Lexmark X651DE Forms and Bar Code Technical Reference

Lexmark X651DE - Mfp Laser Mono P/f/s/c Manual

Lexmark X651DE manual content summary:

  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 1
    Forms and Bar Code Card Technical Reference Manual March 2009 www.lexmark.com
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 2
    programs described may be made at any time. For Lexmark technical support, visit support.lexmark.com. For information on supplies and downloads, visit www.lexmark.com. If you don't have access to the Internet, you can contact Lexmark by mail: Lexmark International, Inc. Bldg 004-2/CSC 740 New Circle
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 3
    /or its subsidiaries Microsoft Corporation All other trademarks are the property of their respective owners. © 2009 Lexmark International, Inc. All rights reserved. UNITED STATES GOVERNMENT RIGHTS This software and any accompanying documentation provided under this agreement are commercial computer
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 4
    data formats 8 Checksum calculation 8 Visual Bar Code Designer 8 HP BarDIMM compatibility intercept 8 Supported Lexmark PCL5 & PostScript Bar Codes 8 Chapter 4: PCL5 emulation: HP 12 One-dimensional bar codes 12 Defining characteristics 12 Command structure considerations 12 Transparent
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 5
    data 28 Chapter 5: PCL5 emulation: Lexmark 29 New PCL5 commands to support bar codes 29 Bar code descriptor ESC&x#W[descriptor data 29 Transfer bar code data ESC&y#W[bar code data 29 Compatibility safeguard 29 Lexmark symbology assignments 31 One-dimensional bar codes 32 Post 4-State
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 6
    94 Data types ...95 Data filters ...96 Forms Card font support 96 Bubble font 97 Determine printable characters 99 Printing errors 99 Forms files on printer directory 100 Appendix A: Feature Summary 101 Appendix B: Supported Bar Codes 104 Appendix C: Forms Card Fonts 128 Single-Byte
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 7
    common to all symbologies 149 String errors 149 Errors specific to symbologies 151 Appendix F: Deviations 153 Code 93 uppercase vs. lowercase 153 Codabar uppercase vs. lowercase 153 Maximum encodable character length 154 Four-state Postal
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 8
    new features: • Three new Forms Card menu options: - Print All Forms-Allows a user to print information about all formsets stored on a printer, as well as some printer-specific information. - Print Port Setting-Allows a user to select which of the printer input ports the FormsMerge DLE performs
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 9
    of this document's detail into a user-friendly bar code design graphical interface to easily generate PCL5 and PostScript data • SAP R/3 device types and associated installation instructions • Some demonstration and test files • A Readme file that includes download information, requirements, and
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 10
    Pro products) 2 Using special Lexmark advanced PCL5 commands for bar codes Most of the bar code symbologies supported by the Forms and Bar Code positioning applies with or without human-readable text. Human-readable text One-dimensional symbologies Human-readable text can be specified with the bar
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 11
    use within SAP or other applications. HP BarDIMM compatibility intercept The LexmarkTM Forms and Bar Code Card meets the function of the HP BarDIMM Pro version 3.3a option. Supported Lexmark PCL5 & PostScript Bar Codes The following is a list of supported one-dimensional bar codes: • Australian Post
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 12
    • Code 3 of 9 space encoding • Code 3 of 9 space encoding with check digit • Code 93 • Code 93 extended • Danish PTT 3 of 9 • Dutch Post 4-state bar code • EAN/JAN-8 • EAN/JAN-8 with 2-digit supplemental • EAN/JAN-8 with 5-digit supplemental • EAN/JAN-13 • EAN/JAN-13 with 2-digit supplemental • EAN/
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 13
    Data Matrix • MaxiCode • MicroPDF417 • PDF417 • QR Lexmark-Unique PCL5 Command Description Support of new bar code functionality is not available in HP flushed. # is the number of bytes of bar code data. Compatibility Safeguard These two new commands, if sent to an HP printer, are flushed and nothing
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 14
    of these commands and to ignore them in a bar code context. To avoid this conflict, use the PCL5 Lexmark enhancement switch. Setting or not setting this switch would allow a future Lexmark PCL5 emulation to decide which way to interpret the new escape sequences. The switch is a GL/2 command. HP
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 15
    additional Lexmark-specific section is found immediately following this section. One-dimensional one of those given, special bar code generation firmware processes the font selection command. If the typeface value is not one followed when implementing bar code applications using the Forms and Bar
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 16
    text font. Example: Esc(s1p10v0s0b4101T Returns the text following a bar code to 10-point CG Times with proportional spacing, normal style and medium stroke weight One-dimensional bar codes 13
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 17
    Print text half embedded 4 = Print text under bar code 5 = Print text above bar code Add the numbers listed below to produce the corresponding effect: 10 = 10 = 20 = 100 = Prints UPC-A checksum b2, s2 h .4 inch .01 inch .03 inch automatically sized Courier Bold One-dimensional bar codes 14
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 18
    0.5 inch. Because the p, b, s and h parameters are not specified, their values default to: p b1, s1 b2, s2 h Do not print text .01 inch .03 inch Not applicable because of #p parameter value One-dimensional bar codes 15
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 19
    values default to: v .4 p Do not print text s1 .01 inch s2 .03 inch h Not applicable because of #p parameter value Selects space widths in dots (1/600 inch). Some bar codes, such as Interleaved values default to: v .4 h automatically sized Courier Bold One-dimensional bar codes 16
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 20
    sized Courier Bold). 2 Does not include checksum character. 3Checksum character is always printed if embedded text is specified. * = Fixed value, cannot be changed N = Numeric M = Mixed One-dimensional bar codes 17
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 21
    be changed N = Numeric M = Mixed Yes No No No Yes No Yes No Yes No Yes Yes3 Yes3 No Yes Yes Yes Yes Yes Yes Yes One-dimensional bar codes 18
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 22
    24 32 N 13 * = Fixed value, cannot be changed N = Numeric M = Mixed Yes3 Yes No Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Y Y Y One-dimensional bar codes 19
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 23
    Table field byte 7 of the Lexmark bar code descriptor for Australia 4-State Postal bar codes (see the section "PCL5 emulation: Lexmark" on page 29 of this manual). Human-readable text is never printed Ascender, Descender Offset (in 1/100 mm Fixed at 195 units): One-dimensional bar codes 20
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 24
    a "blank space" in the symbol equal to two space widths, and does not produce an error message. If an invalid character follows a valid character in the data, the blank space produced by the invalid character begins one space width from the right end of the base of the bar produced by the
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 25
    item identification with Indicator digits of zero or one in a linear symbol for use on small items that will not be scanned at the point-of-sale. • RSS wide for the application. It comes in two versions: - a RSS Truncated version for small item marking applications, and; One-dimensional bar codes 22
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 26
    which can be scanned omnidirectionally. Note: The RSS Stacked Omnidirectional bar code is not supported by the Forms There is no maximum value but larger barcodes may use up too much memory. 8,16,24,32 (dec) or 8,10,18,20 (hex) specific RSS bar code type. Optional. Selects the width of the bars
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 27
    default V parameter values (in the above table) are slightly different than HP, and match the RSS-14 AIM specification values. • Each of the V parameter values (For Forms and Bar Code Card: 33, 13, 13, 10 and Bar Code Card like it does on other one-dimensional bar codes. One-dimensional bar codes 24
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 28
    much memory. number of rows in the Codablock F symbol. Optional. Requested number one of the rows contained in the bar code. No provision is made to specify the absolute height of the Codablock F symbol. Parameters V2 and V3 are derived from the ELMICRON Specification. The HP BarDIMM Pro specification
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 29
    number (B parameter) is documented by HP in their reference manual, but varying B1 or B2 does not affect the larger barcodes may use up too much memory. Description Required. 24820T Optional. Small 10 (default). Notes: • The HP BarDIMM specification contains only the PCL "B" parameter by itself
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 30
    number of columns for the symbol; range is 1-30 Optional; determines the X-value of the symbol aspect ratio Optional; determines the Y-value of the symbol aspect ratio 0 = Parameters #1 and #2 will equal the size needed for the PDF relation to the fields of the Lexmark bar code descriptor for PDF417,
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 31
    as follows: • 0 = Default ECC level (error correction level M of 15%) • 1 = number field, a number-of-labels field, and a mode field. All three of these fields are one digit in length and are terminated with either a comma or Group Separator (GS, ASCII 29). In relation to the fields of the Lexmark
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 32
    descriptor is sent, then this command is ignored and the data is flushed. The number of bytes of descriptor data is indicated by #. Compatibility safeguard These two new commands, if sent to an HP printer, are flushed and nothing prints. There is a possibility that a future HP PCL5 enhancement could
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 33
    19 20-39 40-99 100-199 Type of symbology Two-dimensional symbologies 4-State bar codes Miscellaneous symbologies One-dimensional bar codes For new one-dimensional bar codes, the Lexmark bar code descriptors all have the same initial 14 fields, patterned after the font-like parameter sequence used
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 34
    112 00 71 113 00 72 114 00 73 115 00 80 128 ISBN, ISBN+5 ISSN, ISSN+2, ISSN+5 Swiss Post ITF-14 HIBC 39 Provider Application Standard HIBC 39 Supplier Labeling Standard HIBC 128 Provider Application Standard HIBC 128 Supplier Labeling Standard PLANET PCL5 emulation: Lexmark 31
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 35
    One-dimensional bar codes Post 4-State bar code descriptors (Lexmark 19 (hex) 22-25 (dec) 18 (hex) 24 (dec) Sets the number of bars that print per inch 4 Tracker Height 64-A0 (hex) 100-160 error. Invalid characters in the customer information string will be flagged with an error. Length errors
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 36
    3 Bar Pitch 14-18 (hex) 20-24 (dec) 16 (hex) 22 (dec) Sets the number of bars that print per inch 4 Tracker Height 66-98 (hex) 102 -152 (dec) 7F characters or lengths will be flagged with an error. String lengths of 4 characters imply a BRS license number. One-dimensional bar codes 33
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 37
    14-18 (hex) 20-24 (dec) 16 (hex) 22 (dec) Sets the number of bars that print per inch 4 Tracker Height 66-98 (hex) 102-152 (dec tracker height 6-15 Reserved Note: All seven code formats are supported. The format will be implied on the type of data from byte 2) One-dimensional bar codes 34
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 38
    as part of the block and house number information are encoded as data in the bar code. • Invalid characters or lengths in the postal code will be flagged with an error. • Invalid characters in the block and house number information will be flagged with an error. One-dimensional bar codes 35
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 39
    hex) 22 (dec) Sets the number of bars that print per inch error message. FIM symbols are printed according to the USPS specification. Bar height is fixed at 5/8 inch, and bars and spaces have a fixed width of 1/32 inch. Cursor positioning is handled the same as for one-dimensional symbologies. One
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 40
    mm for module widths less than or equal to 0.45 mm • greater than or equal to 23 mm for module widths greater than 0.45 mm One-dimensional bar codes 37
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 41
    digit post code, • a 2-digit billing district code, • a 6-digit customer account number, and • an 8-digit item number. To enhance readability, "." characters (ASCII 46) may appear anywhere in the data; they lengths in the identification code will be flagged with an error. One-dimensional bar codes 38
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 42
    (in bar/space width units, see byte 8) #b4 parameter (in bar/space width units, see byte 8) #s4 parameter (in bar/space width units, see byte 8) One-dimensional bar codes 39
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 43
    (anything other than a digit or a "-", except for an "X" in the tenth digit position) in the data produces an error message. Cursor positioning is handled the same as for other one-dimensional symbologies. If the Units bytes 5 or 8 are changed from their default values, then the Bar Height and Bar
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 44
    (in bar/space width units, see byte 8) #b4 parameter (in bar/space width units, see byte 8) #s4 parameter (in bar/space width units, see byte 8) One-dimensional bar codes 41
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 45
    for an ISSN symbol consists of an 8-digit ISSN, followed by a two-digit price code, optionally followed by a two- or five-digit add-on code. If digit position) in the data produces an error message. Cursor positioning is handled the same as for other one-dimensional symbologies. If the Units bytes 5
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 46
    Regular only. 0=Default (1/600" units) 1=1/300" units 2=1/600" units 3=1/1200" units • 0 or 2 (dec) or • 00 or 02 (hex) Optional. Specifies units for bar height dimensions. One-dimensional bar codes 43
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 47
    39 narrow space widths are both 0.01 inches. If byte 5 is default 00 (600 dpi), then the Space Width is 6, which is 00 06 hex. One-dimensional bar codes 44
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 48
    1.25984 inches. If byte 5 is default 00 (600 dpi), then the Bar Height is 755.9 (or 756) Bar Height Units, which is 02 F4 hex. One-dimensional bar codes 45
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 49
    , Default = 2.50 x Bar Width 1 Optional. Note: Values that go beyond the defined range will be appropriately clipped and set to the minimum and maximum values. One-dimensional bar codes 46
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 50
    (dec) or 18 (hex) result in a pitch of 24. Notes: • PLANET is called from PCL using the block-call method. • For more information on the specifications implemented on the PLANET code, refer to Appendix B and C of the USPS PLANET
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 51
    Two-dimensional bar codes Bar code descriptor for PDF417 (Lexmark) Bytes 0-1 MSB LSB Range Symbology Symbology n/a ID byte 1 ID byte 2 (00x) (03x) 2-3 Reserved Units 0=Default 1=1/300" units 2=1/600" units 3=1/1200" units 4-5 X X 240-12000 (dec) dimension
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 52
    values. Sets the Y dimension of the module (white or black rectangle) in one-hundredths of an inch. The default width of this element from the BCE is 1-4 (dec) • 0 (dec) Optional. or • 00 (hex) Manually set the number of symbol rows. Automatic operation specified by using 0. See Section 9.5.3 Row
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 53
    00x 01x 02x 03x 04x 05x 06x 07x 08x Number of error code words 2 4 8 16 32 64 128 in specifying the X Dimension (the smallest element width). Supported values are 01x for 300 dpi units, 02x for 600 Default = 00x) This can be used to manually set the number of symbol rows. Both rows and columns must
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 54
    Note: When manually setting the number of symbol rows number of data code words in the symbol. For example, if there are 20 data code words in a symbol, and ECC percentage is specified at 100% (0064x), then the predetermined ECC level selected will be the one closest to 20, or ECC level 3 (16 error
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 55
    04x 05x 06x Description Structured carrier message with numeric postal code Structured carrier message with alphanumeric postal code Standard symbol with standard error correction Full symbol with enhanced error correction Reader program with standard error correction Two-dimensional bar codes 52
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 56
    on PDF417 and is used for small area applications that require greater area efficiency but lower data capacity than PDF417. MicroPDF417 is distinctive from PDF417 in that the symbol may only be produced within specific row, column and error correction codeword combinations, up to a maximum of four
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 57
    widths are permitted, each specifying the number of data columns (1 - 4). Within each symbol width a variable number of rows (4 - 44) modes. The support of NULL (hex 00) characters is not supported at this time, due to possible issues with string termination within the printer. The basic block
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 58
    , the Y dimension will become double that of the X-dimension. 0 (dec) or 00 (hex) Optional. Manually set the number of symbol rows. Automatic operation specified by using 0. Manually set the number of symbol columns. Automatic operation specified by using 0. Bar code descriptor for MicroPDF417 55
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 59
    the primary identification is readable by all scanning technologies, and so that 2D imagers area-CCD scanners, and with linear and rastering laser scanners. The following bar codes allow the addition bar code, as observed above. a Number System: The number system is a single digit which identifies
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 60
    Digit: The check digit is an additional digit used to verify that a bar code has been scanned correctly. Since a scan can produce incorrect data due to inconsistent scanning speed, print imperfections, or a host of other problems, it is useful to verify that the rest of the data in the bar code has
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 61
    encoded with odd and even parity from the left-hand columns of the EAN-13 character. The parity used for each character depends on the number system (0 or 1) and the check digit from the original UPC-A barcode. 3 EAN-8 (including +2 and +5 variants) EAN-8 is the EAN equivalent of UPC-E in the sense
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 62
    Association (EAN) in Europe. The only difference between a UPC-A symbol and an EAN-13 symbol is that the number system code is 2-digits long in EAN-13 as opposed to one digit in UPC-A. An EAN-13 bar code has the following physical structure: a Left-hand guard bars, or start sentinel, encoded
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 63
    128 encodes data and encodes what that data represents. It has a list of "Application Identifiers" (AI) to include additional data such as best before dates, batch numbers, quantities, weights and many other attributes needed by the user. Each AI tells the system what kind of data will follow and in
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 64
    with Indicator digits of zero or one in a linear symbol for use on small items that will not be scanned at the point-of-sale. RSS the user. The sequence stands for ESCape, or 1Bh. For example, this is a RSS-14 Composite bar code sequence: (s36b24810T01234567890123|Lexmark
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 65
    PCL Specifications for composite bar codes Field Name Type Range Default (if not specified) Definition Symbology ID int - - Required. 24600T specifies UPC-A 24601T specifies UPC-A+2 24602T specifies
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 66
    Bitmap Bitmap Scalable Scalable Scalable Scalable Scalable Bitmap Scalable Scablable Bitmap Resides On option card On option card On option card On option card In printer In printer In printer On option card On option card On option card On option card On option card On option card Fonts 63
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 67
    data. Not all systems are able to send binary data (non printing characters) to a printer. The FREESCAPE emulation feature provides a way for these systems to redefine the escape character by substituting a user-selected alternative (alternate escape code or AEC). When the AEC is located at the
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 68
    # represents the ASCII code of the AEC. Use one of the ASCII codes listed: Command Function/Parameter Esc**#J printer control panel: 1 From the Forms Card menu, select Alt ESC Code. 2 Select On to enable the AEC. 3 From the Forms Card menu, select Alt ESC Code Char. 4 Select an AEC from the menu
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 69
    characters. When an invalid condition is detected, an error message is generated. For more information, see "PostScript error messages" on page 148. There are certain command structure considerations to follow when implementing bar code applications using the Forms and Bar Code Card. Characteristic
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 70
    the bounding box. Human-readable text Human-readable text can be specified with one-dimensional bar codes under the following provisions: • The typeface to be used places the character(s) per the symbology specifications. Fixed length data formats can be sent with or without checksum
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 71
    PostScript emulation operator Operator barcodeshow Function/parameters String dict barcodeshow This function paints the specified bar code symbol at the currentpoint and advances the currentpoint by the symbol's displacement (as returned by the barcodewidth operator). This is similar to the show
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 72
    Operator barcodebbox barcodewidth Function/parameters String dict barcodebbox llx lly urx ury This function returns the coordinates for the bounding box that would enclose the specified bar code symbol if it were shown by a barcodeshow. This is similar to the pathbbox operator. Example: (123456)
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 73
    Arguments for one-dimensional bar codes Key Type Definition /Symbology name Required, see "Values for /Symbology key" on page 72 for valid 1For the French postal symbology, /Special and /PrintCheckChar are always true and cannot be changed to false. Arguments for one-dimensional bar codes 70
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 74
    half the height of the text 1For the French postal symbology, /Special and /PrintCheckChar are always true and cannot be changed to false. Arguments for one-dimensional bar codes 71
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 75
    , cannot be changed N = Numeric M = Mixed No Yes Yes Yes Yes Yes No Yes No Yes Yes Yes Yes3 Yes3 Yes3 Yes3 Yes3 Yes3 Arguments for one-dimensional bar codes 72
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 76
    Interleaved 2 of 5 with 240 1 6 check digit International Standard 620 3 8 Book Number International Standard 620 3 8 Serial Number 18 N odd Yes 16 24 32 N5 104 Yes3 16 24 32 N5 104 Yes3 * = Fixed value, cannot be changed N = Numeric M = Mixed Arguments for one-dimensional bar codes 73
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 77
    * / or | * = Fixed value, cannot be changed N = Numeric M = Mixed Yes Yes Yes Yes Yes3 Yes3 Yes3 Yes3 Yes3 Yes3 Yes3 No No No No Arguments for one-dimensional bar codes 74
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 78
    regular bold italic bold italic regular bold italic bold italic regular bold italic bold italic regular bold italic bold italic regular bold italic Arguments for one-dimensional bar codes 75
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 79
    BoldItalic /OCR-B Example: /FontName /Courier Font attribute for HRT bold italic only one style How to use the symbology ID for ISBN and ISSN ISBN and ISSN findfont 12 scalefont 200 400 moveto (012345678934567) > barcodeshow showpage Arguments for one-dimensional bar codes 76
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 80
    ] 24 (dec) [integer] 130 (dec) [integer] 185 (dec) [integer] 11 (dec) [integer] Description Symbology identification Sets the bar width in 1/100 mm Sets the number of bars that print per inch Sets the tracker height in 1/100 mm Sets the ascender and descender offset in 1/100 mm; the total height
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 81
    integer] 127 (dec) [integer] 188 (dec) [integer] [150 150] [array of integers] Description Symbology identification Sets the bar width in 1/100 mm Sets the number of bars that print per inch Sets the tracker height in 1/100 mm Sets the ascender and descender offset in 1/ 100 mm; the total height
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 82
    integer] 127 (dec) [integer] 188 (dec) [integer] [150 150] [array of integers] Description Symbology identification Sets the bar width in 1/100 mm Sets the number of bars that print per inch Sets the synchronization bar height in 1/100 mm Sets the upward and downward bar height in 1/100 mm Optional
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 83
    Key /QuietZone /Units Range [int int] Default value [150 150] [array of integers] Description Same as the other bar codes, in /Units (optional) 1/600 inch (optional) /BarHeight must be: • greater than or equal to 20 mm for module widths less than or equal to 0.45 mm (0.0177 inches) • greater
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 84
    Two-dimensional bar codes HIBC 39/128 Key /Symbology Type name /Units /Height name int /Bars [int] /Spaces [int] /EmbedText name Range Default value Description n/a n/a Required. /HIBC128PAS /HIBC128SLS /HIBC39PAS /HIBC39SLS /300ths /600ths /1200ths /600ths Optional. /Units is
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 85
    : • If the value is of type name, the value will be set to default (/Courier-Bold) • If the value is of any other type, a TYPECHECK error will be returned. Min: [0 0] (dec) Max: [1200 1200] (dec) • [150 150] (dec) or • [96 96] (hex) Optional. Note: Values less than the minimum will use
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 86
    in the calculations below. Min: 307 (dec) 01 33 (hex) Max: Ther is no maximum value, but larger bar codes may use up too much memory. • 756 (dec) or • 02 F4 (hex) Optional. Note: Values that go beyond the defined range will be appropriately clipped and set to the minimum and
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 87
    the value will be set to default (/Courier-Bold) • If the value is of any other type, a TYPECHECK error will be returned. Min: [0 0] (dec) Max: [1200 1200] (dec) • [150 150] (dec) For more information on the specifications implemented on the PLANET code, refer to Appendix B and C of the USPS PLANET
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 88
    or 1 for /Rows and /Columns determined by /AspectRatio Required if /Type = 0; manually sets number of symbol rows; valid values are 3 to 90; any values outside this range will cause a RANGECHECK error Required if /Type = 0; manually sets number of symbol columns; valid values are 1 to 30; any values
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 89
    non-zero percentage is specified, the error correction level will be computed by selecting one of the /ErrorLevel values (0-8).The error correction level selected will be the one that best matches the number generated by multiplying the specified percentage by the number of data code words in the
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 90
    %height / width ratio is 1 / 2 %smallest element width in 600th units %smallest element width = 20/600ths %bar height = 40/600ths %number of error code words = 8 %because they are not specified, /Truncated defaults to %false (no ;truncation) and / QuietZone defaults to [150 150] Arguments
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 91
    supported number-of-labels field. Both fields are one digit in length and are terminated with either a comma or Group Separator (GS, ASCII 29). • For modes 2 and 3, there are 3 extra fields that must follow the label fields. These include the postal code, country code, and class of service AIM spec).
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 92
    moved to the secondary message. Neither a group separator nor a comma should terminate this message. An optional secondary message follows the class of service for modes 2 and 3. For modes 4, 5, and 6, the message follows the number-of-labels field. Arguments for MaxiCode bar code symbology 89
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 93
    MicroPDF 417 Key /Symbology Type name /Units name /ModuleWidth int /ModuleHeight int /Rows int /Columns int Range n/a /300ths /600ths /1200ths 240-12000 (dec) 48060000 (dec) Note: The range of Y dimension is dependent on the value of X dimension, such that, Min = 2 * Xdimension Max = 5 *
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 94
    : • If the value is of type name, the value will be set to default (/Courier-Bold) • If the value is of any other type, a TYPECHECK error will be returned. Min: [0 0] (dec) Max: [1200 1200] (dec) • [150 150] (dec) or • [96 96] (hex) Optional. Note: Values less than the minimum will use
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 95
    , the sequence uses the "pipe" character "|" to extend the sequence. For example, this is a UPC-A Composite example sequence: (12345678901|Lexmark) > barcodeshow • UPC-A data begins with "12345678901" • Followed by a "|" pipe character • Followed by the Composite data string
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 96
    dimentional module (white or black rectangle) in one-hundreths of an inch. /EmbedText (of If the value is of any other type, a TYPECHECK error will be returned. The data in a Postscript bar code is a UPC-A Composite example sequence: (12345678901|Lexmark) > barcodeshow • UPC
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 97
    following information is a supplement to the instructions provided in the Forms and Bar Code Card User's Guide. 1 Enhanced page delimiters The Forms only on MFPs that support e-mail and/or fax. 3 Select ports that the Forms Card listens to Users can now select which of the printer input ports that
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 98
    Forms Card firmware. The PDF is then parsed by the PDF interpreter inside the printer. Note: This option requires a printer that supports RFID functionality. 6 Print All Forms Users can print information about all the formsets stored on the printer, as well as some printer-specific information. This
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 99
    The following information is a supplement to the Forms Menu information provided in the Forms and Bar Code Card User's Guide. If a data filter is enabled, the except uses the '@' as the "format instruction" prefix Forms Card font support Not all fonts are recognized by the Forms and Bar Code Card
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 100
    Card Fonts" on page 128 identifies all supported/recognized fonts and the font file used by the Forms and Bar Code card. Bubble font This font is typically used for standardized testing forms that are optically read for grading purposes. It is available in Lexmark Forms Composer when the font "OCRB
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 101
    Bubble font 98
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 102
    richer than that of the printer, a user could easily create a form where not all characters will print. This Technical Reference cannot define what is standard and non-standard, as those definitions change for each geographic location. The user stipulates a supported code page via the Forms Composer
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 103
    files on printer directory The Forms and Bar Code Card places forms files on the printer in the "formsmerge" directory. These files will be visible if the user performs a Print Directory from the printer menu. These files must not be tampered with in any way. Forms files on printer directory 100
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 104
    supported on various Lexmark products: Forms and Bar Code Card Forms Card Filters PCL5 Filter Y Optra FormsTM Init String Y • Supports file names Y1 Y Y 1 Supported when the printer control panel is set to a DBCS language. 2 Limited UTF-8 and UTF-16 support (no Asian fonts or file names
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 105
    Y NA Error Page Control Printer Operator NA NA NA Panel Sel. Fax form output (MFP feature) Y NA Y NA E-mail form output (MFP Y NA Y NA feature) System variables in formset • PRINTNAME (Printer name) Y Y NA NA • PRINTNUM (Printer Serial Y number) Y NA NA Save Variable
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 106
    Single Char. Variable Subform Activ. Downloadable DBCS fonts Forms flash file UTF-8 File Y • OCR B Y Y Y • PLANET Y Y Y 1 Supported when the printer control panel is set to a DBCS language. 2 Limited UTF-8 and UTF-16 support (no Asian fonts or file names, etc.) 3 Requires an RFID-enabled
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 107
    using Optra FormsTM only when the Bar Code Option is also installed in the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported by the Bar Code Card version 2.4 or later can be printed with Optra FormsTM
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 108
    Bar Code Card v3.1 LDSS Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name Codablock F Y3 Y Y Y Sample the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported by
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 109
    and Bar Code Card v3.1 LDSS Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name Code 93 Sample Image Y Y Y Y the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 110
    128A Comments Code 128, also sometimes called USS 128 (Uniform Symbol Specification), is a general-purpose bar code that can handle any ASCII the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 111
    and Bar Code Card v3.1 LDSS Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name HIBC128, HIBC 39 Y3 Y Y Y Sample printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 112
    and Bar Code Card v3.1 LDSS Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name Interleaved 2 of 5 Sample Image Y Y printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 113
    Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name Matrix 2 can accept a variable number of digits up to 13 applications printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 114
    high-speed scanning application of package sorting and tracking. 1 PDF417 and MaxiCode can be printed using Optra FormsTM only when the Bar Code Option is also installed in the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 115
    LDSS Document Producer Lexmark Optra FormsTM Bar is designed for applications with a need with a fixed level of error correction for each symbol size printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 116
    and Bar Code Card v3.1 LDSS Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name QR Y Y Y Y Sample Image the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported by
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 117
    v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name supplementary data, such as a batch number or expiration date). The linear component printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 118
    and Bar Code Card v3.1 LDSS Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name Composite + EAN Y3 Y Y Y Sample the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 119
    and Bar Code Card v3.1 LDSS Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name Composite + RSS-14 Y3 Y Y Y the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported by
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 120
    Producer Lexmark Optra error detection. Only 8-digit numeric data can be used with this code. EAN-8 supports a supplemental two- or five-digit number printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 121
    LDSS Document Producer Lexmark Optra FormsTM Bar Code number. The last digit is the checksum. EAN-13 supports a supplemental two- or five-digit number printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 122
    number of the serial publication. 1 PDF417 and MaxiCode can be printed using Optra FormsTM only when the Bar Code Option is also installed in the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 123
    v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code scanning. It encodes 14 digits of numerical data used to identify Global Trade Item Numbers printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 124
    Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name UPC-A supplemental two- or five-digit number to be appended to the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 125
    Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name UPC-E by "suppressing" the first (number system) digit, trailing zeros printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 126
    Card v3.1 LDSS Forms Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name Postal Bar Code Symbologies Australia in the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported by the
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 127
    Lexmark number, and a check digit. 1 PDF417 and MaxiCode can be printed using Optra FormsTM only when the Bar Code Option is also installed in the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 128
    using Optra FormsTM only when the Bar Code Option is also installed in the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported by the Bar Code Card version 2.4 or later can be printed with Optra FormsTM
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 129
    Lexmark number, and an 8-digit item number. USPS FIM (Face Identification Marking) Y Y Y Y Y FIM is used by the United States Postal Service printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 130
    Composer v3.3.9 LDSS Document Producer Lexmark Optra FormsTM Bar Code Name the 3-digit content identifier number (CIN) applicable to the content of the printer, and when the accompanying bar code dictionaries have been installed in Optra FormsTM . 2 All one-dimensional bar code symbologies supported
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 131
    C Forms Card Fonts Single-Byte Forms Card Fonts The column on the left indicates common font names. The column on the right indicates the actual font file resident on the Forms card. Font name AdobeSansMM AdobeSerifMM Albertus Extra Bold (W1) Albertus Medium (W1) Albertus MT Albertus MT Lt
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 132
    Font name AntiqueOliveCE-Roman AntiqueOlive-Compact AntiqueOlive-Italic AntiqueOlive-Roman Apple Chancery Apple-Chancery Apple-ChanceryCE Architext CMC7 Arial Arial Black Arial Bold Arial Bold Italic Arial Italic Arial-Bold Arial-BoldItalic Arial-BoldItalicMT Arial-BoldMT ArialCE ArialCE-Bold
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 133
    Font name AvantGardeCE-DemiOblique AvantGarde-Demi AvantGarde-DemiOblique Bodoni Bodoni Poster Bodoni PosterCompressed Bodoni-Bold Bodoni-BoldItalic BodoniCE BodoniCE-Bold BodoniCE-BoldItalic BodoniCE-Italic BodoniCE-Poster BodoniCE-PosterCompressed Bodoni-Italic Bodoni-Poster Bodoni-
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 134
    Font name CenturySchlbk Roman CenturySchlbk-Bold CenturySchlbk-BoldItalic CenturySchlbk-Italic CenturySchlbk-Roman CG Omega (W1) CG Times (W1) CG Times (W1) Bold CG Times (W1) Bold Italic CG Times (W1) Italic CG Times (WE) CG Times (WE) Bold CG Times (WE) Bold Italic CG Times (WE) Italic CG Times (
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 135
    Font name CGOmega-BoldItalic CG-Omega-BoldItalic CGOmega-Italic CG-Omega-Italic CGTimes CG-Times CGTimes-Bold CG-Times-Bold CGTimes-BoldItalic CG-Times-BoldItalic CGTimes-Italic CG-Times-Italic Chicago ChicagoCE Clarendon Clarendon Condensed (W1) Clarendon Light Clarendon-Bold ClarendonCE
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 136
    Font name Coronet-Regular Courier Courier New Courier New Bold Courier New Bold Italic Courier New Italic Courier-Bold Courier-BoldItalicTT Courier-BoldOblique Courier-BoldTT CourierCE CourierCE-Bold CourierCE-BoldOblique CourierCE-Oblique CourierHP CourierHP-Bold CourierHP-BoldItalic CourierHP-
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 137
    Font name Garamond (W1) Kursiv Garamond (W1) Kursiv Halbfett Garamond-Antiqua Garamond-Halbfett Garamond-Kursiv Garamond-KursivHalbfett Geneva GenevaCE GillSans GillSans Condensed GillSans ExtraBold GillSans Light GillSans-Bold GillSans-BoldCondensed GillSans-BoldItalic GillSansCE-Bold GillSansCE-
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 138
    Font name Goudy-BoldItalic Goudy-ExtraBold Goudy-Italic Helvetica Helvetica Bold Helvetica Bold Italic Helvetica Condensed Helvetica Italic Helvetica-Black Helvetica-Black Bold Helvetica-Black Bold Italic Helvetica-BlackOblique Helvetica-Bold Helvetica-BoldItalic Helvetica-BoldOblique HelveticaCE
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 139
    Font name Helvetica-Condensed-Oblique Helvetica-Italic Helvetica-Light Helvetica-Light Italic Helvetica-LightOblique Helvetica-Narrow Helvetica-Narrow Bold Helvetica-Narrow Bold Italic Helvetica-Narrow Italic Helvetica-Narrow-Bold Helvetica-Narrow-BoldItalic Helvetica-Narrow-BoldOblique Helvetica-
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 140
    Font name Intl-Courier-Oblique Intl-Univers-Bold Intl-Univers-BoldItalic Intl-Univers-Condensed-Bold Intl-Univers-Condensed-BoldItalic Intl-Univers-Condensed-Medium Intl-Univers-Condensed-MediumItalic Intl-Univers-Medium Intl-Univers-MediumItalic JoannaMT JoannaMT-Bold JoannaMT-BoldItalic JoannaMTCE
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 141
    Font name LubalinGraphCE-BookOblique LubalinGraphCE-Demi LubalinGraphCE-DemiOblique LubalinGraph-Demi LubalinGraph-DemiOblique ManufIcons Marigold Marigold (W1) MICR Mona Lisa Recut Monaco MonacoCE MonaLisa-Recut New York NewCenturySchlbk-Bold NewCenturySchlbk-BoldItalic NewCenturySchlbkCE-Bold
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 142
    Font name Optima-Italic Oxford Palatino Bold Palatino Bold Italic Palatino Italic Palatino Roman Palatino-Bold Palatino-BoldItalic PalatinoCE-Bold PalatinoCE-BoldItalic PalatinoCE-Italic PalatinoCE-Roman Palatino-Italic Palatino-Roman RomanPillar RomanPillar Bold RomanPillar BoldItalic RomanPillar
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 143
    Font name Tekton Times New Roman Times New Roman Bold Times New Roman Bold Italic Times New Roman Italic Times-Bold Times-BoldItalic TimesCE-Bold TimesCE-BoldItalic TimesCE-Italic TimesCE-Roman Times-Italic TimesNewRoman TimesNewRoman-Bold TimesNewRoman-BoldItalic TimesNewRoman-BoldItalicTT
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 144
    Font name Univers (WE) Univers (WE) Bold Univers (WE) Bold Italic Univers (WE) Medium Italic Univers (WG) Univers (WG) Bold Univers (WG) Bold Italic Univers (WG) Medium Italic Univers (WL) Univers (WL) Bold Univers (WL) Bold Italic Univers (WL) Medium Italic Univers (WR) Univers (WR) Bold Univers (
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 145
    Font name UniversCE-Condensed UniversCE-CondensedBold UniversCE-CondensedBoldOblique UniversCE-CondensedOblique UniversCE-Extended UniversCE-ExtendedObl UniversCE-Light UniversCE-LightOblique UniversCE-Medium UniversCE-Oblique Univers-Condensed Univers-CondensedBold Univers-Condensed-Bold Univers-
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 146
    Double-Byte Forms Card Fonts One DBCS Language is supported: Simplified Chinese. The column on the left indicates common font names. The column on the right indicates the actual font file resident on the Forms
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 147
    memory to printer. Missing or corrupt file download formsets again. Missing or corrupt file download formsets again. Add memory to printer. Add memory to printer. Add memory to printer. Add memory to printer. Download formset again. Add memory to printer. User or internal error Forms Print Errors
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 148
    to printer. Add memory to printer. Contact Lexmark Service. Add memory to printer. Add memory to printer. Add memory to printer. Add memory to printer. Add memory to printer. Add memory to printer. Add memory to printer. Add memory to printer. Add memory to printer. User or internal error Download
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 149
    Unable to open LFF file %s Error Type Solution Insufficient memory Add memory to printer. Insufficient memory Add memory to printer. Internal Error Contact Lexmark Service. Internal Error Contact Lexmark Service. PJC File Missing or corrupt file download formsets again. PJC File Missing
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 150
    : %s XML file missing required element: %s Error Type LFM File Insufficient memory XML Error XML Error Solution Missing or corrupt file download formsets again. Add memory to printer. Possible corrupt file download formsets again. Possible corrupt file download formsets again. Forms Print
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 151
    format: !Err: nn Printed Error Example: !ERR: 12 Invalid Character PostScript error messages To assist with troubleshooting, the Forms and Bar Code Card generates error messages when an invalid bar code condition occurs. PostScript error reporting must be enabled on the printer for these messages to
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 152
    Structure out of range Parameter buffer NULL Parameter buffer too small Parameters not saved Unknown bar code Type Unknown bar code ID Unknown bar code Type or ID Fonts not loaded Not enough memory String errors String errors result from bad input data and represent the most commonly encountered
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 153
    MicroPDF417 X MSI Plessey X X X OMR X X PDF-417 X PLANET X X QR Code X X X RSS14 X X X Singapore Post X X Swiss Postal X X UCC-128 X X British Royal Mail X X X UPC-A/E X X X USPS ZIP X X USPS FIM X X USPS Sack X X Note: Bar Code errors shown in red are
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 154
    Errors specific to symbologies Error Code Symbology Error Description 20 UPCE String not decompressed 21 HIBC Invalid Date/Time 48 HIBC Invalid Format 49 HIBC Product/Catalog number too long Note: Bar Code errors shown in red are only thrown by the Forms Card, and not by
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 155
    Code Symbology Error Description 50 HIBC Unit measure digit only 51 HIBC Invalid lot number 52 HIBC Special link char missing 53 HIBC Invalid 2-digit quantity 54 HIBC Invalid 2-digit quantity 56 MaxiCode Invalid encoding string 57 MaxiCode Encoding string
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 156
    Pro version 3.3A1 (referred to as "HP BDP"), or the Lexmark Bar Code Card version 2.5. (referred to as "LXK BCC"). Note support lowercase "a-z" character input, and does not translate to uppercase, and is operating per the specs at the URLs noted above. Therefore, the Forms and Bar Code Card firmware
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 157
    exact same way as the HP BDP. The BCE does not support lowercase "a-z" start and stop character input, does not translate to uppercase, and will throw a "Error 12 - Invalid Character" error. The BCE is operating per the specs noted above, and does not translate lowercase to uppercase. Therefore, the
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 158
    not does matter practically. Because there is no specification that calls out the absolute limit for any of encoded data should be reduced, or the user should change to a more capable bar code number of bars and spaces are the same, the proper ascenders and descenders are used, and the bar code scans
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 159
    space. MaxiCode Capacity Please refer to the AIM MaxiCode specification, which can be found at: • http://lemming.sa.ap.lexmark.com/~tbarnett/files/AIM_Maxicode_05081997.pdf On page 13, section 4.8 "Modes" defines the maximum number of characters (codewords) that can be encoded. • Section 4.8.4 says
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 160
    lexmark.com/~tbarnett/files/AIM_PDF417_spec.pdf In section 1 on pg. 1, the Introduction defines the Maximum Data Characters per symbol (at ECC0) for PDF417: • 1850 text characters • 2710 digits • 1108 bytes Section 2.1 on pg. 2 states: • "The total number BCE from throwing errors on pages with
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 161
    specified within the input data, after the typeface command 24800T. If the 2 extra bytes (Mode number 2 or 3, plus a separator) are included in the input data, the BCE will throw an error. Users should add additional parsing that examines input data: • Byte 5 for either a "2" or a "3" • Byte 6 for
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 162
    hex 2C, decimal 44 Any other separator characters should produce an error on the page. 3 MaxiCode Separator Change (add a second start with a label-number field and number-of-labels field. Both fields were one digit in length, and not produce a valid scan. If an old-style 3-byte Structured Append is specified
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 163
    , if users attempt to encode a Codabar bar code with non-numeric characters, then the !Err: 12 Invalid Character error message is String too Short error message is generated. Postcript barcodepath Operator The Postscript operator barcodepath does not work as on previous Lexmark Bar Code options
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 164
    OFIS tags to Forms Manager will result in one of two scenarios: • If the printer's Print PS Error setting is turned on, then an error page will print and the job will be flushed. The printer will then return to Ready state. • If the printer's Print PS Error setting is turned off, then the job will
  • Lexmark X651DE | Forms and Bar Code Technical Reference - Page 165
    www.lexmark.com
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165

www.lexmark.com
March 2009
Forms and Bar Code Card
Technical Reference Manual