LG LT1030C Owners Manual

LG LT1030C Manual

LG LT1030C manual content summary:

  • LG LT1030C | Owners Manual - Page 1
    ESPAÑOL website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html ROOM AIR CONDITIONER OWNER'S MANUAL Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner. ACONDICIONADOR DE AIRE DE
  • LG LT1030C | Owners Manual - Page 2
    8 Symbols Used in this Manual ........8 Electrical Safety 8 Temporary Use of an Adapter 10 Temporary Use of an Extension Cord 10 Operating Instructions 11 Care and Mainenance 14 Installation 15 Maintenance and Service 22 Normal Operation 22 Troubleshooting 22 FOR YOUR RECORDS Write
  • LG LT1030C | Owners Manual - Page 3
    indicates the possibility of injury or damage to properties only. s Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. s Installation Always install the trim frame(s). WARNING Do not place the power cord near a heater. • Improper
  • LG LT1030C | Owners Manual - Page 4
    It will cause electric shock or fire. Use the air conditioner on a single outlet circuit. (See page 7.) Do not share the outlet with other appliances. Always plug into a grounded outlet. • It will cause electric shock or • No grounding may cause fire. electric shock. Unplug the unit if strange
  • LG LT1030C | Owners Manual - Page 5
    product, turn off the the power switch of the main body of appliance. Contact service center after taking the powerplug out from the socket. • It They are sharp and may cause injury. • It may cause failure of appliance or performance deteriorate. Ensure that the outer case is not damaged by age
  • LG LT1030C | Owners Manual - Page 6
    or speed during operation, it may plant. cause injury. Do not use this appliance for special purposes such as pets, foods, precision machinery, or objects of art. • It is an air conditioner, not a precision refrigeration system. PTAC DIRECT SALES (877) 454-7822 Always insert the filter securely
  • LG LT1030C | Owners Manual - Page 7
    damaged and requires replacement, have an Authorized Servicer install an exact replacement part. Usage 1. The air conditioner is a consumer comfort appliance, not a precision climate control system. of the unit. Service For repair and maintenance, contact an Authorized Service Center. See the
  • LG LT1030C | Owners Manual - Page 8
    Introduction Introduction Symbols Used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner. Tips
  • LG LT1030C | Owners Manual - Page 9
    454-7822 Electrical Safety WARNING: This appliance must be properly grounded. The power cord of this appliance is equipped with a three-prong grounding ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall
  • LG LT1030C | Owners Manual - Page 10
    the power cord as this can lead to eventual ground terminal damage. Temporary method Adapter Plug Metal Screw Receptacle Cover WARNING: Never use the appliance with a broken adapter. Temporary Use of an Extension Cord We strongly discourage the use of an extension cord due to potential safety
  • LG LT1030C | Owners Manual - Page 11
    ENGLISH Operating Instructions Operating Instructions The controls will look like one of the following: Controls - Cooling Only Operation Off Med High Fan Cool Off - Turns can access the Energy Saver switch when you open the inlet grille. PTAC DIRECT SALES (877) 454-7822 Owner's Manual 11
  • LG LT1030C | Owners Manual - Page 12
    Operating Instructions The controls will look like one of the following: Controls - Cooling & Heating Operation O Off ( o ) :Turns the air conditioner off. Fan ( ) : The low fan speed operation
  • LG LT1030C | Owners Manual - Page 13
    ventilation lever to the OPEN position. The damper is opened and room air is exhausted outside. Operating Instructions PULL OPEN / PUSH CLOSE Air Direction The direction of air can be controlled wherever you want by moving the horizontal louver. PTAC DIRECT SALES (877) 454-7822 Owner's Manual 13
  • LG LT1030C | Owners Manual - Page 14
    . If the filter becomes turn or damaged you should replace immediately. Replacement filters are available from your salesperson, dealer, and the authorized customer service centers. 1. Open the inlet grille downward by pulling out the top of the inlet grille. 2. Remove the air filter from the front
  • LG LT1030C | Owners Manual - Page 15
    SUPPORT BLOCK 2 BAFFLE 1 TRIM FRAME 2 SHIM 2 PLASTIC NUTS AND WASHER SCREWS 4 25-7/8" (656 mm) Expanded aluminum metal grille LGE Wall Sleeve 15-17/32" (394 mm) 16-23/32" (425 mm) FIG. 2 ELECTRICAL SERVICE Check your available electrical service covered in this manual pose an excessive
  • LG LT1030C | Owners Manual - Page 16
    the unit will lessen the chance that service will be needed. ITEMS IN INSTALLATION HARDWARE Insulation Strips 13/8 x 3/4 x 611/2 1 13/8 x 13/8 x 611/2 1 Support Block 13/4 x 13/8 x 45/16 2 Baffle 14 x 41/2 x 1/8 1 16-3/4 Tips All wall sleeves used to mount the new Air Conditioner must be
  • LG LT1030C | Owners Manual - Page 17
    the Around Insulation strip 13/8 x 3/4 x 611/2 and attach that to the inside front of the sleeve as shown below. Around Insulation Horizontal Insulation FIG. 7 CAUTION • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the
  • LG LT1030C | Owners Manual - Page 18
    attach them to the inside of the wall sleeve as shown FIG 9. Slide the baffle into slots of the support blocks. Wall Wall Sleeve Baffle (7 5/16") or Fasten the screws FIG. 10 Front Support Block FIG. 13 7 Install the new unit into the wall sleeve. PTAC DIRECT SALES (877) 454-7822 18 Room
  • LG LT1030C | Owners Manual - Page 19
    piece as shown below. Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below. Trim (2 ea) Wall FIG. 14 CAUTION • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To
  • LG LT1030C | Owners Manual - Page 20
    holes of the rear flanges. Around Insulation Horizontal Insulation FIG. 18 5 If the depth of your existing sleeve is less than or equal to 18", skip to step 7. Otherwise, cut the baffles and the support blocks according to Length "A" in the table below. Depth"D" of the existing Length "A" wall
  • LG LT1030C | Owners Manual - Page 21
    as shown below. 1" high 3/4" High FIG. 21 Shim (2EA) 6" 6" FIG. 22 8 Install the new unit into the wall sleeve Trim (2 ea) Wall FIG. 23 CAUTION • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent
  • LG LT1030C | Owners Manual - Page 22
    Instructions Maintenance and Service Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service the compressor does not. PTAC DIRECT SALES (877) 454-7822 Troubleshooting Problem Air conditioner does not start Air conditioner does not cool as it
  • LG LT1030C | Owners Manual - Page 23
    Memo Owner's Manual 23 ENGLISH PTAC DIRECT SALES (877) 454-7822
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

e-mail
ROOM AIR CONDITIONER
OWNER'S MANUAL
Please read the operating instructions and safety precautions carefully
and thoroughly before installing and operating your room air conditioner.
Por favor lea las instrucciones de operación y las precauciones de
seguridad cuidadosa y totalmente antes de instalar y operar su
acondicionador de aire de ventana.
MODELS, MODELOS:
LT0810C
LT1010C
LT1030C, LT1030H
LT1210C
LT1230C, LT1230H
ACONDICIONADOR DE AIRE DE VENTANA
MANUAL DEL PROPIETARIO
ENGLISH
ESPAÑOL
PTAC DIRECT SALES (877) 454-7822