LiftMaster CSW200UL CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual
LiftMaster CSW200UL Manual
View all LiftMaster CSW200UL manuals
Add to My Manuals
Save this manual to your list of manuals |
LiftMaster CSW200UL manual content summary:
- LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 1
OWNER'S MANUAL CSW200UL™ VEHICULAR SWING GATE OPERATOR THE CSW200UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES. INTENDED FOR PROFESSIONAL INSTALLATION ONLY. UL325 UL991 compliant compliant - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 2
- LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 3
NOTE • BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate operator unless you are an Authorized Service Technician. wiring Earth Ground Rod Installation - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 4
V I E W Single Motor and Stainless Models DC2000™ Back-Up Heater All operators come with 2 warning placards and a warranty card. Single Motor Cover Stainless Steel Cover CSW200UL™ (Single Motor) 1/2 HP Motor, 120Vac, 4 Amp. Maximum Gate Length - 20 ft. Maximum Gate Weight - 600 lbs. Maximum Pull - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 5
, garage, retail store or other building servicing the general public. Class III - Industrial/Limited access vehicular gate operator A vehicular gate operator (or protect against entrapments in both the open and close directions of gate travel. For Example: For a gate system that is installed on a - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 6
• Vertical Posts • Photoelectric Sensors • Instructional and Precautionary Signage 4. Install the gate operator only when: a. T he operator is appropriate for the construction and the usage class of the gate. b. A ll openings of a horizontal swing gate are guarded or screened from the - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 7
in the horizontal plane parallel to the roadway, between a fixed stationary object nearest the roadway, (such as a gate support post) and the gate frame when the gate is in either the fully open position or the fully closed position, shall not exceed 2-1/4 inches (57 mm), refer to ASTM F2200 for - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 8
Sensors) Install photoelectric sensors to protect against any entrapment or safety conditions encountered in your gate application. Safety loops allows the gate to stay open when vehicles are obstructing the gate path. Suggested for vehicles 14 feet or longer. If a vehicle is shorter, a center loop - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 9
Locate entrapment protection devices to protect in BOTH the open and close gate cycles. • Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls. • A swinging gate shall NOT open into public access ways. Contact Sensors (Edge Sensors) Install - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 10
SAFETY PRECAUTIONS THE CSW200UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES. Property owners MUST never mount any gate operating device near the gate's path! To prevent SERIOUS INJURY or DEATH from a moving gate: • Entrapment protection devices - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 11
(1000 lbs. 1HP) Warning Placard on both sides of gate. Low Voltage UL approved conduit High Voltage UL approved conduit Concrete Pad Earth Ground Rod is highly recommended. Master/Second Operators Maximum gate length 20 ft. (22 ft. for 1HP) Maximum gate weight is 600 lbs. (800 lbs. for DM) (1000 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 12
D A N D A R M A T T A CH M E N T Concrete Anchors 1/2" x 3-1/2" To AVOID damaging operator, DO NOT weld ANY supports to chassis. Chassis MUST be allowed to flex during operation. Electronic Box Above Ground 6" Below the Frost Line Check all Local Codes 28" Top View of Chassis 19" 5-1/4" 14 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 13
Hinge Mount bracket at least a quarter of the gate length from the gate hinge. Note: Longer gates or retro-fits may require both arms to be lengthened by equal parts. Drawing not to scale Gate Open 90° Helpful Layout Note: A) Long arm's final placement is on TOP of bracket. B) Tack weld bracket - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 14
entrapment that could occur with this type of installation. (See entrapment protection devices.) Outside Property Inside Property Gate Open 26.5" 20" Minimum Width Outside Property Inside Property Gate Closed 33" Hinge Center 2" 9" 23" 25.5" 20" to 32" Cut Long Arm Cut 10" 22" 4" 36 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 15
u p h i l l d rive w ay in s ta l l ation ( optiona l ) Not Possible Gate hits driveway. Swivel Arm Possible Special swivel arm and hinges are required. po s t mo u ntin g p l ate in s ta l l ation ( optiona l ) 3" heavy steel posts can be U- - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 16
I N S T A LL A T I O N Incorrect Installation! Gate Open Correct Installation Once the gate arm measurements are calculated: Arm is on TOP of bracket. Gate Closed Weld the bracket on the gate. Weld the longer arm.......... Completely weld around the rectangular tubes and bracket! ........then - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 17
installed CSW200UL1HP™ Models. J3 Motor, Limit Switch, Maglock/Solenoid Connection DC2000™ Back-Up Power or Reset Switch Connection Circuit Board Power LED - Operator power OK when ON. Overload LED - Operator power has overloaded when ON. On-Board 3 Button Station - Close, Stop, Open commands - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 18
Exit" Loop Detector To ENSURE proper operation of external devices: • ENSURE NOT let wire insulation interfere with connection. Remote NOT Included 315 MHz Factory Installed Radio terminals that will Open and Close with a single push of a button. All other terminals will ONLY Open with a single - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 19
the unit may be returned to service. • Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected proper grounding can protect the gate operator in most cases. The earth ground rod must be located within 3 feet from the gate operator. Use the proper type - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 20
and Dual Motor 1 HP 16 Gauge up to 150 FT up to 75 FT Black 110Vac White Neutral Use a 20 amp dedicated circuit for each operator. Input power 120Vac, 60 Hz. Earth Ground Rod Highly Recommended! See previous page. 14 Gauge 250 FT 125 FT 12 Gauge 400 FT 200 FT - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 21
using a master/second setup. Partial Master/Individual Control In order for the following operation to occur, follow the instructions. Example: There is a double gate, the entry gate is to be opened with a remote control and the exit gate with a free exit loop. Only one safety loop system is to - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 22
S O L E N O I D / M A GL O CK re l ay C O N N E C T I O N Connection of a solenoid or magnetic lock can be made using the J7 board connector and "Optional" Relay Adapter Module. Relay Contact Rating 2 Amp - 125 AC/DC 2 Amp switching load capability 20 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 23
" setting. See Adjusting Reverse Sensor(s). Socket Reset button and interlock wires, Do Not Remove. Manual Mode Auto Mode 110Vac Power Failure Push and Hold to operate gate. Gate automatically opens. 110Vac Power On, OmniControl™ Board Malfunction Turn the 110Vac power off then push and Hold - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 24
again and HOLD to Close. Key Switch Manual Three-Button N.O. Com N.O. Com N.O. Com Turn and HOLD key to Open. Turn key again and HOLD to Close. Push and HOLD a button to operate. DC 2 0 0 0 ™ E gate when there is a AC power failure and the DC2000™ is used. (See Accessories for part number - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 25
. Series Connected Outside Safety Loop To AVOID damaging control board, disconnect all power to operator before installing plug-in loop detectors. Use a different frequency for every loop detector installed. Center Loop Inside Safety Loop Plug-In "Center" Loop Detector: Allows gate to stay open - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 26
: • They should be series connected to the detector. • Have the same dimensions. • Have the same number of wire turns. (See table below.) Safety Loop NOTE: Use separate 110Vac power for each loop detector. 110Vac "Exit" Loop Detector: Allows gate to automatically open for exiting vehicles. Exit - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 27
touched, these electrically activated edge sensors immediately signal the gate operator to stop and reverse. Property owners are obligated to test edges monthly. UL Listed 3 sided Edge Sensor (See Accessories for part number.) Open and Close Contact Sensors Connect both edge sensors parallel to - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 28
If the photoelectric sensor gets blocked while the gate is closing, it will stop and reopen. The gate will remain open until the obstruction is cleared. Safety Non-Contact then the photoelectric sensors will stop ALL gate operation. Contact your local dealer for more information about photoelectric sensors. - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 29
Adjustments To reduce the risk of SERIOUS INJURY or DEATH: Disconnect power BEFORE performing ANY adjustments. SET GATE OPENING DIRECTION Open to the LEFT Open to the RIGHT 27 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 30
Screw Loosen screws to turn limit cams. Precise adjustment. c l u t c h a d j u s tment The adjustment is for a gate that is over 300 pounds and 12 feet long or longer. While the gate is closing, instantly an "open" command is given as shown below; the clutch may slip a bit, max. of 1/4 to 3/4 of - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 31
changing jumpers. To reduce the risk of SERIOUS INJURY or DEATH from a moving gate: • ALWAYS keep remote controls out of reach of children. NEVER permit children to operate, or play with remote control. • Activate gate ONLY when it can be seen clearly, is properly adjusted, and there are no - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 32
ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the remote. The operator will now operate when the push button on the remote control is pressed. Repeat Steps 1 and 2 for each remote control that will be used. Erase ALL Remote - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 33
To use the push close command, the timer should be switched to the "OFF" position. Push button once to open gate, push button again to close gate. Master/Second Operators Operators need to be connected by M/S LINK. See Linking Master page 19. M/S LINK Master Board Master/Second control boards are - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 34
Sensor is not sensitive enough = If the gate hits an object and does not stop or reverse. Maximum Sensitivity Minimum Sensitivity DC 2 0 0 0 ™ R e v e r s e S e n s o r The DC2000™ has a separate reverse sensor that will need to be adjusted. The 110Vac operator power needs to be turned off and the - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 35
O M N I c ontro l ™ b oar d c onne c tion s Purchased separately from Chamberlain Elite®. NOTE: Refer to the OmniControl™ board manual for more specific information. Second Operator 3 Button Station Dry Contact Proximity Switch 12Vdc House Alarm Stop Button Dry Contact NOTE: Cut jumper W4 wire - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 36
ANY maintenance. 9. ALL maintenance MUST be performed by a Chamberlain Elite professional. 10. SAVE THESE INSTRUCTIONS. MAINTENANCE: 1. Disconnect power before servicing. 2. The gate area should be kept clean to insure proper operation. 3. Make sure the hinges are working smoothly and lubricated - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 37
If the audio alarm goes off, always check the gate area for: • Obstructions in the gate path. • Damage to the gate and/or gate operator. OFF ON Pressing the reset switch will stop a moving gate during a normal open/close cycle, like a stop button. The operator does NOT need to be reset after doing - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 38
. Unscrew star knob. Lift off cover. Loosen red handle as shown. Gate can now be manually moved. Grab the gate to move it. To reduce the risk of SERIOUS INJURY: Do not grab the operator arm to move the gate or your fingers could get pinched. Tighten the red handle, replace the cover and knob - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 39
w i r i n g d i a GR a m • C S W 2 0 0 u l ™ a n d C S W 2 0 0 ULDM ™ NOTE: See table on next page. 37 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 40
J10 1 J10 2 J10 3 J11 10 Pins J12 10 Pins J13 10 Pins Safety Loop Input Power Neutral Center Loop Input Power 120Vac Strike Open Exit Loop Radio Receiver - Radio Receiver Fire Dept Key Switch Radio Receiver + OmniControl™ Board Limit Switch Red N.O. Motor White Normally Closed (No Wire - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 41
w i r i n g d i a GR a m • C S W 2 0 0 u l 1 H P ™ NOTE: See table on next page. 39 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 42
J3 1 J3 2 J3 3 J3 4 J3 5 J3 6 wiring table • CSW200ul1HP™ Signal Type OmniControl™ Board Direction Level (+/- 10%) Input Connection Safety Loop Input 2 Motors Output Master/Second Link Input Radio Receiver, Strike Open Push Button, Fire Dept Key Switch Inputs External Loop Detector - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 43
w i r i n g d i a GR a m • d c 2 0 0 0 ™ f o r s i n g l e a n d DM NOTE: This diagram only shows the DC2000™ wiring and all other wiring not shown is the same as the diagram on page 37. The 1 HP models Can Not have the DC2000™ battery backup system. 41 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 44
7 wiring table • dc2000™ Signal Type Open N.O. Closed N.O. Stop N.O. Reset Switch Common Manual One Button (Dry) • Key Switch (Dry) • Radio Receiver • Radio Receiver 12Vdc • Photoelectric Sensor 12Vdc - - - NOTE: All devices wired to the DC2000™ MUST be dedicated to it alone. Normal operation - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 45
Troubleshooting The Gate Will Not Operate with Remote: The radio receiver LED on the control board remains "ON" when using the remote control. The Gate Will Not Operate with Remote: The radio receiver LED on the control board remains "OFF" when using the remote control. 1. Probable Cause: Stuck - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 46
and try again. 1. This is a normal response of the gate operator. It does not represent necessarily that there is a problem. 1. This is a normal response of the gate operator. It does not represent necessarily that there is a problem. Check inputs for command. 1. Any re-new command will resume - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 47
Repair Parts K45-50676 Q268 Q062 Q061 Q059 Q269 Q084 Q118 Q244 Q057 Q216 Q247 Q018 Q044 Q210 312HM Q523 Q025 Q175 Q029* Q166 Q520 Q521 Q407 Q220 Q400E-1 Q408 Q402 Q006 Q401 K23-51142 Q404 Q410 Q409 NOTE: * Sold individually, 2 shown. For part list, refer to next page. 45 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 48
AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE. SIMPLY DIAL OUR TOLL FREE NUMBER: 1-800-528-2806 www.chamberlain.com WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART NAME • MODEL NUMBER Address orders to: THE CHAMBERLAIN GROUP, INC. Technical Support - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 49
# Q104 Swivel Arm Part # Q103 Accessories Remote Controls Omni Relay Adapter Part # Q400MAU Heater Kit Part # G6518CSW OmniControl™ Board Part # OOMNIEXB For more information about accessories: www.chamberlain.com Magnetic Lock (Outdoor) Part # MG1300 Stop Button Part # AEXITP Power Hinges - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 50
System Diagram 48 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 51
System Diagram 49 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 52
System Diagram 50 - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 53
and Property Owner knows how to shut off power to operator. 9. Verify that the gate opens and closes as needed. 10. When gate hits object during operation, it must stop or reverse direction. 11. Know how to operate the emergency manual release. 12. Make sure that any pinch point or potential - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 54
WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF - LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 55
- LiftMaster CSW200UL | CSW200UL W/ SURGE SUPPRESSION & RADIO RECEIVER Manual - Page 56
CSW200UL™ 01-50396F UL325 UL991 compliant compliant 845 Larch Avenue Elmhurst, Illinois 60126-1196 © 2009, The Chamberlain Group, Inc. - All Rights Reserved
O W N E R ’ S
M A N U A L
CSW200UL™
VEHICULAR SWING GATE OPERATOR
THE CSW200UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY
AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
INTENDED FOR PROFESSIONAL INSTALLATION ONLY.
UL325
compliant
UL991
compliant