Kenwood KXF-W6010 User Manual

Kenwood KXF-W6010 Manual

Kenwood KXF-W6010 manual content summary:

  • Kenwood KXF-W6010 | User Manual - Page 1
    STEREO CASSETTE DECK CT/KXF-W SERIES CT-203 KXF-W4010 CT-2050 KXF-W6010 INSTRUCTION MANUAL KENWOOD CORPORATION This manual contains instructions for four models. Model availability and features (functions) may differ depending on country and sales area. SI DICHIARA CHE : gli apparecchi
  • Kenwood KXF-W6010 | User Manual - Page 2
    Introduction 2 Before applying power CT-2050/203/KXF-W6010/W4010 (En/M) Caution : Read this section carefully to ensure safe operation. Units are designed TO ALERT THE USER TO THE PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE APPLIANCE.
  • Kenwood KXF-W6010 | User Manual - Page 3
    you transport or ship the unit in the future. Keep this manual handy for future reference. Accessories Check that the following accessories are 15 How to record (CT-203/KXF-W4010; Deck B only) .. 16 Normal recording 16 Relay recording (CT-2050/KXF-W6010 only 19 Relay recording 19 Tape dubbing
  • Kenwood KXF-W6010 | User Manual - Page 4
    to clean the cabinet. Use a clean dry cloth. CT-2050/203/KXF-W6010/W4010 (En/M) Caution against contact revitalizer Do not use contact cleaners because roller Tape guides Cleaning the heads and peripheral components For maintaining the best condition of the deck and for longer service life, always
  • Kenwood KXF-W6010 | User Manual - Page 5
    the safety tab, to prevent the recorded contents from being erased or recorded on accidentally. For A side For B side Important items CT-2050/203/KXF-W6010/W4010 (En/M) 5 To store cassette tapes Do not store the tapes in a place which is subject to direct sunlight, or near equipment that generates
  • Kenwood KXF-W6010 | User Manual - Page 6
    shown below. When connecting the 6 related system components, refer also to the instruction manuals of the related components. Caution: Do not plug in the power lead until all connections are completed. CT-2050/203/KXF-W6010/W4010 (En/M) Malfunction of microcomputer If operation is not possible or
  • Kenwood KXF-W6010 | User Manual - Page 7
    KXF-W6010/W4010 (En/M) 7 ABOUT THE SYSTEM CONTROL CONNECTIONS Connecting system control cords after connecting a KENWOOD audio component system lets you take advantage of convenient system control operations. There are two KENWOOD the [XS8] mode, follow the instructions in "SWITCHING FROM [SL16] TO
  • Kenwood KXF-W6010 | User Manual - Page 8
    indicators DUBBING indicators NORMAL HIGH DOLBY NR indicators Display AUTO BIAS indicator Deck B COUNTER indicators 1 2 CT-2050/KXF-W6010 3 4 0 0 STEREO DOUBLE CASSETTE DECK KXF-W6010 AUTO REVERSE A TAPE 8PAUSE ¶REC/ARM 1 ¡ RESET A DOLBY NR REV.MODE RELAY REC NORM.DUBB. HIGH DUBB
  • Kenwood KXF-W6010 | User Manual - Page 9
    recording pause after leaving a non-recorded blank of 4 seconds. ! Deck A PAUSE (8) key (CT-2050/ KXF-W6010 only) ! Press to let tape transport pause tem- porarily. @ Deck A REC/ARM (¶) key (CT-2050/ KXF-W6010 only) ^ Press in stop mode to start recording or press in record mode to let
  • Kenwood KXF-W6010 | User Manual - Page 10
    Preparation for playback (recording) Before playback (recording) 10 1 Set the TIMER switch to OFF. TIMER REC OFF PLAY CT-2050/203/KXF-W6010/W4010 (En/M) 2 Set the POWER switch to ON. POWER -ON -OFF : Keys and control used in the operations described on this page. Playback (recording)
  • Kenwood KXF-W6010 | User Manual - Page 11
    winding in the \ direction. 1 ¡ ÷ Press the stop (7) key to stop fast tape winding. To pause playback (CT-203/KXF-W4010; Deck B only) CT-2050/KXF-W6010 CT-203/KXF-W4010 8PAUSE ÷ The 8 indicator lights. Usage of counter Before starting recording (playback), press the RESET A or RESET B key to
  • Kenwood KXF-W6010 | User Manual - Page 12
    This function plays back the tapes in both decks A and B 12 continuously and repeatedly. Listening to cassette tape CT-2050/203/KXF-W6010/W4010 (En/M) Relay playback 1 Load cassette tapes in both decks. 1 Open the cassette holders of decks A and B. 0 2 Insert cassette tapes and close the cassette
  • Kenwood KXF-W6010 | User Manual - Page 13
    CT-2050/203/KXF-W6010/W4010 (En/M) 13
  • Kenwood KXF-W6010 | User Manual - Page 14
    Convenient music search (DPSS) CT-2050/203/KXF-W6010/W4010 (En/M) The DPSS (Direct Program Search System) enables the following convenient operations according to the instructions of the 14 operation keys (these operation are however not available on both decks simultaneously). The DPSS functions
  • Kenwood KXF-W6010 | User Manual - Page 15
    Convenient music search (DPSS) CT-2050/203/KXF-W6010/W4010 (En/M) Rewind & Play operation 15 This operation cannot be performed with the remote control (of the separately sold amplifier). Direction of tape direction indicator: 3. 1 ¡ 2 7 3
  • Kenwood KXF-W6010 | User Manual - Page 16
    the deck enters the stop mode. ÷ For a fine adjustment after setting AUTO BIAS, refer to the description of "Bias level adjustment". (CT-2050/KXF-W6010 only) & ÷ To cancel the auto-bias adjustment operation in the middle, press the stop (7) key. ÷ Recording is possible even when the auto-bias
  • Kenwood KXF-W6010 | User Manual - Page 17
    been recorded till the end. Bias level adjustment (Deck B of the CT-2050/KXF-W6010 only) The MODE key can be used to adjust the bias level. 1 Press "BIAS" lights up: Recording bias setting mode (Deck B of the CT-2050/KXF-W6010 only) 4 "LEVEL","BAL.",and "BIAS"go off: Counter display mode lights up
  • Kenwood KXF-W6010 | User Manual - Page 18
    transport. Recorded tune Re-recording Tune to be re-recorded. During recording in the 2 direction: 1 ¡ 2 Press the REC/ARM (¶) key twice. CT-2050/KXF-W6010 ¶REC/ARM CT-203/KXF-W4010 3 Replay the tune you wish to record. 4 Press the REC/ARM (¶) key once. ¶REC/ARM Blank of 4 sec. or more. ÷ If
  • Kenwood KXF-W6010 | User Manual - Page 19
    B. Since this unit is not designed for recording with metal (TYPE ) tapes, do not use metal tapes for recording. CT-2050/203/KXF-W6010/W4010 (En/M) 19 Preparation Make "Playback (recording) preparation". 0 (If relay recording is required, insert tapes in both decks A and B. Select the recording
  • Kenwood KXF-W6010 | User Manual - Page 20
    To pause dubbing For normal-speed dubbing. NORM.DUBB For high-speed dubbing. HIGH DUBB. CT-2050/KXF-W6010 NORMAL DUBBING CT-2050/KXF-W6010 HIGH DUBBING CT-203/KXF-W4010 CT-203/KXF-W4010 To stop dubbing Press the stop (7) key of Deck B. 2 7 3 ÷ Only deck B enters the record- pause mode
  • Kenwood KXF-W6010 | User Manual - Page 21
    Convenient CD recording (CT-203/KXF-W4010; Deck B only) CT-2050/203/KXF-W6010/W4010 (En/M) By connecting this unit with a KENWOOD "f", "ƒ", " (ƒ)", type amplifier (receiver) with a SYSTEM CONTROL jack 21 and a KENWOOD CD player with a SYSTEM CONTROL jack using system control cords, recording on
  • Kenwood KXF-W6010 | User Manual - Page 22
    recording (CT-203/KXF-W4010; Deck B only) CT-2050/203/KXF-W6010/W4010 (En/M) When connected with a KENWOOD amplifier,CD player provided to set the optimum recording level. If this occurs, carry out recording manually referring to the "Normal recording" section. ^ 5. The CCRS recording level
  • Kenwood KXF-W6010 | User Manual - Page 23
    FORWARD 3 Audio timer CT-2050/203/KXF-W6010/W4010 (En/M) To AC outlet 23 Tuner Amplifier (CT-2050/203/KXF-W6010/W4010) 2 Adjust the volume of automatically. ÷ Read carefully the instruction manual of your audio timer. Notes 1. When connecting the KENWOOD equipment (amplifier, CD player)
  • Kenwood KXF-W6010 | User Manual - Page 24
    starts. ÷ Recording stops when the end of side to be recorded is reached. ÷ Read carefully the instruction manual of your audio timer. Timer relay recording (CT-2050/KXF-W6010 only) 1 Press the MPX FILTER key to ON. & 2 Complete the procedure 1, 2, 3 of "Relay recording". ( 3 Complete the
  • Kenwood KXF-W6010 | User Manual - Page 25
    difficulty CT-2050/203/KXF-W6010/W4010 (En/M) What appears to be a malfunction may not always be serious. If your unit should not perform as expected, consult the table below to see if the problem can be corrected before seeking help from your dealer or service representative. 25 Operation to
  • Kenwood KXF-W6010 | User Manual - Page 26
    In case of difficulty CT-2050/203/KXF-W6010/W4010 (En/M) 26 Symptom Cause Remedy Recording is not initiated when the REC/ ARM (¶) key is pressed. ÷ The protection tab on the cassette has been
  • Kenwood KXF-W6010 | User Manual - Page 27
    CT-2050/203/KXF-W6010/W4010 (En/M) four types of simple playback operations according to the instructions given by pressing operation keys. (It is not possible Computer-controlled CD Recording System) ™ When connected with a KENWOOD amplifier,CD player provided with "f", "ƒ", " (ƒ)" marking
  • Kenwood KXF-W6010 | User Manual - Page 28
    (Net 4.6 kg (10.6 lb) CT-2050/203/KXF-W6010/W4010 (En/M) CT-203/KXF-W4010 Track System 4 track, 2 channel stereo Recording System (15-3/8") Weight (Net 4.6 kg (10.6 lb) 1. KENWOOD follows a policy of continuous advancements in development. For this service on this product. Model Serial Number
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

STEREO
CASSETTE DECK
CT/KXF-W SERIES
INSTRUCTION MANUAL
KENWOOD CORPORATION
B60-3706-00
HZ
( K, P, T, M, X, Y )
ID
99/3 2 1 98/12 11 10 9 8 7 6 5 4 3
CT-203
CT-2050
KXF-W4010
KXF-W6010
This manual contains instructions for four models.
Model availability and features
(functions) may differ depending on country and sales area.