KitchenAid KOSE507EBS Dimension Guide

KitchenAid KOSE507EBS Manual

KitchenAid KOSE507EBS manual content summary:

  • KitchenAid KOSE507EBS | Dimension Guide - Page 1
    30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS KODE300E KODE307E KODE500E KODE507E KODT100E KODT107E KOSE500E KOSE507E KOST100E KOST107E KEBS109E KEBS209E KEBS207E B G Electrical: To properly install your oven for serviceability of the oven. •
  • KitchenAid KOSE507EBS | Dimension Guide - Page 2
    30" (76.2 cm) models A. 30" double ovens. Because Whirlpool Corporation policy includes a continuous commitment to Dimensions are for planning purposes only. For complete details, see improve our products, we reserve the right to change materials and specifications Installation Instructions
  • 1
  • 2

27" (68.6 CM) AND 30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN
PRODUCT MODEL NUMBERS
KODE300E
KODE307E
KODE500E
KODE507E
PRODUCT DIMENSIONS
27" (68.6 cm) models
A. 28¾" (72.8 cm) max. overall
height
B. 257⁄16" (64.6 cm) max. recessed
width
C. 26³⁄4" (67.9 cm) recessed
height
D. 23¹⁄4" (59.1 cm) max. recessed
depth
E. 27" (68.6 cm) overall width
F.
12" (30.5 cm) from back of
control panel to start of strain
relief
G. 48" (121.9 cm) flexible conduit
length
Page 1 of 2
KODT100E
KODT107E
KOSE500E
KOSE507E
KOST100E
KOST107E
KEBS109E
KEBS209E
KEBS207E
Electrical:
To properly install your oven, you must determine the type
of electrical connection you will be using and follow the instructions
provided for it here.
Oven must be connected to the proper electrical voltage and
frequency as specified on the model/serial number rating plate.
The model/serial number rating plate is located under the control
panel on single ovens and under the control panel on the upper
oven cavity on double ovens. See the following illustrations.
art
Single Oven
Double Oven
A. Model/serial number plate
A. Model/serial number plate
Models rated from 7.3 to 9.6 kW at 240 volts (5.4 to 7.4 kW at 208
volts) require a separate 40-amp circuit. Models rated at 4.8 kW
and below at 240 volts (3.6 kW and below at 208 volts) require a
separate 20-amp circuit.
A circuit breaker is recommended.
Connect directly to the circuit breaker box (or fused disconnect)
through flexible, armored or nonmetallic sheathed, copper cable
(with grounding wire). See “Make Electrical Connection” section.
Flexible conduit from the oven should be connected directly to the
junction box.
Fuse both sides of the line.
Do not cut the conduit. The length of conduit provided is for
serviceability of the oven.
A UL listed or CSA approved conduit connector must be provided.
If the house has aluminum wiring, follow the procedure below:
1.
Connect a section of solid copper wire to the ends of the
flexible conduit leads.
2.
Connect the aluminum wiring to the added section of copper
wire using special connectors and/or tools designed and UL
listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with local
codes and industry accepted wiring practices.
For power requirements for models KOST107E, KOST100E,
KOSE507E, KOSE500E, KODE307E, KODE300E, KODE507E,
KODE500E, KODT100E and KODT107E, refer to the following table.
Voltage
Single
Thermal
Single
Convect
Double
Thermal
Double
Convect
Double
Convect/
Thermal
240 VAC
4100 W
4100 W
8163 W
8300 W
8300 W
208 VAC
3100 W
3100 W
6300 W
6300 W
6300 W
240 VAC
17.2 A
17.2 A
34.2 A
34.2 A
34.2 A
208 VAC
15.0 A
15.0 A
29.9 A
29.9 A
29.9 A
30" (76.2 cm) models
A. 28¾" (72.8 cm) max. overall
height
B. 28½" (72.4 cm) max. recessed
width
C. 26³⁄4" (67.9 cm) recessed height
D. 23¹⁄4" (59.1 cm) max. recessed
depth
E. 30" (76.2 cm) overall width
F. 12" (30.5 cm) from back of
control panel to start of strain
relief
G. 48" (121.9 cm) flexible conduit
length
art
27" (68.6 cm) models
A. 51³⁄16" (130.0 cm)
max. overall height
B. 257⁄16" (64.6 cm)
max. recessed width
C. 48¹³⁄16" (124.0 cm)
recessed height
D. 23¹⁄4" (59.1 cm)
max. recessed depth
E. 27" (68.6 cm) overall width
F.
12" (30.5 cm) from back
of control panel to start
of strain relief
G. 66" (167.6 cm) flexible
conduit length
30" (76.2 cm) models
A. 51³⁄16" (130.0 cm)
max. overall height
B. 28½" (72.4 cm)
max. recessed width
C. 48¹³⁄16" (124.0 cm)
recessed height
D. 23¹⁄4" (59.1 cm)
max. recessed depth
E. 30" (76.2 cm) overall width
F.
12" (30.5 cm) from back
of control panel to start
of strain relief
G. 66" (167.6 cm) flexible
conduit length
Ref. W10725670B
05/15
C
B
A
E
D
G
F
B
D
E
A
C
G
F
A
A