Kenwood PS-60 Operation Manual 2

Kenwood PS-60 Manual

Kenwood PS-60 manual content summary:

  • Kenwood PS-60 | Operation Manual 2 - Page 1
    DC POWER SUPPLY PS-60 INSTRUCTION MANUAL We are grateful you purchased this KENWOOD DC Power Supply. SUPPLIED ACCESSORIES AC Power Cable (2 m/ 6.5 feet 1 Instruction Manual 1 Warranty Card 1 PRECAUTIONS • Do not expose the unit to rain or moisture to avoid the risk of fire or electric shock. • Do
  • 1

We are grateful you purchased this
KENWOOD
DC Power Supply.
SUPPLIED ACCESSORIES
AC Power Cable (2 m/ 6.5 feet)
........................................................
1
Instruction Manual
..........................................................................
1
Warranty Card
.................................................................................
1
PRECAUTIONS
Do not expose the unit to rain or moisture to avoid the risk of fire or
electric shock.
Do not touch the power plug when your hands are wet to avoid risk of
electric shock.
Do not remove the case. Accidentally touching an internal part may
result in serious electric shock.
If a metal object such as a hair pin or a needle comes into contact with
the power socket on the rear panel, a dangerous electric shock may
occur.
Keep children away from the unit, to avoid unnecessary risk of harm to
the child.
Always remove the plug from an AC outlet by pulling on the plug, not
the cable.
Position the AC cable so it will not be stepped on, tripped over, nor
subjected to damage.
Plug the AC cable only into a grounded AC outlet.
Unravel the AC power cord before use.
In case of an abnormality in the equipment, ensure the equipment is
plugged into an outlet that can be easily accessed, so that the plug
may be disconnected from the outlet.
To avoid equipment damage, do not connect to a transceiver that
operates on a voltage other than 13.8 V DC or exceeds the current
rating.
Do not expose the unit to long periods of direct sunlight, nor place it
close to heating appliances.
Do not place the unit in excessively dusty and/or humid areas, nor on
unstable surfaces.
Do not block the power supply air vent.Do not cover the unit. To
maintain good ventilation, place the unit at least 10 cm (4 inches) away
from the wall.
Do not use solvents such as benzene or paint thinner to clean the unit.
Use a silicone or a clean, dry cloth.
Do not install this equipment in a constricted location, such as a book
case.
If you detect an abnormal odor or smoke coming from the unit, turn
OFF the power immediately and disconnect the power cord.
Contact
your
KENWOOD
service center or dealer.
Information on Disposal of Old Electrical and Electronic Equipment (applicable
for countries that have adopted separate waste collection systems)
Products with the symbol (crossed-out wheeled bin) cannot be disposed as
household waste.
Old electrical and electronic equipment should be recycled at a facility
capable of handling these items and their waste byproducts.
Contact your
local authority for details in locating a recycle facility nearest to you.
Proper
recycling and waste disposal will help conserve resources whilst preventing
detrimental effects on our health and the environment.
B62-2332-40 (T)
DC POWER SUPPLY
INSTRUCTION MANUAL
PS-60
ORIENTATION
Front Panel
DC POWER SUPPLY
PS-60
Power switch
Press this switch to turn the power ON and OFF.
Rear Panel
This power supply is for use with a transceiver . Do not use the power
supply with other products.
Before connecting the DC power cable to the transceiver terminal, or
removing it from the terminal, turn the power supply power OFF.
For connection instructions, refer to the transceiver instruction manual.
When placing the power supply beside the transceiver, adjust the
power supply bail to an appropriate angle. You can further use
commercially available rubber pads/ feet to adjust the angle to match
that of the transceiver.
SPECIFICATIONS
Power requirements
....................
100 V ~ 240 V AC ±10%, 50/60 Hz
Output voltage
..........................................................
13.8 V DC ±5%
Rated output current
..............................................................
22.5 A
Operating temperature range
.......
–10°C ~ + 50°C (–22°F ~ +130°F)
Dimensions (W x H x D) <without projections>
......................
173.5 x 95.5 x 204.3 mm (6.83 x 3.76 x 8.04 in)
Dimensions (W x H x D) <with projections>
....................
175.9 x 108.6 x 228.1 mm (6.93 x 4.28 x 8.98 in)
Weight
............................................................
approx. 2.5 kg (5.5 lb)
AC Plug
.................................................................
3 pin (Grounded)
THE LIGHTNING FLASH WITH ARROWHEAD SYMBOL, WITHIN AN
EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE USER TO THE
PRESENCE OF UNINSULATED“DANGEROUS VOLTAGE”WITHIN THE
PRODUCT’S ENCLOSURETHAT MAY BE OF SUFFICIENT MAGNITUDE
TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS.
THE EXCLAMATION POINT WITHIN AN EQUILATERALTRIANGLE IS
INTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANT
OPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS IN THE
LITERATURE ACCOMPANYINGTHE APPLIANCE.
"+" Terminal
"−" Terminal
AC Power
Cable
Indicator
(Red)
(Output
monitor)
Power switch
Bail
Cooling Fan
The equipment is designed for connection to an IT power distribution
system.
© 2019