LG L1204R Owners Manual

LG L1204R Manual

LG L1204R manual content summary:

  • LG L1204R | Owners Manual - Page 1
    website http://www.lgservice.com ENGLISH ESPAÑOL LG LG Window-Type Air Conditioner OWNER'S MANUAL MODELS, MODELOS: WK Series: LW7000ER LW8000ER WL Series: L1004R LW1000ER L1204R LW1200ER L1404R LB1000ER LB1200ER WP Series: LW1400ER L1504R LW1500ER L1804R LW1800ER IMPORTANT Please read through
  • LG L1204R | Owners Manual - Page 2
    Window-Type Air Conditioner Owner's Manual TABLE OF CONTENTS 1. Safety Precautions 2. Operating Instructions 3. Care and Maintenance 4. Hardware Installation 5. Common Issues FOR YOUR RECORDS Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each
  • LG L1204R | Owners Manual - Page 3
    or damage to properties only. s Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. s Installation WARNING Always install the expansion panel(s). • No installation may cause fire and electric shock accident. Do not place the power
  • LG L1204R | Owners Manual - Page 4
    appliances. grounded outlet. • It will cause electric shock or fire due to heat generation. • No grounding may cause electric shock (See Installation Manual). Unplug the unit if strange sounds, odors, or smoke come from it. • Otherwise it may cause fire and electric shock accident. Do not use
  • LG L1204R | Owners Manual - Page 5
    operating air conditioner when gas goes out. • It will cause failure of machine • It is not designed to cool the • It may cause explosion, fire, or electric shock. entire house. and burn. ENGLISH s Installation CAUTION Never touch the metal parts of the unit when removing the filter. Do
  • LG L1204R | Owners Manual - Page 6
    or electric shock. If water enters the product, turn off the the power switch of the main body of appliance. Contact service center after taking the power-plug out from the socket. Do not clean the air conditioner with water. • Water may enter the unit and degrade the insulation. It may cause
  • LG L1204R | Owners Manual - Page 7
    Prior to Operation Preparing for operation 1 Contact an installation specialist for installation. 2 Plug in the power plug properly. 3 Do metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. 2 Do not use water to clean inside the air conditioner.
  • LG L1204R | Owners Manual - Page 8
    Instructions Remote Control Operations The remote control and control panel will look like those represented in the following pictures. 6 COOL FAN DRY FAN INDOOR DESIRED ENERGY SAVER AIR PURIFIER CLEAN FILTER AIR PURIFIER Air Purifier Power 7 1 Temp 2 Fan Speed TIMER FAN SPEED MODE
  • LG L1204R | Owners Manual - Page 9
    dry mode for dry operation. 4 FAN SPEED SELECTOR For increased power while cooling, select a higher fan speed. 3 steps: High ➔ Low ➔ Med 5 ON/OFF TIMER The timer can be set to start and stop the unit in hourly increments (up to 12 hours). 6 REMOTE CONTROL SENSOR 7 AIR PURIFIER • Press the Air
  • LG L1204R | Owners Manual - Page 10
    Before using the ventilation feature, position the vent lever by pulling Part A out straight and snapping it into place. Adjusting the Air Flow Direction Part A Airflow can be adjusted by changing the direction of the air conditioner's louvers. This can also increase the cooling efficiency of the
  • LG L1204R | Owners Manual - Page 11
    ) to maintain optimal performance of the air conditioner. How to remove the air filter 1 The grille may be opened from the top for easy maintenance after installation. 2 Open the inlet grille by pulling off the exposed door on the top of the unit (based on installation). 3 Pull the tab slightly to
  • LG L1204R | Owners Manual - Page 12
    in water mixed with a mild detergent for 20~30 minutes. 3 Dry the Air Purifying Filter in the shade for a day.(The moisture must be removed completely on this part.) 4 Note the cuts of electric discharge lines. 5 Re-install the Air Purifying Filter to the original position. WARNING: Don't touch this
  • LG L1204R | Owners Manual - Page 13
    Installation Hardware Installation Product Features CAUTION: This appliance should be installed in accordance with national wiring regulations. The following information serves acts as a guide to help to explain product features. 13 6 5 8 1 2 4 3 1. CABINET 2. FRONT GRILLE 3. AIR FILTER 4. AIR
  • LG L1204R | Owners Manual - Page 14
    greatly reduce the cooling efficiency of the air conditioner. Awning Fence Heat radiation About 1/2" Over 20" CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure. 4 Install the unit a little slanted so the back is slightly lower than the front (about
  • LG L1204R | Owners Manual - Page 15
    greatly reduce the cooling efficiency of the air conditioner. Awning Fence Heat radiation About 1/2" Over 20" CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure. 4 Install the unit a little slanted so the back is slightly lower than the front (about
  • LG L1204R | Owners Manual - Page 16
    greatly reduce the cooling efficiency of the air conditioner. Awning Fence Heat radiation About 1/2" Over 20" CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure. 4 Install the unit a little slanted so the back is slightly lower than the front (about
  • LG L1204R | Owners Manual - Page 17
    12 9 11 NO. NAME OF PARTS Q'TY 1 FRAME CURTAIN 2 2 SILL SUPPORT 2 3 BOLT 2 4 NUT 2 5 SCREW (TYPE A) 16 6 SCREW (TYPE B) 3 7 SCREW (TYPE C) 5 8 FOAM-STRIP 1 9 DRAIN PIPE 1 10 FOAM-PE 1 11 FRAME GUIDE 2 12 WINDOW LOCKING BRACKET 1 13 FOAM-PE 1 Suggested Tool
  • LG L1204R | Owners Manual - Page 18
    Upper Guide until it meets. Window Sash NOTICE : Do not pull the window sash down tightly that the movement of Frame Curtain is restricted. Foam-pe 13 Window stool Front Angle Fig. 1 Upper guide Cabinet Frame Curtain 1 Foam-pe 10 Fig. 2 3 Loosely assemble the Sill Support using the parts in
  • LG L1204R | Owners Manual - Page 19
    sash track, and repeat step 2. Sill Support 2 Sash track Sill Support 2 9 Attach each Frame Curtain the window sash using screws (Type C). (See Fig. 6) Front Angle Screw(Type B) 6 Fig. 5 CAUTION: Do not drill a hole in the bottom pan. The unit is designed to operate with approximately 1/2" of
  • LG L1204R | Owners Manual - Page 20
    Fig. 10) 14 Pull down the inlet grille and secure it with a Type A screw through the front grille. (See Fig. 11) 15 Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet. Window locking bracket 12 Fig. 9 Fig. 10 Fig. 11 20
  • LG L1204R | Owners Manual - Page 21
    . NAME OF PARTS 1 FRAME CURTAIN 2 SUPPORT BRACKET 3 SILL BRACKET 4 LOCK NUT 5 SCREW (TYPE A) 6 SCREW (TYPE B) 7 SCREW (TYPE C) 8 SCREW (TYPE D) 9 CARRIAGE BOLT 10 FOAM STRIP 11 FOAM SEAL 12 WINDOW LOCKING BRACKET 13 DRAIN PIPE 14 FOAM-PE 15 FRAME GUIDE Q'TY 2 2 2 4 14
  • LG L1204R | Owners Manual - Page 22
    Cabinet Installation 1 Open the window. Mark a line on the center of the window stool between the side window stop moldings. Loosely attach the sill bracket to the support bracket using the carriage bolt and the lock nut. Sill Bracket 3 Carriage Bolt 9 Support Bracket 2 Lock nut 4 Fig. 12 2
  • LG L1204R | Owners Manual - Page 23
    screws(Type A) at cabinet's sides. Screw Power Cord 8 Cut the Foam-strip to the proper length and insert between the upper window sash and the lower window sash.(See Fig. 19) 9 Attach the Window locking bracket with a screw (Type C.) (See Fig. 20) COOL FAN DRY INDOOR FAN HEAT DEFROST DESIRED
  • LG L1204R | Owners Manual - Page 24
    ) TEMP TIME SPFAENED MODE POWER 12 Window installation of room air conditioner is now completed. See Standard 125V, 3-wire grounding receptacle rated 15A, 125V AC Use 15 AMP, time delay (grounding) extension cord, rated at 15A, 125V. Electrical Data (L1804R, LW1800ER MODELS) Line Cord Plug Use
  • LG L1204R | Owners Manual - Page 25
    ENGLISH Electrical Safety IMPORTANT (PLEASE READ CAREFULLY) FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated at 15A, 125V. Fig. 23 25
  • LG L1204R | Owners Manual - Page 26
    one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and ordinances. PREFERRED METHOD 3-prong grounding plug 3-prong grounding type wall receptacle NOTICE : DO NOT USE AN EXTENSION CORD on 230, 208, and 230/208 Volt units. Power supply
  • LG L1204R | Owners Manual - Page 27
    from overloading Air conditioner does not cool s Air flow is restricted s The THERMOSTAT may not be set cool enough s The air filter is dirty. s The air conditioner was just turned on. s Cold air is escaping. s Cooling coils are iced up • Make sure there are no curtains, blinds, furniture
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

LG
Window-Type Air Conditioner
OWNER'S MANUAL
LG
MODELS, MODELOS:
WK Series: LW7000ER
LW8000ER
WL Series:
L1004R
LW1000ER
L1204R
LW1200ER
L1404R
LB1000ER
LB1200ER
WP Series:
LW1400ER
L1504R
LW1500ER
L1804R
LW1800ER
ESPAÑOL
ENGLISH
IMPORTANT
Please read through this manual. It contains valuable
information about your air conditioner. This manual may
help save time and money by explaining proper air
conditioner maintenance and preventing improper use.
PRECAUTIONS
Pay close attention to precautions in order to prevent
potential hazards and damage from misuse or improper
installation. LG is not responsible for any damages
caused by misuse of the air conditioner.