LiftMaster J J LOGIC VERSION 2-575V Manual

LiftMaster J Manual

LiftMaster J manual content summary:

  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 1
    Maintenance Cycle Counter. An LED on the 3-button station will signal when the set number of cycles is reached or when the opener requires immediate service. 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 LISTED DOOR OPERATOR
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 2
    Instructions 9 Optional Control Mounting 9 Optional Control Wiring 32 BRAKE ADJUSTMENT Brake Parts 10 CLUTCH ADJUSTMENT Clutch Parts 10 Clutch Adjustment 10 WIRING DIAGRAMS 1 PH Control Connections 13 3 PH Control Connections 14 1 PH Wiring 11 3 PH Wiring 12 STANDARD PROGRAMMING Wiring
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 3
    sensing device attached to the bottom edge of door. A REVERSING DEVICE IS STRONGLY RECOMMENDED FOR ALL COMMERCIAL OPERATOR INSTALLATIONS. REQUIRED WHEN THE 3 BUTTON CONTROL STATION IS OUT OF SIGHT OF DOOR OR ANY OTHER CONTROL (AUTOMATIC OR MANUAL) IS USED. WEIGHTS AND DIMENSIONS HANGING WEIGHT
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 4
    manual hoist hand chain systems, the handing of the operator must be determined at the time of order. The handing is indicated by last letter of the model name (R or L). The hand chain wheel can not be switched on site. If your installation causes the hand chain to hang in the door opening, hook
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 5
    on page 3. Refer to the illustration and instructions below that suits your application. 1a. Wall Mounting The operator should generally be installed below the door shaft, and as close to the door as possible. The optimum distance between the door shaft and operator drive shaft is between 12" - 15
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 6
    chain to disconnect the door from the door operator and and a disconnect chain with manual hoist to electrically disable the operator controls. 1. Refer to Model H instructions for hoist operation. 2. Refer to Model J instructions for manual operation. 6 Manual Disconnect for Models J and HJ
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 7
    IN CONJUNCTION WITH THE OPERATOR. WIRING: For wiring of your sensing device to the operator, refer to the wiring diagrams supplied on pages 13 and 14. See field connection terminals identified as Reversing Edge. TAKE-UP REEL: Take-up reel should be installed 12" above the top of the door. COIL CORD
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 8
    box is only to be accessed by trained "LIFTMASTER" technicians. If service is required contact your local LIFTMASTER dealer. Do not install any wiring or attempt to run the operator without consulting the wiring diagram. Install the optional Reversing Edge before proceeding with the Control
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 9
    SERVICE. RADIO CONTROLS On all models with B2 control wiring, a terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. Any commercial type LiftMaster brand receiver may be mounted to this bracket. The operator will then open a fully closed door, close a fully open
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 10
    System will return the door to the full open position. The Auxiliary Reversal System is designed to protect the door and motorized operator. It is not intended as a replacement for a safety sensing device, nor will it work for sectional doors when a jackshaft operator is used. WARNING CAUTION
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 11
    LOGIC CONTROL (VER. 2.0) 1 PHASE WIRING DIAGRAM 1837-1 230 VOLT MOTOR CONNECTION NOTE: CONTACTOR 1PH / 3PH SHOULD BE IN 1 PH POSITION. 115 VOLT MOTOR CONNECTION Note: 1) See Owner's Manual for Dip Switch Functions and Programming Procedures 2) TO REVERSE MOTOR DIRECTION 115 VOLTS: ALWAYS EXCHANGE
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 12
    WIRING DIAGRAM 1837-3 380/460 VOLT MOTOR CONNECTION NOTE: CONTACTOR 1PH / 3PH SHOULD BE IN 3 PH POSITION. 230 VOLT MOTOR CONNECTION Notes: 1) See Owner's Manual for Dip Switch Functions and Programming Procedures 2) TO REVERSE MOTOR DIRECTION: INTERCHANGE ANY 2 OF THE 3 POWER WIRES AT L1, L2 & L3
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 13
    STANDARD POWER & CONTROL CONNECTION DIAGRAM Logic Control Board (VER. 2.0) - 115V, 208, 230V, 1Ph 13
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 14
    STANDARD POWER & CONTROL CONNECTION DIAGRAM Logic Control Board (VER. 2.0) - 208, 230V, 380V, 460V, 3Ph 14
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 15
    switch adjustment instructions. Logic Control Pushbuttons Open, Close, Stop Open, Close and Stop buttons are mounted directly on the Logic Control board. This will provide easy programming ability and door control at the electrical box. Either the stop control or a jumper must be wired between
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 16
    safety device must be installed to operate SAFE door. See Self Monitoring Safety Device Options below. 1 2 3 4 OFF SELF MONITORING SAFETY DEVICE OPTIONS To use the operator in any of the Failsafe wiring modes, or Timer To Close wiring modes (TS, T, FSTS), a LiftMaster self monitoring safety
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 17
    cause of motor failure is eliminated. The auxiliary reversing benefits of the RPM sensor are designed to prevent excessive door and operator damage upon hitting a solid obstruction. LiftMaster recommends the use of safety devices for primary safety protection. To Program: 1. The open and close
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 18
    to an installer set height that is less than fully open. ON SET Benefit: The door will not open fully which will reduce unwanted airflow MIDSTOP through the doorway. The door will not cycle fully providing longer door and operator life. 1 2 3 4 OFF To Program: 1. Close the door. 2. Set dip
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 19
    Press This To Get This To Program: 1. Close the door. 2. Set dip switches to "Set Timer To Close" 3. Press "close" to zero out the timer. 4. Press "open" for every 5 seconds seconds the operator should wait before attempting to close the door. Example: The door is supposed to close 30 seconds
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 20
    LOGIC 2.0 PCB BOARD ILLUSTRATION RPM LEARN BUTTON (SEE PAGE 17) POWER WIRING TERMINAL BLOCK (SEE PAGES 8-9) DIP SWITCH (SEE PAGES 8-9) CONTROL WIRING TERMINAL BLOCK (SEE PAGES 8-9) OPEN, CLOSE, STOP BUTTONS 20
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 21
    a) Operator control station is wired wrong b) Motor is malfunctioning RESOLUTION Reset the RPM sensor. Also verify that the software is version 260 or better. Order replacement chips from Parts and Service. Reset the Maximum Run Timer Reset the mid-stop by programming it to be at the open limit
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 22
    dip switches to the desired wiring type. STEP 3: Relearn RPM. Because factory default is set without a door attached to the operator, factory default setting is not a preferred status. 1. Start with the door closed and set all Dip switches to the off position. 2. Press open then press and hold the
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 23
    whenever a malfunction is observed or suspected. n CAUTION: BEFORE SERVICING, ALWAYS DISCONNECT OPERATOR FROM POWER SUPPLY. HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION ARE AVAILABLE 6 DAYS A WEEK CALL OUR TOLL FREE NUMBER - 1-800
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 24
    ILLUSTRATED PARTS - ELECTRICAL BOX S2 S1 S6 S5 S3 S7 S8 S4 S9 11 L3 6 7 8 L5 2 L8 L6 5 L2 1 3 L1 L7 L3 L8 L9 4 5 L2 L6 L4 9 10 24
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 25
    box, motor or brake components be sure to match model number of your unit to kit number below to ensure proper voltage requirements. Optional modifications and/or accessories included with your operator may add or remove certain components from these lists. Please consult a parts and service
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 26
    ILLUSTRATED PARTS - Model J 5 6 7 1 8 9 C8 C20 C10 C9 D1 D7 D4 D8 D11 D3 D10 D9 D2 D5 D6 C4 C21 C6 C16 C24 C7 C17 C14 C18 C3
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 27
    available. Please consult a parts and service representative regarding availability of individual components. Refer to page 19 for all repair part ordering information. INDIVIDUAL PARTS ITEM PART # DESCRIPTION QTY 1 10-15569 Motor Plate 1 2 75-15012 Side Plate LH 1 3 75-15013 Side Plate
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 28
    ILLUSTRATED PARTS - Model H 5 6 D1 D7 D4 D8 D11 D3 C12 1 D10 D9 D2 D5 D6 C15 C6 C2 C17 C5 C7 C19 C16 C18 C4 C25 C18 C19
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

OWNER'S MANUAL
MODELS:
J
H HJ
LOGIC CONTROL (VER. 2.0)
INDUSTRIAL DUTY DOOR OPERATOR
Serial #
(located on electrical box cover)
Installation Date
Wiring Type
2 YEAR WARRANTY
LOGIC CONTROL
L
C2 Wiring
FACTORY SET
See pages 15 and 16
for other wiring
configurations
The Maintenance Alert System
allows the installer to set an internal
Maintenance Cycle Counter. An LED
on the 3-button station will signal when
the set number of cycles is reached or
when the opener requires immediate
service.
TM
PATENT PENDING
NOT FOR RESIDENTIAL USE
LISTED
DOOR
OPERATOR
41B6