LG DLG3788W Owners Manual - Page 15

wire connection : Direct wire

Page 15 highlights

4. Put the hooked shape ends of the wire under the screw of the terminal block(hooked end facing rightward) and squeeze the hook together and screw tightly. 5. Put the hooked shaped ends of the other power supply cable wires under the outer terminal block screws(hooked end facing right) and squeeze the hooked ends together and screw tightly. 6. Tighten strain relief screws. 7. Place the tab of terminal block cover into slot of dryer rear panel. Make sure cover with screw. 3-wire connection : Direct wire Important : The places wherea 4-wire connection is needed are mobile homes and areas that local codes do not admit the use of 3-wire connections. At least, 5ft(1.52m) of extra length is required for dryer to be able to move. Peel 5 in (12.7cm) of external covering from end of cable, leaving bare ground wire at 5 in (12.7cm). Cut 11/2 in. (3.8cm) from 3 remaining wires. Strip insulation back lin. (2.5cm). Shape ends of wires into a hook shape. Then, put the hooked shape end of the wire under the screw of the terminal block(hooked end facing rightward) and pinch the hook together and screw tightly. 1. Take off center terminal block screw 2. Put the hooked end of the neutral wire(white) of power supply cable under the center screw of terminal block). Squeeze the hooked end together 3. Connect the hooked ends of the other power supply cable to the center screw of terminal block. 4. Screw strain relief tightly. 5. Place tab of terminal block cover into slot of dryer rear panel. Make sure cover with screw. a. External ground connector b. Neutral grounding wire (white) c. Center silver-colored terminal block screw d. Neutral wire (white or center wire) e. 3/4in. (!.9cm) UL-listed strain relief IS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

4. Put the
hooked
shape
ends
of the
wire
under
the
screw
of the terminal
block(hooked
end
facing
rightward)
and squeeze
the
hook
together
and
screw
tightly.
5. Put the
hooked
shaped
ends
of the other
power
supply
cable
wires
under
the outer
terminal
block
screws(hooked
end facing
right)
and
squeeze
the
hooked
ends
together
and
screw
tightly.
6. Tighten
strain
relief
screws.
7. Place
the
tab of terminal
block
cover
into
slot of
dryer
rear
panel.
Make
sure
cover
with
screw.
3-wire connection : Direct wire
Important
: The
places
wherea
4-wire
connection
is
needed
are mobile
homes
and
areas
that local
codes
do not admit
the
use of 3-wire
connections.
At least,
5ft(1.52m)
of extra
length
is required
for
dryer
to be able
to move.
Peel
5 in (12.7cm)
of external
covering
from
end
of cable,
leaving
bare
ground
wire
at 5 in (12.7cm).
Cut
11/2 in. (3.8cm)
from
3 remaining
wires.
Strip
insulation
back
lin.
(2.5cm).
Shape
ends
of wires
into
a hook
shape.
Then,
put the hooked
shape
end
of the wire
under
the
screw
of the terminal
block(hooked
end
facing
rightward)
and
pinch
the hook
together
and
screw
tightly.
1. Take
off center
terminal
block
screw
2. Put the
hooked
end of the
neutral
wire(white)
of
power
supply
cable
under
the center
screw
of
terminal
block).
Squeeze
the
hooked
end together
3. Connect
the hooked
ends
of the other
power
supply
cable
to the center
screw
of terminal
block.
4. Screw
strain
relief
tightly.
5. Place
tab of terminal
block
cover
into
slot of
dryer
rear
panel.
Make
sure
cover
with
screw.
a.
External
ground
connector
b.
Neutral grounding
wire (white)
c.
Center silver-colored
terminal
block screw
d.
Neutral
wire (white or center
wire)
e.
3/4in.
(!.9cm)
UL-listed
strain relief
IS