  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 1
    INSTALLATION GUIDE FOR THE HOLE PUNCH UNIT GUIDE D'INSTALLATION DE LA PERFORATRICE GUÍA DE INSTALACIÓN PARA LA PERFORADA EINBAUANLEITUNG FÜR LOCHEREINHEIT GUIDA ALL'INSTALLAZIONE DELL'UNITÀ DI PERFORAZIONE PH-5A/PH-5B/PH-5C/PH-5D
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 2
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 3
    çais Pièces fournies A Perforatrice 1 B Carte de perforation 1 C Cordon d'alimentation 1 D Bac de récupération de la perforatrice .... 1 E Guide 1 Español Partes suministradas A Perforadora 1 B PCB de perforación 1 C Cable de alimentación 1 D Caja para desechos de la perforación ..... 1 E Gu
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 4
    6 5 7 2 5 3 1 4 1 Installation Procedure Before installing the hole punch unit, make sure the MFP's main power switch is turned off and that its power cord is unplugged from the power outlet. Install the document finisher first and then install the hole punch unit. Removing the cover 1.
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 5
    5. Engage the projection and the pawl of the guide (E) with the hole punch unit (A) to install the guide. Installation du guide 5. Engager la projection et le cliquet du guide (E) dans la perforatrice (A) pour installer le guide. Instalación de la guía 5. Acople el resalto y el trinquete de la gu
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 6
    document finisher. Installing the waste hole punch box 9. Open the front cover of the document finisher and insert the waste hole punch box (D) along the guide (E) which was installed in step 5. 10. Clean the upper right cover of the waste hole punch box (D) with alcohol and adhere the label (H) on
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 7
    a 14/15 b 13/16 c 17/18 13 12 C B d 19/20 21/22 23/24 e 25/26 14. Open the wire saddle (12) and put the 2P-connector (13) on the motor through the wire saddle to fix the punch PCB (B). 15. Connect the power cord (C) to the punch PCB (B). Figure (a): 6P-connector (14) of power coed (C) and 6P-
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 8
    7 27 6 5 7 5 3 28 7 27 4 28 7 Installing the cover 16. Engage the pawl (27) of the document finisher with the concave section (28) at the back of the top cover (7) which was removed in step 3. After that, reinstall the top cover (7) by pressing the finisher releasing lever (6) with four
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 9
    2 X X' 1 1 -2mm X X' +2mm 18. Use four screws (1) to reinstall the back cover (2) which was removed from the document finisher in step 1. [Checking the center of the punch hole] 1. Plug the MFP into a power outlet, and turn on its main power switch. 2. In the punch mode, perform a test copy with
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 10
    4 3 5 3 1 2 G G A a b Centering punch-holes 1. Open the upper cover (1) and the tray C (2) of the document finisher. 2. Remove four screws (3) and hold pressing the finisher releasing lever (4) to remove the top cover (5). Centrage des perforations 1. Ouvrir le capot supérieur (1) et le bac
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 11
    X X' -2mm X X' +2mm 7. Repeat steps 1 to 6 until the vertical gap of the punch holes on the copy sample are within the reference value. 8. After adjustment, tighten two M4 × 10 tap Tight S screws (G) loosened in step 3. 9. Use four screws (3) to reinstall the top cover (5) which was removed in step
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 12
    a: 9.5 2 mm a: 5.5 2 mm [Checking distance from leading edge to the punch holes] 1. In the punch mode, perform a test copy with paper fed from the MP tray. 2. Check the distance from the paper leading edge to the punch holes (a). If the distance is out of the reference range, follow the steps
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 13
    a: 9.5 2 mm a: 5.5 2 mm 3. Perform a test copy. 4. Repeat steps 1 to 3 until the distance from the leading edge to the punch hole indicates the value within the reference range. Distance (a) in metric specification: 9.5 ±2 mm Distance (a) in inch specification: 5.5 ±2 mm 3.
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 14
    [Swedish specification] 1. When using the hole punch unit of Swedish specification, enter the maintenance mode U234 and select SWEDEN METRIC. [Spécifications suédoises] 1. Lors de l'utilisation de la perforatrice avec les spécifications suédoises, entrer le mode d'entretien U234 et sélectionner
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 15
    English NOTICE This accessory is for use only with the following Applicant's Listed Machine. Mode:l DF-710 Français AVIS Cet accessoire est utilisable uniquement avec le copieur figurant dans la liste du demandeur suivant. Modèle: DF-710 Español AVISO Este accesorio es sólo para usar en las
  • Kyocera KM-C3232 | PH-5A Installation Guide - Page 16
    2006. 2 303KA56710 Rev.1.0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

INSTALLATION GUIDE FOR THE HOLE PUNCH UNIT
GUIDE D’INSTALLATION DE LA PERFORATRICE
GUÍA DE INSTALACIÓN PARA LA PERFORADA
EINBAUANLEITUNG FÜR LOCHEREINHEIT
GUIDA ALL’INSTALLAZIONE DELL’UNITÀ DI PERFORAZIONE
パンチユニット設置手順書
PH-5A/PH-5B/PH-5C/PH-5D