Jenn-Air JXI8036WS Dimension Guide

Jenn-Air JXI8036WS Manual

Jenn-Air JXI8036WS manual content summary:

  • Jenn-Air JXI8036WS | Dimension Guide - Page 1
    42" (106.7 cm) Island Canopy Range Hood PRODUCT MODEL NUMBERS JXI8036W JXI8042W pressure and air turbulence that support must be attached to joists. If this is not possible, you must build a support structure behind the plaster or drywall. The support structure must be able to support Instructions
  • Jenn-Air JXI8036WS | Dimension Guide - Page 2
    *46¹⁄₂" (118.0 cm) max. **52 133.5 cm) max. 36" (91.2 cm) 42" (106.4 cm) 27" (68.6 cm) *Vented installations only **Non-vented (recirculating) installations only to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without
  • 1
  • 2

PRODUCT MODEL NUMBERS
JXI8036W
JXI8042W
ELECTRICAL REQUIREMENTS
• A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical circuit is required.
VENTING METHODS
This island hood is factory set for venting through the roof.
An 8" (20.3 cm) round vent system is needed for installation (not included). The
hood exhaust opening is 8" (20.3 cm) round.
NOTE:
Flexible vent is not recommended. Flexible vent creates back pressure and
air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a
wall, a 90° elbow is needed.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood
can be used in the non-vented (recirculating) version, fitting a charcoal filter and
the deflector. Fumes and vapors are recycled through the top grille.
NOTE:
Wall venting can be an option for 2-story homes.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters)
for each vent piece used in the system.
36" (91.4 cm) and 42" (106.7 cm) Island Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10274319E
12/16/09
Roof Venting
Non-vented (recirculating)
A. Roof cap
B. 8" (20.3 cm) round vent
A. Deflector
B. 8" (20.3 cm) round vent
A
B
A
B
Example vent system
The following example falls within the maximum recommended vent
length of 35 ft (10.7 m).
LOCATION REQUIREMENTS
IMPORTANT:
Observe all governing codes and ordinances. Have a
qualified technician install the range hood. It is the installer's
responsibility to comply with installation clearances specified on the
model/serial rating plate. The model/serial rating plate is located behind
the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as
windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical Requirements”
section.
Because of the size and weight of this island hood, the chimney support
must be securely attached to the ceiling.
• For plaster or drywall ceilings, the chimney support must be attached
to joists. If this is not possible, you must build a support structure
behind the plaster or drywall. The support structure must be able to
support 80 lbs (36.6 kg).
The range hood is factory set for venting through the roof.
For non-vented (recirculating) Installation see “Non-vented
(recirculating) Installations” in “Install Range Hood” section.
Recirculation Kit Part Number W10272061 is available from your dealer
or an authorized parts distributor.
All openings in ceiling and wall where range hood will be installed must
be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured
Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly
the Federal Standard for Mobile Home Construction and Safety, Title 24,
HUD, Part 280) or when such standard is not applicable, the standard
for Manufactured Home Installation 1982 (Manufactured Home Sites,
Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or
with local codes.
Vent Piece
8" (20.3 cm) Round
45° elbow
2.5 ft (0.8 m)
90° elbow
5.0 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
Length of system
= 13.0 ft (3.9 m)
90
elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
Page 1 of 2