Lexmark E360d Service Manual - Page 52
Main motor service check
View all Lexmark E360d manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
4513-420, -430 Main motor service check FRU Main motor gear drive Main motor cable LVPS/HVPS Controller board Warning: Do not replace the operator panel and controller board at the same time. Each card contains the printer settings. When either of these cards is new, it obtains the settings from the other card. Settings are lost when both are new and replaced at the same time. Action Turn off the printer, and unplug the main motor cable at J17. Turn on the printer, and check for the following voltages at J17: J17 pins Voltages Pins 1-4, 6 Approx. 5 V dc Pins 7-9 18 V dc-24 V dc Verify ground at pin 5 for both the card and cable. • If these voltages are correct, then check the main motor cable for continuity. - Remove the left side cover to access the connector on the motor. - If continuity exists on each wire, then replace the main motor gear drive which includes the motor. - If continuity does not exist on one or more of the wires, then call the next level of support. • If these voltages are not correct, then see "Controller board connector pin values" on page 5-2, or replace the controller board. See "Controller board removal" on page 4-6. 2-26 Lexmark™ E360d, E360dn