Wiring a Radio Frequency Module, Wiegand Card Reader/Keypad - parts

Page 20 highlights

Wiring a RF Module / Card Reader / Keypad Wiring a Radio Frequency Module An optional radio frequency module and a remote antenna can be installed if the residents will access a controlled area with a transmitter. Refer to instructions supplied with the optional RF Module for more information. NOTE: The remote can control 1-4 doors. RG-6 Coaxial Connector Avoid any metallic surface around the antenna. 1 RF Module Kit Part # RFMODKT (390 MHz) or Part # RFMODKT3 (315 MHz) Remote Antenna RF Module(s) will fit in positions J400 (Device 1) and/or J407 (Device 3) (4 Mounting Screws per Board are Required) RG-6 Coaxial Cable 100 Feet Maximum Wiegand Card Reader/Keypad Wiegand card readers and keypads can be connected to either of 2 optional Wiegand modules that can be placed in the unit. Each Wiegand module supports two card readers/keypads. Some Wiegand card reader/keypads have a sixth blue wire. DO NOT connect this blue wire to the unit. Insulate this wire from the unit to prevent a short (Refer to instructions supplied with your Wiegand device for more information). J407 Position J400 Position Device 4 Device 3 Device 2 Device 1 P12V COM P5V LED DATA 0 DATA 1 DATA 1 DATA 0 LED P5V COM P12V J2 J1 P12V COM P5V LED DATA 0 DATA 1 DATA 1 DATA 0 LED P5V COM P12V J2 J1 Black Brown White Green Red Power Use 18-24 AWG Card Reader is Wired to Device 1 Blue (Insulate this wire) Shield (Attach to the unit ground only) 1 Wiegand Module Kit Part # WOMODKT Wiegand Modules will fit in J400 as Device 1 (J1) and 2 (J2) and/or J407 as Device 3 (J1) and 4 (J2) (4 Mounting Screws per Board are Required) Page 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Page 18
Wiring a RF Module / Card Reader / Keypad
Wiring a Radio Frequency Module
An optional
radio frequency module
and a remote antenna can be installed if
the residents will access a
controlled area with a transmitter.
Refer to instructions supplied with the optional
RF Module
for more
information.
Wiegand Card Reader/Keypad
Wiegand card readers and keypads can be connected to either of
2 optional Wiegand modules
that can be placed
in the unit.
Each Wiegand module supports two card readers/keypads.
Some Wiegand card reader/keypads have
a sixth blue wire. DO NOT connect this blue wire to the unit. Insulate this wire from the unit to prevent a short
(Refer to instructions supplied with your Wiegand device for more information).
RG-6
Coaxial
Connector
RG-6 Coaxial Cable
100 Feet Maximum
Remote Antenna
Avoid any metallic
surface around the
antenna.
RF Module(s) will fit in positions
J400
(
Device 1)
and/or
J407
(
Device 3)
(4 Mounting Screws per Board are Required)
1 RF Module Kit
Part # RFMODKT
(390 MHz)
or
Part # RFMODKT3
(315 MHz)
J407 Position
J400 Position
Card Reader is Wired to
Device 1
P12V
P5V
DATA 0
DATA 1
LED
COM
P12V
P5V
DATA 0
DATA 1
LED
COM
J1
J2
J1
J2
Device 1
Device 3
Device 2
Device 4
Red Power
Green
White
Brown
Black
Shield
(Attach to the
unit ground only)
Blue
(Insulate this wire)
Use 18-24
AWG
1 Wiegand Module Kit
Part # WOMODKT
P12V
P5V
DATA 0
DATA 1
LED
COM
P12V
P5V
DATA 0
DATA 1
LED
COM
Wiegand Modules will fit in
J400
as
Device 1
(J1) and
2
(J2)
and/or
J407
as
Device 3
(J1) and
4
(J2)
(4 Mounting Screws per Board are Required)
NOTE:
The remote can control 1-4 doors.