrier 5. Loosen and remove the four securing screws. 6. Lift the HDD up from the HDD carrier. Intel® Server System SR1680MV Service Guide 31
  • Intel SR1680MV | Service Guide - Page 52
    2.5-inch pluggable SATA HDD. 2.5-inch Pluggable HDD Backplane Each server board module supports one 2.5-inch pluggable HDD backplane; two HDD backplanes share HDD backplane on the server chassis: Figure 37. 2.5-inch Pluggable HDD Backplane Location 32 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 53
    installation procedures. For your reference, this section provides the steps for replacing one system fan on the right I/O board cage module as an example. The following figure shows the location of the system fan on the right I/O board cage module: Intel® Server System SR1680MV Service Guide 33
  • Intel SR1680MV | Service Guide - Page 54
    remove the cover, see "Left and Right I/O Board Cage Modules". 3. Disconnect all necessary cable connections. Removing a System Fan 1. Lift the system fan up from the I/O board cage module. Figure 40. Lift a System Fan Up from I/O Board Cage Module 34 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 55
    System Fan" steps to install the system fan. Air Duct Note: Before you remove or install the air duct, complete the following steps: 1. Make sure the server is not turned on or connected to the AC power. To power off the server, see "Power I/O board. Intel® Server System SR1680MV Service Guide 35
  • Intel SR1680MV | Service Guide - Page 56
    right I/O board cage modules each include one PCI-E cage. Two PCI-E cages on the server share the same removal and installation : 1. Make sure the server is not turned on or connected to the AC power. To power off the server, see "Power Off". 2. Remove the Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 57
    slot cover to the right position along the arrow. 5. Secure the slot cover to the PCI-E cage with one screw as shown in Figure 45. Intel® Server System SR1680MV Service Guide 37
  • Intel SR1680MV | Service Guide - Page 58
    section takes the steps of removing and installing 10GB IO card as example. Figure 47 shows the location of the 10 GB IO card. 38 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 59
    following steps: 1. Make sure the server is not turned on or connected to the AC power. To power off the server, see "Power Off". 2. Remove the left and right Separate guide pins of the module from the holes on the IO Board and lift the module upward. Intel® Server System SR1680MV Service Guide 39
  • Intel SR1680MV | Service Guide - Page 60
    Figure 49. Lifting the Module Upward from the IO Board 2. Remove the I/O Expansion module out of the IO board module. Figure 50. Removing the Module Upward from the IO Board 40 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 61
    Installing the IO Expansion Module Reverse the steps in the "Removing the IO Expansion Module"to install the IO Expansion module. Intel® Server System SR1680MV Service Guide 41
  • Intel SR1680MV | Service Guide - Page 62
    42 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 63
    3 Cable Connections Connectors and Pin 1 Locations Figure 51 shows the different locations of the connectors and their pin 1 locations, which can help you connect the cables. Figure 51. Locations of Connectors and Pin 1 on Server Board Intel® Server System SR1680MV Service Guide 43
  • Intel SR1680MV | Service Guide - Page 64
    section contains figures showing cable locations and descriptions of the connection procedures. System Fan Cables System Fan Cables Connect the 6-pin system fan cables from the system fans to the corresponding system fan connectors on the I/O board. 44 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 65
    Figure 53. Connecting the System Fan Cables Intel® Server System SR1680MV Service Guide 45
  • Intel SR1680MV | Service Guide - Page 66
    46 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 67
    ) 4. SATA Power Connector (J47) 6. Server board SATA3 Connector (J31) 8. DIMM Socket Group (J7, J8, J9, J10, J11, J12, J13, J14, J15) 10. Server board Power Connector3 (J4) 12. Server board Power Connector2 (J3) 14. Processor 2 (CPU 2) 16. MISC Jumper Intel® Server System SR1680MV Service Guide 47
  • Intel SR1680MV | Service Guide - Page 68
    17. Front UID LED 19. Power Button 21. Power LED 23. NIC LED 25. Serial Port 18. Front UID Button 20. System Health LED 22. Front USB Ports 24. HDD LED 26. VGA Port 48 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 69
    Left J5 Right J5 J6 J7 J7 J8 J3 J3 CR6 CR6 Description Location 2. IO Board IO Connector 4. System Fan2 Connectors 6. PCI-E 2 Connectors 8. IO Board NIC Connectors 10. Rear UID Buttons Left J10 J8 J2 J4 SW2 Right J10 J9 J2 J4 SW2 Intel® Server System SR1680MV Service Guide 49
  • Intel SR1680MV | Service Guide - Page 70
    Connector and Component Locations of NIC Board Figure 56. Connectors and Component Locations of NIC Board 1. Connector 3. Rear NIC1 Port 2. Rear NIC2 Port 50 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 71
    Panel Figure 57. Connectors and Component Locations of Front Panel 1. Front VGA Port 3. NIC LED 5. System Health LED 7. Front UID Button 9. Power LED 11. SATA LED 2. Front Serial Port 4. Front USB Port 6. Power Button 8. UID LED 10. Front USB Port Intel® Server System SR1680MV Service Guide 51
  • Intel SR1680MV | Service Guide - Page 72
    10 GB IO Card (Optional Daughter Card) Figure 58. Connectors and Components of 10 GB IO Card 1. PCI-E 2 Connector 3. 10 GB IO Port1 2. PCI-E 1 Connector 4. 10 GB IO Port2 52 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 73
    InfiniBand Card (Optional Daughter Card) Figure 59. Connectors and Components of InfiniBand Card 1. PCI-E 2 Connector 3. InfiniBand CX4 Port 2. PCI-E 1 Connector Intel® Server System SR1680MV Service Guide 53
  • Intel SR1680MV | Service Guide - Page 74
    LED (CR4) 3. HDD 1 Active LED (CR1) 5. HDD 0 Active LED (CR3) 7. Golden Fingers (J1) 2. HDD 1 Fail LED (CR2) 4. SATA 1 Connector (J3) 6. SATA 0 HDD Connector (J2) 54 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 75
    Power Supply Slot (J1) 3. Power Connector 2 (J4) 5. Power Connector 4 (J2) 2. Power Connector 1 (J5) 4. Power Connector 3 (J3) The server board involves two system of two system maintenance jumpers on the motherboard is shown in the following figure: Intel® Server System SR1680MV Service Guide 55
  • Intel SR1680MV | Service Guide - Page 76
    Figure 62. Location of MISC Jumper Jumper A B C D E F G H Function Reserved Clear BMC Password Reserved Reserved Reserved Reserved Reserved Reserved 56 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 77
    Figure 63. Location of ICH Function Jumper Jumper A B C D E Function Clear CMOS Clear Password Recovery RWH BIOS Protect RTC Reset Intel® Server System SR1680MV Service Guide 57
  • Intel SR1680MV | Service Guide - Page 78
    58 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 79
    commands supported by the setup utility. Located at the top of the screen. Displays the various major menu selections available to the user. The Server Setup utility major menus are: Main Menu, Advanced Menu, Boot Menu, Security Menu, and Exit Menu. Intel® Server System SR1680MV Service Guide 59
  • Intel SR1680MV | Service Guide - Page 80
    of the right side of the screen. Entering the BIOS Setup Utility During the BIOS POST operation, the user is prompted to use the field is made inaccessible. The Keyboard Command Bar supports the following: Key Enter Table 6. Keyboard Command Bar Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 81
    ESC key is pressed in any major menu, the exit confirmation window is displayed and the user is asked whether changes can be and the Enter key is pressed, Setup is exited and the BIOS continues with POST. The up arrow is used to select the previous Intel® Server System SR1680MV Service Guide 61
  • Intel SR1680MV | Service Guide - Page 82
    to where they were before F10 was pressed without affecting any existing values. BIOS Setup Utility Menu The Setup Utility menu bar displays the five primary menu Settings with * in tables are BIOS Setup defaults of BIOS Setup Utility Menu. 62 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 83
    System date Current date Table 8. Main Menu Fields Description User [ENTER], [TAB] or [SHIFT-TAB] to select a field. Use [+] or [-] to configure system Time. User [ENTER], [TAB] or [SHIFT-TAB] to select a field. Use [+] or [-] to configure system Time. Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 84
    • USB Configuration • PCI Configuration • IPMI Configuration • Remote Access Configuration Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit V02.67 © Copyright 1985-2009, American Megatrends, Inc. 64 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 85
    Enabled* Transition the links to the specified speed when transitioning the links to full-speed. (if supported by all components). For UP platforms, leave it enabled. For DP/MP servers, it may use to tune performance to the specific application. Intel® Server System SR1680MV Service Guide 65
  • Intel SR1680MV | Service Guide - Page 86
    : A full reset is required to change the setting. When disabled, force the XD feature flag to always return 0. Number of cores to enable in each processor package. Disable: Disable GV3 Enable: Enable GV3 CState: CPU idle is set to C2/C3/C4 66 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 87
    Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit V02.67 © Copyright 1985-2009, American Megatrends, Inc. Intel® Server System SR1680MV Service Guide 67
  • Intel SR1680MV | Service Guide - Page 88
    Table 13. SATA Configuration Submenu2 BIOS Setup Utility Main Advanced SATA Configuration [Enhanced] Configure SATA AS • Primary IDE Master • Primary IDE Slave • F10 Save and Exit ESC Exit V02.67 © Copyright 1985-2009, American Megatrends, Inc. 68 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 89
    Table 14. SATA Configuration Submenu3 BIOS Setup Utility Main Advanced Boot Security Exit Configure SATA AS • SATA PORT 1 [RAID] :[Not Detected] Configure the IDE device(s). :[Not Detected] :[ © Copyright 1985-2009, American Megatrends, Inc. Intel® Server System SR1680MV Service Guide 69
  • Intel SR1680MV | Service Guide - Page 90
    Table 15. SATA Configuration Submenu4 BIOS Setup Utility Main Advanced Boot Security Exit SATA Configuration [Enhanced] Configure SATA AS • AHCI PORT1 • AHCI PORT2 F10 Save and Exit ESC Exit V02.67 © Copyright 1985-2009, American Megatrends, Inc. 70 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 91
    35* Options Disabled Compatible Enhanced Options IDE RAID AHCI Options Enable Disabled Disable/Enable device write protection. This will effective only if device is accessed through BIOS. Select the time out value for detecting ATA/ATAPI device(s). Intel® Server System SR1680MV Service Guide 71
  • Intel SR1680MV | Service Guide - Page 92
    Table 17. Primary/Secondary IDE Master/Slave BIOS Setup Utility Main Advanced Boot Security Exit Primary IDE Master Device Type Drive Write Cache Block General Help F10 Save and Exit ESC Exit V02.67 © Copyright 1985-2009, American Megatrends, Inc. 72 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 93
    from and to the device Occurs multiple sectors at a time if the device supports it. Select PIO Mode. Select DMA Mode. Auto: Auto detected. S.M.A.R.T. stands for Self-Monitoring, Analysis and Reporting Technology. Enable/Disable 32-bit Data Transfer. Intel® Server System SR1680MV Service Guide 73
  • Intel SR1680MV | Service Guide - Page 94
    Super IO Chipset Submenu Table 19. Super IO Chipset Submenu BIOS Setup Utility Main Advanced Boot Security Exit Configure PILOT Super IO Chipset Serial Port Help F10 Save and Exit ESC Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. 74 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 95
    Table 20. SATA Configuration Submenu Fields Menu Fields Settings Description Advanced/Super IO Configuration Serial Port Address Disabled 3F8/IRQ4 2F8/IRQ3 3F8/IRQ4 2F8/IRQ3 Allows BIOS to select Serial Port1 Base Address. Intel® Server System SR1680MV Service Guide 75
  • Intel SR1680MV | Service Guide - Page 96
    22. USB Configuration Submenu Fields Menu Fields Settings Description Advanced/USB Configuration Legacy USB Support Disabled Enabled* Auto Enables support for legacy USB. AUTO option disables legacy support if no USB devices are connected. 76 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 97
    systems without EHCI hand-off support. The EHCI ownership change should claim by EHCI driver. A dummy FDD device is created that will be associated with the hotplugged FDD later. Auto option creates this dummy device only if there is no FDD present. Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 98
    ] BIOS Setup Utility Boot Security Exit Configure the USB Mass Storage Device Classes. Select Screen Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. 78 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 99
    Floppy and remaining as hard drive. Forced FDD option can be used to force a HDD-formatted drive to boot as FDD (for example, a zip drive). Intel® Server System SR1680MV Service Guide 79
  • Intel SR1680MV | Service Guide - Page 100
    Configuration Submenu BIOS Setup Utility Main Advanced Boo Security Exit t PCI Express Configuration Active State Power-Management [Disabled] Configure PCI Express* support. Select Enable/Disable PCI Express* L0s and L1 link power states. 80 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 101
    Utility Boo Security Exit t IPMI configuration including server monitoring and event log. Select Screen Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. Intel® Server System SR1680MV Service Guide 81
  • Intel SR1680MV | Service Guide - Page 102
    Disable PEF No* Yes* Restore on AC Power Loss Power Off* Power On Last State Yes or No to disable PEF in BMC after exiting SETUP. It only affects once and then will be changed to [No] when [Yes] is selected. Options Power Off Power On Last State 82 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 103
    Screen Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. Intel® Server System SR1680MV Service Guide 83
  • Intel SR1680MV | Service Guide - Page 104
    Access Configuration Submenu Table 30. Remote Access Configuration Submenu Main Advanced BIOS Setup Utility Boot Security Exit Remote Access [Enabled] Configure Remote Access Remote Access Disabled* Enabled Select Remote Access type. 84 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 105
    DVD Drives BIOS Setup Utility Boot Security Exit Configure Settings during System Boot. Select Screen Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. Intel® Server System SR1680MV Service Guide 85
  • Intel SR1680MV | Service Guide - Page 106
    Boot Quiet Boot Disabled Enabled* Disabled* Enabled Allows BIOS to skip certain tests while booting. This will decrease the time needed to boot the system. Disabled: Displays normal POST messages. Enabled: Displays OEM logo instead of POST messages. 86 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 107
    AddOn ROM Display Mode Bootup Num Lock Interrupt 19 Capture Settings Force BIOS* Keep Current Off On* Disabled* Enabled Description Set display mode for Option ROM. Select Power-on state for Numlock. Enabled: Allows option ROMs to trap interrupt 19. Intel® Server System SR1680MV Service Guide 87
  • Intel SR1680MV | Service Guide - Page 108
    1st Boot Device [Network:IBA GE Slo] 2nd Boot Device [Network:IBA GE Slo] BIOS Setup Utility Boot Security Exit Specifies the boot sequence from the available devices. A device enclosed Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. 88 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 109
    Screen Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. Intel® Server System SR1680MV Service Guide 89
  • Intel SR1680MV | Service Guide - Page 110
    Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. 90 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 111
    Computing Power & Reset Switches Inhibit [Disabled] NMI Control Switch Inhibit [Disabled] Select Screen Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 112
    Setup* Always Boot Sector Virus Protection Disabled* Enabled Power & Reset Switches Inhibit Disabled* Enabled NMI Control Virus Protection. Disable the front panel power and reset switch. Enable/Disable NMI control for the front panel NMI button. 92 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 113
    BIOS Setup Utility Boot Security Exit Enable/Disable TPM TCG (TPM 1.1/ 1.2) support in BIOS. Select Screen Select Screen + - Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 114
    Table 41. Trusted Computing Submenu Fields Menu Fields Settings Description Advanced/Boot Settings Configuration TCG/TPM SUPPORT No* Yes Enable/Disable TPM TCG (TPM 1.1/1.2) support in BIOS. 94 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 115
    Chipset Settings Save Changes and Exit Discard Changes and Exit BIOS Setup Utility Boot Security Exit Exit system setup after saving the changes. Load Optimal Defaults Load Failsafe ESC Exit V02.61 © Copyright 1985-2006, American Megatrends, Inc. Intel® Server System SR1680MV Service Guide 95
  • Intel SR1680MV | Service Guide - Page 116
    rename it to AMIBOOT.ROM. Recovery method: 1. Turn on the system configuration jumper J30-C (BIOS Recovery) to invoke recovery function during POST. 2. Plug USB Disk on Key (or Floppy/CD-ROM). 3. Power on computer wait for recovery process complete. 96 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 117
    4. Unplug USB Disk on Key (or Floppy/CD-ROM) & Turn off the Recovery Jumper. 5. Restart system & load BIOS default. Intel® Server System SR1680MV Service Guide 97
  • Intel SR1680MV | Service Guide - Page 118
    98 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 119
    Go to the Advanced menu, select SATA Configuration and press . 3. Set the Configure SATA AS as option to [RAID]. 4. Save your changes and then exit BIOS Setup. For more information, refer to the Intel® Matrix Storage Manager 8.x User's Manual. Intel® Server System SR1680MV Service Guide 99
  • Intel SR1680MV | Service Guide - Page 120
    100 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 121
    Slotted Point Screwdriver There are seven spring screw holes in rail to secure each spring. Spring secured in different spring screw holes can fit to different depths for racks. The locations and the adapt depth for racks are shown below: Intel® Server System SR1680MV Service Guide 101
  • Intel SR1680MV | Service Guide - Page 122
    rack must provide sufficient airflow to the system to maintain proper cooling. Procedure: 1. Put the tighten screws2 into the washers. 2. Install the tighten screws2 with washers into the hole of the rails (Recommended Driver Force: 5 lb-in). 102 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 123
    in the racks. 4. Secure rails to the front and back of the racks using tighten screws1 and align pin (Recommended Driver Force 7 lb-in). Figure 67. Secure the Rail to Racks 5. Slide the server into the racks. Figure 68. Slide The Server Into Racks Intel® Server System SR1680MV Service Guide 103
  • Intel SR1680MV | Service Guide - Page 124
    70. Secure The Server Ears To Racks Note: The system is not fixed to the rack or mounted to the rails. You must adequately support the system rack during installation and removal, or the risk of personal injury or damage to the equipment happens. 104 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 125
    on the baseboard System BIOS Version: Intel® Remote Management Module Firmware Version (if applicable): Intel® Management Module BMC Revision (if applicable): BMC/mBMC Version: FRU/SDR Version: HSC Version: Has the latest BIOS been tried? (Yes/No): Intel® Server System SR1680MV Service Guide 105
  • Intel SR1680MV | Service Guide - Page 126
    Processor 1 Processor 2 Processor 3 Processor 4 Type Speed sSpec Thermal Solution Thermal solution (Heatsink) examples: (1U, Passive w/air ducting, Active w/fan, etc Memory: Manufacturer Part Number DRAM Part Number On Intel tested list? 106 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 127
    , Microsoft* Windows* Server 2003, Service pack 1, OEM CD): Manufacturer: Version: Language version (English, Arabic, Chinese (Simplified)): Service Pack Level or Kernel Revision: Distribution (OEM/Retail Intel® RAID Controller: (Example SRCU42E) Intel® Server System SR1680MV Service Guide 107
  • Intel SR1680MV | Service Guide - Page 128
    RAID driver been tried? (Yes/No): RAID volumes configuration (disks & RAID level): RAID volume use (Boot device/Data Volume): Is BBU (Battery Backup Unit) installed? (Yes/No): BBU part number Detailed description of issue: Troubleshooting tried: 108 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 129
    provide a brief description below. Have you returned systems or components to your place of purchase because of this issue? If yes, please provide a brief description below. *All other brands and names are property of their respective owners. Intel® Server System SR1680MV Service Guide 109
  • Intel SR1680MV | Service Guide - Page 130
    110 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 131
    installation or configuration. Hardware failure is a less frequent cause. First Steps Checklist • Is AC power available at the wall outlet? • Are the power supplies plugged in? Check the AC cable(s) on the back of the chassis and at the AC source. Intel® Server System SR1680MV Service Guide 111
  • Intel SR1680MV | Service Guide - Page 132
    display monitor and keyboard are correctly connected to the system. Turn on the video monitor. Set its brightness and contrast controls to at least two thirds of their maximum ranges (see the documentation supplied with your video display monitor). 112 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 133
    server AC power cord into the power supply? • Remove all add-in cards and see if the system boots. If successful, add the cards back in one at a time with a reboot between each addition. • Make sure the memory DIMMs comply with the system requirements. Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 134
    and contrast controls properly adjusted on the video monitor? See the manufacturer's documentation. • Are the video monitor's signal and power cables properly installed? • Does this video monitor work correctly if plugged into a different system? 114 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 135
    mode as the network controller. • Make sure the correct networking software is installed. • If you are directly connecting two servers (without a hub), you will need a crossover cable. • Check the network controller LEDs next to the NIC connectors. Intel® Server System SR1680MV Service Guide 115
  • Intel SR1680MV | Service Guide - Page 136
    the cards one at a time, booting the system between each card addition, until the beeps again occur to reveal the malfunctioning card. Replace or reseat the system video add-in card. If on-board video is being used, the server board may be faulty. 116 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 137
    CPU 1 socket is empty. Reseat or replace the failed processor. In a two-processor system, make sure the processors are identical. Front-side bus select configuration error. DC power unexpectedly lost. Chipset control failure. Power control failure. Intel® Server System SR1680MV Service Guide 117
  • Intel SR1680MV | Service Guide - Page 138
    118 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 139
    5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. Intel® Server System SR1680MV Service Guide 119
  • Intel SR1680MV | Service Guide - Page 140
    telecommunication lines to your modem during an electrical storm. • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. 120 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 141
    Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Server System SR1680MV Service Guide 121
  • Intel SR1680MV | Service Guide - Page 142
    anzubringen: 1. Vergewissern Sie sich, daß Sie keine Werkzeuge oder Teile im Innern des Systems zurückgelassen haben. 2. Überprüfen Sie alle Kabel, Zusatzkarten und andere Komponenten auf Batterien den Anweisungen des Herstellers entsprechend. 122 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 143
    Français Das System wurde für den Betrieb in einer normalen Büroumgebung entwickelt. Der Standort sollte: • "sauber und staubfrei sein (Hausstaub le système est branché doit se situer à proximité de l'équipement et être facilement accessible. Intel® Server System SR1680MV Service Guide 123
  • Intel SR1680MV | Service Guide - Page 144
    a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. 124 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 145
    type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. alimentación de corriente alterna que tenga el producto Intel® Server System SR1680MV Service Guide 125
  • Intel SR1680MV | Service Guide - Page 146
    las tapas del sistema. Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de los cables externos y los cables de alimentación CA al sistema. 126 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 147
    diseñado para funcionar en un entorno de trabajo normal. Escoja un lugar: • "Limpio y libre de partículas en suspensión (salvo el polvo normal). • "Bien ventilado y alejado de fuentes de calor, che il prodotto disponga di più fonti di alimentazione. Intel® Server System SR1680MV Service Guide 127
  • Intel SR1680MV | Service Guide - Page 148
    e chiudere a chiave il lucchetto sul retro del sistema per impedire l'accesso non autorizzato al sistema. 5. Ricollegare tutti i cavi esterni e le prolunghe AC del sistema. 128 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 149
    tipo. Scegliere una postazione che sia: • "Pulita e libera da particelle in sospensione (a parte la normale polvere presente nell'ambiente). • "Ben ventilata e lontana da fonti di calore rappresentano il mezzo principale di scollegamento del sistema. Intel® Server System SR1680MV Service Guide 129
  • Intel SR1680MV | Service Guide - Page 150
    130 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 151
    server should be integrated and serviced only by technically qualified persons. You must adhere to the guidelines in this guide and the assembly instructions in your server manuals in serious injury or death if safety instructions are not followed. Intel® Server System SR1680MV Service Guide 131
  • Intel SR1680MV | Service Guide - Page 152
    and away from sources of heat including direct sunlight and radiators. • Away power supply cord(s), because they serve as the product's main power disconnect. Equipment Handling Practices Reduce the risk of personal injury or equipment damage: 132 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 153
    . • Retain all screws or other fasteners when removing access cover(s). Upon completion of accessing inside the product, refasten access cover with original screws or fasteners. Intel® Server System SR1680MV Service Guide 133
  • Intel SR1680MV | Service Guide - Page 154
    power supply, unplug the power cord to the power supply being replaced before removing the power supply from the chassis. Caution: If the compute module has been running, any installed processor boards, and other parts. We recommend that you problems. 134 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 155
    or parts inside the chassis • Check that cables, add-in boards, and other components are properly installed. • Attach the covers to the chassis according to the product instructions. Laser Produktbestimmungen verstoßen, die im Verkaufsland gelten. Intel® Server System SR1680MV Service Guide 135
  • Intel SR1680MV | Service Guide - Page 156
    Alarmsysteme oder Prüfgeräte) kann u. U. weitere Tests erfordern. Standortauswahl Das System ist für den Betrieb innerhalb normaler Büroumgebungen geeignet. Wählen Sie einen Standort, . • Nicht in der Nähe von Vibrations- oder Erschütterungsquellen. 136 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 157
    Geräte erzeugt werden. • In gewittergefährdeten Gebieten sollten Sie das System an einen Überspannungsschutz anschließen und bei einem Gewitter die Telekommunikationskabel zum lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Server System SR1680MV Service Guide 137
  • Intel SR1680MV | Service Guide - Page 158
    Arbeiten im Netzteil aus. Das Netzteil enthält keine für den Benutzer wartungsbedürftigen Teile. Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. 138 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 159
    dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 160
    Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. 140 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 161
    Ce document s'applique aux cartes serveur Intel®, au châssis de serveur Intel®(sur pieds et sur rack) et aux périphériques installés. Vous devez suivre les informations de ce guide et les instructions d'assemblage des manuels de serveur pour vé . Intel® Server System SR1680MV Service Guide 141
  • Intel SR1680MV | Service Guide - Page 162
    assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. 142 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 163
    ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage en cours de remplacement avant de retirer le bloc du serveur. Intel® Server System SR1680MV Service Guide 143
  • Intel SR1680MV | Service Guide - Page 164
    panneaux du châssis sont en place. L'utilisation du système sans les panneaux peut endommager les composants système. Pour installer les panneaux : 144 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 165
    panneaux au châssis en suivant les instructions du produit. Périphériques laser tarjetas de servidor de Intel®, los gabinetes de servidor de Intel® (montaje en rack y en pedestal) instrucciones de montaje de los manuales del servidor para asegurar y Intel® Server System SR1680MV Service Guide 145
  • Intel SR1680MV | Service Guide - Page 166
    eléctricas, se recomienda que conecte el servidor a un supresor de sobretensiones y desconecte las líneas de telecomunicaciones al módem durante una tormenta eléctrica. 146 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 167
    conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use fuente de alimentación. Dentro de la fuente de alimentación Intel® Server System SR1680MV Service Guide 147
  • Intel SR1680MV | Service Guide - Page 168
    el sistema se enfríe antes de abrir las cubiertas. Para que no llegue a tocar los componentes que estén calientes cuando esté realizando una instalación 148 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 169
    las cubiertas: • Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema. • Compruebe que los cables, tarjetas adicionales y otros componentes están instalados correctamente. Intel® Server System SR1680MV Service Guide 149
  • Intel SR1680MV | Service Guide - Page 170
    de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. 150 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 171
    简体中文 Intel Intel Intel Web UL Intel® Server System SR1680MV Service Guide 151
  • Intel SR1680MV | Service Guide - Page 172
    ITE ITE 场地选择 5V 152 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 173
    Intel® Server System SR1680MV Service Guide 153
  • Intel SR1680MV | Service Guide - Page 174
    ESD) ESD ESD ESD ESD 154 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 175
    其他危险 替换电池 Intel® Server System SR1680MV Service Guide 155
  • Intel SR1680MV | Service Guide - Page 176
    156 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 177
    . The suitability of this product for other product categories and environments (such as: medical, industrial, telecommunications, NEBS, residential, alarm systems, test equipment, etc.), other than an ITE application, may require further evaluation. Intel® Server System SR1680MV Service Guide 157
  • Intel SR1680MV | Service Guide - Page 178
    (Europe) • IEC60950 (International) • CB Certificate & Report, IEC60950 (report to include all country national deviations) • GS Certification (Germany) • GOST R 50377-92 (Russia) • Ukraine Certification (Ukraine) • KCC Certification (EMI) (Korea) 158 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 179
    (Taiwan) • GOST R Certification / Certification (Russia) • KCC Certification (Korea) • IRAM Certification (Argentina) • Ecology Declaration (International) • China RoHS Environmental Friendly Use Period • Packaging & Product Recycling Marks Intel® Server System SR1680MV Service Guide 159
  • Intel SR1680MV | Service Guide - Page 180
    guide. Table 50. Product Regulatory Compliance Markings Regulatory Compliance Country Marking IRAM Mark Argentina Ctick Mark Australia / NZ N232 EMC Marking CE Mark GS Mark Canada Europe CANADA ICES-003 CLASS A Germany VCCI Mark Japan 160 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 181
    Table 50. Product Regulatory Compliance Markings Regulatory Compliance Country Marking KCC Mark Korea GOST Mark Russia BSMI Mark Taiwan CPU-SR1680 (A) MO04 R33025 UL Mark USA / Canada Intel® Server System SR1680MV Service Guide 161
  • Intel SR1680MV | Service Guide - Page 182
    FCC Mark USA (FCC Mark) This device complies with Part 15 of the FCC Rules. Operation of this device and (2) This device must accept interference receive, including interference that may cause undesired operation. Country of earth grounded outlet." 162 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 183
    Power Cord Multiple Power Cord English: This unit has more than one power supply cord. To reduce the risk of electrical shock, disconnect (2) two power supply cords before servicing Instandhaltung. WEEE Marking WEEE Marking China RoHS China RoHS Intel® Server System SR1680MV Service Guide 163
  • Intel SR1680MV | Service Guide - Page 184
    / perchlorate This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material. 164 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 185
    . If the server power cord is plugged into a wall AC outlet, the safety ground conductor in the power cord provides proper grounding only for the server. You must provide additional, proper grounding for the rack and other devices installed in it. Intel® Server System SR1680MV Service Guide 165
  • Intel SR1680MV | Service Guide - Page 186
    part of each host equipment rack and must be incorporated in the field wiring between the DC source and the server. The branch circuit protection shall be rated minimum 75Vdc, 10 A maximum per feed pair. If the DC power system for the equipment rack 166 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 187
    connectors that plug into the AC receptacle on the server must be an approved IEC (International Electrotechnical Commission) 320, sheet C13, type female connector. • Cord length and flexibility: Cords must be less than 4.5 meters (14.76 feet) long. Intel® Server System SR1680MV Service Guide 167
  • Intel SR1680MV | Service Guide - Page 188
    any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young result in interference to radio and TV reception. 168 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 189
    . If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. Intel® Server System SR1680MV Service Guide 169
  • Intel SR1680MV | Service Guide - Page 190
    other components will void the UL listing and other product certifications and approvals. Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder 170 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 191
    Storage Devices: must be UL recognized or UL listed accessory and TUV or VDE Certificationd. Maximum power rating of any one device is 19 watts. Total server configuration is not to exceed the maximum loading conditions of the power supply. Intel® Server System SR1680MV Service Guide 171
  • Intel SR1680MV | Service Guide - Page 192
    172 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 193
    Appendix F: Warranty To obtain warranty service for this Product, visit the following Intel website: http://support.intel.com/support/motherboards/server/sb/CS-010807.htm Intel® Server System SR1680MV Service Guide 173
  • Intel SR1680MV | Service Guide - Page 194
    174 Intel® Server System SR1680MV Service Guide
  • Intel SR1680MV | Service Guide - Page 195
    -the-clock 24x7 technical phone support on Intel® server boards, server chassis, server RAID controller cards, and Intel® Server Management at http://www.intel.com/reseller/. You will need to log in to the Reseller site to obtain the 24x7 number. Intel® Server System SR1680MV Service Guide 175
  • Intel SR1680MV | Service Guide - Page 196
    176 Intel® Server System SR1680MV Service Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

Intel
®
Server System SR1680MV
Service Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products
Intel Order Number E74835-005