Page 45 highlights
4513-420, -430 Error Description Action 959.03 959.04 Signature Verification Code failed to authenticate a code partition. Jump to unverified address Update firmware and call the next level of support, or replace the controller board. See "Controller board service check" on page 2-22. 959.05 Unknown boot failure Update firmware and call the next level of support, or replace the controller board. See "Controller board service check" on page 2-22 959.20 959.21 Pensive hardware failure Pensive did not respond to command request. Replace the controller board. See "Controller board service check" on page 2-22. 959.22 Challenge secret failure 959.23 959.24 Pensive self test failed during initialization. EEPROM retention error Replace the controller board. See "Controller board service check" on page 2-22. 959.25 Insufficient device space during HW prog 959.26 Incremental counter reset exceeds maximum value 959.27 Increment count failed due to max value limit 959.28 Invalid SP memory configuration Memory and emulation errors 960.xx RAM memory error: RAM soldered on the controller board is bad Replace the controller board. See "Controller board service check" on page 2-22. 961.xx RAM memory error: memory card in slot is bad. Replace the memory card. 964.xx Download Emulation Cyclic Redundancy Check Error: checksum failure detected in the emulation header or emulation file. Disable the Download Emulation. Program the download emulation into the firmware card again. If this does not resolve the problem, then replace the firmware card and download the emulation again. Network errors 975.xx Unrecognizable network Call the next level of support. 976.xx Unrecoverable software error in network port 978.xx Bad checksum while programming network port 979.xx Flash parts failed while programing network port Other errors 980.xx Engine experiencing unreliable communication with the Call the next level of support. specified device 981.xx Engine protocol violation detected by the specified device 982.xx Communications error detected by the specified device 983.xx Invalid command received by the specified device Diagnostics information 2-19