Lenovo ThinkServer RD330 MegaRAID SAS Software User Guide - Page 207

Locate the Drives and, Activate LED, Mark the Con d Drive as, Missing, 15.10, Display

Page 207 highlights

MegaRAID SAS Software User Guide Chapter 5: MegaRAID Command Tool | Drive-Related Options 5.15.8 Locate the Drive(s) and Activate LED Use the command in the following table to locate the drive(s) for the selected controller(s) and activate the drive activity LED. Table 93: Locate Drive and Activate LED Convention Description MegaCli -PDLocate -PhysDrv[E0:S0,E1:S1....] -aN|-a0,1,2|-aALL Locates the drive(s) for the selected controller(s) and activates the drive activity LED. -Physdrv[E0:S0,...]: Specifies the physical drive enclosure and the slots for the drives. 5.15.9 Mark the Configured Drive as Missing Use the command in the following table to mark the configured drive as missing for the selected controller(s). Table 94: Mark Configured Drive as Missing Convention Description MegaCli -PDMarkMissing -PhysDrv[E0:S0,E1:S1....] -aN|-a0,1,2|-aALL Marks the offline drive as missing for the selected controller(s). -Physdrv[E0:S0,...]: Specifies the physical drive enclosure and the slots for the drives. 5.15.10 Display the Drives in Missing Status NOTE: PdMarkMissing works only on offline drives. If you want to make a configured drive as missing, first mark it as offline, then mark it as missing. When PdReplaceMissing is run, the drive becomes offline, and Rebuild does not start automatocally. One has to start it explicitly. Follow these steps to replace the PD or retrieve the PD: 1. pdgetmissing (This command reports the array and the row number needed for the next command). 2. pdreplacemissing (Input the array and row number here). 3. pdonline. Use the command in the following table to mark the configured drive as missing for the selected controller(s). Table 95: Display Drives in Missing Status Convention Description MegaCli -PDGetMissing -aN|-a0,1,2|-aALL Displays the drive(s) in missing status. The format is: No Row Column SizeExpected(MB) 0 x y zzzzzzzzz ... Where x is the index to the drive groups, y is the index to the drive in that drive group, and zzzzzz is the minimum capacity of the drive that can be used as a replacement. Page 207

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352
  • 353
  • 354
  • 355
  • 356
  • 357
  • 358
  • 359
  • 360
  • 361
  • 362
  • 363
  • 364
  • 365
  • 366
  • 367
  • 368
  • 369
  • 370
  • 371
  • 372
  • 373
  • 374
  • 375
  • 376
  • 377
  • 378
  • 379
  • 380
  • 381
  • 382
  • 383
  • 384
  • 385
  • 386
  • 387
  • 388
  • 389
  • 390
  • 391
  • 392
  • 393
  • 394
  • 395
  • 396
  • 397
  • 398
  • 399
  • 400
  • 401

Page 207
MegaRAID SAS Software User Guide
Chapter 5: MegaRAID Command Tool
|
Drive-Related Options
5.15.8
Locate the Drive(s) and
Activate LED
Use the command in the following table to locate the drive(s) for the selected
controller(s) and activate the drive activity LED.
5.15.9
Mark the Configured Drive as
Missing
Use the command in the following table to mark the configured drive as missing for the
selected controller(s).
NOTE:
PdMarkMissing works only on offline drives. If you want to make a configured
drive as missing, first mark it as offline, then mark it as missing. When PdReplaceMissing
is run, the drive becomes offline, and Rebuild does not start automatocally. One has to
start it explicitly.
Follow these steps to replace the PD or retrieve the PD:
1.
pdgetmissing
(This command reports the array and the row number needed for
the next command).
2.
pdreplacemissing
(Input the array and row number here).
3.
pdonline.
5.15.10
Display the Drives in Missing
Status
Use the command in the following table to mark the configured drive as missing for the
selected controller(s).
Table 93:
Locate Drive and Activate LED
Convention
MegaCli –PDLocate –PhysDrv[E0:S0,E1:S1
....
]
-aN|-a0,1,2|-aALL
Description
Locates the drive(s) for the selected controller(s) and activates the drive
activity LED.
-Physdrv[E0:S0,...]
: Specifies the physical drive enclosure and the
slots for the drives.
Table 94:
Mark Configured Drive as Missing
Convention
MegaCli –PDMarkMissing –PhysDrv[E0:S0,E1:S1
....
]
-aN|-a0,1,2|-aALL
Description
Marks the offline drive as missing for the selected controller(s).
-Physdrv[E0:S0,...]
: Specifies the physical drive enclosure and the
slots for the drives.
Table 95:
Display Drives in Missing Status
Convention
MegaCli –PDGetMissing -aN|-a0,1,2|-aALL
Description
Displays the drive(s) in missing status. The format is:
No
Row
Column SizeExpected(MB)
0
x
y
zzzzzzzzz
Where
x
is the index to the drive groups,
y
is the index to the drive in that
drive group, and
zzzzzz
is the minimum capacity of the drive that can be
used as a replacement.