Kenwood TK 3200U2P Instruction Manual

Kenwood TK 3200U2P - Protalk UHF - Radio Manual

Kenwood TK 3200U2P manual content summary:

  • Kenwood TK 3200U2P | Instruction Manual - Page 1
    INSTRUCTION MANUAL PacTronics, Inc. 800-607-2243 www.pactronics.com VHF FM TRANSCEIVER TK-2200 UHF FM TRANSCEIVER TK-3200 © B62-1791-10 (K, K2) 09 08 07 06 05 04 03 02 01
  • Kenwood TK 3200U2P | Instruction Manual - Page 2
    your purchase of this KENWOOD product and welcome you to the Business Radio Service (BRS). Your KENWOOD 2-way Business Radio is called a COVERED BY THIS MANUAL TK-2200 (K): 2-channel VHF FM Transceiver TK-3200 (K): 2-channel UHF FM Transceiver TK-2200 (K2): 8-channel VHF FM Transceiver TK-3200 (K2):
  • Kenwood TK 3200U2P | Instruction Manual - Page 3
    6 miles (approximately 9.6 km) Up to 1.5 miles (approximately 2.4 km) Up to 250,000 square feet (approximately 23,220 m2) Up to 20 floors Note: The listed ranges are based on field testing and may vary with your operating conditions and individual transceiver. i
  • Kenwood TK 3200U2P | Instruction Manual - Page 4
    KENWOOD transceiver operates on communications frequencies which are subject to FCC (Federal Communications Commission) Rules & Regulations. FCC Rules require that all operators using Private Land Mobile radio frequencies obtain a radio 601 and instructions can be SPACING The TK-2200/ TK-3200 uses
  • Kenwood TK 3200U2P | Instruction Manual - Page 5
    transceiver. Contact your KENWOOD dealer. NOTICES TO THE USER ◆ Government law prohibits the operation of unlicensed radio transmitters within the territories under government control. ◆ Illegal operation is punishable by fine and/or imprisonment. ◆ Refer service to
  • Kenwood TK 3200U2P | Instruction Manual - Page 6
    may be applicable: FCC WARNING This equipment generates or uses radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment
  • Kenwood TK 3200U2P | Instruction Manual - Page 7
    streams, which is illegal in some areas. For information on Ni-MH battery recycling in your area, call (toll free) 1-800-8-BATTERY (1-800-822-8837). KENWOOD's involvement in this program is part of our commitment to preserve our environment and conserve our natural resources. v
  • Kenwood TK 3200U2P | Instruction Manual - Page 8
    25 CALLING ALERT 28 KEY LOCK 28 SUPER LOCK 28 MONITOR/ SQUELCH OFF 29 SCAN 29 SCRAMBLER 30 ALL RESET MODE 31 OPTIONAL ACCESSORIES 32 TROUBLESHOOTING GUIDE 33 vi
  • Kenwood TK 3200U2P | Instruction Manual - Page 9
    charger AC adaptor Ni-MH battery pack (KNB-29N) Speaker/ microphone jack cover Speaker/ microphone locking bracket Belt clip Screw set Warranty card Instruction manual Part Number Quantity W08-0969-XX 1 W08-0970-XX 1 W09-1000-XX 1 B09-0680-XX 1 J19-5472-XX 1 J29-0713-XX 1 N99-2043-XX
  • Kenwood TK 3200U2P | Instruction Manual - Page 10
    Rapid battery charger AC adaptor Ni-MH battery pack (KNB-29N) Speaker/ microphone jack cover Speaker/ microphone locking bracket Belt clip Screw set 2
  • Kenwood TK 3200U2P | Instruction Manual - Page 11
    ORIENTATION Antenna (optional) LED indicator Indicates the transceiver status. Lights red while transmitting, green while receiving, and flashes red while the battery power is low while transmitting. Channel selector Rotate to change the operating channel from 1 ~ 2 or 1 ~ 8. Power switch/ Volume
  • Kenwood TK 3200U2P | Instruction Manual - Page 12
    to overcharging. Note: ◆ The ambient temperature should be between 41°F and 104°F (5°C and 40°C) while charging is in progress. Charging outside this range may not fully charge the battery. ◆ Always switch OFF the transceiver equipped with a Ni-MH battery pack before charging. Using the transceiver
  • Kenwood TK 3200U2P | Instruction Manual - Page 13
    Plug the AC adaptor cable into the 1 adaptor jack located at the rear of the charger. 2 Plug the AC adaptor into an AC outlet. Slide the Ni-MH battery pack or transceiver with a Ni-MH battery pack into the charger. Make sure the battery pack terminals 3 are in contact with the charger
  • Kenwood TK 3200U2P | Instruction Manual - Page 14
    INSTALLING/ REMOVING THE BATTERY PACK The battery pack is not charged at the factory; charge it before use {pages 5 and 6}. Average battery pack life (calculated using 5% transmit time, 5% receive time, and 90% standby time) is 18 hours when using the dealer set Battery Save function, and 14 hours
  • Kenwood TK 3200U2P | Instruction Manual - Page 15
    retainer, nor a speaker/ microphone attachment point. Using the antenna in these ways may damage the antenna and degrade your transceiver's performance. INSTALLING THE BELT CLIP If necessary, attach the belt clip using the two supplied 3 x 8 mm screws. Note: If the belt clip is
  • Kenwood TK 3200U2P | Instruction Manual - Page 16
    INSTALLING THE COVER OVER THE SPEAKER/ MICROPHONE JACKS If you are not using a speaker/ microphone, install the cover over the speaker/ microphone jacks using the supplied 3 x 6 mm screw. Note: To keep the transceiver water resistant, you must cover the speaker/ microphone jacks with the supplied
  • Kenwood TK 3200U2P | Instruction Manual - Page 17
    GETTING STARTED 1 1 2 1 3 Turn the Power switch/ Volume control clockwise to switch the transceiver power ON. A beep sounds. Rotate the Channel selector to select your desired channel. When you receive an appropriate signal, you will hear audio from the speaker. Adjust the volume as necessary. To
  • Kenwood TK 3200U2P | Instruction Manual - Page 18
    VOICE OPERATED TRANSMISSION (VOX) Using the VOX feature, you can operate the transceiver hands-free. In order to use this feature, however, you must use an optional headset; VOX will not function with the built-in microphone. For best operating conditions, we recommend you use an optional headset
  • Kenwood TK 3200U2P | Instruction Manual - Page 19
    Press the Lock key to increase the VOX Gain level and the Scan key to decrease the level. 3 The VOX Gain can be adjusted from level 1 to level 10 and OFF. The transceiver announces the VOX Gain level as you adjust it. If OFF is selected, the transceiver announces "Off". Press the PTT switch
  • Kenwood TK 3200U2P | Instruction Manual - Page 20
    VOX OPERATION 1 Set up a VOX Gain level from 1 to 10 {page 10}. To transmit, simply speak into the headset microphone. 2 You do not need to press the PTT switch; the transceiver automatically detects your voice and begins transmitting. To stop transmitting, stop speaking. 3 Transmission will
  • Kenwood TK 3200U2P | Instruction Manual - Page 21
    KEY FUNCTIONS LOCK KEY The default function of the Lock key is Super Lock. Super Lock is designed to prevent accidental function changes on your transceiver, during operation. Press and hold the Lock key for 4 seconds to lock the transceiver keys. The following keys/ functions can still be used when
  • Kenwood TK 3200U2P | Instruction Manual - Page 22
    To start scanning, press the Scan key. • The LED indicator flashes green and scanning starts from the current channel and ascends through the channel numbers. • When a signal is detected on a channel and the QT/ DQT matches, scan pauses at that channel and the LED indicator lights green. • When the
  • Kenwood TK 3200U2P | Instruction Manual - Page 23
    BACKGROUND OPERATIONS TIME-OUT TIMER (TOT) The purpose of the Time-out Timer is to prevent you from using a channel for an extended period of time. This function is useful, for example, when you accidentally keep the PTT switch pressed. Additionally, by limiting the amount of time you can
  • Kenwood TK 3200U2P | Instruction Manual - Page 24
    QUIET TALK (QT)/ DIGITAL QUIET TALK (DQT) Quiet Talk (QT) and Digital Quiet Talk (DQT) are functions that reject signals from undesired parties that are using the same channel as you. You will hear audio from the speaker only when you receive a signal that contains a QT tone or a DQT code that
  • Kenwood TK 3200U2P | Instruction Manual - Page 25
    . Channel Number Table Number Frequency (MHz) Table Number Frequency (MHz) TK-2200 (K) 2-Channel Model TK-3200 (K) 2-Channel Model 1 3 154.5700 2 464.5500 2 4 154.6000 8 467.9250 TK-2200 (K2) 8-Channel Model TK-3200 (K2) 8-Channel Model 1 3 154.5700 2 464.5500 2 4 154.6000
  • Kenwood TK 3200U2P | Instruction Manual - Page 26
    CHANNEL OPERATING FREQUENCIES To change the operating frequency of a channel: With the transceiver power OFF, press and hold the PTT switch and Lock key 1 while turning the transceiver power ON. 1 Continue to hold the PTT switch and Lock key until the LED lights orange and the transceiver
  • Kenwood TK 3200U2P | Instruction Manual - Page 27
    to activate the new settings. Note: The transceiver will automatically return to normal operation if no action is performed for 5 seconds. TK-2200 Operating TK-2200 Operating Table Number Frequency (MHz) Table Number Frequency (MHz) 0 OFF 14 151.7450 1 151.6250 15 151.7750 2 151.9550
  • Kenwood TK 3200U2P | Instruction Manual - Page 28
    -3200 Operating TK-3200 Operating Table Number Frequency (MHz) Table Number Frequency (MHz) 0 OFF 1 464.5000 29 462.9125 2 464.5500 30 464.4875 3 467.7625 31 464.
  • Kenwood TK 3200U2P | Instruction Manual - Page 29
    QUIET TALK (QT)/ DIGITAL QUIET TALK (DQT) SETTINGS To change the QT/ DQT settings of a channel: With the transceiver power OFF, press and hold the PTT switch and Lock key 1 while turning the transceiver power ON. 1 Continue to hold the PTT switch and Lock key until the LED lights orange and
  • Kenwood TK 3200U2P | Instruction Manual - Page 30
    Press the Lock key to increment the Tone number or the Scan key to decrement the number, to select the new tone or code. Tone numbers and their corresponding tones/ codes are provided in the table 5 on pages 23 and 24. Press and hold the Lock or Scan key to increment/ decrement the QT or
  • Kenwood TK 3200U2P | Instruction Manual - Page 31
    QT Channel Settings: QT QT QT QT QT QT Number Frequency Number Frequency Number Frequency 1 67.0 Hz 15 110.9 Hz 29 179.9 Hz 2 71.9 Hz 16 114.8 Hz 30 186.2 Hz 3 74.4 Hz 17 118.8 Hz 31 192.8 Hz 4 77.0 Hz 18 123.0 Hz 32 203.5 Hz 5 79.7 Hz 19 127.3 Hz 33 210.7 Hz 6 82.5 Hz 20 131.8 Hz
  • Kenwood TK 3200U2P | Instruction Manual - Page 32
    DQT Channel Settings: DQT Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 DQT Code D023N D025N D026N D031N D032N D043N D047N D051N D054N D065N D071N D072N D073N D074N D114N D115N D116N D125N D131N D132N D134N D143N D152N D155N D156N D162N D165N D172N DQT Number
  • Kenwood TK 3200U2P | Instruction Manual - Page 33
    KEY ASSIGNMENT MODE This transceiver allows you to reprogram the Lock and Scan keys with any of the functions listed in the table below. Explanations on the use of each function are provided on the following pages. Table Number Function Name 0 None (no function) 1 Calling Alert 2 Key Lock
  • Kenwood TK 3200U2P | Instruction Manual - Page 34
    To change the functions of the Call and Monitor keys: With the transceiver power OFF, press and hold the Lock and Scan keys 1 while turning the transceiver power ON. 1 Continue to hold the Lock and Scan keys until the LED lights orange and the transceiver announces "Setup". Continue to
  • Kenwood TK 3200U2P | Instruction Manual - Page 35
    Press the PTT switch within 5 seconds to save the setting, otherwise the 5 operation will cancel. A beep will sound and the transceiver will announce the new Table number. 6 1 Turn the transceiver power OFF and then ON again to activate the new settings. Note: The transceiver will
  • Kenwood TK 3200U2P | Instruction Manual - Page 36
    CALLING ALERT Calling alert tones are used to identify yourself to your party members and inform them that you are about to make a call. Your dealer can set up your transceiver with 1 of several different calling alert tones. If each party member uses a different calling alert tone, it is easy to
  • Kenwood TK 3200U2P | Instruction Manual - Page 37
    MONITOR/ SQUELCH OFF You can use the key programmed as Monitor or Squelch Off to listen to weak signals that you cannot hear during normal operation, to deactivate channel signaling, and to adjust the volume when no signals are present on your selected channel. • Monitor: Momentarily press to
  • Kenwood TK 3200U2P | Instruction Manual - Page 38
    ■ Temporary Delete You can temporarily remove specific channels from the scanning sequence during Scan. When Scan pauses at a channel, you can remove that channel from the scanning sequence by pressing and holding the key programmed as Temporary Delete for 1 second or Scan + Temporary Delete for 3
  • Kenwood TK 3200U2P | Instruction Manual - Page 39
    ALL RESET MODE At some point in time, you may desire to reset the transceiver settings to their default values. This function will reset all channels to their default frequencies and QT/ DQT, the VOX function to its default status, and all keys to their default functions. To reset the transceiver:
  • Kenwood TK 3200U2P | Instruction Manual - Page 40
    OPTIONAL ACCESSORIES KMC-17 (Speaker/ microphone) KMC-21 (Speaker/ microphone) KHS-1 (Headset) SENS. VOX PTT PTT KHS-22 (Headset) KWR-1 (Water resistant bag) 32
  • Kenwood TK 3200U2P | Instruction Manual - Page 41
    TROUBLESHOOTING GUIDE Problem Cannot turn the transceiver power ON. Battery power dies shortly your transceiver's Scrambler. • Other group members may be too far away. Make sure you are within range of the other transceivers. • Change the QT/ DQT settings. Make sure all group members change the
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

INSTRUCTION MANUAL
' B62-1791-10 (K, K2)
09 08 07 06 05 04 03 02 01
VHF FM TRANSCEIVER
TK-2200
UHF FM TRANSCEIVER
TK-3200