LG LP155HED1 Owner's Manual - Page 9

Electrical Safety

Page 9 highlights

Electrical Safety ENGLISH Electrical Safety Electrical Data 115V~ 230V~ 265V~ Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. NOTICE The shape may be different according to its model. Use Wall Receptacle Power Supply Standard 208/230V, 3-wire grounding receptacle rated 15A Standard 208/230V, 3-wire grounding receptacle rated 20A Use 15 AMP. time delay fuse or 15 AMP. Circuit breaker. Use 20 AMP. time delay fuse or 20 AMP. Circuit breaker. (2500W Heater 15 AMP Circuit Breaker) Never push the test button during operation Otherwise this plug can damaged. This device contains chemicals, including lead, known to the State of California to cause cancer, birth defects, or other reproductive harm. Wash hands after handling. Do not remove, modify, or immerse this plug. If this device trips, the cause should be corrected before further use. Standard 208/230V, 3-wire grounding receptacle rated 30A Standard 265V grounding receptacle rated 20A Use 30 AMP. time delay fuse or 30 AMP. Circuit breaker. Use 20 AMP,time delay fuse or 20 AMP Circuit breaker (2000W Heater 15 AMP Circuit Breaker) Standard 265V grounding receptacle rated 30A Use 30 AMP,time delay fuse or 30 AMP Circuit breaker NOTICE DO NOT USE AN EXTENSION CORD on 230, 208, and 230/208,265Volt units. All wiring should be made in accordance with local electrical codes and regulations. Aluminum house wiring may pose special problems. Consult a qualified electrician. The conductors inside this cord are surrounded by shields, which monitor leakage current. These shields are not grounded. Periodically examine the cord for any damage. Do not use this product in the event the shields become exposed. Avoid shock hazard! This unit cannot be serviced. Opening the tamper-resistant, sealed portion of the unit voids all warranties and performance claims. This unit is not intended to be an ON/OFF switch. • If unit equipped with cords and plugs as long as they are installed with sub-bases, and the cord and plug are enclosed within the sub-base. • The sub-base must have means for permanent connection. • The sub-base must have an outlet for the connection of the cord and plug. • To complete the installation of this PTAC, there must be a sub-base. Owner's Manual 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

Electrical Safety
Owner’s Manual
9
ENGLISH
Electrical Safety
Electrical Data
115V~
230V~
265V~
Power cord may include a current
interrupter device. A test and reset
button is provided on the plug case. The
device should be tested on a periodic
basis by first pressing the TEST button
and then the RESET button. If the TEST
button does not trip or if the RESET
button will not stay engaged,
discontinue use of the air conditioner
and contact a qualified service
technician.
Use Wall Receptacle
Power Supply
Standard 208/230V, 3-wire
grounding receptacle rated 15A
Standard 208/230V, 3-wire
grounding receptacle rated 20A
Use 15 AMP. time
delay fuse or 15 AMP.
Circuit breaker.
Use 20 AMP. time
delay fuse or 20 AMP.
Circuit breaker.
(2500W Heater
15 AMP
Circuit Breaker)
(2000W Heater
15 AMP
Circuit Breaker)
Use 30 AMP. time
delay fuse or 30 AMP.
Circuit breaker.
Standard 208/230V, 3-wire
grounding receptacle rated 30A
Use 20 AMP,time delay
fuse or 20 AMP
Circuit breaker
Standard 265V grounding
receptacle rated 20A
Use 30 AMP,time delay
fuse or 30 AMP
Circuit breaker
Standard 265V grounding
receptacle rated 30A
Never push the test button during operation
Otherwise this plug can damaged.
This device contains chemicals, including lead, known
to the State of California to cause cancer, birth
defects, or other reproductive harm.
Wash hands after handling.
Do not remove, modify, or immerse this plug.
If this device trips, the cause should be corrected
before further use.
The conductors inside this cord are surrounded by
shields, which monitor leakage current.
These shields are not grounded.
Periodically examine the cord for any damage. Do
not use this product in the event the shields become
exposed.
Avoid shock hazard! This unit cannot be serviced.
Opening the tamper-resistant, sealed portion of the
unit voids all warranties and performance claims.
This unit is not intended to be an ON/OFF switch.
• If unit equipped with cords and plugs
as long as
they are installed with sub-bases, and the cord and
plug are enclosed within the sub-base.
• The sub-base must have means for permanent
connection.
• The sub-base must have an outlet for the connection
of the cord and plug.
• To complete the installation of this PTAC, there must
be a sub-base.
The shape may be different according to its model.
NOTICE
DO NOT USE AN EXTENSION CORD on 230, 208,
and 230/208,265Volt units.
All wiring should be made in accordance with local
electrical codes and regulations.
Aluminum house wiring may pose special problems.
Consult a qualified electrician.
NOTICE