    Hood Combination PRODUCT MODEL NUMBERS KHHC209OS Electrical: A 120-volt, 60-Hz, AC-only, 15- or 20-amp electrical supply located in the upper cabinet as close as possible to the microwave oven hood. A time-delay fuse or circuit breaker and separate circuit is recommended. OVERALL DIMENSIONS
  • 1

PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
VENTING REQUIREMENTS
KHHC209OS
Electrical:
A 120-volt, 60-Hz, AC-only, 15- or
20-amp electrical supply located in the upper
cabinet as close as possible to the microwave
oven hood. A time-delay fuse or circuit breaker
and separate circuit is recommended.
®
Microwave Hood Combination
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only.
For complete details, see Installation
Instructions packed with product.
Specifications subject to change without notice.
Ref. 8206590
04-17-07
Recommended standard fittings
If the existing vent is round, a rectangular-
to-round adapter must be used and a
rectangular 3" extension vent between the
damper assembly and the adapter must be
installed to prevent sticking of the exhaust
damper.
1 - 3-1/4" x 10"
90° elbow
= 25 ft.
1 - wall cap
= 40 ft.
8 feet straight
=
8 ft.
Length of
3-1/4" x 10" system
= 73 ft.
6" vent system
3-1/4" x 10" vent system
1 - transition
=
5 ft.
2 - 90° elbows
= 20 ft.
1 - wall cap
= 40 ft.
8 feet straight
=
8 ft.
Length of 6" system
= 73 ft.
3-1/4" x 10"
90° elbow
90° elbows
transition
wall cap
wall cap
6 ft.
2 ft.
6 ft.
2 ft.
3-1/4" x 10"
to 6" = 5 ft.
3-1/4" x 10"
roof cap = 24 ft.
3-1/4" x 10"
90
°
elbow = 25 ft.
90
°
elbow
6" = 10 ft.
3-1/4" x 10"
wall cap =
40 ft.
3-1/4" x 10"
90
°
flat
elbow= 10 ft.
45
°
elbow
6" = 5 ft.
Recommended vent length
Use 3-1/4" x 10" or 6" vent. The total length of the vent system
including straight vent, elbow, transitions, wall or roof caps
must not exceed the equivalent of 140 feet of
3-1/4" x 10" rectangular or 6" diameter round vent. For best
performance, use no more than three 90° elbows. To calculate
the length of system you need, add the equivalent feet for
each vent piece used in the system. See examples below.
Roof venting
Wall venting
roof cap
3-1/4" x 10"
through-the-roof
3-1/4" x 10"
through-the-wall
wall cap
CABINET OPENING DIMENSIONS
For wall or roof venting methods:
If the wall exhaust method is chosen, be sure that
there is proper clearance within the wall so the vent
fits properly and the damper blade opens fully.
Wall and roof caps must have back-draft damper.
We recommend:
using rigid metal vent.
that length of vent and number of elbows should
be kept to a minimum to provide efficient
performance.
that size of vent should be uniform.
using duct tape to seal all joints in the vent
system.
using caulking compound to seal exterior wall or
roof opening around cap.
two elbows should not be installed together.
We do NOT recommend:
flexible metal vent.
NOTE:
If flexible metal vent must be used, calculate
each foot of flexible metal vent as two feet of rigid
metal vent. Flexible metal elbows count twice as
much as standard elbows.
NOTE:
The grounded 3 prong outlet
must be inside the upper cabinet.
*33" (83.2 cm) is typical for 69"
(175.3 cm) installation height. Exact
dimension may vary depending on
type of range/cooktop below.
A. 2" x 4" wall stud
B. Grounded 3 prong outlet
69" (175.3 cm) min.
12" (30.5 cm) min.
13" (33.0 cm) max.
A
B
33"
(83.2 cm)
typical*
30"
(76.2 cm)
min.
18
¹⁄₄
"
(46.4 cm)
18
¹⁄₄
"
(46.4 cm)
29
⁷⁄₈
" (76.0 cm)
15
¹⁄₂
"
(39.4 cm)