Kenmore 9410 Installation Instructions

Kenmore 9410 - 30 in. Electric Range Manual

Kenmore 9410 manual content summary:

  • Kenmore 9410 | Installation Instructions - Page 1
    INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. INSTALLER. Clearances and Dimensions 1. Provide adequate clearances between the range and adjacent combustible surfaces. 2.
  • Kenmore 9410 | Installation Instructions - Page 2
    the Consumer Keep these instructions with your owner's guide for future reference. As when using any appliance generating heat, there are certain safety precautions you should follow. These are listed in the Use & Care Manual. read it carefully. Be sure your range is installed and grounded properly
  • Kenmore 9410 | Installation Instructions - Page 3
    could create a potential electrical hazard if wires become pinched. Connect only as instructed under'WIRING INSTRUCTIONS" in section 4A or 4B. When using flexible conduit or range cable use flex connector or range cable strain relief. NOTE: Only use copperwire in connectionto terminal block. Floor
  • Kenmore 9410 | Installation Instructions - Page 4
    Power Supply Cord Kit RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF AN INCORRECT SIZE RANGE CORD KIT IS USED, THE INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED OR STRAIN RELIEF BRACKET IS DISCARDED. Range Connection Opening Size Chart Supply Cord Kit ampere rating information. See serial plate on
  • Kenmore 9410 | Installation Instructions - Page 5
    be connected to the center terminal. 3. Make sure all nuts are tightened securely. 4. Replace the rear access cover. GROUNDING INSTRUCTIONS: A ground link is installed on this range which connects the center terminal of the terminal block (neutral) to the chassis. The ground link is not visible in
  • Kenmore 9410 | Installation Instructions - Page 6
    servicingandcleaning. Reinstallinreverseordermaking sure to level the range and check electrical connections. See pages 2 and 3 for proper anchoring instructions. Before You Call for Service Read the "Before You Call" and operating instruction sections in your Use & Care Manual. It may save you time
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

INSTALLATION
AND
SERVICE
MUST
BE
PERFORMED
BY A QUALIFIED
INSTALLER.
IMPORTANT:
SAVE
FOR
LOCAL
ELECTRICAL
INSPECTOR'S
USE.
READ
AND
SAVE
THESE
INSTRUCTIONS
FOR
FUTURE
REFERENCE.
Clearances
and Dimensions
1.
Provide adequate clearances between the range and adjacent combustible surfaces.
2.
Location--Check
location where the range will be installed. Check for proper electrical supply, and the stability
of the floor.
3.
Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must
be solid and level.
SidoevOf3r_ng:ight"
__-_
®o
1_
e_hraenrgied
e
SIDE
VIEW
Maximum depth
fa_ro_ab_nne_Se
top.
_25"--_
i
:ii! iii:
i
30"
_
0' clearance below
cooking
top
and
at
rear of range.
RANGE
OVERALL
DIMENSIONS
253/4'
p-
30
44
5/8'
_
Door
Open
_
9
/
,,_
....
ak_>
Centerline
of
range
outlet
location
are maximum,
Dashed
cubed
area
shows where
the
electrical
outlet must be
installed
for
flush to
the wall installation
/
Wall
-_.._Edge
2-5/8"
for models equipped
"'"
with
warmer drawers"
3-1/2" for
models equipped
with
storage
drawers
*30"
MINIMUM
CLEARANCE
BETWEEN
THE TOP
OF THE COOKING
SURFACE
AND THE
BOTTOM
OF AN
UNPROTECTED WOOD OR METAL CABINET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS
PROTECTED BY NOT LESS THAN 1/4" FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28
MSG SHEET STEEL, 0.015" STAINLESS STEEL, 0.024" ALUMINUM
OR 0.020" COPPER. O" CLEARANCE
IS THE
MINIMUM
FOR THE REAR OF THE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS
PROVIDED ABOVE TO
PREVENT PROPERTY DAMAGE, POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE
SPACE
LOCATED
ABOVE
THE SURFACE
UNITS
SHOULD
BE AVOIDED.
IF CABINET
STORAGE
IS TO
BE
PROVIDED, THE RISK CAN BE REDUCED
BY
INSTALLING
A RANGE
HOOD THAT PROJECTS HORIZONTALLY A
MINIMUM OF 5" BEYOND THE BOTTOM OF THE CABINETS.
Fran_ais-
Pages7-12
Espa5ol- Pbginas 13-18
PIN 316259200
(0104)
1