Lexmark E460 IPDS Emulation User's Guide - Page 103

Print a POSTNET Advance Bar Code ABC bar code symbol., International Prefix, Outward Code

Page 103 highlights

Type Bar Code Type Mod Description POSTNET bar code symbology. These fields are ignored because the POSTNET symbology defines specific values for these parameters. X'00' Print a POSTNET ZIP Code bar code symbol. X'01' Print a POSTNET ZIP+4 (delivery point) bar code symbol. X'02' Print a POSTNET Advance Bar Code (ABC) bar code symbol. X'03' Print a POSTNET variable-length bar code symbol. The bar code symbol is generated without length checking; the symbol is not guaranteed to be scannable or interpretable. The bar code consists of a leading frame bar, the encoded data, a correction digit, and a trailing frame bar. X'04' PLANET Bar Code. Print a POSTNET PLANET bar code symbol. This is a "reverse topology" of POSTNET; tall bars are swapped with short bars. X'1A' RM4SCC (Royal Mail 4-State Customer Code) A 4-state customer code defined by the Royal Mail Postal service of England for use in bar coding postal code information. This symbology is also called the Royal Mail bar code or the 4State customer code. The symbology (as defined for modifier X'00') is used in the United Kingdom and in Singapore. 'X'00' Print an RM4SCC bar code symbol with a printer generated start bit (start bar), checksum character, and a stop bit (stop bar). The start and stop bars identify not only the beginning and end of the bar code symbol, but also the orientation of the symbol. Input data is of variable length. The checksum algorithm is performed on the data characters only. The user is responsible for 2 mm quiet zone (all around) and proper sequencing of the Postal Code data (including International Prefix, Outward Code, Inward Code and Delivery Point Suffix). X'1A' RM4SCC (Dutch KIX Postal Bar Code) X'01' This is a variation used in the Netherlands. KIX = KlantenIndeX = customer index. Print a RM4SCC bar code symbol with NO start bar, NO checksum digit and NO stop bar. The checksum algorithm is performed on the data characters only. The user is responsible for 2 mm quiet zone (all around) and proper sequencing of the Postal Code data (including 103

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119

Type
Bar Code Type
Mod
Description
X’00’
X’01’
X’02’
X’03’
X’04’
POSTNET bar code symbology. These fields are ignored
because the POSTNET symbology defines specific values for
these parameters.
Print a POSTNET ZIP Code bar code symbol.
Print a POSTNET ZIP+4 (delivery point) bar code symbol.
Print a POSTNET Advance Bar Code (ABC) bar code symbol.
Print a POSTNET variable-length bar code symbol. The bar
code symbol is generated without length checking; the symbol is
not guaranteed to be scannable or interpretable.
The bar code
consists of a leading frame bar, the encoded data, a correction
digit, and a trailing frame bar.
PLANET Bar Code.
Print a POSTNET PLANET bar code symbol. This is a “reverse
topology” of POSTNET; tall bars are swapped with short bars.
X’1A’
RM4SCC (Royal
Mail 4-State
Customer Code)
’X’00’
A 4-state customer code defined by the Royal Mail Postal
service of England for use in bar coding postal code information.
This symbology is also called the Royal Mail bar code or the 4-
State customer code. The symbology (as defined for modifier
X’00’) is used in the United Kingdom and in Singapore.
Print an RM4SCC bar code symbol with a printer generated start
bit (start bar), checksum character, and a stop bit (stop bar). The
start and stop bars identify not only the beginning and end of the
bar code symbol, but also the orientation of the symbol. Input
data is of variable length.
The checksum algorithm is performed on the data characters
only.
The user is responsible for 2 mm quiet zone (all around) and
proper sequencing of the Postal Code data (including
International Prefix, Outward Code, Inward Code and Delivery
Point Suffix).
X’1A’
RM4SCC (Dutch
KIX Postal Bar
Code)
X’01’
This is a variation used in the Netherlands. KIX = KlantenIndeX
= customer index.
Print a RM4SCC bar code symbol with NO start bar, NO
checksum digit and NO stop bar. The checksum algorithm is
performed on the data characters only.
The user is responsible for 2 mm quiet zone (all around) and
proper sequencing of the Postal Code data (including
103