    OWNER'S MANUAL MODELS: J H HJ LOGIC CONTROL (VER. 2.0) INDUSTRIAL DUTY DOOR OPERATOR LLOGIC CONTROL FACTORY SET C2 the opener requires immediate service. 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 LISTED DOOR OPERATOR
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 2
    Chain Attachment 4 INSTALLATION INSTRUCTIONS Mounting Header Bracket 5 Mounting Operator 5 Operator Support 6 Straight Arm Attachment 6 ENTRAPMENT PROTECTION ACCESSORIES Sensing Edges & Photo Eyes 7 LIMIT SWITCH ADJUSTMENT Limit Location 7 Adjustment 7 POWER & CONTROL WIRING Safety Warnings
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 3
    OR ANY OTHER CONTROL (AUTOMATIC OR MANUAL) IS USED. WEIGHTS AND DIMENSIONS HANGING WEIGHT: .........80-110 LBS. 14.44" 7.27" 7.17" 2.00" 17.63" 14.60" 4.63" MOUNTING DIMENSIONS A - Wall Mounting B - Bracket Mounting (rolling door) 3/8" BOLT 7.56" 4.41" 6.59" A B 5.50" B 1.50" A B 13.75
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 4
    TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. SECURE LOCK(S) IN "OPEN" POSITION. IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH. DO NOT CONNECT ELECTRIC POWER UNTIL INSTRUCTED TO DO SO. KEEP DOOR BALANCED. STICKING OR BINDING DOORS MUST BE REPAIRED. DOORS, DOOR
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 5
    Optimum Distance 12 - 15" Optimum Distance 12 - 15" Typical Right Hand Wall Mounted Operator FIGURE 3 IMPORTANT: The shelf or bracket must provide adequate support, prevent play between operator and door shaft, and permit operator to be fastened securely and with the drive shaft parallel to the
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 6
    HJ Keyhole Bracket Model HJ This operator includes both a floor level disconnect chain to disconnect the door from the door operator and and a disconnect chain with manual hoist to electrically disable the operator controls. 1. Refer to Model H instructions for hoist operation. 2. Refer to Model
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 7
    EDGES Sensing devices supplied for door industry type operators with an isolated normally open (N.O.) dry contact output are compatible with your operator. This includes through beam and retro reflective photo eyes and pneumatic and electric edges. If your door does not have bottom safety photo
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 8
    . SECURE LOCK(S) IN "OPEN" POSITION. IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH. CAUTION CAUTION WARNING WARNING DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND CONNECTED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. NOTE
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 9
    SERVICE. RADIO CONTROLS On all models with B2 control wiring, a terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. Any commercial type LiftMaster brand receiver may be mounted to this bracket. The operator will then open a fully closed door, close a fully open
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 10
    will return the door to the full open position. The Auxiliary Reversal System is designed to protect the door and motorized operator. It is not sectional doors when a jackshaft operator is used. WARNING CAUTION: The adjustable friction clutch is NOT an automatic reversing device. An electric or
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 11
    LOGIC CONTROL (VER. 2.0) 1 PHASE WIRING DIAGRAM 1837-1 230 VOLT MOTOR CONNECTION 115 VOLT MOTOR CONNECTION Note: 1) See Owner's Manual for Dip Switch Functions and Programming Procedures 2) TO REVERSE MOTOR DIRECTION 115 VOLTS: A LW AYS EXCHANGE PURPLE & GRAY ALL V O LTS & PHASES. 230 VOLTS:
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 12
    LOGIC CONTROL (VER. 2.0) 3 PHASE WIRING DIAGRAM 10047 380/460 VOLT MOTOR CONNECTION 230 VOLT MOTOR CONNECTION Notes: 1) See Owner's Manual for Dip Switch Functions and Programming Procedures 2) TO REVERSE MOTOR DIRECTION: INTERCHANGE ANY 2 OF THE 3 POWER WIRES AT L1, L2 & L3, OR EXCHANGE PURPLE &
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 13
    STANDARD POWER & CONTROL CONNECTION DIAGRAM Logic Control Board (VER. 2.0) - 115V, 208, 230V, 1Ph 13
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 14
    STANDARD POWER & CONTROL CONNECTION DIAGRAM Logic Control Board (VER. 2.0) - 208, 230V, 380V, 460V, 3Ph 14
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 15
    Programming the logic board, set the operators open and instructions. Logic Control Pushbuttons Open, Close, Stop Open, Close and Stop buttons are mounted directly on the Logic Control board. This will provide easy programming ability and door control at the electrical box. Either the stop control
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 16
    only dry contacts. Examples are: photocell, loop detector, pneu- matic or electrical treadles, radio controls, one button stations, pull cords, etc. 3. Open override means that the door may be reversed while closing by activating an opening device without the need to use the stop button first. 16
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 17
    . The auxiliary reversing benefits of the RPM sensor are designed to prevent excessive door and operator damage upon hitting a solid obstruction. LiftMaster recommends the use of safety devices for primary safety protection. To Program: 1. The open and close limits must be set before setting
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 18
    control station when the preset number of cycles is reached. Setting this feature is optional. By default, this feature will never activate. Open Benefit: The consumer will be aware of when it is time for a scheduled main- tenance on the door or operator. Close To Program: 1. Close the door
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 19
    be reactivated on the next operation command. Open Close Stop Single Button Control Adds 5 seconds to countdown timer. Resets the timer to close to Close will activate the door to close. Benefit: Advanced warning of door closure helps prevent traffic collisions with the door. To Program: 1. Set the
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 20
    LOGIC 2.0 PCB BOARD ILLUSTRATION RPM LEARN BUTTON (SEE PAGE 17) POWER WIRING TERMINAL BLOCK (SEE PAGES 8-9) DIP SWITCH (SEE PAGES 8-9) CONTROL WIRING TERMINAL BLOCK (SEE PAGES 8-9) OPEN, CLOSE, STOP BUTTONS 20
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 21
    a) Operator control station is wired wrong b) Motor is malfunctioning RESOLUTION Reset the RPM sensor. Also verify that the software is version 260 or better. Order replacement chips from Parts and Service. Reset the Maximum Run Timer Reset the mid-stop by programming it to be at the open limit
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 22
    not lit call for more assistance. 2. Check your control station: A. Place the operator into diagnostic mode (all DIP switches ON) B. Watch the LEDs as each control button is pressed. The LEDs should light with each Open, Close, and Single Button Control command. The Stop should turn off the LED
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 23
    AND SERVICE INFORMATION ARE AVAILABLE 6 DAYS A WEEK CALL OUR TOLL FREE NUMBER - 1-800-528-2806 MONDAY THROUGH FRIDAY 5 A.M. TO 6 P.M. (MST) SATURDAY 7 A.M. TO 3:30 P.M. (MST) WWW.LIFTMASTER.COM WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION: PART NUMBER DESCRIPTION MODEL NUMBER
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 24
    ILLUSTRATED PARTS - ELECTRICAL BOX S2 S1 S6 S5 S3 S7 S8 S4 S9 L3 11 6 7 8 L5 L8 2 L6 L2 5 L1 L7 L3 L8 L9 5 1 3 L2 L6 L4 9 10 24
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 25
    to the model number of your operator. For example: J5011L (Operator) = K-J5011L (Electrical box replacement kit) Complete Frame Replacement Kits K73-JFRAME Frame Model J K73-HFRAME-R Frame Model H (Right Hand) K73-HFRAME-L Frame Model H (Left Hand) K73-HJFRAME-R Frame Model H (Right Hand) K73
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 26
    ILLUSTRATED PARTS - Model J 9 10 11 2 3 C7 8 1 C13 C12 C11 C14 C10 C8 C9 C4 C6 C5 C13 C1 C3 C5 C13 C2 O4 O12 011 O8 O9 C2 C13 C5 O12 O11 O5 O8 O9 O1 O3 O6 O7 O12 O2 O10 6 7 1 26
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 27
    service representative regarding availability of individual components. Refer to page 11 for all repair part ordering information. INDIVIDUAL PARTS ITEM PART # DESCRIPTION QTY 1 10-10874 CONNECTING BRACKET ROLL PIN, 5/16" X 1.75" 1 O11 87-P-100S THIN WALLED RECEIVER 4 O12 80-206-12
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 28
    ILLUSTRATED PARTS - Model H 28 9 10 11 2 3 C8 C9 C7 C14 C6 C10 8 1 5 C13 C12 C11 C4 C5 C3 C1 C5 C11 C2 O4 011 O8 O12 O9 C2 C11 C5 O12 O11 O5 O8 O9 O2 O1 O3 O10 O6 O7 O12 6 7 1
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 29
    service representative regarding availability of individual components. Refer to page 11 for all repair part ordering information. INDIVIDUAL PARTS ITEM PART # DESCRIPTION QTY 1 10-10874 CONNECTING BRACKET ROLL PIN, 5/16" X 1.75" 1 O11 87-P-100S THIN WALLED RECEIVER 4 O12 80-206-12
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 30
    ILLUSTRATED PARTS - MODEL HJ 30 10 11 12 2 3 C9 9 C10 C8 C19 C6 C11 8 5 C5 C12 C17 C15 C2 C18 C14 1 C16 C13 C5 C4 C7 C17 C3 C1 O4 011 O8 O12 O9 C2 C17 C5 O12 O11 O5 O8 O9 O2 O1 O3 O10 O6 O7 O12 6 7 1
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 31
    be available. Please consult a parts and service representative regarding availability of individual components. Refer to page 11 for all repair part ordering information. INDIVIDUAL PARTS ITEM PART # DESCRIPTION QTY 1 10-10874 CONNECTING BRACKET 2 2 10-15569 MOTOR PLATE H,J-PAINT 1 3 16
  • LiftMaster J | J - NEW STYLE DISCONNECT Manual - Page 32
    MODE ONLY  See Note Open Open D1 & E2 MODE ONLY Close Close RADIO CONTROLS OPEN / CLOSE R1 R2 R3  See Note Any Commercial Type LiftMaster Brand Receiver SENSING DEVICE TO REVERSE OR STOP Note: 11 & 4 are both the same common Either is acceptable 11 8 EXTERNAL INTERLOCK Remove Factory
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

OWNER'S MANUAL
MODELS:
J
H
HJ
LOGIC CONTROL (VER. 2.0)
INDUSTRIAL DUTY DOOR OPERATOR
Serial #
(located on electrical box cover)
Installation Date
Wiring Type
2
YEAR
WARRANTY
LOGIC CONTROL
L
C2 Wiring
FACTORY SET
See pages 15 and 16
for other wiring
configurations
PATENT PENDING
The Maintenance Alert System
allows the installer to set an internal
Maintenance Cycle Counter.
An LED
on the 3-button station will signal when
the set number of cycles is reached or
when the opener requires immediate
service.
TM
NOT FOR RESIDENTIAL USE
LISTED
DOOR
OPERATOR
41B6