Intel SR2500ALBRPR User Guide

Intel SR2500ALBRPR - Server System - 0 MB RAM Manual

Intel SR2500ALBRPR manual content summary:

  • Intel SR2500ALBRPR | User Guide - Page 1
    Intel® Server System SR2500AL User's Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number D31969-004
  • Intel SR2500ALBRPR | User Guide - Page 2
    are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2006-2007, Intel Corporation. All Rights Reserved ii Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 3
    statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Deployment Assistant CD and/or at http://support.intel.com/support/motherboards/ server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zun
  • Intel SR2500ALBRPR | User Guide - Page 4
    http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的 Intel Server Boards and Server Chassis Safety Information(《Intel iv Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 5
    surface on your server when handling parts. ESD and handling problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 6
    vi Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 7
    SR2500ALLX and/or the Intel® Server System SR2500ALBRP. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system. This document provides reference information, feature information, and step by step instructions on how to add
  • Intel SR2500ALBRPR | User Guide - Page 8
    Intel® Server Board S5000PAL User's Guide. There are two versions of this server system: the Intel® Server System SR2500ALLX/ SR2500ALLXR (SAS/SATA version) and the Intel® Server System SR2500ALBRP/ SR2500ALBRPR (SATA only version). The contents of each server system are listed below. Intel® Server
  • Intel SR2500ALBRPR | User Guide - Page 9
    Intel® Server System SR2500ALBRP/SR2500ALBRPR Contents Your Intel® Server System SR2500ALBRP/SR2500ALBRPR ships with the following items: • Intel® Server Board S5000PAL, installed in the server system • One 750 W power supply module, installed in the server system • A box of hardware components,
  • Intel SR2500ALBRPR | User Guide - Page 10
    x Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 11
    viii Intel® Server System SR2500ALLX/SR2500ALLXR Contents viii Intel® Server System SR2500ALBRP/SR2500ALBRPR Contents ix Chapter 1: Server System References 1 Chapter 2: Server System Features 3 Chassis Component Identification 6 Internal Components ...6 Configuration Jumpers ...9 RAID Support
  • Intel SR2500ALBRPR | User Guide - Page 12
    64 Installing the I/O Expansion Module(s 66 Removing the I/O Expansion Module(s 67 Installing the Intel® RMM and Intel® RMM NIC 68 Removing the Intel® RMM and Intel® RMM NIC 70 Replacing the Mid-plane Board 71 Removing the Mid-plane Board 71 xii Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 13
    105 Appendix A: Technical Reference 107 Cable Routing ...107 Fan Connections ...108 750W Single Power Supply Input Voltages 109 750W Single Power Supply Output Voltages 109 System Environmental Specifications 110 Appendix B: Troubleshooting 111 Intel® Server System SR2500AL User's Guide xiii
  • Intel SR2500ALBRPR | User Guide - Page 14
    not Recognized under Device Manager (Microsoft* Windows* Operating System) ...119 Hard Drive(s) are not Recognized 119 Bootable CD-ROM Disk Is Not Detected 119 LED Information ...120 BIOS POST Beep Codes 120 Appendix C: Intel® Server Issue Report Form 123 Appendix D: LED Decoder 127 Appendix
  • Intel SR2500ALBRPR | User Guide - Page 15
    Appendix G: Warranty 149 Limited Warranty for Intel® Chassis Subassembly Products 149 Appendix H: Installation/Assembly Safety Instructions 153 English ...153 Deutsch ...155 Franç d'électricit 177 Avertissements sur le cordon d'alimentation 178 Intel® Server System SR2500AL User's Guide xv
  • Intel SR2500ALBRPR | User Guide - Page 16
    de alimentación 183 Advertencias el acceso al sistema 184 Advertencias sobre el montaje en bastidor 185 Descarga electrostática (ESD 185 Otros riesgos ...186 xvi Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 17
    17. Front Bezel Supporting the Intel® Local Control Panel 28 Figure 18. Removing the Front Bezel 29 Figure 19. Installing the Front Bezel 30 Figure 20. Removing the Server System Cover 31 Figure 21. Installing the Server System Cover 32 Figure 22. Removing the Processor Air Duct 33 Figure
  • Intel SR2500ALBRPR | User Guide - Page 18
    Redundant Fan Module 96 Figure 86. Installing a Fan into the Redundant Fan Module 96 Figure 87. Removing a Fan from the Fixed Fan Module 97 xviii Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 19
    -plane Board . 108 Figure 95. Connecting the Redundant Fan Power Cables to the Active Mid-plane Board.... 108 Figure 96. Diagnostic LED Placement Diagram 128 Intel® Server System SR2500AL User's Guide xix
  • Intel SR2500ALBRPR | User Guide - Page 20
    xx Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 21
    Table 1. Server System References 1 Table 2. Intel® Server System SR2500ALLX and/or the Intel® Server System SR2500ALBRP Feature Summary ...4 Table 3. NIC LED Descriptions 13 Table 4. Setup Menu Key Use 102 Table 5. Power Supply Output Capability 109 Table 6. System Environmental Specifications
  • Intel SR2500ALBRPR | User Guide - Page 22
    xxii Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 23
    Datasheet Found at: http://support.intel.com/support/motherboards/server/S5000PAL/ Intel® S5000 Server Board Family Server BIOS External Product Specification Found: available to order by contacting your Intel field representative; Intel reference number 19953 ESB2 Baseboard Management Controller
  • Intel SR2500ALBRPR | User Guide - Page 24
    virtual system tours and interactive repair information A link to the SMaRT Tool is available under "Other Resources" at the right side of the screen at http://support.intel.com/support/motherboards/server/chassis/ SR2500 Accessories or other Intel server products Spares and Configuration Guide
  • Intel SR2500ALBRPR | User Guide - Page 25
    describes the main features of the server system. This chapter provides illustrations of the product, a list of the server system features, and diagrams showing the location of important components and connections on the server system. AF000027 Figure 1. Intel® Integrated Server System SR2500AL
  • Intel SR2500ALBRPR | User Guide - Page 26
    SDRAM Intel® 82563EB dual port controller for 10/100/1000 Mbit/sec Ethernet LAN connectivity • One low profile riser slot supporting 1U or 2U PCI Express* riser cards • One full height riser slot supporting 1U or 2U PCI-X* and PCI Express* riser cards 4 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 27
    2. Intel® Server System SR2500ALLX and/or the Intel® Server System SR2500ALBRP Feature system fans (LX) • Two non-redundant fans in power supply • Two front panel USB ports • One internal USB header providing two USB ports Intel® System Management Software Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 28
    HDD or Tape Drive (optional) up to two power supply modules) F. Riser Card Assembly N. Hard Drive Bays G. Integrated Chassis Intrusion Switch O. Slimline Optical Drive Bay H. System Memory (below duct in illustration) Figure 2. ChassisComponents 6 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 29
    Server Board Connector and Component Locations A B C D EF GH I QQ J PP K OO L NN MM LL KK M JJ II N HH GG FF EE DD O CC BB P AA Z Q Y X W V U TS R TP02071 Intel® Server System SR2500AL User's Guide 7
  • Intel SR2500ALBRPR | User Guide - Page 30
    A. BIOS Bank Select Jumper D. POST Code Diagnostic LEDs G. System Identification LED Blue J. Serial B Configuration Jumper M. DIMM Sockets P. Processor 2 Socket S. Processor Fan 2 Header B. Intel® 6321ESB IO Controller Hub E. Intel® Adaptive Slot - Full Height H. Back Panel I/O Ports K. System Fan
  • Intel SR2500ALBRPR | User Guide - Page 31
    Normal Operation (Default) Jumper Name BIOS Select TP02087 Jumper Purpose If pins 1-2 are jumpered, the BIOS in the lower bank will be selected on the next reset. These pins should be jumpered on 2-3 for normal operation. Figure 4. BIOS Select Jumper Intel® Server System SR2500AL User's Guide 9
  • Intel SR2500ALBRPR | User Guide - Page 32
    normal operation. If pins 2-3 are jumpered, BMC Force Update Mode is enabled. These pins should be jumpered on 1-2 for normal operation. Figure 5. Recovery Jumpers 10 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 33
    Intel® Light Guided Diagnostics The server board contains diagnostic LEDs to help you identify failed and failing components, and to help you identify the server from among several servers. Except for the ID LED, the status LED, and the 5V standby LED, the LEDs turn on (amber) only if a failure
  • Intel SR2500ALBRPR | User Guide - Page 34
    Back Panel Connectors A B C D E F GH TP02081 A. Mouse C. Serial Port B (RJ45) E. NIC 2 (10/100/1000 Mb) G. USB Port 6 B. Keyboard D. NIC 1 (10/100/1000 Mb) F. Video H. USB Port 5 Figure 7. Back Panel Connectors 12 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 35
    the Intel® RAID Activation Key AXXRAKSW5 accessory to enable RAID 5, see the documentation that is included with the accessory kit. For information on configuring RAID, see the RAID software user's guide that is included on the Intel® Server Deployment Toolkit 2.0 CD. Intel® Server System SR2500AL
  • Intel SR2500ALBRPR | User Guide - Page 36
    server board, hot-swap backplane, and control panel. Two midplanes are offered for this system: a passive SATA (data cables required), and an active SAS/SATA RAID used in the Intel® Server System SR2500ALLX and/or the Intel® Server System SR2500ALBRP. 14 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 37
    A. RAID Battery Connector B. Mid-plane Power Connector C. Fan 6 Power D. Fan 5 Power E. Bridge Board Connector F. Fan 4 Power G. Fan 3 Power H. Fan 2 Power I. Fan 1 Power J. Backplane Connectors Figure 9. Active SAS/SATA Mid-Plane Components Intel® Server System SR2500AL User's Guide 15
  • Intel SR2500ALBRPR | User Guide - Page 38
    Backplane The backplane serves as an interface between the mid-plane board and the system drives. The following diagrams show the location for each connector found on the Connectors Figure 10. Hot-Swap SAS/SATA Backplane Components (Front View) . 16 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 39
    A BC D E AF000044 A. Flex Bay Power B. Flex Bay Data C. IDE Connector D. Backplane Power E. Data Connectors (one for the flex bay and one for the mid-plane) Figure 11. Hot-Swap SAS/SATA Backplane Components (Rear View) Intel® Server System SR2500AL User's Guide 17
  • Intel SR2500ALBRPR | User Guide - Page 40
    or the system is off. Solid blue indicates system identification is active. No light indicates system identification is not activated. Solid blue indicates system identification is active. No light indicates system identification is not activated. 18 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 41
    . No light indicates system identification is not activated. Continuous green light indicates the system has power applied to it. Blinking green indicates the system is in S1 sleep state. No light indicates the power is off / is in ACPI S4 or S5 state. Intel® Server System SR2500AL User's Guide 19
  • Intel SR2500ALBRPR | User Guide - Page 42
    . For instructions on installing either of the front bezels, see "Installing the Front Bezel". The order numbers for the bezels are: • ADWBEZBLACK: Black bezel for use with the standard control panel. • ADWLCDBEZEL: Black bezel for use with the Intel® Local Control Panel. 20 Intel® Server System
  • Intel SR2500ALBRPR | User Guide - Page 43
    Supply Module G. Server Management NIC (Optional) H. I/O Module (Optional) I. USB 6 J. USB 5 K. Video L. DB-9 Serial A Connector Knockout M. NIC 2 N. NIC 1 O. RJ45 Serial B Connector P. PS2* Keyboard and Mouse Connectors Figure 14. Server System Back Intel® Server System SR2500AL User's Guide 21
  • Intel SR2500ALBRPR | User Guide - Page 44
    temperature of 45C. Note: The Intel® Server System SR2500ALLX and/or the Intel® Server System SR2500ALBRP does not support all SAS or Serial ATA (SATA) hard drives. See "Server System References" for an Internet link to a list of supported hardware. 22 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 45
    ® Remote Management Module, see the instructions provided with the management module. Rack-Mounted Systems Your Intel® Server System SR2500ALLX and/or the Intel® Server System SR2500ALBRP can be mounted into a rack. Intel provides three options to mount this server into a rack. When installing the
  • Intel SR2500ALBRPR | User Guide - Page 46
    24 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 47
    are available to install the Intel® Server System SR2500ALLX and/or the Intel® Server System SR2500ALBRP in a rack. The options are the fixed bracket kit, the basic rail kit, and the tool-less rail kit. Only the tool-less rail kit allows you to service the server system while installed in a rack
  • Intel SR2500ALBRPR | User Guide - Page 48
    at least one screw. If possible, attach at two places. 21. In the same manner, attach the other rail assembly to the other side. 26 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 49
    to the server chassis) with the outer rail assemblies (attached to the rack). 9. Engage the matching rails and slide the server chassis into the rack until the two safety stops lock into position. 10. Depress the two safety locks (one on each side). Intel® Server System SR2500AL User's Guide 27
  • Intel SR2500ALBRPR | User Guide - Page 50
    is at the right. If you are installing a bezel on your server system, make sure you position it as shown. AF000154 Figure 16. Front Bezel Supporting the Standard Control Panel AF000153 Figure 17. Front Bezel Supporting the Intel® Local Control Panel 28 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 51
    Removing the Front Bezel Use the steps below if your system includes a front bezel. 1. Unlock the bezel. 2. Disconnect any cables attached to the control panel. 3. Pull the bezel from the server system. TP02129 Figure 18. Removing the Front Bezel Intel® Server System SR2500AL User's Guide 29
  • Intel SR2500ALBRPR | User Guide - Page 52
    removing the chassis cover, power down the server and unplug all peripheral devices and the AC power cable(s). Note: A nonskid surface or a stop behind the server system may be needed to prevent the server system from sliding on your work surface. 30 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 53
    system sidewalls. 2. Slide the cover forward until it clicks into place (see letter "A"). 3. (Optional) Insert the safety screw at the center of the top cover (see letter "B") if required. 4. Reconnect all peripheral devices and the AC power cord(s). Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 54
    ". 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the System Cover". 4. Lift the processor air duct from its location over the two processor sockets. 32 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 55
    TP02131 Figure 22. Removing the Processor Air Duct Intel® Server System SR2500AL User's Guide 33
  • Intel SR2500ALBRPR | User Guide - Page 56
    caution not to pinch or disengage cables that may be near or under the air duct. 7. Install the server system cover. For instructions, see "Installing the Server System Cover". 8. Plug all peripheral devices and the AC power cable(s) into the server. 34 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 57
    Turn off the server. 3. Disconnect the AC power cord(s) from the server. 4. Remove the server's cover. See the documentation that came with your server chassis for instructions on removing the server's cover. 5. Locate the DIMM sockets (see Figure 25). Intel® Server System SR2500AL User's Guide 35
  • Intel SR2500ALBRPR | User Guide - Page 58
    clips snap into place (see letter "C" in the figure above). Make sure the clips are firmly in place (see letter "D" in the figure above). 36 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 59
    in damage to the system. Installing the Processor To install a processor, follow these instructions: 1. Observe the safety and ESD precautions in "Safety Information". 2. Turn off all peripheral devices connected to the server. Turn off the server. Intel® Server System SR2500AL User's Guide 37
  • Intel SR2500ALBRPR | User Guide - Page 60
    the server. 4. Remove the server's cover. See the documentation that came with your server chassis for instructions on removing the server's cover. 5. Locate the processor socket cover for use when removing a processor that will not be replaced. 38 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 61
    the TIM. 1. Set the heat sink over the processor, lining up the four captive screws with the four posts surrounding the processor. 2. Loosely screw in the captive screws on the 4 TP02077 Figure 29. Installing the Heat Sink (2U Passive Heat Sink Shown) Intel® Server System SR2500AL User's Guide 39
  • Intel SR2500ALBRPR | User Guide - Page 62
    and reconnect any parts you removed or disconnected to reach the processor sockets. 5. Replace the server's cover and reconnect the AC power cord(s). See the documentation that came with your server chassis for instructions on installing the server's cover. Removing a Processor 1. Observe the safety
  • Intel SR2500ALBRPR | User Guide - Page 63
    down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the server system cover. For instructions, see "Removing the System Cover". 4. the server system. 2. Snap the baffle into place as shown in the figure below. TP02136 Intel® Server System SR2500AL User's Guide 41
  • Intel SR2500ALBRPR | User Guide - Page 64
    all peripheral devices and the AC power cable(s). 3. Remove the server system cover. For instructions, see "Removing the System Cover". 4. Note how the cables are routed over and under the air baffle (if any). You will need to re-route these cables. 42 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 65
    . 2. While setting the baffle into place, route the cables beneath it appropriately. See Appendix , "Cable Routing" or the Quick Reference Label that came with your system for help in determining where the cables should be routed. Intel® Server System SR2500AL User's Guide 43
  • Intel SR2500ALBRPR | User Guide - Page 66
    of supported hardware. Installing a SAS or SATA Hot-swap Hard Disk Drive 1. Remove the front bezel if it is installed. For instructions, see "Removing the Front Bezel". 2. Open the latch at the front of the hard drive carrier. See letter "A" in the figure below. 44 Intel® Server System SR2500AL
  • Intel SR2500ALBRPR | User Guide - Page 67
    antistatic surface. 6. Set any jumpers and/or switches on the drive according to the drive manufacturer's instructions. 7. With the drive circuit-side down, position the connector end of the drive so that it attached to the plastic retention device. Intel® Server System SR2500AL User's Guide 45
  • Intel SR2500ALBRPR | User Guide - Page 68
    the server system cover. For instructions, see "Installing the Server System Cover". 12. (Optional) Install the front bezel. For instructions, see "Installing the Front Bezel". 13. Plug all peripheral devices and the AC power cable(s) into the server. 46 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 69
    connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. To maintain proper system cooling, a filler blank must be installed if you do not install a device at this location. Intel® Server System SR2500AL User's Guide 47
  • Intel SR2500ALBRPR | User Guide - Page 70
    front bezel if it is installed. For instructions, see "Removing the Front Bezel". 4. Remove the server system cover. For instructions, see "Removing the System Cover". 5. Insert the interposer board into to the documentation that came with the device. 48 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 71
    Server System 14. Install the server system cover. For instructions, see "Installing the Server System Cover". 15. (Optional) Install the front bezel. For instructions, slimline optical drive tray assembly from the server system as shown in Figure 40. Intel® Server System SR2500AL User's Guide 49
  • Intel SR2500ALBRPR | User Guide - Page 72
    B C AF000151 Figure 40. Removing the Slimline Optical Drive Assembly from the Server System 7. Press downward on the side of the tray (see letter "A") and disengage tray. C B A AF000152 Figure 41. Removing the Slimline Optical Drive from the Tray 50 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 73
    precautions at the beginning of this book. See "Safety Information". 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the front bezel if it is installed. For instructions, see "Removing the Front Bezel". Intel® Server System SR2500AL User's Guide 51
  • Intel SR2500ALBRPR | User Guide - Page 74
    Filler Panel from the Server System 6. Remove the hard drive blank that is installed in the sixth drive bay. See the figure below to locate the sixth drive filler panel. AF000035 Figure 44. Removing Sixth Drive Filler Panel from the Server System 52 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 75
    drive into the combined tape drive bay/sixth drive bay until the carrier clicks into place. AF000033 Figure 46. Installing Tape Drive Assembly into the Server System Intel® Server System SR2500AL User's Guide 53
  • Intel SR2500ALBRPR | User Guide - Page 76
    , see "Removing the Front Bezel". 4. Remove the server system cover. For instructions, see "Removing the System Cover". 5. Slide the sixth HDD bracket into the backplane as shown in the figure below. Figure 47. Installing Sixth HDD Bracket AF000012 54 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 77
    in your system. If you have an active mid-plane in your system, go to step 7 for cabling instructions. If you have a passive mid-plane in your system, go to step 8 for cabling instructions. 7. from the 6th HDD kit in a system with an active mid- plane. Intel® Server System SR2500AL User's Guide 55
  • Intel SR2500ALBRPR | User Guide - Page 78
    the server system cover. For instructions, see "Installing the Server System Cover". 11. (Optional) Install the front bezel. For instructions, see "Installing the Front Bezel". 12. Plug all peripheral devices and the AC power cable(s) into the server. 56 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 79
    To remove the PCI riser assembly, use the following instructions. 1. Observe the safety and ESD precautions at the beginning of this book. See "Safety Information". 2. Power down the server and unplug all peripheral devices and the AC power cable(s). Intel® Server System SR2500AL User's Guide 57
  • Intel SR2500ALBRPR | User Guide - Page 80
    3. Remove the server system cover. For instructions, see "Removing the System Cover". 4. Remove the processor air duct by lifting straight up. 5. Disconnect any cables attached to PCI riser assembly for another procedure, continue with that procedure. 58 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 81
    the Processor Air Duct". 6. Install the server system cover. For instructions, see "Installing the Server System Cover". 7. (Optional) Install the front bezel. For instructions, see "Installing the Front Bezel". 8. Plug all peripheral devices and the AC power cable(s) into the server. Intel® Server
  • Intel SR2500ALBRPR | User Guide - Page 82
    Remove the server system cover. For instructions, see "Removing the System Cover". 4. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct". ) and remove from the server system (see letter "C" in the figure below). 60 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 83
    the processor air duct. For instructions, see "Installing the Processor Air Duct". 15. Install the server system cover. For instructions, see "Installing the Server System Cover". 16. Plug all peripheral devices and the AC power cable(s) into the server. Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 84
    Remove the server system cover. For instructions, see "Removing the System Cover". 4. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct PCI Riser Card into the Server System 11. Release the blue locking lever. 62 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 85
    Re-install the processor air duct. For instructions, see "Installing the Processor Air Duct". 16. Install the server system cover. For instructions, see "Installing the Server System Cover". 17. until it seats in riser card connector (see letter "D"). Intel® Server System SR2500AL User's Guide 63
  • Intel SR2500ALBRPR | User Guide - Page 86
    system cover. For instructions, see "Removing the System Cover". 4. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct". 5. Remove the PCI riser assembly. For instructions, see "Removing the PCI Riser Assembly". 64 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 87
    the processor air duct. For instructions, see "Installing the Processor Air Duct". 12. Install the server system cover. For instructions, see "Installing the Server System Cover". 13. Plug all peripheral devices and the AC power cable(s) into the server. Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 88
    processor air duct. For instructions, see "Installing the Processor Air Duct". 9. Install the server system cover. For instructions, see "Installing the Server System Cover". 10. Plug all peripheral devices and the AC power cable(s) into the server. 66 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 89
    the processor air duct. For instructions, see "Installing the Processor Air Duct". 10. Install the server system cover. For instructions, see "Installing the Server System Cover". 11. Plug all peripheral devices and the AC power cable(s) into the server. Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 90
    devices and the AC power cable(s). 3. Remove the server system cover. For instructions, see "Removing the System Cover". 4. Remove the PCI riser assembly. For instructions, see "Removing the PCI Riser Assembly". 5. Squeeze the sides of the Intel® RMM NIC module cover to disengage it from the
  • Intel SR2500ALBRPR | User Guide - Page 91
    the processor air duct. For instructions, see "Installing the Processor Air Duct". 4. Install the server system cover. For instructions, see "Installing the Server System Cover". 5. Plug all peripheral devices and the AC power cable(s) into the server. Intel® Server System SR2500AL User's Guide 69
  • Intel SR2500ALBRPR | User Guide - Page 92
    processor air duct. For instructions, see "Installing the Processor Air Duct". 11. Install the server system cover. For instructions, see "Installing the Server System Cover". 12. Plug all peripheral devices and the AC power cable(s) into the server. 70 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 93
    server and unplug all peripheral devices and the AC power cable(s). 3. Remove the server system cover. For instructions, see "Removing the System AF000164 Figure 61. Removing the Bridge Board from the Server System 6. Remove the fan module. For instructions, see "Replacing a Fan Module". 7. Hold the
  • Intel SR2500ALBRPR | User Guide - Page 94
    . For instructions, see "Removing the System Cover". 4. Position the mid-plane board over the retention pins as shown in the figure below (see letter "A"). 5. Slide the mid-plane board forward (see letter "B") and insert the mid-plane into the backplane connector as shown. 72 Intel® Server System
  • Intel SR2500ALBRPR | User Guide - Page 95
    below), and inserting it into the connector on the server board (see letter "C" in the figure below. Close the retention mechanism to hold the bridge board in place. A C B C A AF000163 Figure 64. Installing the Bridge Board into the Server System Intel® Server System SR2500AL User's Guide 73
  • Intel SR2500ALBRPR | User Guide - Page 96
    . For instructions, see "Removing a SAS or SATA Hot-swap Hard Disk Drive". 6. Disconnect all cables from the backplane. 7. Firmly grasp the top of the backplane and remove the backplane from the server system by pulling straight up as shown in the figure below. 74 Intel® Server System SR2500AL
  • Intel SR2500ALBRPR | User Guide - Page 97
    AF000016 Figure 65. Removing the Backplane from the Server System Intel® Server System SR2500AL User's Guide 75
  • Intel SR2500ALBRPR | User Guide - Page 98
    66. Installing the Backplane into the Server System 8. Install hot-swap drive carriers. For instructions, see "Installing a SAS or SATA Hot-swap Hard Disk Drive". 9. Install the mid-plane board. For instructions, see "Installing the Mid-plane Board". 76 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 99
    mechanism (see letter "B" in the figure below) and inserting the DIMM into the socket (see letter "C" in the figure below). A B B C AF000742 Figure 67. Installing the RAID Activation Key and the RAID Mini DIMM Intel® Server System SR2500AL User's Guide 77
  • Intel SR2500ALBRPR | User Guide - Page 100
    the large air baffle. For instructions, see "Installing the Large Air Baffle". 8. Install the server system cover. For instructions, see "Installing the Server System Cover". 9. Plug all peripheral devices and the AC power cable(s) into the server. 78 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 101
    A B AF000149 Figure 69. Installing the RAID Battery Backup Unit 7. Install the large air baffle. For instructions, see "Installing the Large Air Baffle". 8. Install the server system cover. For instructions, see "Installing the Server System Cover". Intel® Server System SR2500AL User's Guide 79
  • Intel SR2500ALBRPR | User Guide - Page 102
    the large air baffle. For instructions, see "Installing the Large Air Baffle". 8. Install the server system cover. For instructions, see "Installing the Server System Cover". 9. Plug all peripheral devices and the AC power cable(s) into the server. 80 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 103
    instructions, see "Replacing a Fan Module". 10. Place the server board into the server system as shown in the figure below (see letter "A"), and attach the server board with six screws (see letter "B"). B A AF000025 Figure 71. Installing the Server Board Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 104
    fan module assembly. For instructions, see "Replacing a Fan Module". 10. Disconnect all cables from the server board. 11. Remove memory. For instructions, see "Removing DIMMs". 12. Remove the processor(s). For instructions, see "Removing a Processor". 82 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 105
    the processor air duct. For instructions, see "Installing the Processor Air Duct". 22. Install the server system cover. For instructions, see "Installing the Server System Cover". 23. Plug all peripheral devices and the AC power cable(s) into the server. Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 106
    enligt fabrikantens instruktion. Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. 84 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 107
    its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run Setup to restore the configuration settings to the RTC. Intel® Server System SR2500AL User's Guide 85
  • Intel SR2500ALBRPR | User Guide - Page 108
    at the beginning of this book. See "Safety Information". 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the server system cover. For instructions, see "Removing the System Cover". 4. If a filler panel is installed, press the release lever (see letter
  • Intel SR2500ALBRPR | User Guide - Page 109
    AF000023 Figure 77. Installing Power Supply Filler Panel into the Server System 8. Install the server system cover. For instructions, see "Installing the Server System Cover". 9. Plug all peripheral devices and the AC power cable(s) into the server. Intel® Server System SR2500AL User's Guide 87
  • Intel SR2500ALBRPR | User Guide - Page 110
    Power Distribution Module AF000146 10. Set the replacement power supply distribution module into the server system and screw the module into place. 11. Install the hot-swap power supply/supplies. For instructions, see "Replacing the Power Supply". 88 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 111
    the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the front bezel if it is installed. For instructions, see "Removing the Front Bezel". 4. Remove the server system cover. For instructions, see "Removing the System Cover". Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 112
    Control Panel Module from the Server System 7. Slide the replacement control panel into the server system (see letter "A") until it clicks into place (see letter "B"). B A AF000006 Figure 80. Installing Control Panel Module into the Server System 90 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 113
    the bridge board. For instructions, see Figure 61 "Removing the Bridge Board from the Server System" on page -71. 8. Remove the large air baffle. For instructions, see "Removing the Large Air Baffle". 9. Disconnect the fan cables from the mid-plane. Intel® Server System SR2500AL User's Guide 91
  • Intel SR2500ALBRPR | User Guide - Page 114
    "B"). B A B A Figure 82. Installing the Redundant Fan Module 12. Connect the fan cables to the mid-plane. 13. Install the large air baffle. For instructions, see "Installing the Large Air Baffle". Re-route cables through the air baffle as necessary. 92 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 115
    the bridge board. For instructions, see Figure 61 "Removing the Bridge Board from the Server System" on page -71. 8. Remove the large air baffle. For instructions, see "Removing the Large Air Baffle". 9. Disconnect the fan cables from the mid-plane. Intel® Server System SR2500AL User's Guide 93
  • Intel SR2500ALBRPR | User Guide - Page 116
    to the left (see letter "B" in), and lifting the assembly off of the standoff and out of the system (see letter "C"). A B C B C Figure 83. Removing the Fixed Fan Module 11. Install the letter "B"). B A B A Figure 84. Installing the Fixed Fan Module 94 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 117
    Observe the safety and ESD precautions at the beginning of this book. See "Safety Information". 2. Remove the server system cover. For instructions, see "Removing the System Cover". 3. There are no screws to loosen. Lift the failed fan from the module. Intel® Server System SR2500AL User's Guide 95
  • Intel SR2500ALBRPR | User Guide - Page 118
    the connector on the fan into the matching connector on the fan module. 5 6 34 2 1 AF000009 Figure 86. Installing a Fan into the Redundant Fan Module 96 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 119
    the server system cover. For instructions, see "Installing the Server System Cover". Replacing a Fixed Fan Caution: The system fans are NOT hot swappable. Before removing or replacing a fan, you must first take the server out of service, turn off all peripheral devices connected to the system, turn
  • Intel SR2500ALBRPR | User Guide - Page 120
    . For instructions, see "Removing the System Cover". 4. Align the rack handle with the two holes on the side of the server system as shown in the figure below. 5. Attach the rack handle to the server system with two screws as shown in the figure below. 98 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 121
    "Removing the Front Bezel". 4. Remove the server system cover. For instructions, see "Removing the System Cover". 5. Remove the two screws holding the rack handle in place, and remove the rack handle from the server system as shown in the figure below. Intel® Server System SR2500AL User's Guide 99
  • Intel SR2500ALBRPR | User Guide - Page 122
    AF000020 Figure 90. Removing the Rack Handle 6. Install the server system cover. For instructions, see "Installing the Server System Cover". 7. Plug all peripheral devices and the AC power cable(s) into the server. 100 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 123
    Utility options, which is used to change server configuration defaults. You can run BIOS Setup with or without an operating system being present. See "Server System References" for a link to the Intel® 5000 Series Chipsets Server Board Family Datasheet where you will find details about specific
  • Intel SR2500ALBRPR | User Guide - Page 124
    the keyboard commands you can use in the BIOS Setup menus. Table 4. Setup Menu Key Setup Defaults - Pressing causes the following to appear: Setup Confirmation Load default configuration now? [Yes] [No] If "Yes" is selected and the key 102 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 125
    and press when you see the message: Press Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip step 2. You will need these settings to configure your server at the end of the procedure. Intel® Server System SR2500AL User's Guide 103
  • Intel SR2500ALBRPR | User Guide - Page 126
    folder on your hard drive. See "Server System References" for a link to the update software. Note: Review the instructions and release notes that are provided in the readme file distributed with the BIOS image file before attempting a BIOS upgrade. The release notes contain critical information
  • Intel SR2500ALBRPR | User Guide - Page 127
    the configuration RAM. 1. Power down the system and disconnect the AC power. 2. Open the server. 3. Move the jumper from the normal operation position, CMOS Clear by BMC, at pins 1 and 2 to the CMOS Clear Force Erase position, covering pins 2 and 3. Intel® Server System SR2500AL User's Guide 105
  • Intel SR2500ALBRPR | User Guide - Page 128
    . 5. Return the CMOS Clear jumper to the CMOS Clear by BMC location, covering pins 1 and 2. 6. Close the server chassis. 7. Reconnect the AC power and power up the system. 8. The CMOS is now cleared and can be reset by going into the BIOS setup. 106 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 129
    or remove components from your server system, make sure your cables are routed correctly before reinstalling the server system cover. Use caution to to Server Board (Aux.) B Power to Server Board (Main) C Power to Server Board (CPU) D Power to Midplane Board E Power to Backplane Board F RAID Battery
  • Intel SR2500ALBRPR | User Guide - Page 130
    -redundant Fan Power Cables to the Passive Mid-plane Board 6 5 4 3 2 1 TP02140 Figure 95. Connecting the Redundant Fan Power Cables to the Active Midplane Board 108 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 131
    combined total wattage of 750 Watts. For information about calculating the power usage for your configuration, see "Calculating Power Usage." Table 5. Power Supply Output Capability Voltage +3.3 V +5.0 the power supplies to overheat and malfunction. Intel® Server System SR2500AL User's Guide 109
  • Intel SR2500ALBRPR | User Guide - Page 132
    Environmental Specifications Table 6. System Environmental Specifications Temperature Non-operating Operating Humidity Non-operating Shock Operating Packaged Acoustic noise Electrostatic level. Tested to 15 kilovolts (kV); no component damage. 110 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 133
    in your system, such as video drivers, network drivers, and SATA drivers. Intel provides a package called the "Platform Confidence Test" that may help with your diagnostics. See "Server System References" for a link to this software. If you are unable to resolve your server problems on your
  • Intel SR2500ALBRPR | User Guide - Page 134
    as the supported hardware and operating system list. See "Server System References" for links to the tested component lists. Hardware Diagnostic Testing This section provides a more detailed approach to identifying a hardware problem and locating its source. 112 Intel® Server System SR2500AL
  • Intel SR2500ALBRPR | User Guide - Page 135
    Appear on Screen". Specific Problems and Corrective Actions This section provides possible solutions for these specific problems: • Power light does not light. • No characters appear on screen. • Characters on the screen appear distorted or incorrect. Intel® Server System SR2500AL User's Guide 113
  • Intel SR2500ALBRPR | User Guide - Page 136
    you cannot correct the problem, contact your service representative or authorized processor(s) comply with the system requirements. • Make sure the processor(s) have been populated according to the system requirements. • Remove the processor system? 114 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 137
    Does this video monitor work correctly if plugged into a different system? System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, it is an indication of possible system component failure. Check the following: Intel® Server System SR2500AL User's Guide 115
  • Intel SR2500ALBRPR | User Guide - Page 138
    correctly? • Is the drive properly configured? • Is the drive activity system back panel. • Try a different network cable. • Make sure you are using the correct and the current drivers. See "Server System References" for a link to the current drivers. 116 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 139
    the add-in adapter. The add-in adapter stopped working without apparent cause • Reseat the adater. • Put the adapter in a different slot. • The network driver files may be corrupt or deleted. Delete and then reinstall the drivers. • Run diagnostics. Intel® Server System SR2500AL User's Guide 117
  • Intel SR2500ALBRPR | User Guide - Page 140
    device drivers installed. If the problems persist, contact the software vendor's customer service representative. Problems with Application Software that Ran Correctly Earlier Problems that occur after the system hardware and software have been running correctly sometimes indicate equipment failure
  • Intel SR2500ALBRPR | User Guide - Page 141
    • If using a RAID configuration with SCSI or SATA drives, make sure the RAID card is installed correctly. Bootable CD-ROM Disk Is Not Detected Check the following: • Make sure the BIOS is configured to allow the CD-ROM to be the first bootable device. Intel® Server System SR2500AL User's Guide 119
  • Intel SR2500ALBRPR | User Guide - Page 142
    are supported by BIOS beep codes. Table 9. POST Error Beep Codes Number of Beeps 1, 2, or 3 4 - 7 or 9 - 11 8 Reason for Beeps and Action to Take Memory error. Reseat the memory or replace the DIMMs with known good modules. Fatal error indicating a possible serious system problem. Remove
  • Intel SR2500ALBRPR | User Guide - Page 143
    or CPU 1 socket is empty. Reseat or replace the failed processor. In a two-processor system, make sure the processors are identical. Front-side bus select configuration error. DC power unexpectedly lost. Chipset control failure. Power control failure. Intel® Server System SR2500AL User's Guide 121
  • Intel SR2500ALBRPR | User Guide - Page 144
    122 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 145
    at http:// support.intel.com/support/motherboards/server/chassis/SR2500/. For the fastest service, please submit your form via the Internet. Date Submitted Company Name Contact Name Email Address Intel Server Product Priority (Critical, Hot, High, Low Brief Problem Description. Provide
  • Intel SR2500ALBRPR | User Guide - Page 146
    / part number DIMM D2 MB and Vendor / part number Operating System Information Operating System Version Service Pack Add-in Card, Peripheral, Video, NIC Check each box below as applicable, and provide the requested information. Peripheral Card or Peripheral Description Driver Revision
  • Intel SR2500ALBRPR | User Guide - Page 147
    Driver Revision IRQ I/O Base FW Address Revision Hot-swap or Fixed IRQ FW Revision Management Information On-Board Platform Instrumentation only Intel® Remote Management Module Control Panel Information Standard Control Panel Intel® Local Control Panel Intel® Server System SR2500AL
  • Intel SR2500ALBRPR | User Guide - Page 148
    Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done 126 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 149
    of which is assigned a specific hex POST code number. As each configuration routine is started, BIOS will display the given POST code to the POST Code Diagnostic LEDs found on the back edge of the server board. To assist in troubleshooting a system hang during the POST process, the Diagnostic LEDs
  • Intel SR2500ALBRPR | User Guide - Page 150
    presence of memory OFF Programming timing parameters in the memory controller G Configuring memory parameters in the memory controller OFF Optimizing memory controller settings G Initializing memory, such as ECC init OFF Testing memory 128 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 151
    (VGA) Resetting the console controller Disabling the console controller Enabling the console controller Resetting the keyboard Disabling the keyboard Detecting the presence of the keyboard Intel® Server System SR2500AL User's Guide 129
  • Intel SR2500ALBRPR | User Guide - Page 152
    OFF R Clearing keyboard input buffer R G OFF A Instructing keyboard controller to run Self Test (PS2 only) , etc.) A G R R Enabling / configuring a removable media device Boot Device Selection 0xD0 0xD1 A Trying boot device selection 130 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 153
    R A Exiting Sleep state A R R R Operating system has requested EFI to close boot services (ExitBootServices ( ) has been called) A R R A Operating system has switched to virtual address mode (SetVirtualAddressMap ( ) has been called) Intel® Server System SR2500AL User's Guide 131
  • Intel SR2500ALBRPR | User Guide - Page 154
    . Diagnostic LED POST Code Decoder 0xFAh A R A R Operating system has requested the system to reset (ResetSystem () has been called) Pre-EFI Initialization Module to the crisis recovery capsule G G A A Unable to complete crisis recovery. 132 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 155
    Wide Web http://support.intel.com/support/motherboards/server/chassis/SR2500. Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time
  • Intel SR2500ALBRPR | User Guide - Page 156
    8 621 33104691 (not toll-free) Hong Kong 852 2 844 4456 India........... 0006517 2 68303634 (manual toll-free. You need an IDD-equipped telephone) Indonesia ... 803 65 7249 Korea ......... 822 767 2595 800 225 288. Once connected, dial 800 843 4481 134 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 157
    0114 Peru 001 916 377 0114 Uruguay..... 001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Server System SR2500AL User's Guide 135
  • Intel SR2500ALBRPR | User Guide - Page 158
    136 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 159
    , you must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
  • Intel SR2500ALBRPR | User Guide - Page 160
    CSA 60950 - UL 60950 (Safety) None Required Canada / USA China Industry Canada ICES-003 (Emissions) FCC CFR 47, Part 15 (Emissions) CNCA - CB4943 (Safety) GB 9254 (Emissions) GB17625 (Harmonics) CANADA ICES-003 CLASS A CANADA NMB-003 CLASSE A 138 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 161
    International CB Certification IEC60950 CISPR 22 / CISPR 24 None Required Japan VCCI Certification Korea RRL Certification MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) Intel® Server System SR2500AL User's Guide 139
  • Intel SR2500ALBRPR | User Guide - Page 162
    Russia Ukraine Compliance Reference GOST-R Certification GOST R 2921691 (Emissions) GOST R 5062895 (Immunity) Ukraine Certification Compliance Reference Marking Example None Required Taiwan BSMI CNS13438 R33025 140 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 163
    performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits and used in accordance with the instructions, may cause harmful interference to Intel® Server System SR2500AL User's Guide 141
  • Intel SR2500ALBRPR | User Guide - Page 164
    receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. 142 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 165
    area of the product. Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. The following is Intel's product ecology compliance criteria. Intel® Server System SR2500AL User's Guide 143
  • Intel SR2500ALBRPR | User Guide - Page 166
    / part includes Friendly Use Period (EFUP). Number represents years. China Recycling ( intel.com/ehs/environmental.htm None Required Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ EC - Mark applied to system level products only. 144 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 167
    in Intel's Environmental Product Content Specification of Suppliers and Outsourced Manufacturers - http:// supplier.intel.com/ehs/environmental.htm. ISO11469 - Plastic parts weighing Japan Recycling Applied to Retail Packaging Only for Boxed Boards Intel® Server System SR2500AL User's Guide 145
  • Intel SR2500ALBRPR | User Guide - Page 168
    cords before servicing. Simplified Chinese 'ˆÓ F 2 j Traditional Chinese 'ˆÓ F 2 German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung 146 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 169
    for the region in which it is sold. • Peripheral Storage Devices: must be a UL recognized or UL listed accessory and TUV or VDE licensed. Total server configuration is not to exceed the maximum loading conditions of the power supply. Intel® Server System SR2500AL User's Guide 147
  • Intel SR2500ALBRPR | User Guide - Page 170
    End-of-Life / Product Recycling Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back. 148 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 171
    publicly available specifications for a period of three (3) years after the date the Product was purchased from an Intel authorized distributor. Software of any kind delivered with or as part of products is expressly provided "as is" unless specifically provided for otherwise in any software license
  • Intel SR2500ALBRPR | User Guide - Page 172
    causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration Service To obtain warranty service for this Product, you may contact Intel or your authorized distributor. 150 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 173
    http:// www.intel.com/), call your local distributor or an Intel Customer Support representative. See "Getting Help" for telephone numbers. Returning a Defective Product Before returning any product, call your authorized dealer/distribution authority. Intel® Server System SR2500AL User's Guide 151
  • Intel SR2500ALBRPR | User Guide - Page 174
    152 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 175
    /Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only to system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 176
    with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. 154 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 177
    Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Server System SR2500AL User's Guide 155
  • Intel SR2500ALBRPR | User Guide - Page 178
    anzubringen: 1. Vergewissern Sie sich, daß Sie keine Werkzeuge oder Teile im Innern des Systems zurückgelassen haben. 2. Überprüfen Sie alle Kabel, Zusatzkarten und andere Komponenten auf Batterien den Anweisungen des Herstellers entsprechend. 156 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 179
    Français Das System wurde für den Betrieb in einer normalen Büroumgebung entwickelt. Der Standort sollte: • "sauber und staubfrei sein (Hausstaub Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. Intel® Server System SR2500AL User's Guide 157
  • Intel SR2500ALBRPR | User Guide - Page 180
    a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. 158 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 181
    type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. alimentación de corriente alterna que tenga el producto Intel® Server System SR2500AL User's Guide 159
  • Intel SR2500ALBRPR | User Guide - Page 182
    las tapas del sistema. Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de los cables externos y los cables de alimentación CA al sistema. 160 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 183
    ñado para funcionar en un entorno de trabajo normal. Escoja un lugar: • "Limpio y libre de partículas en suspensión (salvo el polvo normal). • "Bien ventilado y alejado de fuentes de calor, éstos hacen de medio principal de desconexión del sistema. Intel® Server System SR2500AL User's Guide 161
  • Intel SR2500ALBRPR | User Guide - Page 184
    lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 185
    tipo. Scegliere una postazione che sia: • "Pulita e libera da particelle in sospensione (a parte la normale polvere presente nell'ambiente). • "Ben ventilata e lontana da fonti di calore rappresentano il mezzo principale di scollegamento del sistema. Intel® Server System SR2500AL User's Guide 163
  • Intel SR2500ALBRPR | User Guide - Page 186
    164 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 187
    server should be integrated and serviced only by technically qualified persons. You must adhere to the guidelines in this guide and the assembly instructions in your server manuals instructions are not followed. Indicates hot components or surfaces. Intel® Server System SR2500AL User's Guide 165
  • Intel SR2500ALBRPR | User Guide - Page 188
    In regions that are susceptible to electrical storms, we recommend you plug your system into a surge suppresser and disconnect telecommunication lines to your modem during an the weight for easier handling, remove any easily detachable components. 166 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 189
    Intel® servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing. The power supply in this product contains no user-serviceable parts is /are provided with a suitable earth ground. Intel® Server System SR2500AL User's Guide 167
  • Intel SR2500ALBRPR | User Guide - Page 190
    the system without the fan guard in place. Rack Mount Warnings The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it. The equipment rack must be installed according to the rack manufacturer's instructions
  • Intel SR2500ALBRPR | User Guide - Page 191
    instructions. Laser Peripherals or Devices Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Intel® Server System
  • Intel SR2500ALBRPR | User Guide - Page 192
    hin, der bei Nichtbeachtung der Sicherheitshinweise zu schweren oder tödlichen Verletzungen führen kann. Weist auf Verbrennungsgefahr an heißen Bauteilen bzw. Oberflächen hin. 170 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 193
    Geräte erzeugt werden. • In gewittergefährdeten Gebieten sollten Sie das System an einen Überspannungsschutz anschließen und bei einem Gewitter die Telekommunikationskabel zum lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Server System SR2500AL User's Guide 171
  • Intel SR2500ALBRPR | User Guide - Page 194
    vom Stromnetz. Die Steckdose muß in der Nähe der Anlage angebracht und gut erreichbar sein. • Netzkabel müssen an eine ordnungsgemäß geerdete Steckdose angeschlossen sein. 172 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 195
    vor, und bauen Sie das schwerste Gerät an der untersten Position im Rack ein. Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus. Intel® Server System SR2500AL User's Guide 173
  • Intel SR2500ALBRPR | User Guide - Page 196
    aus dem Server mit der Bauelementseite Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen Sie die Abdeckung wieder an: • Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben. 174 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 197
    uniquement par des techniciens qualifiés. Vous devez suivre les informations de ce guide et les instructions d'assemblage des manuels de serveur pour vérifier et maintenir la conformité et peuvent figurer sur le produit ou sur son emballage. Intel® Server System SR2500AL User's Guide 175
  • Intel SR2500ALBRPR | User Guide - Page 198
    soleil et les radiateurs. • À l'écart des sources de vibration ou des chocs physiques. • Isolé des champs électromagnétiques importants produits par des appareils électriques. 176 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 199
    ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'alimentation. L'intérieur de celui-ci est soumis à des Intel® Server System SR2500AL User's Guide 177
  • Intel SR2500ALBRPR | User Guide - Page 200
    Les cordons d'alimentation doivent répondre aux critères suivants : - Le cordon d'alimentation doit supporter une intensité supérieure à celle indiquée sur le produit. - Le cordon d'alimentation doit télécommunication qui sont connectés au système. 178 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 201
    le montage en rack Le rack doit être fixé à un support inamovible pour éviter qu'il ne bascule lors de l'extension d' l'équipement. Le rack doit être installé conformément aux instructions du fabricant. Installez les équipements dans le rack en partant Intel® Server System SR2500AL User's Guide 179
  • Intel SR2500ALBRPR | User Guide - Page 202
    système. • Vérifiez que les câbles, les cartes d'extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. 180 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 203
    irse a las directrices de esta guía y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con las certificaciones y homologaciones existentes de los graves si no se tiene en cuenta la ADVERTENCIA. Intel® Server System SR2500AL User's Guide 181
  • Intel SR2500ALBRPR | User Guide - Page 204
    conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. 182 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 205
    conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precaució , adquiera alguno cuyo uso esté aprobado en su país. Intel® Server System SR2500AL User's Guide 183
  • Intel SR2500ALBRPR | User Guide - Page 206
    para repararla. • Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que no es de conexión en funcionamiento. 184 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 207
    del bastidor. Instale el equipo en el bastidor comenzando desde la parte de abajo, con el equipo más pesado en la parte inferior del bastidor. Extraiga las piezas del equipo del bastidor de contra descargas electrostáticas. En caso de que no haya una Intel® Server System SR2500AL User's Guide 185
  • Intel SR2500ALBRPR | User Guide - Page 208
    dentro del sistema. • Compruebe que los cables, tarjetas adicionales y otros componentes están instalados correctamente. • Sujete las cubiertas a la carcasa siguiendo las instrucciones del producto. 186 Intel® Server System SR2500AL User's Guide
  • Intel SR2500ALBRPR | User Guide - Page 209
    caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare Intel® Server System SR2500AL User's Guide 187
  • Intel SR2500ALBRPR | User Guide - Page 210
    188 Intel® Server System SR2500AL User's Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

Intel
®
Server System SR2500AL
User’s Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/
Products
Intel Order Number D31969-004