Invacare SRX-20SP Owners Manual

Invacare SRX-20SP Manual

Invacare SRX-20SP manual content summary:

  • Invacare SRX-20SP | Owners Manual - Page 1
    Invacare® AVIVA® Storm RX SRX-20R, SRX-20SP, SRX-20MP en Power Wheelchair Base User Manual This manual MUST be given to the user of the product. BEFORE using this product, this manual MUST be read and saved for future reference.
  • Invacare SRX-20SP | Owners Manual - Page 2
    in This Manual 4 1.3 Type of Use 4 1.3.1 Prescription Statement 4 1.4 Intended Use 4 1.5 Indication for Use 4 1.6 Shelf Life 4 1.7 Service Life 5 Batteries 31 7.4.1 General Information on Charging 31 7.4.2 General Instructions on Charging 31 7.4.3 How to Charge the Batteries 31
  • Invacare SRX-20SP | Owners Manual - Page 3
    /Installing the Rear Shroud Assembly 47 10.5 Battery Service 48 10.5.1 General Instructions on Handling the Batteries 48 10.5.2 How to 52 11 After Use 53 11.1 Reuse 53 11.2 Disposal 53 12 Troubleshooting 54 12.1 Driving Performance 54 12.2 Control System 54 12.2.1 Battery
  • Invacare SRX-20SP | Owners Manual - Page 4
    read the user manual carefully and follow the safety instructions. Before reading this manual, make sure you carried out by your Invacare qualified service technician. Refer to the Inspection checklists tips, recommendations and information for efficient, trouble-free use. Identifies required tools,
  • Invacare SRX-20SP | Owners Manual - Page 5
    after regular use then the useful life of the batteries will be shortened. 1.7 Service Life The expected service life is five years, presuming that the product is used daily and in accordance with safety instructions, maintenance instructions and intended use, stated in this manual. 5 60127229-A
  • Invacare SRX-20SP | Owners Manual - Page 6
    this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as user manual, service manuals or instruction sheets supplied with this product or optional equipment. WARNING! Risk of Death, Injury
  • Invacare SRX-20SP | Owners Manual - Page 7
    power wheelchair, charge the batteries following the guidelines in this user manual. -DO NOT use the wheelchair with depleted batteries. WARNING! trap. Contact your Invacare provider for more information about maintaining and troubleshooting the Sip-n-Puff system. 7 WARNING! Risk of Injury, Damage
  • Invacare SRX-20SP | Owners Manual - Page 8
    This section contains information useful when making travel arrangements for your power wheelchair. Before Traveling Contact your travel carrier and/or tour guide about your travel plans and provide information about your intent to travel with your power wheelchair. The carrier will let you know
  • Invacare SRX-20SP | Owners Manual - Page 9
    Invacare® AVIVA® Storm RX Batteries l Number: 2 l Type: GP24 l Chemistry: Sealed VRLA Gel l Operating Voltage: 24V nominal (2 x 12 V) l GP24 Battery weight: approximately 51.5 lbs (23.4 kg) per battery l GP24 Amp-Hour Rating: 73.6 Ah (C20) (63 Ah (C5)) l Circuit breaker: 63 Amps, 5 KA rated break
  • Invacare SRX-20SP | Owners Manual - Page 10
    Secure or remove fragile components prior to transporting the wheelchair. The wheelchair controls can often be folded in towards the center of the chair. Wrap sensitive components (electronics, etc.) in soft, shock-absorbing material (foam, bubble wrap, towel, etc.). Ensure cables are secured.
  • Invacare SRX-20SP | Owners Manual - Page 11
    , cassette players, and small appliances, such as electric shavers and hair dryers, so far as we know, are not likely to cause EMI problems to your powered mobility device. 3.2 Powered Wheelchair Electromagnetic Interference (EMI) Because EM energy rapidly becomes more intense as one moves closer to
  • Invacare SRX-20SP | Owners Manual - Page 12
    Invacare® AVIVA® Storm RX WARNING! -DO NOT operate handheld transceivers (transmitters receivers), such as citizens band (CB) radios, or turn ON personal communication devices, such as cellular phones, while the mobility device is turned ON; -Be aware of nearby transmitters, such as radio or TV
  • Invacare SRX-20SP | Owners Manual - Page 13
    Invacare® AVIVA® Storm RX Voltage dips, short interruptions and voltage variations on power supply input lines 95 % dip in UT) for 0,5 cycle IEC 61000-4-11 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles 95 % dip in UT) for 5 s Power frequency (
  • Invacare SRX-20SP | Owners Manual - Page 14
    Invacare® AVIVA® Storm RX NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters,
  • Invacare SRX-20SP | Owners Manual - Page 15
    Invacare® AVIVA® Storm RX 4 Components 4.1 Component Overview The powered seating system is operated from the remote. Refer to the remote manual for more information. The powered seating system may include the following functions, depending on the modules installed: l Tilt l Recline 4.4 Labels on
  • Invacare SRX-20SP | Owners Manual - Page 16
    Invacare® AVIVA® Storm RX D 60101921 Fig. 4-7 Weight Capacity Label-Non-Elevate WEIGHT CAPACITY 300 lb (136 kg). Refer to User Manual. E 1167424 Fig. 4-8 Replacing Motor/Gearbox Label Fig. 4-3 Battery Wiring Label Location ITEM PART NUMBER DESCRIPTION A 1190611 Fig. 4-4 Serial Number
  • Invacare SRX-20SP | Owners Manual - Page 17
    be followed, otherwise injury and/or damage may occur. Fig. 4-17 Contact/Consult Manual Label READ MANUAL - Before M 60101926 using this product, read and understand the User Manual. The user manual provides proper operation and safe practices. Documentation can be obtained at the addresses listed
  • Invacare SRX-20SP | Owners Manual - Page 18
    V 60129679 Fig. 4-21 Magnetic Resonance (MR) Unsafe Label * Label located under the controller. ** Labels located under rear shroud. Wheelchairs with the Transport Ready Option - ISO 7176-19 Invacare® AVIVA® Storm RX ITEM PART DESCRIPTION NUMBER Q 1195716 Fig. 4-24 ISO 7176-19 NonCompliance
  • Invacare SRX-20SP | Owners Manual - Page 19
    on the Labels Refer to the following table for an explanation of the symbols on the labels. Symbol Description ISO 7000:2175 Seat Weight Read Manual Symbol is on a BLUE mandatory action background. Push position of motor lock. In this position the motor is disengaged and the wheels turn freely
  • Invacare SRX-20SP | Owners Manual - Page 20
    ASTM F2503 Magnetic Resonance (MR) Unsafe This device poses unacceptable risks to the patient, medical staff, or other persons within the MR environment. DANGER! Risk of Death, Injury, or Damage Danger indicates a imminently hazardous situation which, if not avoided, could result in death or serious
  • Invacare SRX-20SP | Owners Manual - Page 21
    to suit your personal body structure needs and preference. Thereafter weekly, monthly and periodic inspections should be performed by user/attendant between the six month service inspections. Refer to 9 Maintenance, page 40. 21 60127229-A
  • Invacare SRX-20SP | Owners Manual - Page 22
    attention of the wheelchair user as well as the assistant. This manual points out the most common procedures and techniques involved in the safe starts smoking, sparking, or burning, discontinue using the wheelchair and seek service IMMEDIATELY. Invacare® AVIVA® Storm RX DANGER! Risk of Death or
  • Invacare SRX-20SP | Owners Manual - Page 23
    body movement) or sleeping problems may cause injury, damage loose, contact a qualified technician for instructions. WARNING! Risk of Injury or damage or death. -Seek immediate attention and service if wheelchair is involved in a collision or are used for hand-hold supports. When learning a new
  • Invacare SRX-20SP | Owners Manual - Page 24
    using an escalator. -Observe and follow all safety warnings. -Use instructions provided for safe transportation between floors. WARNING! Risk of Injury that only secure, non-detachable parts are used for hand-hold supports. 4. Use safe lifting techniques. 5. Using non-removable (non-detachable
  • Invacare SRX-20SP | Owners Manual - Page 25
    change the normal balance, center of gravity or weight distribution of the wheelchair causing injury or damage. -Observe and follow all instructions and warnings regarding reach, weight, balance and positioning. -Determine and establish your particular safety limits. Practice bending, reaching and
  • Invacare SRX-20SP | Owners Manual - Page 26
    not suitable for wheelchairs. -DO NOT attempt to pass curbs/obstacles that are greater than the maximum climbable obstacle height. -Follow all instructions regarding negotiating curbs, obstacles and inclines. Maximum climbable obstacle height is listed in 13 Technical Data, page 56. CAUTION! Risk of
  • Invacare SRX-20SP | Owners Manual - Page 27
    Invacare® AVIVA® Storm RX 6.2.4 Negotiating Inclines Acceptable Incline Angles 0° to 9° Avoid Inclines of 10° and above Fig. 6-3 Fig. 6-4 Fig. 6-5 Fig. 6-6 27 WARNING! Risk of Injury, Damage or Death Loss of traction or stability on inclines/grades or ramps may cause injury, damage or death
  • Invacare SRX-20SP | Owners Manual - Page 28
    DANGER! Risk of Death or Serious Injury Traveling down inclines in reverse could cause the wheelchair to tip over resulting in death or serious injury -DO NOT travel down inclines in reverse. 6.2.5 Reaching, Leaning and Bending - Forward Many activities require the wheelchair user to reach, bend and
  • Invacare SRX-20SP | Owners Manual - Page 29
    when the remote is switched off. When pushing the mobility device manually while freewheeling, the motor locks must be disengaged. Pushing the the mobility device over short distances. The push handles or push bars support this function, but be aware that there might be some interference between the
  • Invacare SRX-20SP | Owners Manual - Page 30
    overheat. In this case, the wheelchair performance is gradually reduced until it stops. The status display shows a corresponding error code (refer to the user manual for your remote). By switching the power supply off and back on again, the error code is cleared and the controls system is switched
  • Invacare SRX-20SP | Owners Manual - Page 31
    be used to switch off the power supply of your mobility device manually, when the mobility device is transported without surveillance, for example a memory effect like NiCd batteries. 7.4.2 General Instructions on Charging Follow the instructions listed below to ensure safe use and longevity of
  • Invacare SRX-20SP | Owners Manual - Page 32
    MUST be performed within 24 hours of powering on the wheelchair. The Battery Synchronization Procedure can be found in the LiNX service manual and must be performed by a provider or qualified technician. l Charging existing batteries-Switch off the mobility device. 2. Connect the battery charger
  • Invacare SRX-20SP | Owners Manual - Page 33
    the remote. 7.4.5 Storage and Maintenance Follow the instructions listed below to ensure safe use and longevity be used. -Use batteries listed in this manual for proper replacement. Failure to use the charger information prior to installing, servicing or operating your wheelchair. 1. Position
  • Invacare SRX-20SP | Owners Manual - Page 34
    ask the transport company regarding each individual case. 7.4.9 General Instructions on Handling the Batteries l The batteries reach their end drive range is significantly smaller than usual. Contact your provider or service technician for details. l Always have your batteries installed by a
  • Invacare SRX-20SP | Owners Manual - Page 35
    19. -Only use the transport brackets for the purposes described in this manual. 8.2 Transport Ready Option (TRRO) As of this date, governmental regulatory , Damage or Death Failure to observe and follow transport warnings and instructions may result in injury, damage or death. -Only use the transport
  • Invacare SRX-20SP | Owners Manual - Page 36
    . -If the mobility device with the user has to be transferred to a vehicle using a ramp, ensure the ramp is properly secured. Refer to the ramp instructions. Ensure that the ramp does not exceed the rated slope (refer to 13 Technical Data, page 56). -If the mobility device has to be transferred
  • Invacare SRX-20SP | Owners Manual - Page 37
    's intended direction of travel. -The mobility device must always be secured in accordance with the mobility device and anchoring system manufacturers' user manual. -Always remove and secure any accessory parts fixed to the mobility device such as chin controls or tables. -If your mobility device
  • Invacare SRX-20SP | Owners Manual - Page 38
    at the front and two at the rear). 2. Secure the mobility device by tensioning the belts in accordance with the tie-down system manufacturer's user manual. 8.5.2 How The User is Secured Within the Mobility Device Invacare® AVIVA® Storm RX CAUTION! Risk of injury if the user is not properly secured
  • Invacare SRX-20SP | Owners Manual - Page 39
    with Invacare that provide transportation docking systems as a means for securing a power wheelchair inside of a motor vehicle. Please refer to the instructions for proper use provided by the docking system manufacturer. CAUTION! Risk of injury Invacare has not tested this power wheelchair for
  • Invacare SRX-20SP | Owners Manual - Page 40
    defect in workmanship. Refer to the Warranty section in this manual for specific warranty information. Refer to the Inspection Checklists for proper your wheelchair to a qualified technician for a thorough inspection and servicing. Weekly, monthly, and periodic inspections should be performed by
  • Invacare SRX-20SP | Owners Manual - Page 41
    pan, back cane and angle adjustment fasteners, and the arm support, flip back and height adjustment fasteners. Ensure fasteners are 9.3 Service Inspection Information Every six months take your wheelchair to a qualified technician for a thorough inspection and servicing. Service inspections
  • Invacare SRX-20SP | Owners Manual - Page 42
    moisture or cleaning may reduce the flame retardancy of the upholstery and may result in injury, damage or death. -Follow all cleaning instructions. -Avoid excessive moisture or cleaning. Regular cleaning will reveal loose or worn parts and enhance the smooth operation of your wheelchair. To
  • Invacare SRX-20SP | Owners Manual - Page 43
    Invacare® AVIVA® Storm RX psi bar 25 1.7 26 1.8 28 1.9 29 2.0 30 2.1 32 2.2 33 2.3 35 2.4 36 2.5 38 2.6 39 2.7 41 2.8 44 3.0 43 60127229-A
  • Invacare SRX-20SP | Owners Manual - Page 44
    10.1 Safety Information This section of the user manual provides service instructions for this product. All procedures in this section MUST be performed by a qualified technician/provider. -USERS/CAREGIVERS - If necessary, contact Invacare for a list of providers. -
  • Invacare SRX-20SP | Owners Manual - Page 45
    any medical devices such as ventilators, life support machines, etc. directly to the batteries used falling or fire. -Follow the maintenance instructions in this manual. -Routinely inspect the gearbox for grease hardware is securely tightened after setup, service or adjustments. -Warranty is void if
  • Invacare SRX-20SP | Owners Manual - Page 46
    your personal body structure needs and preference. Thereafter weekly, monthly and periodic inspections should be performed by user/attendant between the six month service inspections. Refer to Chapter 9 Maintenance, page 40. Check all parts for shipping damage. In case of damage, DO NOT use. Ensure
  • Invacare SRX-20SP | Owners Manual - Page 47
    and angle adjustment fasteners, and the arm support, flip back and height adjustment fasteners. Ensure fasteners are securely tightened. Refer to the seating system service manual for torque specifications and tightening instructions. Inspect TRBKTS fasteners and hardware. Inspect foam handgrips
  • Invacare SRX-20SP | Owners Manual - Page 48
    Reverse these steps to install the rear shroud assembly. 10.5 Battery Service 10.5.1 General Instructions on Handling the Batteries l The batteries reach their end of life when by a qualified technician. Read the installation instructions noted on the battery and in the manual. 60127229-A 48
  • Invacare SRX-20SP | Owners Manual - Page 49
    Invacare® AVIVA® Storm RX Ensure there is no ba�ery acid in the bo�om or around the ba�ery box or on the sides of the ba�ery(ies). Neutralize ba�ery acid with baking soda if found. Clean ba�ery tray and ba�eries prior to installa�on. Use ba�ery li�ing strap when available. Keep ba�eries in an
  • Invacare SRX-20SP | Owners Manual - Page 50
    powering on the wheelchair. Otherwise the battery gauge will not display accurate battery charge levels. The Battery Synchronization Procedure can be found in the LiNX service manual and must be performed by a provider or qualified technician. 60127229-A 50
  • Invacare SRX-20SP | Owners Manual - Page 51
    Invacare® AVIVA® Storm RX 10.5.6 Replacing Battery Cables 3/8 inch (6 pt) Box Torque Wrench WARNING! Risk of Death or Serious Injury Failure to observe these warnings can cause an electrical short resulting in death, serious injury, or damage to the electrical system. -The POSITIVE (+) battery
  • Invacare SRX-20SP | Owners Manual - Page 52
    10.5.7 Cleaning Battery Terminals WARNING! Risk of Injury Exposure to battery acid may result in injury. -The use of rubber gloves is recommended when working with batteries. -DO NOT allow the liquid in the battery to come in contact with skin, clothes or other possessions. It is a form of acid and
  • Invacare SRX-20SP | Owners Manual - Page 53
    new user, carry out the following actions: l Clean the product. Refer to Chapter 9 Maintenance, page 40. l Inspection according to service plan. Consult service instructions, available from Invacare. l Adaptation to the user. Refer to Chapter 5 Setup, page 21. 11.2 Disposal l The equipment wrapping
  • Invacare SRX-20SP | Owners Manual - Page 54
    System For additional troubleshooting information and explanation of error codes, refer to the individual remote (joystick) manual supplied with each if necessary. Contact Provider/Invacare for Service. Contact Provider/Invacare for Service. malfunction. Battery indicator flashes the charge
  • Invacare SRX-20SP | Owners Manual - Page 55
    your convenience and safety. DON'T DO Don't perform any installation or maintenance without first reading this manual. Read and understand this manual and any service information that accompanies a battery and charger before operating the wheelchair. Don't perform installation or maintenance of
  • Invacare SRX-20SP | Owners Manual - Page 56
    Invacare® AVIVA® Storm RX 13 Technical Data 13.1 Technical Specifications The technical information provided hereafter applies to a standard configuration or represents maximum achievable values. These can change if accessories are added. The precise changes to these values are detailed in the
  • Invacare SRX-20SP | Owners Manual - Page 57
    Invacare® AVIVA® Storm RX Drive wheels Forks Casters l Black with rim inserts, 14 x 3" l Black tires with gel foam inserts or pneumatic tires The recommended maximum tire pressure in bar or kpa is marked on the side wall of the tire or the rim. If more than one value is listed, the lower one in
  • Invacare SRX-20SP | Owners Manual - Page 58
    Invacare® AVIVA® Storm RX Dimensions according to ISO 7176-15 Total length (including centermounted front rigging) l 47.6 in (1210 mm) at 0° Ground clearance l 2.8 in (71 mm) l 3.2 in (81 mm) under battery box Horizontal location of axle4 l 0.5 in (12.7 mm) Weight5 Total mass 385lb (175 kg)
  • Invacare SRX-20SP | Owners Manual - Page 59
    Invacare® AVIVA® Storm RX Other Specifications Lateral dynamic stability while turning in a circle: Lateral dynamic stability while turning suddenly: 66.9 in (1700 mm) - 74.8 in (1900 mm) Yes 1 IPX4 classification means that the electrical system is protected against spray water. IPX1
  • Invacare SRX-20SP | Owners Manual - Page 60
    to the specific wheelchair being disclosed. For example, parts of the table apply only to powered wheelchairs and therefore would not apply to manual wheelchairs. * Folded length, Folded width and Folded height are only required for wheelchairs which have folding frames. ** Handrim diameter is only
  • Invacare SRX-20SP | Owners Manual - Page 61
    , please contact the provider from whom you purchased your product. In the event you do not receive satisfactory Warranty service, please write directly to Invacare at the address on the bottom of the back cover. Provide provider's name address, date of purchase, indicate nature of
  • Invacare SRX-20SP | Owners Manual - Page 62
    control, and such evaluation will be solely determined by Invacare. The Warranty does not apply to problems arising from normal wear and tear or failure to adhere to the product instructions. A change in operating noise, particularly relative to motors and gearboxes does not constitute a failure or
  • Invacare SRX-20SP | Owners Manual - Page 63
    Notes
  • Invacare SRX-20SP | Owners Manual - Page 64
    Invacare Corporation USA Canada Australia New Zealand One Invacare Way, Elyria, OH 44035, USA • 800-333-6900 • www.invacare.com 570 Matheson Blvd E Unit 8, Mississauga, Ontario, L4Z 4G4 Canada • 800-668-5324 • www.invacare.ca Invacare Australia PTY. Ltd., 1 Lenton Place, North Rocks NSW 2151
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

Invacare® AVIVA® Storm RX
SRX-20R, SRX-20SP, SRX-20MP
en
Power Wheelchair Base
User Manual
This manual MUST be given to the user of the product.
BEFORE using this product, this manual MUST be read and saved for future reference.