Intel SRCU42X Hardware User Guide

Intel SRCU42X Manual

Intel SRCU42X manual content summary:

  • Intel SRCU42X | Hardware User Guide - Page 1
    Hardware User's Guide Intel® RAID Controller SRCU42X April 2004 C49616-003
  • Intel SRCU42X | Hardware User Guide - Page 2
    not intended for use in medical, life saving, life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries
  • Intel SRCU42X | Hardware User Guide - Page 3
    caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http:\\support.intel.com\support\motherboards\server\safecert.htm. SAFETY STEPS: Whenever you remove the chassis
  • Intel SRCU42X | Hardware User Guide - Page 4
    toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http:\\support.intel.com\support\motherboards\server du capot. Nous vous recommandons l'usage de gants de protection. Intel RAID Controller SRCU42X 4
  • Intel SRCU42X | Hardware User Guide - Page 5
    / New Zealand) • BSMI CNS13438 (Taiwan) • RRL, MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) (Korea) Product Regulatory Compliance Markings The RAID Controller Card is marked with the following compliance markings. Some marking information may be provided on the packaging and/or in the product
  • Intel SRCU42X | Hardware User Guide - Page 6
    Regulatory Compliance cULus Listing Marks ETL (NRTL) Mark CE Mark FCC Marking (Class A) FCC Marking (Class B) EMC Marking (Class A) EMC Marking (Class B) VCCI Marking (Class A) VCCI Marking (Class B) Country USA/Canada Marking USA/Canada Europe USA USA Canada Canada Japan This device complies
  • Intel SRCU42X | Hardware User Guide - Page 7
    in accordance with the instructions, may cause harmful Intel. The correction of interferences casued by such unauhtorized modification, substitution, or attachement will be the responsibility of the user. This RAID Controller local Intel representative 3. Name of Certification Recipient: LSI Logic
  • Intel SRCU42X | Hardware User Guide - Page 8
    instructions and specifications . For information about how to configure the SRCU42X controller, and for an overview of the software drivers, see the Intel RAID Software User's Guide. Audience This document assumes that you have some familiarity with RAID controllers and related support
  • Intel SRCU42X | Hardware User Guide - Page 9
    When Working Inside Your Computer Notice: Do not attempt to service the computer system yourself, except as explained in this guide and elsewhere in Intel documentation. Always follow installation and service instructions closely. 1. Turn off your computer and any peripherals. 2. Disconnect your
  • Intel SRCU42X | Hardware User Guide - Page 10
    Protecting Against Electrostatic Discharge Static electricity can harm delicate components inside your computer. To prevent static damage, discharge static electricity from your body before you touch any of your computer's electronic components, such as the microprocessor. You can do so by touching
  • Intel SRCU42X | Hardware User Guide - Page 11
    20 2.4 After You Have Installed the Storage Adapter 24 Chapter 3 Intel RAID Controller SRCU42X Technical Reference 3.1 Overview 25 3.2 Intel RAID Controller SRCU42X Characteristics 27 3.3 Technical Specifications 27 3.3.1 Storage Adapter Specifications 27 3.3.2 Array Performance Features 28
  • Intel SRCU42X | Hardware User Guide - Page 12
    Figures 2.1 Install the Battery Backup Unit 20 2.2 Inserting the SRCU42X Adapter Card in a PCI Slot 21 2.3 Terminating an Internal SCSI Disk Array 23 3.1 Intel RAID Controller SRCU42X Layout 25 12
  • Intel SRCU42X | Hardware User Guide - Page 13
    Tables 1-1 Intel Raid SRCU42X Adapter Features 17 2-1 Target ID's 21 3-1 Intel RAID Controller SRCU42X Headers and Connectors . . 26 3-2 Storage Adapter Characteristics 27 3-3 Storage Adapter Specifications 27 3-4 Array Performance Features 28 3-5 Fault Tolerance Features 29 3-6 Maximum Power
  • Intel SRCU42X | Hardware User Guide - Page 14
    14 Contents
  • Intel SRCU42X | Hardware User Guide - Page 15
    for the internal storage of workgroup, departmental, and enterprise systems.The SRCU42X controller offers a cost-effective way to implement RAID in a server. The SRCU42X controller (dual-channel) has one LSI* 53C1030 controller chip that controls two SCSI channels. The SRCU42X controller has two
  • Intel SRCU42X | Hardware User Guide - Page 16
    The Intel RAID Controller SRCU42X supports the following operating systems: • Microsoft* Windows* XP • Microsoft* Windows* 2000 • Microsoft* Windows Server* 2003 • Microsoft* WIndows* 2003, 64-bit • Novell* NetWare* 6.x • Red Hat* Linux* 8.0 • Red Hat* Linux* 9.0 • Red Hat* Enterprise Server* 2.1 •
  • Intel SRCU42X | Hardware User Guide - Page 17
    configuration and configuration-on-disk. 1.3.1 Storage Adapter Configurations Table 1-1 describes the features for the Intel RAID Controller SRCU42X. Table 1-1 Intel Raid SRCU42X Adapter Features Feature Description RAID Levels 0, 1, 5, 10, 50 SCSI Device Types Synchronous or Asynchronous
  • Intel SRCU42X | Hardware User Guide - Page 18
    you make one change at a time. 1.3.3 Drive Roaming The Intel RAID Controller SRCU42Xs support drive roaming across channels on the same SRCU42X controller. Drive roaming lets an Intel Raid SRCU42X controller detect the actual RAID configuration, maintaining the integrity of the data on each disk
  • Intel SRCU42X | Hardware User Guide - Page 19
    install the RAID controller: • An Intel RAID SRCU42X controller • A host computer with an available 32- or 64-bit, 3.3V PCI or PCI-X expansion slot • The Resource CD • The necessary internal and/or external SCSI cables. Ensure that the SCSI cables conform to all SCSI specifications. • Ultra, Ultra2
  • Intel SRCU42X | Hardware User Guide - Page 20
    Controller SRCU42X is shipped with: ◊ The Resource CD, which contains Intel RAID drivers for supported operating systems, an electronic version of this guide, and other related documentation. ◊ A license agreement 2) (Optional, required to enable Write Back Cache) Attach the Battery Backup Unit (BBU
  • Intel SRCU42X | Hardware User Guide - Page 21
    non-disk devices (CD-ROM or tapes), regardless of the channel where they are connected. The Intel RAID Controller SRCU42X automatically occupies TID 7, which is the highest priority. The arbitration priority for a SCSI device depends on its TID. Table 2-1 Target ID's Priority TID Highest Lowest
  • Intel SRCU42X | Hardware User Guide - Page 22
    SCSI Devices to the Storage Adapter Use SCSI cables to connect SCSI devices to the SRCU42X controller. To connect the SCSI devices: a. Disable termination on any SCSI device that does not sit at the end of the SCSI bus. b. Configure all SCSI devices to supply TERMPWR. c. Connect cables to the SCSI
  • Intel SRCU42X | Hardware User Guide - Page 23
    seconds to initialize. During this time, the SRCU42X controller scans the SCSI channel(s). The BIOS Configuration utility prompt times out after several seconds. The second portion of the BIOS message displays the Intel RAID Controller SRCU42X number, firmware version, and cache SDRAM size. The
  • Intel SRCU42X | Hardware User Guide - Page 24
    You Have Installed the Storage Adapter After installation, you must configure the SRCU42X controller and install the operating system driver. The Intel RAID Software User's Guide instructs you about the configuration options and how to set them on your SRCU42X controller. After You Have Installed
  • Intel SRCU42X | Hardware User Guide - Page 25
    PCI-X Addendum to the PCI Local Bus Specification, Revision 1.0a. The Intel RAID Controller SRCU42X is used in PCI-X and PCI computer systems with PCI standard bracket types. Figure 3.1 Intel RAID Controller SRCU42X Layout External Very High- Density 68-pin SCSI Connector Channel 0 J1 J2 J7 J19
  • Intel SRCU42X | Hardware User Guide - Page 26
    Intel RAID Controller SRCU42X Headers and Connectors Connector Description Type Comments J1 Termination Enable Channel 0 3-pin header Jumper on pins 1-2: Software uses drive detection to control SCSI J2 Termination Enable Channel 1 3-pin header termination (default: do not change). Jumper
  • Intel SRCU42X | Hardware User Guide - Page 27
    boot code and firmware 2. For BIOS configuration storage SCSI Features SCSI Termination Plug n Play Active, Single Scatter/Gather Ended, or LVD Activity LED 3.3 Technical Specifications The design and implementation of the SRCU42X controller minimizes electromagnetic emissions, susceptibility
  • Intel SRCU42X | Hardware User Guide - Page 28
    ROM for Firmware Nonvolatile Random 32 Kbyte × 8 for storing RAID configuration Access Memory (RAM) 3.3.2 Array Performance Features Table 3-4 shows the SRCU42X controller array performance features: Table 3-4 Array Performance Features Specification Intel RAID Controller SRCU42X PCI Host
  • Intel SRCU42X | Hardware User Guide - Page 29
    features: Table 3-5 Fault Tolerance Features Specification Intel Raid Controller SRCU42X Support for SMART 1 Yes Optional Battery Backup for Cache Memory Yes. Up to 48 hours data retention. Drive Failure Detection Automatic Drive Rebuild Using Automatic Hot Spares Parity Generation and
  • Intel SRCU42X | Hardware User Guide - Page 30
    3.3.6 Safety Characteristics The Intel RAID Controller SRCU42X meets or exceeds the requirements of UL flammability rating 94 V0. Each bare board is also marked with the . Since these boards are installed in a PCI bus slot, all voltages are below the SELV 42.4 V limit. Technical Specifications 30
  • Intel SRCU42X | Hardware User Guide - Page 31
    SCSI, Ultra2 SCSI, Ultra160 SCSI, and Ultra320 SCSI require active termination. Basic Input/Output System. Software that provides basic read/write capability. Usually kept as firmware (ROM based). The system BIOS on the mainboard of a computer is used to boot and control the system. The SCSI BIOS
  • Intel SRCU42X | Hardware User Guide - Page 32
    printer, or CD-ROM) used with a computer and under the computer's control. SCSI peripherals are controlled through a SCSI SRCU42X controller (host adapter). A storage adapter (host adapter) and one or more SCSI peripherals connected by cables in a linear configuration. The adapter may exist anywhere
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

C49616-003
Intel
®
RAID Controller
SRCU42X
Hardware
User’s Guide
April 2004