    Monthly Specification Update Intel® Server System P4000IP/R2000IP Family, Intel® Workstation System P4000CR Family July, 2012 Enterprise Platforms and Services Marketing
  • Intel W2600CR | Specification update - Page 2
    Update. Information in this document is provided in connection with Intel products Intel® sales office or your distributor to obtain the latest specifications and before placing your product order. Intel, Itanium, Pentium, and Xeon are trademarks or registered trademarks of Intel Corporation
  • Intel W2600CR | Specification update - Page 3
    Integrated BMC Web Console - Power Control page - Perform Action button not functional 8 14. IPMI Get Chassis Status command returns incorrect Chassis Identify State ..........8 15. The BIOS and ME Firmware can't be updated successfully via Intel® One Boot Flash Update Utility(OFU) under SuSE
  • Intel W2600CR | Specification update - Page 4
    Enterprise Platforms and Services Marketing Monthly Specification Update IV
  • Intel W2600CR | Specification update - Page 5
    Enterprise Platforms and Services Marketing Monthly Specification Update Preface This document is an update to the specifications contained in the Intel® Server/Workstation Board S2600IP/W2600CR and Intel ® Server/Workstation System P4000IP/CR, R2000IP Technical Product Specification. It is
  • Intel W2600CR | Specification update - Page 6
    Integrated BMC Web Console - Power Control page - Perform Action button not functional. 14. Fix IPMI Get Chassis Status command returns incorrect Chassis Identify State 15. Fix The BIOS and ME Firmware can't be updated successfully via Intel® One Boot Flash Update Utility(OFU) under SuSE
  • Intel W2600CR | Specification update - Page 7
    Enterprise Platforms and Services Marketing Monthly Specification Update No. Plans 23 Fixed 24 Fix Description of Errata System will boot from on-board video although install add-in video card On-board VGA cannot be set to the highest resolution (1920x1080 and higher). No. 1. 2. 3. 4.
  • Intel W2600CR | Specification update - Page 8
    mode Problem Implication Intel® RSTe mode is not supported on Red Hat* Linux and SUSE* Linux. User may not be able to install Red Hat* Linux and SUSE* Linux on Intel® C600 Series Chipset based Server Boards under Intel® RSTe mode. Status This issue may be fixed in a future driver or BIOS release
  • Intel W2600CR | Specification update - Page 9
    Enterprise Platforms and Services Marketing Monthly Specification Update Implication Status Workaround User may not be able to install UEFI OS under the ESRT2 mode on Intel® C600 Series Chipset based Server Boards This issue may be fixed in a future BIOS revision. None. 4. HDD status LEDs do not
  • Intel W2600CR | Specification update - Page 10
    None. 9. System may halt under unsupported configuration in ESRT2 mode Problem If no Intel ® C600 RAID upgrade key (any of RKSAS4, RKSAS4R5, RKSAS8, RKSAS8R5) is installed to enable SAS support capablity under the ESRT2 mode and SAS drivers are used, the system may halt at the boot stage
  • Intel W2600CR | Specification update - Page 11
    Enterprise Platforms and Services Marketing Workaround None. Monthly Specification Update 10. Extra events may be seen in the System Event Log (SEL) during system global reset Problem The BMC may sporadically log extra reset event during a system DC reset (global reset). These events may appear
  • Intel W2600CR | Specification update - Page 12
    BMC Web Console and then return to the Power Control Page. The Perform Action button will then be available. 14. IPMI Get Chassis Status command returns incorrect Chassis Identify State Problem When a Get Chassis Status command is issued, after the Chassis Identify LED has been forced on, the
  • Intel W2600CR | Specification update - Page 13
    Enterprise Platforms and Services Marketing Monthly Specification Update 15. The BIOS and ME Firmware can't be updated successfully via Intel® One Boot Flash Update Utility(OFU) under SuSE Linux Enterprise Server 11* (64-bit) with SP2 Problem OFU will fail to update BIOS & ME under SuSE Linux
  • Intel W2600CR | Specification update - Page 14
    Update Enterprise Platforms and Services Marketing 18. Bios/ME cannot update using OFU utility after S3 resume on P4000CR System Problem BIOS/ME update under OS will fail after S3 resume. Implication Can not update Bios and ME with OFU utility. Status This issue was fixed in Bios
  • Intel W2600CR | Specification update - Page 15
    Platforms and Services Marketing Monthly Specification Update 21. Intel® LAN driver installation failure on Windows* 7 Problem The Intel® LAN driver version 16.8 and below may not be installed sucessfully on Windowns* 7 with the .bat installation scripts in the driver package. Implication
  • Intel W2600CR | Specification update - Page 16
    and Services Marketing Workaround Need to install internal video cable to boot up system first then disable onboard video option in Bios. 24. On-board VGA cannot be set to the highest resolution (1920x1080 and higher). Problem The Graphics ID register in the on-board video controller is
  • Intel W2600CR | Specification update - Page 17
    Enterprise Platforms and Services Marketing Documentation Changes None. Monthly Specification Update 13